The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Cardiac-Resynchronization Therapy for Mild-to-Moderate Heart Failure
Abstract
BACKGROUND: Cardiac-resynchronization therapy (CRT) benefits patients with left ventricular systolic dysfunction and a wide QRS complex. Most of these patients are candidates for an implantable cardioverter-defibrillator (ICD). We evaluated whether adding CRT to an ICD and optimal medical therapy might reduce mortality and morbidity among such patients. METHODS: We randomly assigned patients with New York Heart Association (NYHA) class II or III heart failure, a left ventricular ejection fraction of 30% or less, and an intrinsic QRS duration of 120 msec or more or a paced QRS duration of 200 msec or more to receive either an ICD alone or an ICD plus CRT. The primary outcome was death from any cause or hospitalization for heart failure. RESULTS: We followed 1798 patients for a mean of 40 months. The primary outcome occurred in 297 of 894 patients (33.2%) in the ICD-CRT group and 364 of 904 patients (40.3%) in the ICD group (hazard ratio in the ICD-CRT group, 0.75; 95% confidence interval [CI], 0.64 to 0.87; P<0.001). In the ICD-CRT group, 186 patients died, as compared with 236 in the ICD group (hazard ratio, 0.75; 95% CI, 0.62 to 0.91; P = 0.003), and 174 patients were hospitalized for heart failure, as compared with 236 in the ICD group (hazard ratio, 0.68; 95% CI, 0.56 to 0.83; P<0.001). However, at 30 days after device implantation, adverse events had occurred in 124 patients in the ICD-CRT group, as compared with 58 in the ICD group (P<0.001). CONCLUSIONS: Among patients with NYHA class II or III heart failure, a wide QRS complex, and left ventricular systolic dysfunction, the addition of CRT to an ICD reduced rates of death and hospitalization for heart failure. This improvement was accompanied by more adverse events. (Funded by the Canadian Institutes of Health Research and Medtronic of Canada; ClinicalTrials.gov number, NCT00251251.).
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Patients with T2DM did not experience a higher rate of complications related to device implantation, including infection.170”
From Type 2 diabetes mellitus and heart failure: A position statement from the Heart Failure Association of the European Society of Cardiology (2018) · cites this paper as [170]
In the citing paper
“Also, subgroup analysis of the RAFT trial showed that the benefit of CRT-D was similar in patients with and without T2DM.170”
From Type 2 diabetes mellitus and heart failure: A position statement from the Heart Failure Association of the European Society of Cardiology (2018) · cites this paper as [170]
Citations
Cites
Moss, A. J., Zaręba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,885
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart Failure
Cleland, J. G. F., Daubert, J., Erdmann, E., Freemantle, N., Gras, D., KAPPENBERGER, L. J., & Tavazzi, L. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa050496 · Cited by 6,300
Bristow, M. R., Saxon, L. A., Boehmer, J., Krueger, S., Kass, D. A., De Marco, T., Carson, P., DiCarlo, L., DeMets, D., White, B. G., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa032423 · Cited by 5,812
Cardiac Resynchronization in Chronic Heart Failure
Abraham, W. T., Fisher, W. G., Smith, A. L., Delurgio, D. B., Leon, A. R., Loh, E., Kocovic, D. Z., Packer, M., Clavell, A. L., Hayes, D. L., et al. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013168 · Cited by 4,648
