CoChat

Multilaboratory Testing of Thrombophilia: Current and Past Practice in Australasia as Assessed through the Royal College of Pathologists of Australasia Quality Assurance Program for Hematology

Favaloro, Emmanuel J, Bonar, Roslyn, Sioufi, John, Wheeler, Michael, Low, Joyce, Aboud, Margaret, Duncan, Elizabeth, Smith, Julian, Exner, Tom, Lloyd, John, Marsden, Katherine · 2005 · Seminars in Thrombosis and Hemostasis
Cited by 41

The DOI matches its Crossref record.

Abstract

We have conducted a series of multilaboratory surveys during the last 6 years to evaluate testing proficiency in the detection of congenital and acquired thrombophilia. For lupus anticoagulant (LA) testing, participant laboratories used a panel of tests, including activated partial thromboplastin time (aPTT; 100% of laboratories), kaolin clotting time (26 to 70%), and Russell's viper venom time (RVVT; 75 to 100%). Coefficients of variation (CVs) for assays ranged from 5 to 40%. RVVT assays appeared to be most sensitive and specific for detection of LA (fewer false-negatives or -positives), although laboratories performed best when they used a panel of tests. For congenital thrombophilia, tests evaluated comprised protein C (PC), protein S (PS), antithrombin (AT), and activated protein C resistance (APCR). Most participant laboratories performed PC using chromogenic (approximately 75%), or clot based (approximately 15%) assays, with few (< 10%) performing antigenic assessments. PS was most often assessed (approximately 60%) by immunological or antigenic assays, usually of free PS, or by functional or clot-based assays (approximately 40%). AT is usually assessed by functional chromogenic assays (approximately 95%). APCR was assessed using aPTT (approximately 50%) or RVVT (approximately 50%) clot-based assays, with the aPTT APCR typically performed using factor V-deficient plasma predilution, but the RVVT APCR typically performed without. Laboratories using the RVVT APCR generally performed better in detection of factor V Leiden-associated APCR, with the aPTT method group yielding higher false-negative and/or false-positive findings (approximately 5% of occasions). Some clot-based PC and PS assays appeared to be influenced by APCR status, and yielded lower apparent PC and PS levels with positive APC resistance. The overall error rate for PC, PS, and AT was approximately 2 to 8% (i.e., false-normal interpretations for deficient plasma or false-abnormal interpretations for normal plasma). The CVs for these assays ranged from 5 to 40%, with highest CVs typically obtained with PS assays.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-2005-863805

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Favaloro, E. J., Bonar, R., Sioufi, J., Wheeler, M., Low, J., Aboud, M., Duncan, E., Smith, J., Exner, T., Lloyd, J., & Marsden, K.
Venue
Seminars in Thrombosis and Hemostasis
Published
2005-02
Volume
31
Issue
01
Pages
49-58
ISSN
  • 0094-6176 (ISSN-L)
  • 1098-9064
OpenAlex
W1977607913
Cited by
41
References
0
FWCI
1.96
Type
journal article
Language
de
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.