Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 206

The DOI matches its Crossref record.

Control of Stair Ascent and Descent With a Powered Transfemoral Prosthesis

Lawson, Brian Edward, Varol, Huseyin Atakan, Huff, Amanda, Erdemir, Erdem, Goldfarb, Michael·2013·IEEE Transactions on Neural Systems and Rehabilitation Engineering

Abstract

This paper presents a finite state-based control system for a powered transfemoral prosthesis that provides stair ascent and descent capability. The control system was implemented on a powered prosthesis and evaluated by a unilateral, transfemoral amputee subject. The ability of the powered prosthesis to provide stair ascent and descent capability was assessed by comparing the gait kinematics, as recorded by a motion capture system, with the kinematics provided by a passive prosthesis, in addition to those recorded from a set of healthy subjects. The results indicate that the powered prosthesis provides gait kinematics that are considerably more representative of healthy gait, relative to the passive prosthesis, for both stair ascent and descent.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tnsre.2012.2225640

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 14

  1. 10.1109/TBME.2011.2160173 · DOI
  2. 10.1109/TBME.2009.2034734 · DOI · Paper page
  3. koganezawa, 1987, Multifunctional above-knee prosthesis for stairs' walking, Prosthet Orthot Int, 11, 139, 10.3109/03093648709078198 · DOI
  4. 10.1016/j.gaitpost.2006.04.008 · DOI
  5. 10.1109/7333.928571 · DOI · Paper page
  6. 10.1016/j.neunet.2008.03.006 · DOI · Paper page
  7. 10.1016/0021-9290(88)90282-5 · DOI · Paper page
  8. 10.1109/BIOROB.2008.4762887 · DOI · Paper page
  9. 10.1109/TRO.2008.2008747 · DOI · Paper page
  10. 10.1109/TMECH.2009.2032688 · DOI · Paper page
  11. 10.1115/1.4001139 · doi:10.1115/1.4001139
  12. 10.1249/mss.0b013e31814538c8 · doi:10.1249/mss.0b013e31814538c8
  13. 10.1109/TNSRE.2010.2087360 · DOI · Paper page
  14. 10.1016/S0966-6362(01)00162-X · DOI · Paper page

Cited by

See all 206

Metadata

Authors
Lawson, B. E., Varol, H. A., Huff, A., Erdemir, E., & Goldfarb, M.
Venue
IEEE Transactions on Neural Systems and Rehabilitation Engineering
Published
2013-05
Volume
21
Issue
3
Pages
466-473
ISSN
  • 1534-4320 (ISSN-L)
  • 1558-0210
OpenAlex
W2017249007
Cited by
206
References
0
FWCI
7.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Control of Stair Ascent and Descent With a Powered Transfemoral Prosthesis. https://app.cochat.ai/papers/10.1109/tnsre.2012.2225640
The paper
Lawson, B. E., Varol, H. A., Huff, A., Erdemir, E., & Goldfarb, M. (2013). Control of Stair Ascent and Descent With a Powered Transfemoral Prosthesis. IEEE Transactions on Neural Systems and Rehabilitation Engineering. https://doi.org/10.1109/tnsre.2012.2225640

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.