ACC/AHA 2005 Guideline Update for the Diagnosis and Management of Chronic Heart Failure in the Adult
Hunt, S. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.08.022 · Cited by 4,137
CARDIAC RESYNCHRONIZATION IN CHRONIC HEART FAILURE
Braham, W. I. T. A., Isher, W. E. G. F., Mith, L. S., Elurgio, D. A. B. D., Eon, A. N. R. L., Oh, E., Ocovic, D. U. Z. K., Acker, M. G., Lavell, L. C., Ayes, D. A. L. H., et al. (2002) · Cited by 3,808
Hunt, S. A., Abraham, W. T., Chin, M. H., Feldman, A. M., Francis, G. S., Ganiats, T. G., Jessup, M. L., Konstam, M. A., MANCINI, D. M., Michl, K., et al. (2009) · Circulation · doi:10.1161/circulationaha.109.192065 · Cited by 3,739
Cardiac-Resynchronization Therapy for the Prevention of Heart-Failure Events
Moss, A. J., Hall, W. J., Cannom, D. S., Klein, H., Brown, M. W., Daubert, J. P., Estes, N. A. M., Foster, E., Greenberg, H., Higgins, S. L., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0906431 · Cited by 3,157
Cazeau, S., Leclercq, C., Lavergne, T., Walker, S., Varma, C., Linde, C. M., Garrigue, S., KAPPENBERGER, L. J., Haywood, G. A., Santini, M., et al. (2001) · New England Journal of Medicine · doi:10.1056/nejm200103223441202 · Cited by 2,718
Flagged first, then by citations
Research works printed but not linked: 1
- Chan KL, 2003, Can J Cardiol, 19, 387
Cited by
Sorted by citations
Items 801–900 of 1,000
Goldenberg, I., Aktaş, M. K., Zaręba, W., Huang, D. T.-C., Rosero, S. Z., Younis, A., McNitt, S. A., Stockburger, M. A., Steinberg, J. S., Buttar, R. S., et al. (2023) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2023.09.018 · Cited by 10
Medical Management and Device-Based Therapies in Chronic Heart Failure
Nguyen, A. H., Hurwitz, M., Abraham, J. A., Blumer, V. L., Flanagan, M. C., Garan, A. R., Kanwar, M. K., Kataria, R., Kennedy, J. L. W., Kochar, A., et al. (2023) · Journal of the Society for Cardiovascular Angiography & Interventions · doi:10.1016/j.jscai.2023.101206 · Cited by 10
Lucà, F., Pavan, D., Gulizia, M. M., Manes, M. T., Abrignani, M. G., Benedetto, F. A., Bisceglia, I., Brigido, S., Caldarola, P., Calvanese, R., et al. (2024) · European Heart Journal Supplements · doi:10.1093/eurheartjsupp/suae034 · Cited by 10
Eitel, C., Wilton, S. B., Switzer, N. J., Cowan, K. F., & Exner, D. V. (2011) · EP Europace · doi:10.1093/europace/eur298 · Cited by 10
The Characteristics and Outcome of Infective Endocarditis Involving Implantable Cardiac Devices
Athan, E. (2014) · Current Infectious Disease Reports · doi:10.1007/s11908-014-0446-5 · Cited by 10
Past, present and future of cardiac resynchronization
Daubert, J., Cazeau, S., Ritter, P., & Leclercq, C. (2012) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2011.12.004 · Cited by 10
Kandari, F. A., Ērglis, A., Sweidan, R., Dannheimer, I., Sepši, M., Bénézet, J. M., Paďour, M., Naik, A. M., Escudero, J., West, T. M., et al. (2014) · IJC Heart & Vessels · doi:10.1016/j.ijchv.2014.06.008 · Cited by 10
Cardiac Resynchronization Therapy in Women
Costanzo, M. R. (2015) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2015.08.018 · Cited by 10
Radionuclide Assessment of Left Ventricular Dyssynchrony
Daya, H. A., Malhotra, S., & Soman, P. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.08.006 · Cited by 10
Device Therapies: New Indications and Future Directions
Kumar, P., & Schwartz, J. (2014) · Current Cardiology Reviews · doi:10.2174/1573403x1101141106121553 · Cited by 10
