BACKGROUND: Implantable cardioverter-defibrillator (ICD) therapy has been shown to improve survival in patients with various heart conditions who are at high risk for ventricular arrhythmias. Whether benefit occurs in patients early after myocardial infarction is unknown. METHODS: We conducted the Defibrillator in Acute Myocardial Infarction Trial, a randomized, open-label comparison of ICD therapy (in 332 patients) and no ICD therapy (in 342 patients) 6 to 40 days after a myocardial infarction. We enrolled patients who had reduced left ventricular function (left ventricular ejection fraction, 0.35 or less) and impaired cardiac autonomic function (manifested as depressed heart-rate variability or an elevated average 24-hour heart rate on Holter monitoring). The primary outcome was mortality from any cause. Death from arrhythmia was a predefined secondary outcome. RESULTS: During a mean (+/-SD) follow-up period of 30+/-13 months, there was no difference in overall mortality between the two treatment groups: of the 120 patients who died, 62 were in the ICD group and 58 in the control group (hazard ratio for death in the ICD group, 1.08; 95 percent confidence interval, 0.76 to 1.55; P=0.66). There were 12 deaths due to arrhythmia in the ICD group, as compared with 29 in the control group (hazard ratio in the ICD group, 0.42; 95 percent confidence interval, 0.22 to 0.83; P=0.009). In contrast, there were 50 deaths from nonarrhythmic causes in the ICD group and 29 in the control group (hazard ratio in the ICD group, 1.75; 95 percent confidence interval, 1.11 to 2.76; P=0.02). CONCLUSIONS: Prophylactic ICD therapy does not reduce overall mortality in high-risk patients who have recently had a myocardial infarction. Although ICD therapy was associated with a reduction in the rate of death due to arrhythmia, that was offset by an increase in the rate of death from nonarrhythmic causes.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Despite data linking decreased HRV with increased mortality, randomized trials in patients stratified for ICD implantation based on this parameter failed to demonstrate the usefulness of HRV in predicting benefit from ICD therapy (Hohnloser et al., 2004;Steinbeck et al., 2009).”
From 2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry (2017) · cites this paper as Hohnloser et al., 2004
Citations
Cites
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_25 · Cited by 45,181
Nonparametric Estimation from Incomplete Observations
Kaplan, E. L., & Meier, P. (1958) · Journal of the American Statistical Association · doi:10.1080/01621459.1958.10501452 · Cited by 39,158
Evaluation of survival data and two new rank order statistics arising in its consideration.
Mantel, N. (1966) · PubMed · Cited by 7,519
Moss, A. J., Zareba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,902
Moss, A. J., Hall, W. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Klein, H., Levine, J. H., Saksena, S., Waldo, A. L., Wilber, D., et al. (1996) · New England Journal of Medicine · doi:10.1056/nejm199612263352601 · Cited by 4,165
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Rovere, M. T. L., Bigger, J. T., Marcus, F. I., Mortara, A., & Schwartz, P. J. (1998) · The Lancet · doi:10.1016/s0140-6736(97)11144-8 · Cited by 3,120
The DAVID Trial Investigators* (2002) · JAMA · doi:10.1001/jama.288.24.3115 · Cited by 2,056
