Quality Standards for Sample Processing, Transportation, and Storage in Hemostasis Testing
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Samples for hemostasis testing drawn into sodium citrate anticoagulant are vulnerable to the effects of preanalytical variables associated with sample processing, transportation, and storage. These variables include the temperature at which samples are transported and stored; the stability of the samples once processed; whether maintained at room temperature, refrigerated, or frozen; methods of centrifugation; as well as the potential impact of using an automated line. Acknowledgment of these variables, as well as understanding their potential impact on assay results, is imperative to the reporting of high quality and accurate results. This article discusses the preanalytical issues associated with sample processing, transportation, and storage and also presents the ideal conditions for sample handling.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Update of the guidelines for lupus anticoagulant detection
PENGO, V., TRIPODI, A., REBER, G., RAND, J. H., ORTEL, T. L., GALLI, M., & DE GROOT, P. G. (2009) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2009.03555.x · Cited by 1,197
Cited by
Kershaw, G., Mohammed, S., Lippi, G., & Favaloro, E. (2019) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0038-1677018 · Cited by 96
Self-citationUsing machine learning to identify clotted specimens in coagulation testing
Fang, K., Dong, Z., Chen, X., Zhu, J., Zhang, B., You, J., Xiao, Y., & Xia, W. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0081 · Cited by 29
Influence of posture on routine hemostasis testing
Lippi, G., Salvagno, G. L., Lima-Oliveira, G., Danese, E., Favaloro, E. J., & Guidi, G. C. (2015) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000000326 · Cited by 27
Self-citationPerformance and interpretation of mixing tests in coagulation
Kershaw, G. (2017) · Methods in molecular biology · doi:10.1007/978-1-4939-7196-1_6 · Cited by 16
Metadata
- Authors
- Adcock Funk, D., Lippi, G., & Favaloro, E.
- Venue
- Seminars in Thrombosis and Hemostasis
- Publisher
- Georg Thieme Verlag KG
- Published
- 2012-06-16
- Volume
- 38
- Issue
- 06
- Pages
- 576-585
- ISSN
- 0094-6176 (ISSN-L)
- 1098-9064
- OpenAlex
- W2041435714
- Cited by
- 144
- References
- 1
- FWCI
- 6.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quality Standards for Sample Processing, Transportation, and Storage in Hemostasis Testing. https://app.cochat.ai/papers/10.1055/s-0032-1319768
- The paper
- Adcock Funk, D., Lippi, G., & Favaloro, E. (2012). Quality Standards for Sample Processing, Transportation, and Storage in Hemostasis Testing. Seminars in Thrombosis and Hemostasis. https://doi.org/10.1055/s-0032-1319768
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.