Kelli, H. M., Merchant, F. M., Mengistu, A., Casey, M., Hoskins, M. H., & El‐Chami, M. F. (2014) · Europe PMC (PubMed Central) · doi:10.11909/j.issn.1671-5411.2014.03.014 · Cited by 10
Cardiac resynchronisation therapy: current indications, management and basic troubleshooting
Rao, P., & Faddis, M. N. (2017) · Heart · doi:10.1136/heartjnl-2016-310656 · Cited by 10
Wytyczne ESC dotyczące stymulacji serca i terapii resynchronizującej w 2013 roku
Suplement, K. P. (2013) · Kardiologia Polska · doi:10.5603/kp.2013.0182 · Cited by 10
Hadwiger, M., Frielitz, F., Eisemann, N., Elsner, C., Dagres, N., Hindricks, G., & Katalinic, A. (2020) · Applied Health Economics and Health Policy · doi:10.1007/s40258-020-00571-y · Cited by 10
Röger, S., Borggrefe, M., & Kuschyk, J. (2015) · Europe PMC (PubMed Central) · doi:10.4022/jafib.1081 · Cited by 10
Zavadovsky, K. V., Саушкин, В. В., Varlamova, Y. V., Mishkina, A. I., Shipulin, V. V., Lebedev, D. I., & Popov, S. V. (2021) · Kardiologiia · doi:10.18087/cardio.2021.7.n1420 · Cited by 10
Salimian, S., Deyell, M. W., Andrade, J. G., Chakrabarti, S., Bennett, M. T., Krahn, A. D., & Hawkins, N. M. (2021) · Heart Rhythm O2 · doi:10.1016/j.hroo.2021.09.010 · Cited by 10
Chou, A., Larson, J. D., Deshmukh, A., CASCINO, T. M., Ghannam, M., Latchamsetty, R., Jongnarangsin, K., Oral, H., Morady, F., Bogun, F. M., et al. (2022) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15437 · Cited by 10
Reduction in Ventricular Tachyarrhythmia Burden in Patients Enrolled in the RAID Trial
Younis, A., Goldenberg, I., Farooq, S., Yavin, H. D., Daubert, J. P., Raitt, M. H., Mazur, A., Huang, D. T.-C., Mitchell, B. L., Rashtian, M. R., et al. (2022) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2022.02.018 · Cited by 10
Association of left ventricular remodeling with cardiac resynchronization therapy outcomes
Gold, M. R., Rickard, J., Daubert, C., Cerkvenik, J., & Linde, C. M. (2022) · Heart Rhythm · doi:10.1016/j.hrthm.2022.11.016 · Cited by 10
Biton, Y., Baman, J. R., & Polonsky, B. (2016) · Heart Failure Reviews · doi:10.1007/s10741-016-9542-y · Cited by 10
Anesthetic Management of Laser Lead Extraction for Cardiovascular Implantable Electronic Devices
Bhatia, M., Safavi‐Naeini, P., Razavi, M., Collard, C. D., Tolpin, D. A., & Anton, J. M. (2017) · Seminars in Cardiothoracic and Vascular Anesthesia · doi:10.1177/1089253217728581 · Cited by 10
Weber, D., Koller, M., Theuns, D. A. M. J., Yap, S., Kühne, M., Sticherling, C., Reichlin, T., Szili‐Törok, T., Osswald, S., & Schaer, B. A. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.01.033 · Cited by 10
Młynarska, A., Młynarski, R., Marcisz, C., & Golba, K. S. (2019) · Clinical Interventions in Aging · doi:10.2147/cia.s193577 · Cited by 10
Beaudoin, J., Szymonifka, J. D., Lavender, Z. R., Deaño, R. C., Zhou, Q. T., Januzzi, J. L., Singh, J. P., & Truong, Q. A. (2019) · Journal of Thoracic Disease · doi:10.21037/jtd.2019.11.66 · Cited by 10
The rationale for repurposing funny current inhibition for management of ventricular arrhythmia
Chakraborty, P., Rose, R. A., Nair, K., Downar, E., & Nanthakumar, K. (2020) · Heart Rhythm · doi:10.1016/j.hrthm.2020.07.031 · Cited by 10
Cardiac Resynchronization Therapy in Patients with Heart Failure
Palmiero, G., Florio, M. T., Rubino, M., Nesti, M., Marchel, M., & Russo, V. (2021) · Heart Failure Clinics · doi:10.1016/j.hfc.2021.01.010 · Cited by 10
Cardiac Resynchronization Therapy: Who Benefits?