Connolly, S. J., Gent, M., Roberts, R. S., Dorian, P., Roy, D., Sheldon, R. S., Mitchell, L. B., Green, M. S., Klein, G. J., & O’Brien, B. (2000) · Circulation · doi:10.1161/01.cir.101.11.1297 · Cited by 1,607
Self-citationBigger, J. T., Fleiss, J. L., Kleiger, R., Miller, J. P., & Rolnitzky, L. M. (1984) · Circulation · doi:10.1161/01.cir.69.2.250 · Cited by 1,286
Research works printed but not linked: 3
- Myerburg RJ, 1992, Circulation, 85, I
- Zuanetti G, 1999, Eur Heart J, 1, H52
- Mantel N, 1966, Cancer Chemother Rep, 50, 163
Cited by
Items 301–400 of 1,000
Goldenberg, I., Huang, D. T.-C., & Nielsen, J. C. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehz788 · Cited by 49
Chen, P., Zhang, W., Fan, X., Shi, X., Jiang, Y., Yan, L., Li, H., Wang, C., Han, L., Lu, X., et al. (2024) · Nano Today · doi:10.1016/j.nantod.2024.102157 · Cited by 48
Robbers, L. F. H. J., Delewi, R., Nijveldt, R., Hirsch, A., Beek, A. M., Kemme, M. J. B., van Beurden, Y. H., van der Laan, A. M., van der Vleuten, P. A., Tio, R. A., et al. (2013) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jet111 · Cited by 48
Cleland, J. G. F., Coletta, A. P., Yassin, A., Buga, L., Torabi, A., & Clark, A. L. (2009) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfp162 · Cited by 48
Groeneveld, P. W., Farmer, S. A., Suh, J. J., Matta, M. A., & Yang, F. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.01.038 · Cited by 48
Betts, T. R., Sadarmin, P. P., Tomlinson, D. R., Rajappan, K., Wong, K. C., de Bono, J. P., & Bashir, Y. (2013) · EP Europace · doi:10.1093/europace/eus427 · Cited by 48
Reducing the Risk of Sudden Death in Heart Failure With β-Blockers
Adamson, P. B., & Gilbert, E. M. (2006) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2006.08.213 · Cited by 48
Joshi, S. B., Connelly, K. A., Jiménez‐Juan, L., Hansen, M., Kirpalani, A., Dorian, P., Mangat, I., Al‐Hesayen, A., Crean, A. M., Wright, G. A., et al. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-69 · Cited by 47
Self-citationSchuleri, K. H., Centola, M., Evers, K. S., Zviman, A., Evers, R. W., Lima, J. A. C., & Lardo, A. C. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-24 · Cited by 47
Earley, A., Persson, R., Garlitski, A. C., Balk, E. M., & Uhlig, K. (2014) · Annals of Internal Medicine · doi:10.7326/m13-1787 · Cited by 47
Biering‐Sørensen, T., Knappe, D., Pouleur, A., Claggett, B. L., Wang, P. J., Moss, A. J., Solomon, S. D., & Kutyifa, V. (2016) · Circulation Cardiovascular Imaging · doi:10.1161/circimaging.116.005096 · Cited by 47
Sex Disparities in Sudden Cardiac Death
Butters, A., Arnott, C. G., Sweeting, J., Winkel, B. G., Semsarian, C., & Ingles, J. (2021) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.121.009834 · Cited by 47
Sudden cardiac death: The role of risk stratification
Kusmirek, S., & Gold, M. R. (2007) · American Heart Journal · doi:10.1016/j.ahj.2007.01.024 · Cited by 47
Zaman, S. J., Taylor, A. J., Stiles, M. K., Chow, C. K., & Kovoor, P. (2016) · Heart Lung and Circulation · doi:10.1016/j.hlc.2016.04.007 · Cited by 46
Lunati, M., Gasparini, M., Santini, M., Landolina, M., Perego, G. B., Pappone, C., Marzegalli, M., ARGIOLAS, C., Murthy, A., Valsecchi, S., et al. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00923.x · Cited by 45
Risk Stratification of Sudden Cardiac Death After Acute Myocardial Infarction
