The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Effects of Physiologic Pacing versus Ventricular Pacing on the Risk of Stroke and Death Due to Cardiovascular Causes
Open accessAbstract
BACKGROUND: Evidence suggests that physiologic pacing (dual-chamber or atrial) may be superior to single-chamber (ventricular) pacing because it is associated with lower risks of atrial fibrillation, stroke, and death. These benefits have not been evaluated in a large, randomized, controlled trial. METHODS: At 32 Canadian centers, patients without chronic atrial fibrillation who were scheduled for a first implantation of a pacemaker to treat symptomatic bradycardia were eligible for enrollment. We randomly assigned patients to receive either a ventricular pacemaker or a physiologic pacemaker and followed them for an average of three years. The primary outcome was stroke or death due to cardiovascular causes. Secondary outcomes were death from any cause, atrial fibrillation, and hospitalization for heart failure. RESULTS: A total of 1474 patients were randomly assigned to receive a ventricular pacemaker and 1094 to receive a physiologic pacemaker. The annual rate of stroke or death due to cardiovascular causes was 5.5 percent with ventricular pacing, as compared with 4.9 percent with physiologic pacing (reduction in relative risk, 9.4 percent; 95 percent confidence interval, -10.5 to 25.7 percent [the negative value indicates an increase in risk]; P=0.33). The annual rate of atrial fibrillation was significantly lower among the patients in the physiologic-pacing group (5.3 percent) than among those in the ventricular-pacing group (6.6 percent), for a reduction in relative risk of 18.0 percent (95 percent confidence interval, 0.3 to 32.6 percent; P=0.05). The effect on the rate of atrial fibrillation was not apparent until two years after implantation. The observed annual rates of death from all causes and of hospitalization for heart failure were lower among the patients with a physiologic pacemaker than among those with a ventricular pacemaker, but not significantly so (annual rates of death, 6.6 percent with ventricular pacing and 6.3 percent with physiologic pacing; annual rates of hospitalization for heart failure, 3.5 percent and 3.1 percent, respectively). There were significantly more perioperative complications with physiologic pacing than with ventricular pacing (9.0 percent vs. 3.8 percent, P<0.001). CONCLUSIONS: Physiologic pacing provides little benefit over ventricular pacing for the prevention of stroke or death due to cardiovascular causes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In selected patients with sick sinus syndrome and fast ventricular response during AF paroxysms requiring rate control therapy, the addition of a pacemaker not only optimizes rate control but may also help to control rhythm.711,712”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [712]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer series in statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,239
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Regression Models and Life-Tables
Cox, D. R. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_37 · Cited by 26,297
Evaluation of survival data and two new rank order statistics arising in its consideration.
Mantel, N. (1966) · PubMed · Cited by 7,516
Proportional hazards tests and diagnostics based on weighted residuals
GRAMBSCH, P. M., & THERNEAU, T. M. (1994) · Biometrika · doi:10.1093/biomet/81.3.515 · Cited by 5,885
Andersen, H. R., Nielsen, J. C., Thomsen, P. E. B., Thuesen, L., Mortensen, P. T., Vesterlund, T., & Pedersen, A. K. (1997) · The Lancet · doi:10.1016/s0140-6736(97)03425-9 · Cited by 841
Lamas, G. A., Orav, E. J., Stambler, B. S., Ellenbogen, K. A., Sgarbossa, E. B., Huang, S. K. S., Marinchak, R. A., Estes, N. A. M., Mitchell, G. F., Lieberman, E. H., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199804163381602 · Cited by 640
Prospective randomised trial of atrial versus ventricular pacing in sick-sinus syndrome