Chinitz, J. S., d’Ávila, A., Goldman, M. E., Reddy, V. Y., & Dukkipati, S. R. (2014) · Annals of Global Health · doi:10.1016/j.aogh.2013.12.003 · Cited by 10
Camanho, L. E. M., Saad, E., Slater, C., Inácio, L. A. O., dos Santos, G. V., Dias, L. C., Spineti, P. P. D. M., & Mourilhe‐Rocha, R. (2019) · PLoS ONE · doi:10.1371/journal.pone.0225612 · Cited by 10
Device Therapy in Heart Failure
Gasparini, M., & Galimberti, P. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.048 · Cited by 10
A plea for the wider use of CRT-P in candidates for cardiac resynchronisation therapy
Daubert, J., Donal, E., & Linde, C. M. (2011) · Heart Failure Reviews · doi:10.1007/s10741-011-9277-8 · Cited by 9
Management of ACCF/AHA Stage C Heart Failure
Adigopula, S., Vivo, R. P., DePasquale, E. C., Nsair, A., & Deng, M. C.-H. K. (2013) · Cardiology Clinics · doi:10.1016/j.ccl.2013.09.012 · Cited by 9
brenyo, A. J., Goldenberg, I., Moss, A. J., Rao, M. C., McNitt, S. A., Huang, D. T.-C., Zaręba, W., & Barsheshet, A. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.04.018 · Cited by 9
One step forward, two steps back
Gheorghiade, M., & Ambrosy, A. P. (2011) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2010.205 · Cited by 9
Sciaraffia, E., Dagres, N., Hernández‐Madrid, A., Proclemer, A., TODD, D. M., & Blomström‐Lundqvist, C. (2014) · EP Europace · doi:10.1093/europace/euu395 · Cited by 9
Current treatment of heart failure with reduction of left ventricular ejection fraction
Aronow, W. S. (2016) · Expert Review of Clinical Pharmacology · doi:10.1080/17512433.2016.1242067 · Cited by 9
Parfieniuk‐Kowerda, A., Jaroszewicz, J., Łapiński, T. W., Łucejko, M., Maciaszek, M., Świderska, M., Grzeszczuk, A., Naumnik, B., Rowiński, M., & Flisiak, R. (2018) · Archives of Medical Science · doi:10.5114/aoms.2018.79958 · Cited by 9
Okumura, K., Sasaki, S., KUSANO, K. F., Mine, T., Fujii, K., Iwasa, A., Sunagawa, O., Yamabe, H., Takahashi, N., Ishii, S., et al. (2020) · Circulation Journal · doi:10.1253/circj.cj-19-1143 · Cited by 9
Contemporary ICD Use in Patients with Heart Failure
Spartalis, Μ., Nakajima, K., Zweiker, D., Spartalis, E. D., Iliopoulos, D., & Siasos, G. (2021) · Cardiology and Therapy · doi:10.1007/s40119-021-00225-7 · Cited by 9
Kronborg, M. B., Frausing, M. H. J. P., Svendsen, J. H., Johansen, J. B., Riahi, S., Haarbo, J., Poulsen, S. H., Eiskjær, H., Køber, L., Øvrehus, K. A., et al. (2023) · American Heart Journal · doi:10.1016/j.ahj.2023.05.011 · Cited by 9
Emerging Technologies in Cardiac Pacing
Vajapey, R. S., & Chung, M. K. (2023) · Annual Review of Medicine · doi:10.1146/annurev-med-051022-042616 · Cited by 9
Antoniou, N., Kalaitzoglou, M., Tsigkriki, L., Baroutidou, A., Tsaousidis, A., Koulaouzidis, G., Giannakoulas, G. A., & Charisopoulou, D. (2024) · Diagnostics · doi:10.3390/diagnostics14111178 · Cited by 9
Is Conduction System Pacing Going to Be the New Gold Standard for Cardiac Resynchronization Therapy?
Derndorfer, M., Κόλλιας, Γ., Martinek, M., & Pürerfellner, H. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13154320 · Cited by 9
Effect of Cardiac Resynchronization Therapy in Patients With Insulin-Treated Diabetes Mellitus
Szepietowska, B., Kutyifa, V., Ruwald, M. H., Solomon, S. D., Ruwald, A., McNitt, S. A., Polonsky, B., Thomas, S., Moss, A. J., & Zaręba, W. (2015) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2015.04.053 · Cited by 9
Whom Should I Refer in 2014 for Cardiac Resynchronization?