Bui, A. H., & Waks, J. W. (2018) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2018.090201 · Cited by 45
Composite Endpoints for Clinical Trials: Current Perspectives
Kleist, P. (2007) · International Journal of Pharmaceutical Medicine · doi:10.2165/00124363-200721030-00001 · Cited by 45
(2011) · Der Kardiologe · doi:10.1007/s12181-011-0349-8 · Cited by 45
Risk Stratification Using T‐Wave Alternans: More Questions Waiting to be Answered
Hohnloser, S. H. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01205.x · Cited by 45
Self-citationDuray, G. Z., Schmitt, J., Richter, S., Israel, C. W., & Hohnloser, S. H. (2009) · EP Europace · doi:10.1093/europace/eup246 · Cited by 44
Self-citationBenefits of the Implantable Cardioverter-Defibrillator
Epstein, A. E. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.06.035 · Cited by 44
Jauhar, S., & Slotwiner, D. J. (2004) · New England Journal of Medicine · doi:10.1056/nejme048303 · Cited by 44
Levy, W. C., Li, Y., Reed, S. D., Zile, M. R., Shadman, R., Dardas, T., Whellan, D. J., Schulman, K. A., Ellis, S. J., Neilson, M., et al. (2016) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2016.09.006 · Cited by 43
Recommendations for the use of electrophysiological study: Update 2018
Mureşan, L., Cismaru, G. L., Martins, R. P., Bataglia, A., Roşu, R., Puiu, M., Guşetu, G., Mada, R. O., Muresan, C., Ispas, D. R., et al. (2018) · Hellenic Journal of Cardiology · doi:10.1016/j.hjc.2018.09.002 · Cited by 43
de Lepper, A. G. W., Buck, C. M. A., Veer, M. V. ’., Huberts, W., van de Vosse, F. N., & Dekker, L. (2022) · Journal of The Royal Society Interface · doi:10.1098/rsif.2022.0317 · Cited by 44
Kusumoto, F. M., Calkins, H. G., BOEHMER, J. P., Buxton, A. E., Chung, M. K., Gold, M. R., Hohnloser, S. H., Indik, J. H., Lee, R., Mehra, M. R., et al. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.03.041 · Cited by 43
Self-citationCost-effectiveness of implantable cardioverter defibrillators in patients ≥65 years of age
Sanders, G. D., Kong, M. H., Al‐Khatib, S. M., & Peterson, E. D. (2010) · American Heart Journal · doi:10.1016/j.ahj.2010.04.021 · Cited by 43
Gardiwal, A., Yu, H. H., Oswald, H., Luesebrink, U., Ludwig, A., Pichlmaier, A. M., Drexler, H., & Klein, G. (2008) · EP Europace · doi:10.1093/europace/eun019 · Cited by 43
Duray, G. Z., Richter, S., Manegold, J. C., Israel, C. W., Grönefeld, G., & Hohnloser, S. H. (2005) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-006-5200-y · Cited by 43
Self-citationThe Role of the Wearable Cardioverter Defibrillator in Clinical Practice
Chung, M. K. (2014) · Cardiology Clinics · doi:10.1016/j.ccl.2013.11.002 · Cited by 42
Sex-related similarities and differences in responses to heart failure therapies
Chyou, J. Y., Qin, H., Butler, J., Voors, A. A., & Lam, C. S. P. (2024) · Nature Reviews Cardiology · doi:10.1038/s41569-024-00996-1 · Cited by 41
Causes of death and re‐hospitalization in cardiogenic shock
Jeger, R. V., Assmann, S. F., Yehudai, L., Ramanathan, K., Farkouh, M. E., & Hochman, J. S. (2007) · Acute Cardiac Care · doi:10.1080/17482940601178039 · Cited by 41
Leong, D. P., Hoogslag, G. E., Piers, S. R. D., Höke, U., Thijssen, J., Marsan, N. A., Schalij, M. J., Zeppenfeld, K., Bax, J. J., & Delgado, V. (2015) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2014.12.012 · Cited by 41
The Significance of Shocks in Implantable Cardioverter Defibrillator Recipients