Andersen, H. R., Thuesen, L., Bagger, J. P., Vesterlund, T., & Thomsen, P. E. B. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90347-6 · Cited by 490
Rosenqvist, M., Brandt, J., & Schüller, H. (1988) · American Heart Journal · doi:10.1016/0002-8703(88)90244-x · Cited by 447
Research works printed but not linked: 3
- 10.2307/2281868 · DOI · Paper page
- Mantel N, 1966, Cancer Chemother Rep, 50, 163
- Wharton JM, 1998, Circulation, 98, I
Cited by
Sorted by citations
Items 701–775 of 775
OBSOLETE: Implanted Pacemakers - Indications and Novel Programming
Willems, R. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99787-3
Selective Reporting: Silent Atrial Fibrillation and Cryptogenic Strokes
Reiffel, J. A. (2017) · The American Journal of Medicine · doi:10.1016/j.amjmed.2017.03.039
Swiontkowski, M. F. (2001) · Journal of Orthopaedic Trauma · doi:10.1097/00005131-200108000-00017
Interventions and Implantable Devices for Inherited Cardiac Conditions
Yousef, Z. R., & Drury‐Smith, M. (2018) · Springer eBooks · doi:10.1007/978-3-319-66114-8_30
Therapie von bradykarden Herzrhythmusstörungen
Schuchert, A., & Andrié, R. (2018) · Elsevier eBooks · doi:10.1016/b978-3-437-24950-1.00011-1
Cardiac Pacing and Defibrillation
Hsia, H. H. (2010) · Springer eBooks · doi:10.1007/978-0-387-77452-7_6
Yavuz, E., Akkurt, M. S., Yiğitbaş, H., Gülçiçek, O. B., Erçetin, C., Karagülle, O. O., Çelik, A., & Çelebi, F. (2018) · Bagcilar Medical Bulletin · doi:10.5350/bmb20180427024330
Clinical Trials of Pacing Modes
Healey, J. S., Morillo, C. A., & Connolly, S. J. (2007) · Elsevier eBooks · doi:10.1016/b978-1-4160-2536-8.50015-7
Freund, N. S., Brody, E. A., & Ott, P. (2008) · The American Journal of Medicine · doi:10.1016/j.amjmed.2008.01.022
Fahreignung bei implantierten kardiovaskulären elektrischen Geräten
Mijić, D., Lemke, B., & Bogossian, H. (2019) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-019-0626-y
Pérez‐Díaz, P., Jiménez‐Díaz, J., Higuera‐Sobrino, F., Piqueras‐Flores, J., Frías-García, R., Mazoteras-Muñoz, V., Maseda-Uriza, R., & Arenas-Cambronero, V. (2019) · Archivos de cardiología de México · doi:10.24875/acm.m19000053
Nonpharmacological Treatment of Atrial Fibrillation: What Is the Role of Device Therapy?
Riedlbauchová, L., Durdil, V., Honěk, J., & Veselka, J. (2020) · International Journal of Angiology · doi:10.1055/s-0040-1708529
Uso Racional dos Cabos-Eletrodos na Estimulação Cardíaca Artificial
Duarte, C. E., & Sbaraini, A. B. (2020) · Journal of Cardiac Arrhythmias · doi:10.24207/jca.v32n4.979_pt
Rational Use of Leads in Artificial Cardiac Pacing
Duarte, C. E., & Sbaraini, A. B. (2020) · Journal of Cardiac Arrhythmias · doi:10.24207/jca.v32n4.979_in
Zhao, Y., Ma, J., Zang, X., Fu, H., Song, W., Chen, K., & Wang, X. (2019) · International Journal of Heart Rhythm · doi:10.4103/ijhr.ijhr_3_20
ERKRANKUNGEN DES HERZENS UND DES KREISLAUFS
Jung, N., Mayet, W.-J., Mertens, P. R., (federführend), J. M., Müller, O.-A., Pfeifer, M., Schellinger, P. D., Weiss, N., & Wendtner, C.-M. (2020) · Elsevier eBooks · doi:10.1016/b978-3-437-06282-7.50011-5
İnce, O., Gülşen, K., Özcan, S., Okuyan, E., & Çeliker, C. (2020) · Bagcilar Medical Bulletin · doi:10.4274/bmb.galenos.2020.05.018
Inappropriate tachycardia at rest as a consequence of atrial preference pacing algorithm
Akdemir, B. (2020) · Revista Portuguesa de Cardiologia · doi:10.1016/j.repc.2020.05.014
Chronotropic Incompetence and Pacing in HPEF Heart Failure with Preserved Ejection Fraction
Lambert, C. T., & Grimm, R. A. (2020) · Elsevier eBooks · doi:10.1016/b978-0-323-64067-1.00030-9
Segal, O. R., Markides, V., Davies, D. W., & Peters, N. S. (2006) · doi:10.1002/9780470750537.ch2
The Change of Cardiac Pacing Leads Location
邹, 春. (2021) · Advances in Clinical Medicine · doi:10.12677/acm.2021.117481
Hemodynamics of Cardiac Pacing
DeSimone, C. V., Gullickson, J., Hayes, D. L., Friedman, P. A., & Asirvatham, S. J. (2021) · Wiley eBooks · doi:10.1002/9781119264002.ch2
Atrial resynchronization therapy: An emerging potential to advance physiologic pacing?
