The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Five-Year Outcomes after Off-Pump or On-Pump Coronary-Artery Bypass Grafting
Open accessAbstract
BACKGROUND: We previously reported that there was no significant difference at 30 days or at 1 year in the rate of the composite outcome of death, stroke, myocardial infarction, or renal failure between patients who underwent coronary-artery bypass grafting (CABG) performed with a beating-heart technique (off-pump) and those who underwent CABG performed with cardiopulmonary bypass (on-pump). We now report the results at 5 years (the end of the trial). METHODS: A total of 4752 patients (from 19 countries) who had coronary artery disease were randomly assigned to undergo off-pump or on-pump CABG. For this report, we analyzed a composite outcome of death, stroke, myocardial infarction, renal failure, or repeat coronary revascularization (either CABG or percutaneous coronary intervention). The mean follow-up period was 4.8 years. RESULTS: There were no significant differences between the off-pump group and the on-pump group in the rate of the composite outcome (23.1% and 23.6%, respectively; hazard ratio with off-pump CABG, 0.98; 95% confidence interval [CI], 0.87 to 1.10; P=0.72) or in the rates of the components of the outcome, including repeat coronary revascularization, which was performed in 2.8% of the patients in the off-pump group and in 2.3% of the patients in the on-pump group (hazard ratio, 1.21; 95% CI, 0.85 to 1.73; P=0.29). The secondary outcome for the overall period of the trial - the mean cost in U.S. dollars per patient - also did not differ significantly between the off-pump group and the on-pump group ($15,107 and $14,992, respectively; between-group difference, $115; 95% CI, -$697 to $927). There were no significant between-group differences in quality-of-life measures. CONCLUSIONS: In our trial, the rate of the composite outcome of death, stroke, myocardial infarction, renal failure, or repeat revascularization at 5 years of follow-up was similar among patients who underwent off-pump CABG and those who underwent on-pump CABG. (Funded by the Canadian Institutes of Health Research; CORONARY ClinicalTrials.gov number, NCT00463294 .).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yusuf, S., Zucker, D., Passamani, E., Peduzzi, P., Takaro, T., Fisher, L. D., Kennedy, J. W., Davis, K., Killip, T., Norris, R., et al. (1994) · The Lancet · doi:10.1016/s0140-6736(94)91963-1 · Cited by 2,134
Self-citationStrategies for Multivessel Revascularization in Patients with Diabetes
Farkouh, M. E., Domanski, M., Sleeper, L. A., Siami, F. S., Dangas, G., Mack, M., Yang, M., Cohen, D. J., Rosenberg, Y., Solomon, S. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1211585 · Cited by 1,922
Cognitive Trajectories after Postoperative Delirium
Saczynski, J. S., Marcantonio, E. R., Quach, L., Fong, T. G., Gross, A., Inouye, S. K., & Jones, R. N. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1112923 · Cited by 1,188
On-Pump versus Off-Pump Coronary-Artery Bypass Surgery
Shroyer, A. L., Grover, F. L., Hattler, B., Collins, J. F., McDonald, G. O., Kozora, E., Lucke, J. C., Baltz, J. H., & Novitzky, D. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0902905 · Cited by 1,148
Off-Pump or On-Pump Coronary-Artery Bypass Grafting at 30 Days
Lamy, A., Devereaux, P. J., Prabhakaran, D., Taggart, D. P., Hu, S., Paolasso, E., Straka, Z., Piegas, L. S., Akar, A. R., Jain, A. R., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200388 · Cited by 707
Self-citationPuskas, J. D., Williams, W. H., Mahoney, E. M., Huber, P. R., Block, P. C., Duke, P. G., Staples, J. R., Glas, K. E., Marshall, J. J., Leimbach, M. E., et al. (2004) · JAMA · doi:10.1001/jama.291.15.1841 · Cited by 565
Off-Pump versus On-Pump Coronary-Artery Bypass Grafting in Elderly Patients
Diegeler, A., Börgermann, J., Kappert, U., Breuer, M., Böning, A., Ursulescu, A., Rastan, A., Holzhey, D., Treede, H., Rieß, F.-C., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1211666 · Cited by 519
Effects of Off-Pump and On-Pump Coronary-Artery Bypass Grafting at 1 Year
Lamy, A., Devereaux, P. J., Prabhakaran, D., Taggart, D. P., Hu, S., Paolasso, E., Straka, Z., Piegas, L. S., Akar, A. R., Jain, A. R., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1301228 · Cited by 438
Self-citationNeed for expertise based randomised controlled trials