Li, A. C., Kaura, A., Sunderland, N. P., Dhillon, P. S., & Scott, P. A. (2016) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2016.12.2 · Cited by 41
Development of the Implantable Cardioverter-Defibrillator
Maron, B. J., Estes, N. A. M., Rowin, E. J., Maron, M. S., & Reynolds, M. R. (2023) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.04.056 · Cited by 40
Sudden Death Risk-Stratification in 2018–2019: The Old and the New
Zaman, S. J., Goldberger, J. J., & Kovoor, P. (2018) · Heart Lung and Circulation · doi:10.1016/j.hlc.2018.08.027 · Cited by 40
Predictors of Sudden Cardiac Death in High-Risk Patients Following a Myocardial Infarction
Docherty, K. F., Ferreira, J. P., Sharma, A., Girerd, N., Gregson, J., Duarte, K., Petrie, M. C., Jhund, P. S., Dickstein, K., Pfeffer, M. A., et al. (2020) · European Journal of Heart Failure · doi:10.1002/ejhf.1694 · Cited by 40
Steín, K. M. (2008) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2007.10.001 · Cited by 40
Adverse Experiences With Implantable Defibrillators in Oregon Hospices
Fromme, E. K., Stewart, T. L., Jeppesen, M., & Tolle, S. W. (2010) · American Journal of Hospice and Palliative Medicine® · doi:10.1177/1049909110390505 · Cited by 40
Ventricular arrhythmias in acute coronary syndromes—mechanisms and management
Thomas, D., Jex, N., & Thornley, A. R. (2017) · Continuing Cardiology Education · doi:10.1002/cce2.51 · Cited by 40
Insertable cardiac monitors: current indications and devices
Sakhi, R., Theuns, D. A. M. J., Szili-Torok, T., & Yap, S.-C. (2019) · Expert Review of Medical Devices · doi:10.1080/17434440.2018.1557046 · Cited by 39
PASSMAN, R. S., & Goldberger, J. J. (2012) · Circulation · doi:10.1161/circulationaha.111.023879 · Cited by 39
Piccini, J. P., Al‐Khatib, S. M., Hellkamp, A. S., Anstrom, K. J., Poole, J. E., Mark, D. B., Lee, K. L., & Bardy, G. H. (2010) · Heart Rhythm · doi:10.1016/j.hrthm.2010.11.033 · Cited by 39
Veltmann, C., Winter, S., Duncker, D., Jungbauer, C. G., Wäßnig, N. K., Geller, J. C., Erath, J. W., Göing, O., Perings, C. A., Ulbrich, M., et al. (2020) · Clinical Research in Cardiology · doi:10.1007/s00392-020-01657-2 · Cited by 39
Can microvolt T-wave alternans testing reduce unnecessary defibrillator implantation?
Armoundas, A. A., Hohnloser, S. H., Ikeda, T., & Cohen, R. J. (2005) · Nature Clinical Practice Cardiovascular Medicine · doi:10.1038/ncpcardio0323 · Cited by 39
Self-citationThe Electrocardiogram as a Prognostic Tool for Predicting Major Cardiac Events
Lanza, G. A. (2007) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2007.03.003 · Cited by 39
Sweeney, M. O. (2010) · Circulation · doi:10.1161/circulationaha.110.000208 · Cited by 39
Nilsson, K. R., Al‐Khatib, S. M., Zhou, Y., Pieper, K. S., White, H. D., Maggioni, A. P., Køber, L., Granger, C. B., Lewis, E. F., McMurray, J. J. V., et al. (2010) · Heart · doi:10.1136/hrt.2009.180182 · Cited by 38
Current Evidence Base for Use of the Implantable Cardioverter–Defibrillator
Hohnloser, S. H., & Israel, C. W. (2013) · Circulation · doi:10.1161/circulationaha.112.000547 · Cited by 38
Self-citationRibeiro, R. A., Stella, S. F., Camey, S. A., Zimerman, L. I., Pimentel, M., Rohde, L. E. P., & Polanczyk, C. A. (2009) · Value in Health · doi:10.1111/j.1524-4733.2009.00608.x · Cited by 38
Primary and secondary prevention of sudden cardiac death: who should get an ICD?
