Cited by 96Clinical Laboratory Practices and Quality ControlBlood Coagulation and Thrombosis MechanismsCoagulation, Bradykinin, Polyphosphates, and Angioedema

How to optimize activated partial thromboplastin time (APTT) testing: solutions to establishing and verifying normal reference intervals and assessing APTT reagents for sensitivity to heparin, lupus anticoagulant, and clotting factors

Kershaw, Geoffrey, Mohammed, Soma, Lippi, Giuseppe, Favaloro, Emmanuel·2019·Seminars in Thrombosis and Hemostasis

Abstract

The activated partial thromboplastin time (APTT) assay is a very common coagulation test, used for several reasons. The test is conventionally used for assessing the contact factor (intrinsic) pathway of blood coagulation, and thus for screening deficiencies in this pathway, most typically factors VIII, IX, and XI. The APTT is also sensitive to contact factor deficiencies, including factor XII, prekallikrein, and high-molecular-weight kininogen. The APTT may also be elevated in a variety of conditions, including liver disease, vitamin K deficiency, and disseminated intravascular coagulation. The APTT can also be used for monitoring unfractionated heparin (UFH) therapy, as well as for screening lupus anticoagulant (LA) or for assessing thrombosis risk. Which of these separate uses is important to a given laboratory or clinician depends on the laboratory and the clinical context. For example, UFH sensitivity is important in hospital-based laboratories, where UFH therapy is used, but not in hospital-based laboratories where low-molecular-weight heparin (LMWH) is largely employed or where UFH may be assessed by anti-factor Xa testing, or in private/community laboratories not associated with a hospital system. High sensitivity to (low levels of) factors VIII, IX, and XI is generally preferred, as their deficiencies are clinically significant. Also preferred, but not usually achieved, is low sensitivity to factor XII and other contact factors, as these deficiencies are usually asymptomatic. Nevertheless, a good knowledge of factor sensitivity is usually needed, if only to help explain the reasons for a prolonged APTT in a given patient, or whether factor testing or other investigation is required. A good working knowledge of reagents sensitivity to LA is also advisable, especially when the reagent is used as part of a LA test panel, or else as a "general-purpose screening reagent." The current report is aimed at providing some guidance around these questions, and is intended as a kind of "how to" guide, that will enable laboratories to assess APTT reagents in regard to their sensitivity to heparin, LA, and clotting factors. The report also provides some advice on generation of normal reference ranges, as well as solutions for troubleshooting prolonged APTTs, when performing factor testing or searching for inhibitors.

Integrity signals

Registry

Crossref · 10.1055/s-0038-1677018

Cites

38 of 38 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Kershaw, G., Mohammed, S., Lippi, G., & Favaloro, E.
Affiliations
  • Westmead Hospital (AU)
  • University of Verona (IT)
Corresponding author
Favaloro, Emmanuel
Venue
Seminars in Thrombosis and Hemostasis
Published
2019-01-10
Volume
45
Issue
01
Pages
022-035
ISSN
  • 0094-6176 (ISSN-L)
  • 1098-9064
OpenAlex
W2910835955
Cited by
96
References
38
Citations by year
2026: 7 · 2025: 4 · 2024: 15 · 2023: 16 · 2022: 20 · 2021: 15 · 2020: 14 · 2019: 5
FWCI
9.29
Type
journal article
Language
en
Open access
closed
Locations
  • Seminars in Thrombosis and Hemostasis (publishedVersion)
  • PubMed (publishedVersion)
Funders
NSW Health Pathology
Topics
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
  • Health Sciences › Medicine › Genetics › Coagulation, Bradykinin, Polyphosphates, and Angioedema
Keywords
activated partial thromboplastin time, lupus anticoagulant, heparin sensitivity, intrinsic coagulation pathway, factor XII deficiency, anticoagulants, heparin therapy monitoring, low molecular weight heparin
MeSH terms
Blood Coagulation Factors, Heparin, Humans, Partial Thromboplastin Time, Reference Values, Lupus Coagulation Inhibitor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review