The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Effects of Physiologic Pacing versus Ventricular Pacing on the Risk of Stroke and Death Due to Cardiovascular Causes
Open accessAbstract
BACKGROUND: Evidence suggests that physiologic pacing (dual-chamber or atrial) may be superior to single-chamber (ventricular) pacing because it is associated with lower risks of atrial fibrillation, stroke, and death. These benefits have not been evaluated in a large, randomized, controlled trial. METHODS: At 32 Canadian centers, patients without chronic atrial fibrillation who were scheduled for a first implantation of a pacemaker to treat symptomatic bradycardia were eligible for enrollment. We randomly assigned patients to receive either a ventricular pacemaker or a physiologic pacemaker and followed them for an average of three years. The primary outcome was stroke or death due to cardiovascular causes. Secondary outcomes were death from any cause, atrial fibrillation, and hospitalization for heart failure. RESULTS: A total of 1474 patients were randomly assigned to receive a ventricular pacemaker and 1094 to receive a physiologic pacemaker. The annual rate of stroke or death due to cardiovascular causes was 5.5 percent with ventricular pacing, as compared with 4.9 percent with physiologic pacing (reduction in relative risk, 9.4 percent; 95 percent confidence interval, -10.5 to 25.7 percent [the negative value indicates an increase in risk]; P=0.33). The annual rate of atrial fibrillation was significantly lower among the patients in the physiologic-pacing group (5.3 percent) than among those in the ventricular-pacing group (6.6 percent), for a reduction in relative risk of 18.0 percent (95 percent confidence interval, 0.3 to 32.6 percent; P=0.05). The effect on the rate of atrial fibrillation was not apparent until two years after implantation. The observed annual rates of death from all causes and of hospitalization for heart failure were lower among the patients with a physiologic pacemaker than among those with a ventricular pacemaker, but not significantly so (annual rates of death, 6.6 percent with ventricular pacing and 6.3 percent with physiologic pacing; annual rates of hospitalization for heart failure, 3.5 percent and 3.1 percent, respectively). There were significantly more perioperative complications with physiologic pacing than with ventricular pacing (9.0 percent vs. 3.8 percent, P<0.001). CONCLUSIONS: Physiologic pacing provides little benefit over ventricular pacing for the prevention of stroke or death due to cardiovascular causes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In selected patients with sick sinus syndrome and fast ventricular response during AF paroxysms requiring rate control therapy, the addition of a pacemaker not only optimizes rate control but may also help to control rhythm.711,712”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [712]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer series in statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,239
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Regression Models and Life-Tables
Cox, D. R. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_37 · Cited by 26,297
Evaluation of survival data and two new rank order statistics arising in its consideration.
Mantel, N. (1966) · PubMed · Cited by 7,516
Proportional hazards tests and diagnostics based on weighted residuals
GRAMBSCH, P. M., & THERNEAU, T. M. (1994) · Biometrika · doi:10.1093/biomet/81.3.515 · Cited by 5,885
Andersen, H. R., Nielsen, J. C., Thomsen, P. E. B., Thuesen, L., Mortensen, P. T., Vesterlund, T., & Pedersen, A. K. (1997) · The Lancet · doi:10.1016/s0140-6736(97)03425-9 · Cited by 841
