Measurement of Fractional Flow Reserve to Assess the Functional Severity of Coronary-Artery Stenoses
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The clinical significance of coronary-artery stenoses of moderate severity can be difficult to determine. Myocardial fractional flow reserve (FFR) is a new index of the functional severity of coronary stenoses that is calculated from pressure measurements made during coronary arteriography. We compared this index with the results of noninvasive tests commonly used to detect myocardial ischemia, to determine the usefulness of the index. METHODS: In 45 consecutive patients with moderate coronary stenosis and chest pain of uncertain origin, we performed bicycle exercise testing, thallium scintigraphy, stress echocardiography with dobutamine, and quantitative coronary arteriography and compared the results with measurements of FFR. RESULTS: In all 21 patients with an FFR of less than 0.75, reversible myocardial ischemia was demonstrated unequivocally on at least one noninvasive test. After coronary angioplasty or bypass surgery was performed, all the positive test results reverted to normal. In contrast, 21 of the 24 patients with an FFR of 0.75 or higher tested negative for reversible myocardial ischemia on all the noninvasive tests. No revascularization procedures were performed in these patients, and none were required during 14 months of follow-up. The sensitivity of FFR in the identification of reversible ischemia was 88 percent, the specificity 100 percent, the positive predictive value 100 percent, the negative predictive value 88 percent, and the accuracy 93 percent. CONCLUSIONS: In patients with coronary stenosis of moderate severity, FFR appears to be a useful index of the functional severity of the stenoses and the need for coronary revascularization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ryan, T. J., Faxon, D. P., Gunnar, R. M., Kennedy, J. W., King, S. B., Loop, F. D., Peterson, K. L., Reeves, T. J., Williams, D. O., & Winters, W. L. (1988) · Circulation · doi:10.1161/01.cir.78.2.486 · Cited by 2,123
Pijls, N. H., van Son, J. A., Kirkeeide, R. L., De Bruyne, B., & Gould, K. L. (1993) · Circulation · doi:10.1161/01.cir.87.4.1354 · Cited by 1,183
Self-citationEffects of adenosine on human coronary arterial circulation.
Wilson, R. F., Wyche, K., Christensen, B. V., Zimmer, S., & Laxson, D. D. (1990) · Circulation · doi:10.1161/01.cir.82.5.1595 · Cited by 906
Relation between Myocardial Blood Flow and the Severity of Coronary-Artery Stenosis
Uren, N. G., Melin, J. A., De Bruyne, B., Wijns, W., Baudhuin, T., & Camici, P. G. (1994) · New England Journal of Medicine · doi:10.1056/nejm199406233302503 · Cited by 881
Self-citationReiber, J. H., Serruys, P. W., Kooijman, C. J., Wijns, W., Slager, C. J., Gerbrands, J. J., Schuurbiers, J. C., den Boer, A., & Hugenholtz, P. G. (1985) · Circulation · doi:10.1161/01.cir.71.2.280 · Cited by 829
Echocardiographic detection of coronary artery disease during dobutamine infusion.
Sawada, S. G., Segar, D. S., Ryan, T., Brown, S. E., Dohan, A. M., Williams, R., Fineberg, N. S., Armstrong, W. F., & Feigenbaum, H. (1991) · Circulation · doi:10.1161/01.cir.83.5.1605 · Cited by 689
Nabel, E. G., Ganz, P., Gordon, J. B., Alexander, R. W., & Selwyn, A. P. (1988) · Circulation · doi:10.1161/01.cir.77.1.43 · Cited by 555
Coronary flow reserve as a physiologic measure of stenosis severity
Gould, K. L., Kirkeeide, R. L., & Buchi, M. (1990) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80078-6 · Cited by 548
Maximal Coronary Flow Reserve and Metabolic Coronary Vasodilation in Patients With Diabetes Mellitus
Nahser, P. J., Brown, R. E., Oskarsson, H., Winniford, M. D., & Rossen, J. D. (1995) · Circulation · doi:10.1161/01.cir.91.3.635 · Cited by 425
McNeill, A. J., Fioretti, P. M., El-Said, E.-S. M., Salustri, A., Forster, T., & Roelandt, J. R. T. C. (1992) · The American Journal of Cardiology · doi:10.1016/0002-9149(92)91387-j · Cited by 401
Cited by
Items 101–103 of 103
Li, J., Elrashidi, M. Y., Flammer, A. J., Lennon, R. J., Bell, M. R., Holmes, D. R., Bresnahan, J. F., Rihal, C. S., Lerman, L. O., & Lerman, A. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht005 · Cited by 163
“The accuracy of fractional flow reserve (FFR) for assessments of the functional significance of a coronary stenosis has been well established.(4) Improved clinical outcomes have been demonstrated in clinical trials when the decision to perform PCI was based on available FFR.”
MethodHerzog, C. A., Marwick, T. H., Pheley, A. M., White, C. W., Rao, V. K., & Dick, C. D. (1999) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(99)70145-9 · Cited by 162
Endovascular Pressure Measurements to Assess the Functional Severity of Mesenteric Arterial Stenoses
van Dijk, L. J. D., Terlouw, L. G., van Noord, D., Bijdevaate, D. C., Bruno, M. J., & Moelker, A. (2020) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2019.10.019 · Cited by 7
Metadata
- Authors
- Pijls, N. H. J., de Bruyne, B., Peels, K., van der Voort, P. H., Bonnier, H. J. R. M., Bartunek, J., & Koolen, J. J.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1996-06-27
- Volume
- 334
- Issue
- 26
- Pages
- 1703-1708
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2320707747
- Cited by
- 2,321
- References
- 26
- FWCI
- 30.84
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.