Santini, M., Lavalle, C., & Ricci, R. P. (2007) · Heart · doi:10.1136/hrt.2006.095190 · Cited by 38
de Godoy, M. F., Takakura, I. T., Corrêa, P. R., Machado, M. D. N., Miranda, R. C., & Brandi, A. C. (2009) · PubMed · Cited by 38
Raphael, C. E., Finegold, J. A., Barron, A. J., Whinnett, Z. I., Mayet, J., Linde, C., Cleland, J. G. F., Levy, W. C., & Francis, D. P. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv102 · Cited by 37
Changing Nature of Cardiac Interventions in Older Adults
Dodson, J. A., & Maurer, M. S. (2011) · Aging Health · doi:10.2217/ahe.11.12 · Cited by 37
Setoguchi, S., Stevenson, L. W., Stewart, G. C., Bhatt, D. L., Epstein, A. E., Desai, M., Williams, L. A., & Chen, C. (2014) · BMJ · doi:10.1136/bmj.g2866 · Cited by 37
Chung, E. S., Dan, D., Solomon, S. D., Bank, A. J., Pastore, J., Iyer, A. S., Berger, R. D., Franklin, J. O., Jones, G., Machado, C., et al. (2010) · Circulation Heart Failure · doi:10.1161/circheartfailure.110.945881 · Cited by 37
Current Pacemaker and Defibrillator Therapy
Trappe, H., & Gummert, J. F. (2011) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.2011.0372 · Cited by 37
Sudden Cardiac Death After Non–ST-Segment Elevation Acute Coronary Syndrome
Hess, P. L., WOJDYLA, D. M., Al‐Khatib, S. M., Lokhnygina, Y. V., Wallentin, L. C., Armstrong, P. W., Roe, M. T., Ohman, E. M., Harrington, R. A., Alexander, J. H., et al. (2016) · JAMA Cardiology · doi:10.1001/jamacardio.2015.0359 · Cited by 37
Faxén, J., Jernberg, T., Hollenberg, J., Gadler, F., Herlitz, J., & Szummer, K. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.10.033 · Cited by 36
Yehya, A., Batista, J. L., Sauer, A. J., Davis, J. D., Ibrahim, N. E., Tung, R. H., Bozkurt, B., Fonarow, G. C., & Al‐Khatib, S. M. (2024) · JACC Heart Failure · doi:10.1016/j.jchf.2024.09.014 · Cited by 36
Sudden cardiac death: A review focused on cardiovascular imaging
Conte, L., Nicastro, I., Barletta, V., Bello, V., & Fabiani, I. (2014) · Journal of Cardiovascular Echography · doi:10.4103/2211-4122.135611 · Cited by 36
2019 ESC Guidelines for the diagnosis and management of chronic coronary syndromes
(2020) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2020.05.011 · Cited by 36
Current and Emerging Antiarrhythmic Drug Therapy for Ventricular Tachycardia
Williams, E. S., & Viswanathan, M. N. (2013) · Cardiology and Therapy · doi:10.1007/s40119-013-0012-5 · Cited by 36
Biering‐Sørensen, T., Olsen, F. J., Storm, K. S., Fritz‐Hansen, T., Olsen, N. T., Jøns, C., Vinther, M., Søgaard, P., & Risum, N. (2016) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jew066 · Cited by 36
Prevention of Sudden Cardiac Death: Lessons From Recent Controlled Trials
Richter, S., Duray, G. Z., Grönefeld, G., Israel, C. W., & Hohnloser, S. H. (2005) · Circulation Journal · doi:10.1253/circj.69.625 · Cited by 36
Self-citationImplantable Cardioverter- Defibrillator Therapy in Clinical Practice
Cesario, D. A., & Dec, G. W. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.09.077 · Cited by 36
Smit, M. D., van Dessel, P. F. H. M., Rienstra, M., Nieuwland, W., Wiesfeld, A. C. P., Tan, E. S., Anthonio, R. L., van Veldhuisen, D. J., & Gelder, I. C. V. (2006) · EP Europace · doi:10.1093/europace/eul081 · Cited by 36
The Year in Heart Failure 2005
Massie, B. M., & Force, T. L. (2006) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2006.01.001 · Cited by 36
Fan, S., Lyon, C. E., Savage, P. D., Ozonoff, A., Ades, P. A., & Balady, G. J. (2009) · Journal of Cardiopulmonary Rehabilitation and Prevention · doi:10.1097/hcr.0b013e31819276f7 · Cited by 35
