The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Robotic Leg Control with EMG Decoding in an Amputee with Nerve Transfers
Open accessAbstract
The clinical application of robotic technology to powered prosthetic knees and ankles is limited by the lack of a robust control strategy. We found that the use of electromyographic (EMG) signals from natively innervated and surgically reinnervated residual thigh muscles in a patient who had undergone knee amputation improved control of a robotic leg prosthesis. EMG signals were decoded with a pattern-recognition algorithm and combined with data from sensors on the prosthesis to interpret the patient's intended movements. This provided robust and intuitive control of ambulation--with seamless transitions between walking on level ground, stairs, and ramps--and of the ability to reposition the leg while the patient was seated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Targeted Muscle Reinnervation for Real-time Myoelectric Control of Multifunction Artificial Arms
Kuiken, T. A. (2009) · JAMA · doi:10.1001/jama.2009.116 · Cited by 1,089
Self-citationA Strategy for Identifying Locomotion Modes Using Surface Electromyography
Huang, H., Kuiken, T. A., & Lipschutz, R. D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2003293 · Cited by 512
Self-citationMulticlass Real-Time Intent Recognition of a Powered Lower Limb Prosthesis
Varol, H. A., Sup, F., & Goldfarb, M. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2034734 · Cited by 425
Decoding a New Neural–Machine Interface for Control of Artificial Limbs
Zhou, P., Lowery, M. M., Englehart, K. B., Huang, H., Li, G., Hargrove, L., Dewald, J. P. A., & Kuiken, T. A. (2007) · Journal of Neurophysiology · doi:10.1152/jn.00178.2007 · Cited by 215
Self-citationControl of Stair Ascent and Descent With a Powered Transfemoral Prosthesis
Lawson, B. E., Varol, H. A., Huff, A., Erdemir, E., & Goldfarb, M. (2013) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2225640 · Cited by 206
Time-Varying Dynamic Bayesian Networks
Song, L., Kolar, M., & Xing, E. P. (2009) · Cited by 152
Design and control of an active electrical knee and ankle prosthesis
Sup, F. C., Varol, H. A., Mitchell, J. E., Withrow, T. J., & Goldfarb, M. T. (2008) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2008.4762811 · Cited by 139
Bellmann, M., Schmalz, T., Ludwigs, E., & Blumentritt, S. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.10.017 · Cited by 91
The Effects of Targeted Muscle Reinnervation on Neuromas in a Rabbit Rectus Abdominis Flap Model
Kim, P. S.-H., Ko, J. H., O'Shaughnessy, K. K., Kuiken, T., Pohlmeyer, E. A., & Dumanian, G. A. (2012) · The Journal Of Hand Surgery · doi:10.1016/j.jhsa.2012.04.044 · Cited by 88
Self-citationReal-Time Myoelectric Control of Knee and Ankle Motions for Transfemoral Amputees
Hargrove, L. J., Simon, A. M., Lipschutz, R. D., Finucane, S. B., & Kuiken, T. (2011) · JAMA · doi:10.1001/jama.2011.465 · Cited by 67
Self-citation
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“Themotivation for doing so is that a DBN (which is similar in concept to a hiddenMarkovmodel) uses prior sensor information that can be mixed with current information in order to estimate the likelihood of a transition between locomotive modes.”
BackgroundMethodInfluentialDavis, T. S., Wark, H. A. C., Hutchinson, D. T., Warren, D. J., O’Neill, K., Scheinblum, T., Clark, G. A., Normann, R. A., & Greger, B. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/036001 · Cited by 314
A deep-learned skin sensor decoding the epicentral human motions
Kim, K. K., Ha, I., Kim, M., Choi, J., Won, P., Jo, S., & Ko, S. H. (2020) · Nature Communications · doi:10.1038/s41467-020-16040-y · Cited by 299
Enhancing functional abilities and cognitive integration of the lower limb prosthesis
Petrini, F. M., Valle, G., Bumbasirevic, M., Barberi, F., Bortolotti, D., Cvancara, P., Hiairrassary, A., Mijovic, P., Sverrisson, A. Ö., Pedrocchi, A., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aav8939 · Cited by 265
Targeted Muscle Reinnervation for the Upper and Lower Extremity
Kuiken, T. A., Barlow, A. K., Hargrove, L. J., & Dumanian, G. A. (2017) · Techniques in Orthopaedics · doi:10.1097/bto.0000000000000194 · Cited by 143
Self-citation
Metadata
- Authors
- Hargrove, L. J., Simon, A. M., Young, A. J., Lipschutz, R. D., Finucane, S. B., Smith, D. G., & Kuiken, T. A.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2013-09-26
- Volume
- 369
- Issue
- 13
- Pages
- 1237-1242
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2106133733
- Cited by
- 253
- References
- 10
- FWCI
- 12.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robotic Leg Control with EMG Decoding in an Amputee with Nerve Transfers. https://app.cochat.ai/papers/10.1056/nejmoa1300126
- The paper
- Hargrove, L. J., Simon, A. M., Young, A. J., Lipschutz, R. D., Finucane, S. B., Smith, D. G., & Kuiken, T. A. (2013). Robotic Leg Control with EMG Decoding in an Amputee with Nerve Transfers. New England Journal of Medicine. https://doi.org/10.1056/nejmoa1300126
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.