Manlucu, J., & TANG, A. S. L. (2014) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2014.03.019 · Cited by 9
Self-citationOne-year outcome after CRT implantation in NYHA class IV in comparison to NYHA class III patients
For The Mascot Study Group, Schuchert, A., Muto, C., Maounis, T., Frank, R., Ella, R. O., Polauck, A., & Padeletti, L. (2013) · Clinical Research in Cardiology · doi:10.1007/s00392-013-0558-1 · Cited by 9
Freeman, J. V., & Masoudi, F. A. (2012) · Heart Failure Clinics · doi:10.1016/j.hfc.2012.09.006 · Cited by 9
Current Attitudes on Cardiac Devices in Heart Failure: A Review
Marangou, J., & Paul, V. (2015) · Clinical Therapeutics · doi:10.1016/j.clinthera.2015.08.012 · Cited by 9
Cardiac Resynchronization Therapy
Ng, C. Y., & Heist, E. K. (2016) · Cardiology in Review · doi:10.1097/crd.0000000000000127 · Cited by 9
Electrocardiographic Parameters as Predictors of Response to Cardiac Resynchronization Therapy
Poposka, L., Boskov, V., Risteski, D., Taleski, J., Janusevski, F., Srbinovska, E., & Georgievska‐Ismail, L. (2018) · Open Access Macedonian Journal of Medical Sciences · doi:10.3889/oamjms.2018.092 · Cited by 9
Barbosa, R. S., Glass, L., Proietti, R., Burstein, B. J., AlTurki, A., Sobolik, L., Zhang, Z. D., Viart, G., Samuel, M., Shrier, A., et al. (2018) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2018.01.005 · Cited by 9
Coronary Sinus Lead Positioning
Róka, A., Borgquist, R., & Singh, J. P. (2016) · Heart Failure Clinics · doi:10.1016/j.hfc.2016.07.007 · Cited by 9
Ghanem, M. T., Allam, L. E., & Ahmed, R. S. (2019) · Indian Heart Journal · doi:10.1016/j.ihj.2019.04.010 · Cited by 9
Guo, Z., Liu, X., Cheng, X., Liu, C., Li, P., He, Y., Rao, R., Li, C., Chen, Y., Zhang, Y., et al. (2020) · Cardiology Research and Practice · doi:10.1155/2020/1257578 · Cited by 9
Wilkoff, B. L., Birnie, D. H., Gold, M. R., Hersi, A. S., Jacobs, S., Gerritse, B., Kusano, K., Leclercq, C., Müllens, W., & Filippatos, G. S. (2020) · ESC Heart Failure · doi:10.1002/ehf2.12914 · Cited by 9
Self-citationAlkharaza, A., Alharbi, M., Elsokkari, I., Doucette, S. P., Macintyre, C. J., Gray, C., AbdelWahab, A. M., Sapp, J. L., Gardner, M. J., & Parkash, R. (2020) · BMC Cardiovascular Disorders · doi:10.1186/s12872-020-01726-4 · Cited by 9
Self-citationHuang, D., Hua, W., Fang, Q., Yan, J., Su, Y., Liu, B., Xu, Y., Peng, Y., & POSCD-China Investigators (2020) · ESC Heart Failure · doi:10.1002/ehf2.13114 · Cited by 9
Aune, E., McMurray, J. J. V., Lundgren, P., Sattar, N. A., Israelsson, J., Nordberg, P., Herlitz, J. D., & Rawshani, A. (2022) · Scientific Reports · doi:10.1038/s41598-022-09510-4 · Cited by 9
Thoracoscopic Implantation of Epicardial Left Ventricular Lead for Cardiac Resynchronization Therapy
Kim, H. R., Lim, K., Park, S., Park, J. S., Choi, J.-H., Kwon, H.-J., Kim, J. Y., Chung, S., Jung, D.-S., Park, K.-M., et al. (2022) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd9050160 · Cited by 9
Brignole, M., Auricchio, A., Barón‐Esquivias, G., Bordachar, P., Boriani, G., Breithardt, O.-A., Cleland, J. G. F., Deharo, J.-C., Delgado, V., Elliot, P. M., et al. (2014) · Revista Española de Cardiología · doi:10.1016/j.recesp.2013.12.001 · Cited by 9
Kutyifa, V., Solomon, S. D., Bourgoun, M., Shah, A. M., Pouleur, A., Knappe, D., McNitt, S. A., Wang, P. J., Merkely, B. P., Pfeffer, M. A., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.11.007 · Cited by 9