Lamas, G. A., Orav, E. J., Stambler, B. S., Ellenbogen, K. A., Sgarbossa, E. B., Huang, S. K. S., Marinchak, R. A., Estes, N. A. M., Mitchell, G. F., Lieberman, E. H., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199804163381602 · Cited by 640
Prospective randomised trial of atrial versus ventricular pacing in sick-sinus syndrome
Andersen, H. R., Thuesen, L., Bagger, J. P., Vesterlund, T., & Thomsen, P. E. B. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90347-6 · Cited by 490
Rosenqvist, M., Brandt, J., & Schüller, H. (1988) · American Heart Journal · doi:10.1016/0002-8703(88)90244-x · Cited by 447
Research works printed but not linked: 3
- 10.2307/2281868 · DOI · Paper page
- Mantel N, 1966, Cancer Chemother Rep, 50, 163
- Wharton JM, 1998, Circulation, 98, I
Cited by
Sorted by citations
Items 401–500 of 775
Future easy and physiological cardiac pacing
Occhetta, E. (2011) · World Journal of Cardiology · doi:10.4330/wjc.v3.i1.32 · Cited by 6
Prognosis of patients with implanted pacemakers in 4‑year follow-up
Krzemień-Wolska, K., Tomasik, A. R., Nowalany-Kozielska, E., & Jacheć, W. (2017) · Herz · doi:10.1007/s00059-017-4561-6 · Cited by 6
Timing Cycles of Implantable Devices
Wang, P. J., Al‐Ahmad, A., Hsia, H. H., Zei, P. C., Turakhia, M. P., & Perez, M. V. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-1616-0.00028-x · Cited by 6
Hemodynamics of His Bundle Pacing
Deshmukh, A., Lakshmanadoss, U., & Deshmukh, P. M. (2018) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2018.05.014 · Cited by 6
Roh, S., Kim, J. Y., Cha, H. K., Lim, H. Y., Park, Y., Lee, K., Shim, J., Choi, J., Kim, Y., & Son, G. H. (2020) · PubMed Central · doi:10.14348/molcells.2020.2164 · Cited by 6
An update on clinical trials in pacing: is dual chamber pacing better?
Hussein, S. J., Hennekens, C. H., & Lamas, G. A. (2003) · Current Opinion in Cardiology · doi:10.1097/00001573-200401000-00004 · Cited by 6
Device therapy for atrial fibrillation
Kok, L. C., & Ellenbogen, K. A. (2004) · Cardiology Clinics · doi:10.1016/s0733-8651(03)00113-9 · Cited by 6
Secondary collapse of a Palmaz stent implanted for native aortic coarctation
Agnoletti, G., Bonnet, D., & Sidi, D. (2005) · Heart · doi:10.1136/hrt.2004.035964 · Cited by 6
Hemodynamics of Cardiac Pacing: Optimization and Programming to Enhance Cardiac Function
Syed, F. F., Hayes, D. L., Friedman, P. A., & Asirvatham, S. J. (2012) · Wiley eBooks · doi:10.1002/9781118483923.ch2 · Cited by 5
Indications for Permanent and Temporary Cardiac Pacing
Vijayaraman, P., Peters, R. W., & Ellenbogen, K. A. (2005) · Wiley eBooks · doi:10.1002/9780470750674.ch1 · Cited by 6
Postoperative atrial fibrillation: some more answers, some new questions.
Vijayaraman, P., & Ellenbogen, K. A. (2003) · PubMed · Cited by 6
Harmfull effects of long-term right ventricular pacing
Barold, S. S., & Stroobandt, R. X. (2006) · Acta Cardiologica · doi:10.2143/ac.61.1.2005147 · Cited by 6
Andrade, J. G., Joza, J. E., Chew, D. S., Paredes, F. A., Bennett, M. T., Essebag, V., Greiss, I., Hawkins, N. M., Khoo, C., Kulyk, K., et al. (2026) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2025.08.363 · Cited by 6
Determination of myocardial energetic output for cardiac rhythm pacing
Heřman, D., Převorovská, S., & Maršík, F. (2007) · Cardiovascular Engineering An International Journal · doi:10.1007/s10558-007-9039-3 · Cited by 5
Current Concepts in Pacing 2010–2011: The Right and Wrong Way to Pace
Modi, S. S., Krahn, A. D., & Yee, R. K. (2011) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-011-0137-6 · Cited by 5
Pacemakers, recent directions and developments
Bourke, M. E., & Healey, J. S. (2002) · Current Opinion in Anaesthesiology · doi:10.1097/00001503-200212000-00013 · Cited by 5
The Role of Pacemakers in the Management of Patients with Atrial Fibrillation