Devereaux, P. J., Bhandari, M., Clarke, M., Montori, V. M., Cook, D. J., Yusuf, S., Sackett, D. L., Cinà, C. S., Walter, S. D., Haynes, B., et al. (2005) · BMJ · doi:10.1136/bmj.330.7482.88 · Cited by 427
Self-citationA Comparison of On-Pump and Off-Pump Coronary Bypass Surgery in Low-Risk Patients
Nathoe, H. M., van Dijk, D., Jansen, E. W. L., Suyker, W. J. L., Diephuis, J. C., van Boven, W.-J., de la Rivière, A. B., Borst, C., Kalkman, C. J., Grobbee, D. E., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa021775 · Cited by 402
Head, S. J., Davierwala, P. M., Serruys, P. W., Redwood, S. R., Colombo, A., Mack, M. J., Morice, M.-C., Holmes, D. R., Feldman, T. E., Stahle, E., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu213 · Cited by 361
van Dijk, D., Spoor, M., Hijman, R., Nathoe, H. M., Borst, C., Jansen, E. W. L., Grobbee, D. E., de Jaegere, P. P. T., Kalkman, C. J., & Octopus Study Group, F. T. (2007) · JAMA · doi:10.1001/jama.297.7.701 · Cited by 294
Hannan, E. L., Wu, C., Smith, C. R., Higgins, R. S. D., Carlson, R. E., Culliford, A. T., Gold, J. P., & Jones, R. H. (2007) · Circulation · doi:10.1161/circulationaha.106.675595 · Cited by 294
Sellke, F. W., DiMaio, J. M., Caplan, L. R., Ferguson, T. B., Gardner, T. J., Hiratzka, L. F., Isselbacher, E. M., Lytle, B. W., Mack, M. J., Murkin, J. M., et al. (2005) · Circulation · doi:10.1161/circulationaha.105.165030 · Cited by 262
Off-pump versus on-pump coronary surgery: final results from a prospective randomized study Prague-4
Straka, Z., Widimsky, P., Jirasek, K., Stros, P., Votava, J., Vanek, T., Brucek, P., Kolesar, M., & Spacek, R. (2004) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2003.08.039 · Cited by 191
Self-citationHoulind, K., Kjeldsen, B. J., Madsen, S. N., Rasmussen, B. S., Holme, S. J., Nielsen, P. H., & Mortensen, P. E. (2012) · Circulation · doi:10.1161/circulationaha.111.052571 · Cited by 160
Puskas, J. D., Williams, W. H., O'Donnell, R., Patterson, R. E., Sigman, S. R., Smith, A. S., Baio, K. T., Kilgo, P. D., & Guyton, R. A. (2011) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2010.12.043 · Cited by 158
Hueb, W. A., Lopes, N. H. M., Pereira, A. C., Hueb, A. C., Soares, P. R., Favarato, D., Vieira, R. D., Lima, E. G., Garzillo, C. L., Paulitsch, F. D. S., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.924258 · Cited by 130
Long-Term Survival Following Coronary Artery Bypass Grafting
Kim, J. B., Yun, S., Lim, J. W., Hwang, S. K., Jung, S., Song, H., Chung, C. H., Lee, J. W., & Choo, S. J. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.02.584 · Cited by 72
Lamy, A. L., Devereaux, P. J., Prabhakaran, D., Hu, S., Piegas, L. S., Straka, Z., Paolasso, E., Taggart, D. P., Lanas, F. T., Akar, A. R., et al. (2011) · American Heart Journal · doi:10.1016/j.ahj.2011.10.007 · Cited by 45
Self-citation
Cited by
2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.09.006 · Cited by 1,558
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Circulation · doi:10.1161/cir.0000000000001038 · Cited by 829
Mechanisms, Consequences, and Prevention of Coronary Graft Failure
Gaudino, M., Antoniades, C., Benedetto, U., Deb, S., Di Franco, A., Di Giammarco, G., Fremes, S., Glineur, D., Grau, J., He, G.-W., et al. (2017) · Circulation · doi:10.1161/circulationaha.117.027597 · Cited by 355
Self-citationFive-Year Outcomes after On-Pump and Off-Pump Coronary-Artery Bypass
Shroyer, A. L., Hattler, B., Wagner, T. H., Collins, J. F., Baltz, J. H., Quin, J. A., Almassi, G. H., Kozora, E., Bakaeen, F., Cleveland, J. C., et al. (2017) · New England Journal of Medicine · doi:10.1056/nejmoa1614341 · Cited by 310
Saphenous vein grafts in contemporary coronary artery bypass graft surgery
Caliskan, E., de Souza, D. R., Böning, A., Liakopoulos, O. J., Choi, Y.-H., Pepper, J., Gibson, C. M., Perrault, L. P., Wolf, R. K., Kim, K.-B., et al. (2020) · Nature Reviews Cardiology · doi:10.1038/s41569-019-0249-3 · Cited by 265
Metadata
- Authors
- Lamy, A., Devereaux, P. J., Prabhakaran, D., Taggart, D. P., Hu, S., Straka, Z., Piegas, L. S., Avezum, A., Akar, A. R., Lanas Zanetti, F., Jain, A. R., Noiseux, N., Padmanabhan, C., Bahamondes, J.-C., Novick, R. J., Tao, L., Olavegogeascoechea, P. A., Airan, B., Sulling, T.-A., Whitlock, R. P., Ou, Y., Gao, P., Pettit, S., & Yusuf, S.
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2016-12-15
- Volume
- 375
- Issue
- 24
- Pages
- 2359-2368
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2533292853
- Cited by
- 432
- References
- 20
- FWCI
- 52.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.