Kutyifa, V., & Breithardt, O. A. (2012) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2011.12.024 · Cited by 9
Colchero, T., Arias, M. A., López-Sánchez, F. A., Pachón, M., Domínguez-Pérez, L., Puchol, A., Jiménez-López, J. I., Lázaro, M., Martínez-Mateo, V., & Padial, L. R. (2013) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2012.11.001 · Cited by 9
Predictors and outcomes of cardiac resynchronization therapy extended to the second generator
Li, X., Yang, D., Kusumoto, F. M., Shen, W.-K., Mulpuru, S. K., Zhou, S., Liang, J., Wu, G., Yang, M., Liu, J.-Q., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.09.002 · Cited by 9
Prognostic value of nutrition status in the response of cardiac resynchronization therapy
Álvarez, B. Á., García‐Seara, J., Rodríguez‐Mañero, M., Iglesias-Álvarez, D., Martínez‐Sande, J. L., Agra-Bermejo, R. M., López, X. A. F., Melchor, L. G., Gudé, F., Díaz‐Louzao, C., et al. (2018) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2018.04.001 · Cited by 9
Benefits of Multisite/Multipoint Pacing to Improve Cardiac Resynchronization Therapy Response
Thibault, B., Mondesert, B. A., Cadrin‐Tourigny, J., Dubuc, M., Macle, L., & Khairy, P. (2019) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2018.11.016 · Cited by 9
Effects of implantation of quadripolar left ventricular leads on CRT response
Erath, J. W., Vámos, M., Domokos, D., Benz, A. P., Bári, Z., Bógyi, P., Duray, G. Z., & Hohnloser, S. H. (2019) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-019-00545-8 · Cited by 9
Self-citationStassen, J., Khidir, M., Galloo, X., Hirasawa, K., Knuuti, J. M., Marsan, N. A., Delgado, V., van der Bijl, P., & Bax, J. J. (2022) · International Journal of Cardiology · doi:10.1016/j.ijcard.2022.02.020 · Cited by 9
What Have We Learned in the Last 20 Years About CRT Non-Responders?
Green, P. G., Herring, N., & Betts, T. R. (2022) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2021.12.019 · Cited by 9
Predictors of response to cardiac resynchronization therapy in chronic heart failure patients
Loutfi, M. I., Nawar, M. M., Eltahan, S. M., & elhoda, A. A. (2016) · The Egyptian Heart Journal · doi:10.1016/j.ehj.2016.01.001 · Cited by 9
Use of Cardiac Resynchronization Therapy Defibrillator in US Hospitals
Sandhu, A., Bao, H., Minges, K. E., Varosy, P. D., Borne, R. T., Zipse, M. M., Marzec, L., Peterson, P. N., Masoudi, F. A., & Bradley, S. M. (2019) · JAMA Cardiology · doi:10.1001/jamacardio.2019.1755 · Cited by 9
Manian, U., & Gula, L. J. (2016) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2016.03.009 · Cited by 9
Zimerman, A., Forno, A. D., Rohde, L. E. P., Ternes, C. M. P., Alves, F. D., Decker, S. R. R., da Silveira, A. D., Damiani, L. P., Filho, M. M., Costa, R. S., et al. (2025) · American Heart Journal · doi:10.1016/j.ahj.2025.06.002 · Cited by 8
Physiologic Pacing in Heart Failure
Chelu, M. G., Poole, J. E., & Ellenbogen, K. A. (2026) · New England Journal of Medicine · doi:10.1056/nejmra2415650 · Cited by 8
2025 Clinical practice guidelines for Bradyarrhythmias and conduction disorders
Revishvili, A. S. H., Glezer, M. G., Artyukhina, Е. А., Базаев, В. А., Batalov, R. E., Bockeria, L. A., Davtyan, K. V., Lebedev, D. S., Лебедева, В. К., Lyubimtseva, T. A., et al. (2026) · Russian Journal of Cardiology · doi:10.15829/1560-4071-2025-6669 · Cited by 8