Kalahasty, G., & Ellenbogen, K. A. (2007) · Medical Clinics of North America · doi:10.1016/j.mcna.2007.09.003 · Cited by 5
Grown up congenital heart (GUCH) disease: a half century of change
Freeman, L. J. (2008) · Clinical Medicine · doi:10.7861/clinmedicine.8-2-169 · Cited by 5
Procedural safety and long‐term follow‐up after pacemaker implantation in nonagenarians
Dang, D., Galand, V., Loirat, A., Auffret, V., Béhar, N., Mabo, P., Daubert, J., Leclercq, C., & Martins, R. P. (2018) · Clinical Cardiology · doi:10.1002/clc.23083 · Cited by 5
Magnano, M., Bissolino, A., Budano, C., Abdirashid, M., Devecchi, C., Oriente, D., Matta, M., Occhetta, E., Gaïta, F., & Rametta, F. (2022) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000001360 · Cited by 5
Poller, W. C., Dreger, H., Schwerg, M., & Melzer, C. (2015) · PLoS ONE · doi:10.1371/journal.pone.0116075 · Cited by 5
Device Therapy of Rhythm Disorders
Bürger, H., Ziegelhöffer, T., & Doll, K.-N. (2017) · Springer eBooks · doi:10.1007/978-3-662-52672-9_30 · Cited by 5
Suzuki, T., Fujino, T., Shinohara, M., Koike, H., Kinoshita, T., Yuzawa, H., & Ikeda, T. (2018) · International Heart Journal · doi:10.1536/ihj.17-526 · Cited by 5
Arimoto, T., Watanabe, E., Kohno, R., Shimeno, K., Kikuchi, K., Doi, A., Inoue, K., Nitta, T., Nogami, A., Abe, H., et al. (2020) · Journal of Arrhythmia · doi:10.1002/joa3.12459 · Cited by 5
Patel, S. M., Ackerman, M. J., & Asirvatham, S. J. (2013) · Indian Pacing and Electrophysiology Journal · doi:10.1016/s0972-6292(16)30647-7 · Cited by 5
Nonpharmacologic Treatment of Atrial Fibrillation in Elderly Persons
Willems, R., & Heidbüchel, H. (2005) · The American Journal of Geriatric Cardiology · doi:10.1111/j.1076-7460.2005.02280.x · Cited by 5
Temas de actualidad en estimulación cardíaca 2005
Calabozo, R. G., Ferrer, J. M., & de Carranza, M. J. S.-T. (2006) · Revista Española de Cardiología · doi:10.1157/13084450 · Cited by 5
Morais, J., Osterspey, A., Tamargo, J. L., Zamorano, L., Despres, C., Dickstein, K., Lekakis, J. P., McGregor, K., Metra, M., Budaj, A., et al. (2006) · Cited by 5
New developments in antibradycardic devices
Mortensen, K., Rudolph, V., Willems, S., & Ventura, R. (2007) · Expert Review of Medical Devices · doi:10.1586/17434440.4.3.321 · Cited by 5
Arrhythmias in the elderly: modern management.
Fragakis, N., & Katsaris, G. (2006) · PubMed · Cited by 5
Kogawa, R., Nakai, T., Ikeya, Y., Mano, H., Sonoda, K., Sasaki, N., Iso, K., Okumura, Y., Ohkubo, K., Kunimoto, S., et al. (2015) · International Heart Journal · doi:10.1536/ihj.15-126 · Cited by 5
Sweeney, M. O. (2004) · Elsevier eBooks · doi:10.1016/b0-7216-0323-8/50098-1 · Cited by 5
Impact of high‐grade atrioventricular block and cumulative frequent pacing on atrial arrhythmias
Wali, E., Deshmukh, A., Bukari, A., Broman, M., Aziz, Z. A., Beaser, A. D., Upadhyay, G. A., Nayak, H. M., Tung, R. H., & Özcan, C. (2018) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13425 · Cited by 5
Optimization of Pacing Algorithms to Prevent and Treat Supraventricular Tachyarrhythmias
Ricci, R. P., Boriani, G., Grammatico, A., & Santini, M. (2006) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2006.00484.x · Cited by 5
Hemodynamics of Cardiac Pacing
Wu, R. C. H., & REYNOLDS, D. W. (2005) · doi:10.1002/9780470750674.ch3 · Cited by 5
Limited Benefit of Septal Pre‐Excitation in Pace Prevention of Atrial Fibrillation
Duytschaever, M. F., Firsovaite, V., Colpaert, R., Allessie, M. A., & Tavernier, R. (2005) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2005.40435.x · Cited by 5
Andersen, H., & Nielsen, J. C. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.03.016 · Cited by 5
Musilli, N., & Padeletti, L. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi591 · Cited by 5
Atrioventricular Block Treatment: Pacing Site, AV Synchrony, or Both?