Estes, N. A. M., & Saba, S. (2021) · Heart Rhythm · doi:10.1016/j.hrthm.2021.11.029
Hayes, D. L. (2004) · Elsevier eBooks · doi:10.1016/b0-7216-0323-8/50112-3
Notfälle bei Herzschrittmacherpatienten
Trappe, H. (2008) · Steinkopff eBooks · doi:10.1007/978-3-7985-1886-5_6
Permanent Pacemaker and Implantable Cardioverter Defibrillator
Hanna, E. B. (2022) · Wiley eBooks · doi:10.1002/9781119832737.ch14
(2007) · Springer eBooks · doi:10.1007/978-3-540-34372-1_29
Dixit, S., & Marchlinski, F. E. (2007) · Springer eBooks · doi:10.1007/978-1-84628-715-2_103
Bajpai, A., & Camm, A. J. (2012) · Wiley eBooks · doi:10.1002/9781118451786.ch5
Bajpai, A., & Camm, A. J. (2012) · Wiley eBooks · doi:10.1002/9781119952930.ch36
Camm, C. F., & Camm, A. J. (2022) · Wiley eBooks · doi:10.1002/9781119484288.ch29
Permanent Pacemaker and Implantable Cardioverter Defibrillator
Hanna, E. B. (2017) · Wiley eBooks · doi:10.1002/9781119233503.ch14
Novedades en estimulación cardiaca
Ferrer, J. M., Andrés, M. L. F., Pichardo, R. B., & de Carranza, M. J. S.-T. (2009) · Revista Española de Cardiología Suplementos · doi:10.1016/s1131-3587(09)71777-7
Beck, H., & Curtis, A. B. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-817728-0.00075-9
Therapie von bradykarden Herzrhythmusstörungen
Schuchert, A., & Andrié, R. P. (2019) · Elsevier eBooks · doi:10.1016/b978-3-437-24951-8.00009-9
(2011) · Elsevier eBooks · doi:10.1016/b978-3-437-24331-8.10015-6
Schuchert, A., & Andrié, R. (2021) · Elsevier eBooks · doi:10.1016/b978-3-437-23834-5.00012-8
Inappropriate tachycardia at rest as a consequence of atrial preference pacing algorithm
Akdemir, B. (2020) · Revista Portuguesa de Cardiologia (English Edition) · doi:10.1016/j.repce.2020.05.018
(2005) · Steinkopff eBooks · doi:10.1007/3-7985-1530-1_12
Notfälle bei Herzschrittmacherpatienten
Trappe, H. (2008) · Intensivmedizin und Notfallmedizin · doi:10.1007/s00390-008-0877-z
(2008) · Springer eBooks · doi:10.1007/978-3-540-79122-5_29
Markewitz, A. (2006) · Steinkopff eBooks · doi:10.1007/3-7985-1651-0_21
Dalen, J. E., & Alpert, J. S. (2017) · The American Journal of Medicine · doi:10.1016/j.amjmed.2017.04.025
Hoppe, C. (2005) · Springer eBooks · doi:10.1007/3-540-29425-2_3
Devices for the Management of Atrial Fibrillation
Jung, W., & Saksena, S. V. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-0285-9.00092-2
Sinusknotensyndrom (Sick-Sinus-Syndrom) und Karotissinussyndrom
(2008) · Springer eBooks · doi:10.1007/978-3-540-79122-5_23
Goldschlager, N., Ho, S. Y., Lazzara, R., Naccarelli, G. V., Kusumoto, F. M., & Goldschlager, N. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-0285-9.00042-9
Lee, W.-H., Lee, C., Tsai, W., Lin, F.-H., Tsai, W.-L., Chen, Y., Chen, C.-J., Hsu, P., Chu, C., Lin, T., et al. (2020) · doi:10.21203/rs.3.rs-25775/v1
Sinusknotensyndrom (Sick-Sinus-Syndrom) und Karotissinussyndrom
(2007) · Springer eBooks · doi:10.1007/978-3-540-34372-1_23
Single-center Experience of AAIR Pacemakers for Sinus Node Dysfunction
Sharma, R. K., Dahiya, A., Thakur, M., Joshi, P., & Pratap, A. (2022) · Journal of Mahatma Gandhi University of Medical Sciences and Technology · doi:10.5005/jp-journals-10057-0192
Ashar, T., Ashar, A., & Golding, B. (2023) · HeartRhythm Case Reports · doi:10.1016/j.hrcr.2023.10.021
Schuchert, A., & Andrié, R. (2024) · Elsevier eBooks · doi:10.1016/b978-3-437-21003-7.00012-1
Ho, C. Y.-C., & Stiles, M. K. (2024) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2024.06.002
Implanted Pacemakers - Indications and Programming
Slenter, R. H. J., & Willems, R. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-15734-9.00027-3
The QRS Interval After Pacemaker Implant: An Independent Mortality Risk Factor
Vanerio, G. (2025) · Critical Pathways in Cardiology A Journal of Evidence-Based Medicine · doi:10.1097/hpc.0000000000000385
