The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
High-Frequency Oscillation in Early Acute Respiratory Distress Syndrome
Open accessAbstract
BACKGROUND: Previous trials suggesting that high-frequency oscillatory ventilation (HFOV) reduced mortality among adults with the acute respiratory distress syndrome (ARDS) were limited by the use of outdated comparator ventilation strategies and small sample sizes. METHODS: In a multicenter, randomized, controlled trial conducted at 39 intensive care units in five countries, we randomly assigned adults with new-onset, moderate-to-severe ARDS to HFOV targeting lung recruitment or to a control ventilation strategy targeting lung recruitment with the use of low tidal volumes and high positive end-expiratory pressure. The primary outcome was the rate of in-hospital death from any cause. RESULTS: On the recommendation of the data monitoring committee, we stopped the trial after 548 of a planned 1200 patients had undergone randomization. The two study groups were well matched at baseline. The HFOV group underwent HFOV for a median of 3 days (interquartile range, 2 to 8); in addition, 34 of 273 patients (12%) in the control group received HFOV for refractory hypoxemia. In-hospital mortality was 47% in the HFOV group, as compared with 35% in the control group (relative risk of death with HFOV, 1.33; 95% confidence interval, 1.09 to 1.64; P=0.005). This finding was independent of baseline abnormalities in oxygenation or respiratory compliance. Patients in the HFOV group received higher doses of midazolam than did patients in the control group (199 mg per day [interquartile range, 100 to 382] vs. 141 mg per day [interquartile range, 68 to 240], P<0.001), and more patients in the HFOV group than in the control group received neuromuscular blockers (83% vs. 68%, P<0.001). In addition, more patients in the HFOV group received vasoactive drugs (91% vs. 84%, P=0.01) and received them for a longer period than did patients in the control group (5 days vs. 3 days, P=0.01). CONCLUSIONS: In adults with moderate-to-severe ARDS, early application of HFOV, as compared with a ventilation strategy of low tidal volume and high positive end-expiratory pressure, does not reduce, and may increase, in-hospital mortality. (Funded by the Canadian Institutes of Health Research; Current Controlled Trials numbers, ISRCTN42992782 and ISRCTN87124254, and ClinicalTrials.gov numbers, NCT00474656 and NCT01506401.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
APACHE II: A severity of disease classification system
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Critical Care Medicine · doi:10.1097/00003246-198510000-00009 · Cited by 13,664
APACHE II-A Severity of Disease Classification System: Reply
Knaus, W. A., Draper, E. A., Wagner, D. P., & Zimmerman, J. E. (1986) · Critical Care Medicine · doi:10.1097/00003246-198608000-00028 · Cited by 13,376
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Acute Respiratory Distress Syndrome: The Berlin Definition
(2012) · JAMA · doi:10.1001/jama.2012.5669 · Cited by 8,731
Incidence and Outcomes of Acute Lung Injury
Rubenfeld, G. D., Caldwell, E., Peabody, E., Weaver, J., Martin, D. P., Neff, M., Stern, E. J., & Hudson, L. D. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa050333 · Cited by 3,684
Functional Disability 5 Years after Acute Respiratory Distress Syndrome
Herridge, M. S., Tansey, C. M., Matté, A., Tomlinson, G., Diaz-Granados, N., Cooper, A., Guest, C. B., Mazer, C. D., Mehta, S., Stewart, T. E., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1011802 · Cited by 2,847
Self-citation(2004) · New England Journal of Medicine · doi:10.1056/nejmoa032193 · Cited by 2,565
A Comparison of Four Methods of Weaning Patients from Mechanical Ventilation
Esteban, A., Frutos, F., Tobin, M. J., Alía, I., Solsona, J. F., Valverdu, V., Fernández, R., de la Cal, M. A., Benito, S., Tomás, R., et al. (1995) · New England Journal of Medicine · doi:10.1056/nejm199502093320601 · Cited by 1,549
Lung recruitment in patients with the acute respiratory distress syndrome.
