The DOI matches its Crossref record.
Control of Stair Ascent and Descent With a Powered Transfemoral Prosthesis
Abstract
This paper presents a finite state-based control system for a powered transfemoral prosthesis that provides stair ascent and descent capability. The control system was implemented on a powered prosthesis and evaluated by a unilateral, transfemoral amputee subject. The ability of the powered prosthesis to provide stair ascent and descent capability was assessed by comparing the gait kinematics, as recorded by a motion capture system, with the kinematics provided by a passive prosthesis, in addition to those recorded from a set of healthy subjects. The results indicate that the powered prosthesis provides gait kinematics that are considerably more representative of healthy gait, relative to the passive prosthesis, for both stair ascent and descent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 14
- 10.1109/TBME.2011.2160173 · DOI
- 10.1109/TBME.2009.2034734 · DOI · Paper page
- koganezawa, 1987, Multifunctional above-knee prosthesis for stairs' walking, Prosthet Orthot Int, 11, 139, 10.3109/03093648709078198 · DOI
- 10.1016/j.gaitpost.2006.04.008 · DOI
- 10.1109/7333.928571 · DOI · Paper page
- 10.1016/j.neunet.2008.03.006 · DOI · Paper page
- 10.1016/0021-9290(88)90282-5 · DOI · Paper page
- 10.1109/BIOROB.2008.4762887 · DOI · Paper page
- 10.1109/TRO.2008.2008747 · DOI · Paper page
- 10.1109/TMECH.2009.2032688 · DOI · Paper page
- 10.1115/1.4001139 · doi:10.1115/1.4001139
- 10.1249/mss.0b013e31814538c8 · doi:10.1249/mss.0b013e31814538c8
- 10.1109/TNSRE.2010.2087360 · DOI · Paper page
- 10.1016/S0966-6362(01)00162-X · DOI · Paper page
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“include standing on inclined surfaces [108], running [137], and stair ascent [138].”
Toward higher-performance bionic limbs for wider clinical use
Farina, D., Vujaklija, I., Brånemark, R., Bull, A. M. J., Dietl, H., Graimann, B., Hargrove, L. J., Hoffmann, K.-P., Huang, H., Ingvarsson, T., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00732-x · Cited by 263
Active lower limb prosthetics: a systematic review of design issues and solutions
Windrich, M., Grimmer, M., Christ, O., Rinderknecht, S., & Beckerle, P. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0284-9 · Cited by 272
Robotic Leg Control with EMG Decoding in an Amputee with Nerve Transfers
Hargrove, L. J., Simon, A. M., Young, A. J., Lipschutz, R. D., Finucane, S. B., Smith, D. G., & Kuiken, T. A. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1300126 · Cited by 253
A review of current state-of-the-art control methods for lower-limb powered prostheses
Gehlhar, R., Tucker, M., Young, A. J., & Ames, A. D. (2023) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2023.03.003 · Cited by 131
Metadata
- Authors
- Lawson, B. E., Varol, H. A., Huff, A., Erdemir, E., & Goldfarb, M.
- Venue
- IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Published
- 2013-05
- Volume
- 21
- Issue
- 3
- Pages
- 466-473
- ISSN
- 1534-4320 (ISSN-L)
- 1558-0210
- OpenAlex
- W2017249007
- Cited by
- 206
- References
- 0
- FWCI
- 7.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Control of Stair Ascent and Descent With a Powered Transfemoral Prosthesis. https://app.cochat.ai/papers/10.1109/tnsre.2012.2225640
- The paper
- Lawson, B. E., Varol, H. A., Huff, A., Erdemir, E., & Goldfarb, M. (2013). Control of Stair Ascent and Descent With a Powered Transfemoral Prosthesis. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2012.2225640
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.