Biffi, M., Bagatin, A., Spadotto, A., Lazzeri, M., Carecci, A., Bartoli, L., Martignani, C., Angeletti, A., Diemberger, I., Massaro, G., et al. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14030980 · Cited by 4
Bodin, A., Texier, I., Bisson, A., Pierre, B., Herbert, J., Jacobs, M., Nasarre, M., Bernard, A. B., & Fauchier, L. (2024) · EP Europace · doi:10.1093/europace/euae238 · Cited by 4
Physiological Pacing: Historical Review With an Eye to the Future
Sutton, R., & Prakash, A. (2025) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16559 · Cited by 4
Kato, Y., Hayashi, T., Kato, R., Tanahashi, N., & Takao, M. (2017) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2017.06.020 · Cited by 4
Paradigm Shifts in Cardiac Pacing: Where Have We Been and What Lies Ahead?
Ballantyne, B. A., Chew, D. S., & Vandenberk, B. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12082938 · Cited by 4
Potential Prevention of Pacing‐Induced Heart Failure Using Simple Pacemaker Programming Algorithm
Chwyczko, T., Dąbrowski, R., Maciąg, A., Sterlinski, M. M., Bąk, E. S., Borowiec, A., Kowalik, I., Łabęcka, A., Jankowska, A., Kośmicki, M., et al. (2013) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12049 · Cited by 4
Recent Advancement in the Management of the Cardiac Arrhythmia
Cho, J.-G. (2010) · Journal of Korean Medical Association · doi:10.5124/jkma.2010.53.3.190 · Cited by 4
Managing Advisories of Cardiac Implantable Electronic Devices
Parkash, R., & Bennett, M. T. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-37804-8.00042-0 · Cited by 4
Pacing for Sinus Node Disease: Indications, Techniques, and Clinical Trials
Gillis, A. M. (2007) · Elsevier eBooks · doi:10.1016/b978-1-4160-2536-8.50018-2 · Cited by 4
Pacing mode survival in patients with single chamber atrial pacemaker for sinus node dysfunction
Velayuthan, R., Sukumaran, S. K., Bootla, D., Balaguru, S., Anantharaj, A., Satheesh, S., & Selvaraj, R. J. (2023) · Indian Heart Journal · doi:10.1016/j.ihj.2023.12.004 · Cited by 4
Lin, D., Jiang, F., Wu, C., Li, Y., Zhang, X., & Wang, Y. (2021) · Annals of Translational Medicine · doi:10.21037/atm-21-1792 · Cited by 4
Blich, M., Suleiman, M. A., Zeidan-Shwiri, T., Marai, I., Boulos, M., & AMIKAM, S. (2010) · Clinical Cardiology · doi:10.1002/clc.20695 · Cited by 4
Miki, Y., Ishikawa, T., Inoue, N., Yamakawa, Y., Kobayashi, T., Matsushita, K., Matsumoto, K., Taima, M., Kosuge, M., Sumita, S., et al. (2008) · International Heart Journal · doi:10.1536/ihj.49.273 · Cited by 4
Chiladakis, J. A., Koutsogiannis, N., Kalogeropoulos, A. P., & Alexopoulos, D. (2007) · Cardiology · doi:10.1159/000099098 · Cited by 4
Galtes, I., & Lamas, G. A. (2004) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-004-0022-7 · Cited by 4
Elder, D. H. J., Lang, C. C., Rekhraj, S., Szwejkowski, B. R., Casella, G., Pringle, S. D., Struthers, A. D., & Choy, A. M. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.11.021 · Cited by 4
Berlanga, A. C., Casado, M. S., Borrego, J. M. D., Raigal-Caño, A., & Rodríguez, P. S. (2010) · Medicina Intensiva · doi:10.1016/j.medin.2010.01.008 · Cited by 4
Prospective randomized trials on pacing mode: what have we learned?