Gattinoni, L., Caironi, P., Cressoni, M., Chiumello, D., Ranieri, V. M., Quintel, M., Russo, S., Patroniti, N., Cornejo, R., & Bugedo, G. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052052 · Cited by 1,548
Briel, M., Meade, M., Mercat, A., Brower, R. G., Talmor, D., Walter, S. D., Slutsky, A. S., Pullenayegum, E., Zhou, Q., Cook, D., et al. (2010) · JAMA · doi:10.1001/jama.2010.218 · Cited by 1,467
Self-citationMeade, M. O., Cook, D. J., Guyatt, G. H., Slutsky, A. S., Arabi, Y. M., Cooper, D. J., Davies, A. R., Hand, L. E., Zhou, Q., Thabane, L., et al. (2008) · JAMA · doi:10.1001/jama.299.6.637 · Cited by 1,370
Self-citationMercat, A., Richard, J.-C. M., Vielle, B., Jaber, S., Osman, D., Diehl, J.-L., Lefrant, J.-Y., Prat, G., Richecoeur, J., Nieszkowska, A., et al. (2008) · JAMA · doi:10.1001/jama.299.6.646 · Cited by 1,344
Tidal Hyperinflation during Low Tidal Volume Ventilation in Acute Respiratory Distress Syndrome
Terragni, P. P., Rosboch, G., Tealdi, A., Corno, E., Menaldo, E., Davini, O., Gandini, G., Herrmann, P., Mascia, L., Quintel, M., et al. (2007) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200607-915oc · Cited by 820
Self-citationHas Mortality from Acute Respiratory Distress Syndrome Decreased over Time?: A Systematic Review
Phua, J., Badia, J. R., Adhikari, N. K. J., Friedrich, J. O., Fowler, R. A., Singh, J. M., Scales, D. C., Stather, D. R., Li, A., Jones, A., et al. (2009) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200805-722oc · Cited by 727
Self-citationHigh-Frequency Oscillation for Acute Respiratory Distress Syndrome
Young, D., Lamb, S. E., Shah, S., MacKenzie, I., Tunnicliffe, W., Lall, R., Rowan, K., & Cuthbertson, B. H. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1215716 · Cited by 652
Derdak, S., Mehta, S., Stewart, T. E., Smith, T., Rogers, M., Buchman, T. G., Carlin, B., Lowson, S., Granton, J., & Respirator, T. M. O. V. F. A. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2108052 · Cited by 624
Self-citationTerragni, P. P., Del Sorbo, L., Mascia, L., Urbino, R., Martin, E. L., Birocco, A., Faggiano, C., Quintel, M., Gattinoni, L., & Ranieri, V. M. (2009) · Anesthesiology · doi:10.1097/aln.0b013e3181b764d2 · Cited by 577
Ventilator-induced lung injury: from the bench to the bedside
Tremblay, L. N., & Slutsky, A. S. (2006) · Intensive Care Medicine · doi:10.1007/s00134-005-2817-8 · Cited by 410
Self-citationVentilator-induced lung injury:from the bench to the bedside
Tremblay, L. N., & Slutsky, A. S. (2009) · Applied Physiology in Intensive Care Medicine · doi:10.1007/978-3-642-01769-8_60 · Cited by 328
Self-citationHigh-frequency oscillatory ventilation for adult respiratory distress syndrome-A pilot study
Fort, P., Farmer, C., Westerman, J., Johannigman, J., Beninati, W., Dolan, S., & Derdak, S. (1997) · Critical Care Medicine · doi:10.1097/00003246-199706000-00008 · Cited by 319
Prospective trial of high-frequency oscillation in adults with acute respiratory distress syndrome
Mehta, S., Lapinsky, S. E., Hallett, D. C., Merker, D., Groll, R. J., Cooper, A. B., MacDonald, R. J., & Stewart, T. E. (2001) · Critical Care Medicine · doi:10.1097/00003246-200107000-00011 · Cited by 263
Self-citationBollen, C. W., van Well, G. T. J., Sherry, T., Beale, R. J., Shah, S., Findlay, G., Monchi, M., Chiche, J.-D., Weiler, N., Uiterwaal, C. S., et al. (2005) · Critical Care · doi:10.1186/cc3737 · Cited by 249
Sud, S., Sud, M., Friedrich, J. O., Meade, M. O., Ferguson, N. D., Wunsch, H., & Adhikari, N. K. J. (2010) · BMJ · doi:10.1136/bmj.c2327 · Cited by 246
Self-citationImai, Y., Nakagawa, S., Ito, Y., Kawano, T., Slutsky, A. S., & Miyasaka, K. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.4.1836 · Cited by 170
Self-citationPrimary Pulmonary Sporotrichosis: A Case Report
Mehta, A., Budev, M. M., Ranes, J., & Shrestha, R. (2004) · Chest · doi:10.1378/chest.126.2.518 · Cited by 167
High-frequency oscillatory ventilation for adult respiratory distress syndrome
Froese, A. B. (1997) · Critical Care Medicine · doi:10.1097/00003246-199706000-00004 · Cited by 154