Sudden Cardiac Death in Heart Failure
Klein, L., & Hsia, H. H. (2013) · Cardiology Clinics · doi:10.1016/j.ccl.2013.09.008 · Cited by 35
Ventricular Fibrillation: triggers, Mechanisms and Therapies
Krummen, D. E., Ho, G., Villongco, C., Hayase, J. H., & Schricker, A. A. (2016) · Future Cardiology · doi:10.2217/fca-2016-0001 · Cited by 35
Prophylactic Defibrillator Implantation — Toward an Evidence-Based Approach
Kadish, A. H. (2005) · New England Journal of Medicine · doi:10.1056/nejme048351 · Cited by 35
Epstein, A. E., Baessler, C. A., Curtis, A. B., Estes, N. A. M., Gersh, B. J., Grubb, B., & Mitchell, L. B. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.01.015 · Cited by 34
Ezekowitz, J. A., Armstrong, P. W., Granger, C. B., Théroux, P., Stebbins, A. S., Kim, R. J., & Patel, M. R. (2010) · American Heart Journal · doi:10.1016/j.ahj.2010.05.035 · Cited by 34
Rupp, H. (2009) · Advances in Therapy · doi:10.1007/s12325-009-0045-2 · Cited by 34
Henyan, N. N., White, C. M., Gillespie, E. L., Smith, K. J., Coleman, C. I., & Kluger, J. (2006) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.2006.01713.x · Cited by 34
Skhirtladze, K., Birkenberg, B., Mora, B., Moritz, A., Ince, I., Ankersmit, H. J., Szeinlechner, B., & Dworschak, M. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181953d4c · Cited by 34
Triedman, J. K. (2008) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.108.805903 · Cited by 34
Amara, N., Bovéda, S., Defaye, P., Klug, D., Treguer, F., Amet, D., Perier, M., Gras, D., Algalarrondo, V., Bouzeman, A., et al. (2017) · EP Europace · doi:10.1093/europace/euw379 · Cited by 34
The implantable cardioverter–defibrillator: An update
Miller, J. D., Yousuf, O. K., & Berger, R. D. (2015) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2015.01.015 · Cited by 34
Naccarelli, G. V., & Lukas, M. A. (2005) · Clinical Cardiology · doi:10.1002/clc.4960280403 · Cited by 34
Sudden cardiac death and implantable cardioverter defibrillators: two modern epidemics?
Katritsis, D. G., & Josephson, M. E. (2012) · EP Europace · doi:10.1093/europace/eus001 · Cited by 33
Battipaglia, I., Barone, L., Mariani, L., Infusino, F., Remoli, R., Careri, G., Pinnacchio, G., Tarzia, P., LANZA, G., & Crea, F. (2010) · EP Europace · doi:10.1093/europace/euq408 · Cited by 33
The Limitations of Symptom-based Heart Failure Management
Papadimitriou, L., Moore, C. K., Butler, J., & Long, R. C. (2019) · Cardiac failure review · doi:10.15420/cfr.2019.3.2 · Cited by 33
Reported mortality with rotating sheaths vs. laser sheaths for transvenous lead extraction
Diaz, C. L., Guo, X., Whitman, I. R., Marcus, G. M., Pellegrini, C. N., Beygui, R. E., Lee, S. Y., & Lee, B. K. (2019) · EP Europace · doi:10.1093/europace/euz238 · Cited by 33
Sinergy between drugs and devices in the fight against sudden cardiac death and heart failure
Boriani, G., Ponti, R. D., Guerra, F., Palmisano, P., Zanotto, G., D’Onofrio, A., & Ricci, R. P. (2020) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwaa015 · Cited by 33
Chen, C.-Y., Stevenson, L. W., Stewart, G. C., Bhatt, D. L., Desai, M., Seeger, J. D., Williams, L. A., Jalbert, J. J., & Setoguchi, S. (2015) · BMJ · doi:10.1136/bmj.h3529 · Cited by 33
Vijgen, J. M., Botto, G., Camm, A. J., Höijer, C. J., Jung, W., Heuzey, J. L., Lubiński, A., Norekvål, T. M., Santomauro, M., Schalij, M. J., et al. (2010) · European Journal of Cardiovascular Nursing · doi:10.1016/j.ejcnurse.2010.01.001 · Cited by 33
