Variability of cut‐off values for the detection of lupus anticoagulants: results of an international multicenter multiplatform study

Open access
Tripodi, A., Chantarangkul, V., Cini, M., Devreese, K., Dlott, J. S, Giacomello, R., Gray, E., Legnani, C. +6 more·2017·Journal of Thrombosis and Haemostasis

Abstract

Essentials Between-lab variations of cut-off values in lupus anticoagulant detection are unknown. Cut-off values were calculated in 11 labs each testing plasma from 120 donors with 3 platforms. Major variation was observed even within the same platform. Cut-off values determined in different labs are not interchangeable.Summary Background Cut-off values for interpretation of lupus anticoagulant (LA) detection are poorly investigated. Aims (i) To assess whether results from healthy donors were normally distributed and (ii) the between-laboratories differences in cut-off values for screening, mixing and LA confirmation when calculated as 99th or 95th centiles, and (iii) to assess their impact on the detection rate for LA. Methods Each of 11 laboratories using one of the three widely used commercial platforms for LA detection was asked to collect plasmas from 120 healthy donors and to perform screening, mixing and LA confirmation with two methods (activated partial thromboplastin time [APTT] and dilute Russell viper venom [dRVV]). A common set of LA-positive or LA-negative freeze-dried plasmas was used to assess the LA detection rate. Results were centralized (Milano) for statistical analysis. Results and conclusions (i) Clotting times or ratios for healthy subjects were not normally distributed in the majority of cases. The take-home message is that cut-off values should be determined preferably by the non-parametric method based on centiles. (ii) There were relatively large inter-laboratory cut-off variations even within the same platform and the variability was marginally attenuated when results were expressed as ratios (test-to-normal pooled plasma). The take-home message is that cut-off values should be determined locally. (iii) There were differences between cut-off values calculated as 99th or 95th centiles that translate into a different LA detection rate (the lower the centile the greater the detection rate). The take-home message is that cut-off values determined as the 95th centile allow a better LA detection rate.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/jth.13678

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • A study of three commercial LA platforms following ISTH-SSC guidelines found platform-to-platform differences in clotting times and ratios, and differences among participants using the same platform, even after outlier exclusion.

    “Differences were observed between platforms for clotting times as well as results expressed as ratio, but also between participants using the same platform.These differences were observed even after detection and exclusion of outliers before cutoff calculation.74”

    From Guidance from the Scientific and Standardization Committee for lupus anticoagulant/antiphospholipid antibodies of the International Society on Thrombosis and Haemostasis (2020) · cites this paper as [73]

    The Results and Cut-off values sections describe three commercial platforms and differences in cut-off values between platforms and between laboratories using the same platform, for both clotting times and ratios. But the LA-negative plasma section explicitly says the authors analyzed all results without detecting or rejecting outliers. The claim that the differences persisted after outlier exclusion is therefore not supported by this study. (LLM, conf=0.92)

    Experimental — accuracy not yet measured
  • Clotting times or ratios in LA testing are not normally distributed, which supports determining cutoff values by a nonparametric centile method.

    “A recent study showed that clotting times or ratios in LA testing were not normally distributed, which confirms that cutoff values should be determined by a nonparametric method based on centiles.73”
  • Evidence shows that there is great inter-laboratory variability even when using the same analytic platform.

    “even if evidence shows that there is a great inter-laboratory variability even when using the same analytic platform [61,63].”

    From Lupus Anticoagulant Detection under the Magnifying Glass (2023) · cites this paper as [61]

  • Some works have shown that the values from the parametric approach do not respect the Gaussian probability model.

    “(even if some works have shown that these values do not respect the Gaussian probability model [61,62])”

    From Lupus Anticoagulant Detection under the Magnifying Glass (2023) · cites this paper as [61]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Horowitz GL, Altaie S, Boyd JC, Ceriotti F, Garg U, Horn P, Pesce A, Sine HE, Zakowski J. Defining, establishing, and verifying reference intervals in the clinical laboratory; approved guideline- third edition. CLSI Document C28-A3; Clinical and Laboratory Standards Institute, Wayne PA, Vol 28, Number 30, 2008.

Cited by

Sorted by citations

Authors
Tripodi, A., Chantarangkul, V., Cini, M., Devreese, K., Dlott, J. S., Giacomello, R., Gray, E., Legnani, C., Martinuzzo, M. E., Pradella, P., Siegemund, A., Subramanian, S., Suchon, P., & Testa, S.
Affiliations
  • University of Milan (IT)
  • IRCCS Azienda Ospedliero-Universitaria di Bologna Policlinico di Sant'Orsola (IT)
  • Ghent University Hospital (BE)
  • Quest Diagnostics (United States) (US)
  • University of Udine (IT)
  • National Institute for Biological Standards and Control (GB)
  • Hospital Italiano de Buenos Aires (AR)
  • Ospedale di Cattinara (IT)
  • St.John's Medical College Hospital (IN)
  • Inserm (FR)
  • Istituti Ospitalieri di Cremona (IT)
Corresponding author
Tripodi, A.
Venue
Journal of Thrombosis and Haemostasis
Publisher
Elsevier BV
Published
2017-06
Volume
15
Issue
6
Pages
1180-1190
ISSN
1538-7836 (ISSN-L)
OpenAlex
W2595302723
Cited by
35
References
20
Citations by year
2026: 2 · 2025: 2 · 2024: 3 · 2023: 3 · 2022: 5 · 2021: 3 · 2020: 7 · 2019: 4 · 2018: 3 · 2017: 3
FWCI
4.06
Type
journal article
Language
en
Open access
Locations
  • Journal of Thrombosis and Haemostasis (publishedVersion)
  • PubMed (publishedVersion)
  • HAL (submittedVersion, other-oa)
  • Institutional Research Information System (University of Udine) (submittedVersion)
  • Ghent University Academic Bibliography (Ghent University) (submittedVersion)
  • Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion)
Topics
  • Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
Keywords
lupus anticoagulant, cut-off values, inter-laboratory variability, healthy donors, activated partial thromboplastin time, anticoagulant screening
MeSH terms
Adolescent, Adult, Aged, Blood Coagulation Tests, Female, Humans, Male, Middle Aged, Partial Thromboplastin Time, Plasma, Prothrombin Time, Reference Values, Reproducibility of Results, Normal Distribution, Lupus Coagulation Inhibitor, Antiphospholipid Syndrome, Young Adult, Healthy Volunteers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review