CHARLES, R. G. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)01296-0 · Cited by 4
Comparison of the Effects of VVI Versus DDD Pacing on Cardiac Baroreflex Function
Oginosawa, Y., Abe, H., Yasumasu, T., Tsurugi, T., & Kohno, R. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00363.x · Cited by 4
Vlietstra, R. E., Jahangir, A., & Shen, W. K. (2005) · The American Journal of Geriatric Cardiology · doi:10.1111/j.1076-7460.2005.03329.x · Cited by 4
Late atrial appendage perforation from a pacemaker lead pacemaker complication
Souretis, G., Kotoulas, C., Xapladeris, P., Flessas, D., Laschos, N., & Lazarides, K. (2013) · Asian Cardiovascular and Thoracic Annals · doi:10.1177/0218492312467541 · Cited by 4
Matsuda, Y., Masuda, M., Asai, M., Iida, O., Okamoto, S., Ishihara, T., Nanto, K., Kanda, T., Tsujimura, T., Okuno, S., et al. (2020) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-020-00797-9 · Cited by 4
Novedades en estimulación cardiaca
Ferrer, J. M., Andrés, M. L. F., Pichardo, R. B., & de Carranza, M. J. S.-T. (2009) · Revista Española de Cardiología · doi:10.1016/s0300-8932(09)70046-6 · Cited by 4
Clinical Trials in Pacing for Bradyarrhythmias
Sutton, R. (2003) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1026224121547 · Cited by 4
Consenso de Fibrilación Auricular
Elizari, M. V. (2005) · Redalyc (Universidad Autónoma del Estado de México) · Cited by 4
Atrial Tachyarrhythmias Detected by Automatic Mode Switching:
Estes, N. A. M. (2004) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2004.04112.x · Cited by 4
Willems, R., & Gillis, A. M. (2003) · Current Cardiology Reports · doi:10.1007/s11886-003-0093-1 · Cited by 4
IMPLANTABLE CARDIOVERTER DEFIBRILLATORS IN HEART FAILURE
Sweeney, M. O., Ellison, K., & Stevenson, W. G. (2001) · Cardiology Clinics · doi:10.1016/s0733-8651(05)70251-4 · Cited by 4
Atrial fibrillation in the elderly
Chen, J., & Rich, M. W. (2003) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-003-0042-8 · Cited by 3
Jagosz, M., Jędrzejczyk‐Patej, E., Kowalska, W., Mazurek, M., Warwas, S., Wiktor, D., Sokal, A., Kowalski, O., Lenarczyk, R., Średniawa, B., et al. (2022) · Kardiologia Polska · doi:10.33963/kp.a2022.0110 · Cited by 3
Noda, T., Ueda, N., Tanaka, Y., Ishiguro, Y., Matsumoto, T., Uenishi, T., Yamaguchi, H., Shoji, A., Myung, J.-E., & KUSANO, K. F. (2023) · EP Europace · doi:10.1093/europace/euad003 · Cited by 4
Marshall, H. J., & GAMMAGE, M. D. (2002) · The American Journal of Geriatric Cardiology · doi:10.1111/j.1076-7460.2002.00068.x · Cited by 3
Gonuguntla, K., Ejaz, K., Rojulpote, C., Shaik, A., Bhattaru, A., Buch, T., Avula, S., Rauniyar, R., Singh, V. P., Karambelkar, P., et al. (2021) · Europe PMC (PubMed Central) · Cited by 3
Strohmer, B., Mermi, J., Castellanos, E., Mayr, H., Gill, J. S., Abadía, A. A., Kuehl, M., & Wolpert, C. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.00002.x · Cited by 3
Paced QRS morphology predicts incident left ventricular systolic dysfunction and atrial fibrillation
van Zyl, M., Witt, C. M., Bhatia, S., Khasawneh, M., Gaba, P., Lenz, C. J., Rosenbaum, A. N., Aung, H., Hodge, D. O., McLeod, C. J., et al. (2019) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2019.03.001 · Cited by 3
Cardiac Stimulation in the Third Millennium: Where Do We Head from Here?