Boriani, G., Ziacchi, M., Diemberger, I., Biffi, M., Martignani, C., & Leyva, F. (2014) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000147 · Cited by 8
Canterbury, A., & Saba, S. (2021) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2021.04.003 · Cited by 8
Mugnai, G., Donazzan, L., Tomasi, L., Piccoli, A., Cavedon, S., Manfrin, M., Bolzan, B., Perrone, C., Lavio, S., Rauhe, W., et al. (2022) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2022.10.001 · Cited by 8
Dyssynchronous Heart Failure: A Clinical Review
Dikdan, S. J., Co, M. L., & Pavri, B. B. (2022) · Current Cardiology Reports · doi:10.1007/s11886-022-01797-z · Cited by 8
Predictive Value of Global Longitudinal Strain by Left Ventricular Ejection Fraction
Medvedofsky, D. A., Arany‐Lao‐Kan, G., McNitt, S. A., Lang, R. M., Tung, R. H., Solomon, S. D., Merkely, B. P., Goldenberg, I., & Kutyifa, V. (2023) · ESC Heart Failure · doi:10.1002/ehf2.14193 · Cited by 8
Fudim, M., Dalgaard, F., Friedman, D. J., Abraham, W. T., Cleland, J. G. F., Curtis, A. B., Gold, M. R., Kutyifa, V., Linde, C. M., Ahmed, F. A., et al. (2023) · European Journal of Heart Failure · doi:10.1002/ejhf.3029 · Cited by 8
Self-citationOutcomes following cardiac resynchronisation therapy in older people
Safdar, N. Z., Kamalathasan, S., Gupta, A., Wren, J., Bird, R. A., Papp, D., Latto, R., Ahmed, A., Palin, V., Gierula, J., et al. (2023) · Age and Ageing · doi:10.1093/ageing/afad222 · Cited by 8
Tereshchenko, S. N., Жиров, И. В., Uskach, T. M., Saidova, M. A., Sp, G., Rimskaya, E. M., Николаевна, Н. С., Narusov, O. Y., Safiullina, A. A., Tereshchenko, A. S., et al. (2024) · Eurasian heart journal · doi:10.38109/2225-1685-2024-2-6-76 · Cited by 8
Cardiac Resynchronization Therapy in Patients with Atrial Fibrillation: A 2‐Year Follow‐Up Study
Eisen, A., Nevzorov, R., Goldenberg, G. R., KUZNITZ, H., Porter, A., GOLOVTZINER, G., Strasberg, B., & Haim, M. (2013) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12136 · Cited by 8
Lalonde, M., Wells, R. G., Birnie, D. H., Ruddy, T. D., & Wassenaar, R. W. (2014) · Medical Physics · doi:10.1118/1.4883881 · Cited by 8
Self-citationSchau, T., Koglek, W., Brandl, J., Seifert, M., Meyhöfer, J., Neuß, M., Grimm, G., Bitschnau, R., & Butter, C. (2012) · Clinical Research in Cardiology · doi:10.1007/s00392-012-0506-5 · Cited by 8
Implantable Cardiovascular Sensors and Computers: Interventional Heart Failure Strategies
Smith, S. A., & Abraham, W. T. (2012) · Current Cardiology Reports · doi:10.1007/s11886-012-0294-6 · Cited by 8
Dotsenko, O., Barsheshet, A., & Huang, D. T.-C. (2012) · Expert Review of Cardiovascular Therapy · doi:10.1586/erc.12.120 · Cited by 8
Sun, W., Li, C., Guo, J., Zhang, L.-X., Liu, R., Zhang, L., & Zhang, L. (2016) · Heart Failure Reviews · doi:10.1007/s10741-016-9550-y · Cited by 8
Developments in Cardiac Resynchronisation Therapy
Lewis, G. F., & Gold, M. R. (2015) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2015.04.02.122 · Cited by 8
Multisite Pacing for Cardiac Resynchronization Therapy: Promise and Pitfalls
Antoniadis, A. P., Behar, J. M., Claridge, S., Jackson, T., Sohal, M., & Rinaldi, C. A. (2016) · Current Cardiology Reports · doi:10.1007/s11886-016-0741-x · Cited by 8
Cardiac resynchronization therapy: results, challenges and perspectives for the future