Ho, C. Y.-C., & Stiles, M. K. (2025) · Cardiology Clinics · doi:10.1016/j.ccl.2025.05.004
European Counterpoint to Chapter 23
Connelly, D. T. (2007) · Humana Press eBooks · doi:10.1007/978-1-59259-975-2_50
New Results from Trials in Atrial Fibrillation
McComb, J. M. (2001) · Cardiac Electrophysiology Review · doi:10.1023/a:1011445203259
Importance of the Right Ventricular Pacing Site in Cardiac Resynchronization
Jauvert, G., Alonso, C., Cazeau, S., Lazarus, A., & Ritter, P. (2007) · Springer eBooks · doi:10.1007/978-0-387-71167-6_3
From pacemaker to cardiac rhythm and disease management
KAPPENBERGER, L. J. (2010) · Cardiovascular Medicine · doi:10.4414/cvm.2010.01475
Cardiac Implantable Electronic Devices for Heart Failure
Glikson, M., & Bogdan, S. N. (2025) · Springer eBooks · doi:10.1007/978-3-031-96562-3_13
What Is the Best Evidence for Making Clinical Decisions?—Reply
Guyatt, G. H., Naylor, D., Richardson, W. S., Green, L., Haynes, R. B., Wilson, M. C., Cook, D. J., & Jaeschke, R. Z. (2000) · JAMA · doi:10.1001/jama.284.24.3127-a
Paola, F., Limonta, R., Malanchini, G., Luisa, P., & Filippo, P. D. (2026) · Case Reports in Cardiology · doi:10.1155/cric/3682992
Liu, J. F., Zhou, T., Lin, C., Zhang, N., Xie, Y., Yue, W., Luo, Q., Li, X., Sha, Z., Wu, G., et al. (2026) · Scientific Reports · doi:10.1038/s41598-026-44907-5
Zanon, F., & Marcantoni, L. (2026) · Springer eBooks · doi:10.1007/978-3-032-18018-6_1
von Felten, E., Breitenstein, A., Wiederkehr, C., Brix, T., Müller, A. F., Sepulcri, D., Jeger, R. V., & Höfer, D. (2026) · Heart Rhythm O2 · doi:10.1016/j.hroo.2026.07.030
Pacemaker Syndrome: A Narrative Review
Asad, M., Khaliq, K., Shah, A., Fiaz, M. A., & Perveen, A. (2026) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.70361
Atrial Fibrillation: Practical Approaches
Guo, H., Bajwa, O. A., & Olshansky, B. (2001) · doi:10.1007/978-1-4615-6601-4_46
Device Therapy for Bradycardias
Siu, C., & Tse, H. (2013) · Springer eBooks · doi:10.1007/978-1-4471-5316-0_45
Pacing to Prevent Atrial Fibrillation Recurrence: New Results
CHARLES, R. G. (2001) · Cardiac Electrophysiology Review · doi:10.1023/a:1011405521914
Pacing for Vasovagal Syncope: Real Efficacy or Placebo Effect?
Sheldon, R. S. (2002) · Springer eBooks · doi:10.1007/978-88-470-2103-7_13
Quality of Life in Patients with Implantable Cardiac Devices
Bacior, B., Loster, M., & Klocek, M. (2012) · Springer eBooks · doi:10.1007/978-88-470-2769-5_7
Metadata
- Authors
- Connolly, S. J., Kerr, C. R., Gent, M., Roberts, R. S., Yusuf, S., Gillis, A. M., Sami, M. H., Talajic, M., Tang, A. S. L., Klein, G. J., Lau, C., & Newman, D. M.
- Affiliations
- McMaster University (CA)
- University of British Columbia (CA)
- University of Calgary (CA)
- McGill University (CA)
- Montreal Heart Institute (CA)
- University of Ottawa (CA)
- Western University (CA)
- University of Toronto (CA)
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2000-05-11
- Volume
- 342
- Issue
- 19
- Pages
- 1385-1391
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2332653577
- Cited by
- 775
- References
- 16
- Citations by year
- 2026: 8 · 2025: 9 · 2024: 8 · 2023: 16 · 2022: 14 · 2021: 14 · 2020: 21 · 2019: 19 · 2018: 23 · 2017: 15 · 2016: 26 · 2015: 25 · 2014: 23 · 2013: 28 · 2012: 35
- FWCI
- 31.24
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Health and Mental Health
- Keywords
- physiological pacing, ventricular pacing, dual-chamber pacemaker, atrial pacing, bradycardia, pacemaker implantation, stroke, cardiovascular mortality, atrial fibrillation, heart failure hospitalization, perioperative complications, symptomatic bradycardia
- MeSH terms
- Aged, Atrial Fibrillation, Bradycardia, Cardiac Pacing, Artificial, Cardiovascular Diseases, Female, Heart Block, Humans, Male, Pacemaker, Artificial, Risk, Stroke
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review