Biffi, M., Spadotto, A., Piemontese, G. P., Toniolo, S., Bartoli, L., Sorrentino, S., Minguzzi, A., Massaro, G., Capobianco, C., & Statuto, G. (2021) · Hearts · doi:10.3390/hearts2010003 · Cited by 3
Mabo, P., Cebron, J., Solnon, A., TASSIN, A., Graindorge, L., & Gras, D. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9703-4 · Cited by 3
Current management of the tachybrady syndrome
Yadav, A. V., & Scheinman, M. M. (2002) · ACC Current Journal Review · doi:10.1016/s1062-1458(01)00530-x · Cited by 3
Lin, J.-M., Lai, L., Tsai, C., Lin, L., Tseng, C.-D., & Lin, J.-L. (2007) · Cardiology · doi:10.1159/000111926 · Cited by 3
Estimulación cardiaca en situaciones diversas
Andrés, M. L. F., Pérez, J. T., Álvarez, L. P., Nicolás, J. R., Ferrer, J. M., & Montiel, J. D. J. (2007) · Revista Española de Cardiología Suplementos · doi:10.1016/s1131-3587(07)75263-9 · Cited by 3
Ferro, A., Duilio, C., Santomauro, M., Salvatore, M., & Cuocolo, A. (2005) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-005-1790-3 · Cited by 3
Gillis, A. M. (2003) · Cardiac Electrophysiology Review · doi:10.1023/b:cepr.0000023130.12304.e4 · Cited by 3
Alternative Stimulationsorte zur Prävention von Vorhofflimmern
Israel, C. W. (2002) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s003990200005 · Cited by 3
Sashida, Y., Mori, F., Arashi, H., Hosaka, F., Itai, T., & Ohnishi, S. (2006) · Journal of Arrhythmia · doi:10.1016/s1880-4276(06)80035-9 · Cited by 3
Psychari, S. N., Apostolou, T. S., Iliodromitis, E. K., Charalampopoulos, A. F., & Kremastinos, D. T. (2009) · International Journal of Cardiology · doi:10.1016/j.ijcard.2009.03.017 · Cited by 3
Gulizia, M. M., Mangiameli, S., Chiarandà, G., Spadola, V., Giovanni, N. D., Colletti, A., Bulla, V., Circo, A., Pensabene, O., Vasquez, L., et al. (2006) · EP Europace · doi:10.1093/europace/eul003 · Cited by 3
Routine Use of Biventricular Pacing Is Not Warranted for Patients With Heart Block
Arenas, I. A., Jacobson, J. T., & Lamas, G. A. (2015) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.114.000627 · Cited by 3
Gillis, A. M. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-1616-0.00013-8 · Cited by 3
Saskena, S., DOMANSKI, M. J., Benjamin, E. J., Camm, A. J., Ezekowitz, M. D., Gersh, B. J., Jalife, J., Naccarelli, G. V., Vlietstra, R. E., & Wyse, D. G. (2001) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1011489306778 · Cited by 3
Medium-long-term mortality and change in functional status in elderly patients with pacemaker
Pérez‐Díaz, P., Jiménez‐Díaz, J., Higuera‐Sobrino, F., Piqueras‐Flores, J., Frías-García, R., Mazoteras-Muñoz, V., Maseda-Uriza, R., & Arenas-Cambronero, V. (2020) · Archivos de cardiolog�a de M�xico (English ed Internet) · doi:10.24875/acme.m19000052 · Cited by 3
Hellkamp, A. S., Lee, K. L., Sweeney, M. O., Link, M. S., & Lamas, G. A. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.01.069 · Cited by 3
Impact of Pacemakers: When and What Kind?
