Increased Nuchal Translucency as a Marker for Fetal Chromosomal Defects
Open accessThe DOI matches its Crossref record.
Abstract
BACKGROUND: Screening for trisomy 21 (Down's syndrome) by measuring maternal serum alpha-fetoprotein, chorionic gonadotropin, and estriol concentrations and then performing chorionic-villus sampling or amniocentesis identifies approximately 60 percent of fetuses with this disorder. We used ultrasonography to detect increased nuchal translucency and cystic hygroma, which are characteristic features of fetuses with chromosomal defects. METHODS: We performed transvaginal ultrasonography in 10,010 unselected adolescents and women less than 40 years of age with live singleton fetuses at 10 to 15.9 weeks of gestation. Increased fetal nuchal translucency was defined as an area of translucency at least 3 mm in width, and cystic hygromas were defined as septated, fluid-filled sacs in the nuchal region. Subjects whose fetuses had these findings were offered fetal karyotyping. Information on pregnancies, deliveries, and neonates was subsequently obtained from hospital records and national birth and malformation registries. RESULTS: Nuchal translucency or cystic hygroma was seen in 76 fetuses (0.8 percent), of which 18 (24 percent) had an abnormal karyotype. The sensitivity for trisomies 21, 18, and 13 combined was 62 percent (13 of 21 fetuses), and the sensitivity for trisomy 21 alone was 54 percent (7 of 13 fetuses). CONCLUSIONS: The use of transvaginal ultrasonography to detect increased nuchal translucency and cystic hygroma is a sensitive test for fetal aneuploidy. It can be done earlier in pregnancy than serum screening, and it decreases the subsequent need for chorionic-villus sampling or amniocentesis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Snijders, R., Noble, P., Sebire, N., Souka, A., & Nicolaides, K. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11280-6 · Cited by 1,572
Nuchal translucency and other first-trimester sonographic markers of chromosomal abnormalities
Nicolaides, K. H. (2004) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2004.03.090 · Cited by 626
Hyett, J., Perdu, M., Sharland, G., Snijders, R., & Nicolaides, K. H. (1999) · BMJ · doi:10.1136/bmj.318.7176.81 · Cited by 611
Predicting delivery date by ultrasound and last menstrual period in early gestation
Taipale, P. (2001) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(00)01131-5 · Cited by 216
“During 1993–1998, all pregnant women residing in the catchment area of Jorvi hospital (western part of greater Helsinki) were invited to have transvaginal sonographic screening at 13–14 completed weeks of gestation.(7) The invitation was presented during the woman’s first antenatal visit.”
BackgroundSelf-citationMetzenbauer, M., Hafner, E., Schuchter, K., & Philipp, K. (2002) · Ultrasound in Obstetrics & Gynecology · doi:10.1046/j.1469-0705.2002.00655.x · Cited by 79
Metadata
- Authors
- Taipale, P., Hiilesmaa, V., Salonen, R., & Ylöstalo, P.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 1997-12-04
- Volume
- 337
- Issue
- 23
- Pages
- 1654-1658
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2056701148
- Cited by
- 199
- References
- 0
- FWCI
- 19.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Increased Nuchal Translucency as a Marker for Fetal Chromosomal Defects. https://app.cochat.ai/papers/10.1056/nejm199712043372303
- The paper
- Taipale, P., Hiilesmaa, V., Salonen, R., & Ylöstalo, P. (1997). Increased Nuchal Translucency as a Marker for Fetal Chromosomal Defects. New England Journal of Medicine. https://doi.org/10.1056/nejm199712043372303
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.