Internal quality control and external quality assurance in testing for antiphospholipid antibodies: part II–lupus anticoagulant

Open access
Favaloro, Emmanuel, Bonar, Roslyn, Marsden, Katherine·2012·Seminars in Thrombosis and Hemostasis

Abstract

In addition to the presence of appropriate clinical features, the diagnosis of the antiphospholipid antibody syndrome (APS) fundamentally requires the finding of positive antiphospholipid antibody (aPL) test result(s), with these comprising clot-based assays for the identification of lupus anticoagulant (LA) and immunologic ("solid-phase") assays such as anticardiolipin antibodies (aCL) and anti-β2-glycoprotein I antibodies (aβ2GPI). This article is the second of two that review the process for, and provide recommendations to improve, internal quality control (IQC) and external quality assurance (EQA; or proficiency testing) for aPL assays. These processes are critical for ensuring the quality of laboratory test results, and thence the appropriate clinical diagnosis and management of APS. This article covers LA testing. We provide some updated findings from the Royal College of Pathologists of Australasia Haematology Quality Assurance Program, and cover testing results for the past 3 years (2009 to 2011 inclusive). In brief: (1) essentially all laboratories currently perform LA testing using activated partial thromboplastin time (APTT) and dilute Russell viper venom time (dRVVT) methods, and about one-third also employ the kaolin clotting time (KCT); (2) KCT usage has dropped slightly, from around 50% of laboratories in 2009, to around 35% in 2011, presumably reflecting take up of the latest consensus recommendations; (3) other methodologies such as silica clotting time (SCT) and the platelet neutralization procedure (PNP) are only used by <5% of laboratories; (4) interlaboratory coefficients of variation (CVs) are in general moderate, and substantially better than those reported for solid-phase assays such as aCL and aβ2GPI, with median (range) values being 11.6% (9.2 to 25.5%) for APTT ratios, 16.7% (10.1 to 19.2%) for KCT ratios, and 11.7% (5.7 to 17.4%) for dRVVT ratios; (5) CVs increase slightly with increasing LA positivity; (6) most laboratories correctly interpreted test findings for LA, reporting normal samples as normal, and LA-positive samples as positive (albeit with varying gradings of positivity); and (7) however, some laboratories found interpretation to be challenging for some samples, namely a weak LA sample (which was reported as normal by around 50% of laboratories) and a very strong LA sample (which was reported as normal by around 10% of laboratories, primarily those that did not perform mixing studies).

Integrity signals

Registry

Crossref · 10.1055/s-0032-1311993

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Favaloro, E., Bonar, R., & Marsden, K.
Affiliations
  • Westmead Hospital (AU)
  • Royal College of Pathologists of Australasia (AU)
  • Royal Hobart Hospital (AU)
Venue
Seminars in Thrombosis and Hemostasis
Published
2012-05-07
Volume
38
Issue
04
Pages
404-411
ISSN
  • 0094-6176 (ISSN-L)
  • 1098-9064
OpenAlex
W1970271209
Cited by
49
References
25
Citations by year
2026: 1 · 2025: 1 · 2024: 1 · 2023: 6 · 2022: 2 · 2021: 4 · 2020: 3 · 2019: 7 · 2018: 2 · 2017: 3 · 2016: 4 · 2015: 3 · 2014: 6 · 2013: 5 · 2012: 1
FWCI
3.68
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Seminars in Thrombosis and Hemostasis (publishedVersion)
  • PubMed (publishedVersion)
  • eCite Digital Repository (University of Tasmania) (submittedVersion)
  • Figshare (submittedVersion, cc-by)
Funders
Royal College of Pathologists of Australasia
Topics
  • Health Sciences › Medicine › Rheumatology › Systemic Lupus Erythematosus Research
  • Health Sciences › Medicine › Physiology › Clinical Laboratory Practices and Quality Control
  • Health Sciences › Medicine › Hematology › Blood Coagulation and Thrombosis Mechanisms
Keywords
lupus anticoagulant, antiphospholipid syndrome, internal quality control, external quality assurance, proficiency testing, activated partial thromboplastin time, dilute Russell viper venom time, kaolin clotting time, inter-laboratory variability, test result interpretation, anticardiolipin antibodies
MeSH terms
Female, Humans, Pregnancy, Pregnancy Complications, Quality Assurance, Health Care, Quality Control, Lupus Coagulation Inhibitor, Antibodies, Antiphospholipid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review