Ferguson, N. D., Chiche, J., Kacmarek, R. M., Hallett, D. C., Mehta, S., Findlay, G. P., Granton, J. T., Slutsky, A. S., & Stewart, T. E. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000155785.23200.9e · Cited by 119
Self-citationHager, D. N., Fessler, H., Kaczka, D. W., Shanholtz, C. B., Fuld, M., Simon, B. A., & Brower, R. G. (2007) · Critical Care Medicine · doi:10.1097/01.ccm.0000266586.04676.55 · Cited by 115
Rimensberger, P. C., Pache, J., McKerlie, C., Frndova, H., & Cox, P. N. (2000) · Intensive Care Medicine · doi:10.1007/s001340051242 · Cited by 108
Coakes, J. (2005) · Journal of the Intensive Care Society · doi:10.1177/175114370500600223 · Cited by 104
Guervilly, C., Forel, J.-M., Hraiech, S., Demory, D., Allardet-Servent, J., Adda, M., Barreau-Baumstark, K., Castanier, M., Papazian, L., & Roch, A. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182451b4a · Cited by 86
Feasibility of very high-frequency ventilation in adults with acute respiratory distress syndrome*
Fessler, H., Hager, D. N., & Brower, R. G. (2008) · Critical Care Medicine · doi:10.1097/01.ccm.0b013e318168fcab · Cited by 60
Muellenbach, R. M., Kredel, M., Said, H. M., Klosterhalfen, B., Zollhoefer, B., Wunder, C., Redel, A., Schmidt, M., Roewer, N., & Brederlau, J. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0708-x · Cited by 50
Sedeek, K., Takeuchi, M., Suchodolski, K., Vargas, S. O., Shimaoka, M., Schnitzer, J. J., & Kacmarek, R. M. (2003) · Anesthesiology · doi:10.1097/00000542-200311000-00016 · Cited by 37
Randomized Trials Stopped Early for Benefit: A Systematic Review
Montori, V. M., Devereaux, P. J., Adhikari, N. K. J., Burns, K. E. A., Eggert, C. H., Briel, M., Lacchetti, C., Leung, T. W., Darling, E., Bryant, D. M., et al. (2005) · JAMA · doi:10.1001/jama.294.17.2203 · Cited by 26
Self-citationHigh-frequency oscillation in adults: A utilization review*
Adhikari, N. K. J., Bashir, A., Lamontagne, F., Mehta, S., Ferguson, N. D., Zhou, Q. X., Hand, L. E., Czarnecka, K., Cook, D. J., Granton, J. T., et al. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e318226675e · Cited by 26
Self-citationMentzelopoulos, S. D., Malachias, S., Kokkoris, S., Roussos, C., & Zakynthinos, S. G. (2010) · Intensive Care Medicine · doi:10.1007/s00134-010-1822-8 · Cited by 21
Cited by
Surviving Sepsis Campaign: International guidelines for management of sepsis and septic shock: 2016.
Rhodes, A., Evans, L. E., Alhazzani, W., Levy, M. M., Antonelli, M., Ferrer, R., Kumar, A., Sevransky, J. E., Sprung, C. L., Nunnally, M. E., et al. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4683-6 · Cited by 6,621
Self-citationProne positioning in severe acute respiratory distress syndrome.
Guérin, C., Reignier, J., Richard, J.-C., Beuret, P., Gacouin, A., Boulain, T., Mercier, E., Badet, M., Mercat, A., Baudin, O., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1214103 · Cited by 4,040
Surviving Sepsis Campaign: International guidelines for management of sepsis and septic shock: 2016.
Rhodes, A., Evans, L. E., Alhazzani, W., Levy, M. M., Antonelli, M., Ferrer, R., Kumar, A., Sevransky, J. E., Sprung, C. L., Nunnally, M. E., et al. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002255 · Cited by 3,652
Self-citationAcute respiratory distress syndrome
Matthay, M. A., Zemans, R. L., Zimmerman, G. A., Arabi, Y. M., Beitler, J. R., Mercat, A., Herridge, M., Randolph, A. G., & Calfee, C. S. (2019) · Nature Reviews Disease Primers · doi:10.1038/s41572-019-0069-0 · Cited by 2,387
Self-citationVentilator-Induced Lung Injury
Slutsky, A. S., & Ranieri, V. M. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1208707 · Cited by 2,211
Self-citation
Metadata
- Authors
- Ferguson, N. D., Cook, D. J., Guyatt, G. H., Mehta, S., Hand, L., Austin, P., Zhou, Q., Matte, A., Walter, S. D., Lamontagne, F., Granton, J. T., Arabi, Y. M., Arroliga, A. C., Stewart, T. E., Slutsky, A. S., & Meade, M. O.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2013-02-28
- Volume
- 368
- Issue
- 9
- Pages
- 795-805
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2134592673
- Cited by
- 874
- References
- 37
- FWCI
- 80.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.