Yap, Y. G., Duong, T., Bland, M., Malík, M., Torp-Pedersen, C. T., Køber, L., Gallagher, M. M., & Camm, A. J. (2007) · Heart · doi:10.1136/hrt.2006.102186 · Cited by 33
Healey, J. S., Hohnloser, S. H., Glikson, M., NEUZNER, J., Viñolas, X., Mabo, P., Kautzner, J., O’Hara, G. E., Erven, L. V., Gadler, F., et al. (2012) · American Heart Journal · doi:10.1016/j.ahj.2012.05.007 · Cited by 32
Self-citationUse of cardiac radionuclide imaging to identify patients at risk for arrhythmic sudden cardiac death
Kelesidis, I., & Travin, M. I. (2011) · Journal of Nuclear Cardiology · doi:10.1007/s12350-011-9482-9 · Cited by 32
Brüllmann, S., Dichtl, W., Paoli, U., Haegeli, L. M., Schmied, C. M., Steffel, J., Brunckhorst, C., Hintringer, F., Seifert, B., Duru, F., et al. (2011) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2011.10.030 · Cited by 32
Khumri, T. M., Nayyar, S., Idupulapati, M., Magalski, A., Stoner, C. N., Kusnetzky, L. L., Kosiborod, M., Spertus, J. A., & Main, M. L. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.05.045 · Cited by 32
Liang, J. J., Hodge, D. O., Mehta, R. A., Russo, A. M., Prasad, A., & Cha, Y. (2014) · EP Europace · doi:10.1093/europace/euu138 · Cited by 32
Wearable Cardioverter-defibrillators for the Prevention of Sudden Cardiac Death: A Meta-analysis
Nguyen, E., Weeda, E. R., Kohn, C. G., D'Souza, B. A., Russo, A. M., Noreika, S., & Coleman, C. I. (2018) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2018.090506 · Cited by 32
Anderson, R. D., Ariyarathna, N., Lee, G., Virk, S. A., Trivic, I., Campbell, T. G., Chow, C. K., Kalman, J. M., & Kumar, S. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.05.026 · Cited by 32
Søholm, H., Lønborg, J., Andersen, M. J., Vejlstrup, N. G., Engstrøm, T., Møller, J. E., & Hassager, C. (2014) · European Heart Journal Acute Cardiovascular Care · doi:10.1177/2048872614556000 · Cited by 32
Cleland, J. G. F., Coletta, A. P., Clark, A. L., & Cullington, D. (2009) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfp071 · Cited by 32
Harrington, J., Petrie, M. C., Anker, S. D., Bhatt, D. L., Jones, W. S., Udell, J. A., Hernandez, A. F., & Butler, J. (2022) · JAMA Cardiology · doi:10.1001/jamacardio.2022.2847 · Cited by 31
Pöss, J., Jacobshagen, C., Ukena, C., & Böhm, M. (2010) · Clinical Research in Cardiology · doi:10.1007/s00392-010-0176-0 · Cited by 31
Metadata
- Authors
- Hohnloser, S. H., Kuck, K. H., Dorian, P., Roberts, R. S., Hampton, J. R., Hatala, R., Fain, E., Gent, M., & Connolly, S. J.
- Affiliations
- Goethe University Frankfurt (DE)
- St. Michael's Hospital (CA)
- University of Nottingham (GB)
- McMaster University (CA)
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2004-12-09
- Volume
- 351
- Issue
- 24
- Pages
- 2481-2488
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2109205604
- Cited by
- 1,519
- References
- 22
- Citations by year
- 2026: 23 · 2025: 24 · 2024: 32 · 2023: 39 · 2022: 50 · 2021: 54 · 2020: 53 · 2019: 59 · 2018: 52 · 2017: 93 · 2016: 67 · 2015: 75 · 2014: 70 · 2013: 93 · 2012: 96
- FWCI
- 52.71
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- implantable cardioverter-defibrillator, acute myocardial infarction, all-cause mortality, left ventricular dysfunction, heart rate variability
- MeSH terms
- Adult, Aged, Arrhythmias, Cardiac, Female, Follow-Up Studies, Humans, Male, Middle Aged, Myocardial Infarction, Risk, Stroke Volume, Survival Analysis, Death, Sudden, Cardiac, Defibrillators, Implantable, Ventricular Dysfunction, Left
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.