Ståhlberg, M., Braunschweig, F., Gadler, F., Mortensen, L., Lund, L. H., & Linde, C. M. (2016) · Scandinavian Cardiovascular Journal · doi:10.1080/14017431.2016.1221530 · Cited by 8
Christie, S., Hiebert, B. M., Seifer, C. M., & Khoo, C. (2018) · Journal of Arrhythmia · doi:10.1002/joa3.12131 · Cited by 8
Henin, M., Ragy, H. I., Mannion, J., David, S., Refila, B., & Boles, U. (2020) · Cardiology Research · doi:10.14740/cr989 · Cited by 8
Gardner, R. S., D’Onofrio, A., Mark, G. E., Gras, D., Hu, Y. L., Veraghtert, S., & García‐Bolao, I. (2021) · ESC Heart Failure · doi:10.1002/ehf2.13192 · Cited by 8
Bottle, A., Faitna, P., Aylin, P. P., & Cowie, M. (2021) · ESC Heart Failure · doi:10.1002/ehf2.13357 · Cited by 8
Borgquist, R., Marinko, S., Platonov, P. G., Wang, L., Chaudhry, U. A., Brandt, J., & Mörtsell, D. (2023) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-022-01463-y · Cited by 8
Safety and efficacy of external electrical cardioversion in patients with left ventricular leads
Lüker, J., Bodman, G. V., Sultan, A., Brömsen, J., Akbulak, R. Ö., Schäffer, B., Schreiber, D., Hoffmann, B. A., Block, M. S., Willems, S., et al. (2014) · Clinical Research in Cardiology · doi:10.1007/s00392-014-0800-5 · Cited by 8
Newer Indications for ICD and CRT
Merriam, J. A., Rajendra, A. B., & Gold, M. R. (2014) · Cardiology Clinics · doi:10.1016/j.ccl.2013.12.004 · Cited by 8
Guglin, M. E., & Barold, S. S. (2011) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-011-9639-0 · Cited by 8
Metadata
- Authors
- Tang, A. S. L., Wells, G. A., Talajic, M., Arnold, M. O., Sheldon, R., Connolly, S., Hohnloser, S. H., Nichol, G., Birnie, D. H., Sapp, J. L., Yee, R., Healey, J. S., & Rouleau, J. L.
- Affiliations
- University of British Columbia (CA)
- Ottawa Heart Institute (CA)
- Montreal Heart Institute (CA)
- London Health Sciences Centre (CA)
- University of Calgary (CA)
- Hamilton Health Sciences (CA)
- Goethe University Frankfurt (DE)
- University of Washington (US)
- Queen Elizabeth II Health Sciences Centre (CA)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2010-12-16
- Volume
- 363
- Issue
- 25
- Pages
- 2385-2395
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2141895646
- Cited by
- 1,859
- References
- 28
- Citations by year
- 2026: 55 · 2025: 67 · 2024: 73 · 2023: 109 · 2022: 76 · 2021: 88 · 2020: 107 · 2019: 99 · 2018: 100 · 2017: 121 · 2016: 141 · 2015: 154 · 2014: 149 · 2013: 190 · 2012: 176
- FWCI
- 113.15
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Adelaide Research & Scholarship (AR&S) (University of Adelaide) (submittedVersion)
- Funders
- Canadian Institutes of Health Research
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
- Health Sciences › Medicine › Emergency Medicine › Cardiac Arrest and Resuscitation
- Keywords
- cardiac resynchronization therapy, implantable cardioverter-defibrillator, heart failure, wide QRS complex, left ventricular systolic dysfunction, mortality, heart failure hospitalization, device implantation complications, optimal medical therapy, left ventricular ejection fraction
- MeSH terms
- Aged, Cardiac Pacing, Artificial, Double-Blind Method, Electrocardiography, Female, Heart Failure, Hospitalization, Humans, Male, Middle Aged, Severity of Illness Index, Defibrillators, Implantable, Ventricular Dysfunction, Left, Kaplan-Meier Estimate, Intention to Treat Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review