Toff, W. D., & Camm, A. J. (2002) · Wiley eBooks · doi:10.1002/9780470986882.ch42 · Cited by 3
Impact of Congenital Heart Disease at Adulthood
Opić, P. (2013) · RePub (Erasmus University Rotterdam) · Cited by 3
Some Recent Randomized Clinical Trials in the Management of Atrial Fibrillation
Wyse, D. G. (2003) · Journal of Interventional Cardiac Electrophysiology · doi:10.1023/a:1026292609252 · Cited by 3
Atrial fibrillation: profit from cardiac pacing?
Yang, A., L�deritz, B., & Lewalter, T. (2005) · Zeitschrift für Kardiologie · doi:10.1007/s00392-005-0196-3 · Cited by 3
Use of Physiologic Pacing After the Canadian Trial of Physiologic Pacing
Tyers, G. F. O., Gao, M., HAYDEN, R. I., Leather, R. A., ASHTON, T. G., & KIELY, M. (2005) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2005.00044.x · Cited by 3
Pacemaker selection: time for a rethinking of complex pacing systems
Silberbauer, J. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi803 · Cited by 3
Right ventricular pacing: Has DAVID slain this Goliath?
Goldberger, J. J. (2005) · Heart Rhythm · doi:10.1016/j.hrthm.2005.06.004 · Cited by 3
Electrical Therapy of Atrial Fibrillation
Petrač, D. (2001) · Journal für Kardiologie (Krause & Pachernegg GmbH) · Cited by 3
UKPACE: to die, or not to die ... Is that the question?
Lin, J. C. (2006) · EP Europace · doi:10.1093/europace/eul085 · Cited by 3
Gułaj, M., Sodolski, T., & Kutarski, A. (2007) · PubMed · Cited by 3
Upgrading from Right Ventricular Apical Pacing to Biventricular Pacing
Schoenfeld, M. H. (2004) · Springer eBooks · doi:10.1007/978-88-470-2137-2_108 · Cited by 3
Metadata
- Authors
- Connolly, S. J., Kerr, C. R., Gent, M., Roberts, R. S., Yusuf, S., Gillis, A. M., Sami, M. H., Talajic, M., Tang, A. S. L., Klein, G. J., Lau, C., & Newman, D. M.
- Affiliations
- McMaster University (CA)
- University of British Columbia (CA)
- University of Calgary (CA)
- McGill University (CA)
- Montreal Heart Institute (CA)
- University of Ottawa (CA)
- Western University (CA)
- University of Toronto (CA)
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2000-05-11
- Volume
- 342
- Issue
- 19
- Pages
- 1385-1391
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2332653577
- Cited by
- 775
- References
- 16
- Citations by year
- 2026: 8 · 2025: 9 · 2024: 8 · 2023: 16 · 2022: 14 · 2021: 14 · 2020: 21 · 2019: 19 · 2018: 23 · 2017: 15 · 2016: 26 · 2015: 25 · 2014: 23 · 2013: 28 · 2012: 35
- FWCI
- 31.24
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Keywords
- physiological pacing, ventricular pacing, dual-chamber pacemaker, atrial pacing, bradycardia, pacemaker implantation, stroke, cardiovascular mortality, atrial fibrillation, heart failure hospitalization, perioperative complications, symptomatic bradycardia
- MeSH terms
- Aged, Atrial Fibrillation, Bradycardia, Cardiac Pacing, Artificial, Cardiovascular Diseases, Female, Heart Block, Humans, Male, Pacemaker, Artificial, Risk, Stroke
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review