The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation
Open accessAbstract
BACKGROUND: Current guidelines recommend pulmonary-vein isolation by means of catheter ablation as treatment for drug-refractory paroxysmal atrial fibrillation. Radiofrequency ablation is the most common method, and cryoballoon ablation is the second most frequently used technology. METHODS: We conducted a multicenter, randomized trial to determine whether cryoballoon ablation was noninferior to radiofrequency ablation in symptomatic patients with drug-refractory paroxysmal atrial fibrillation. The primary efficacy end point in a time-to-event analysis was the first documented clinical failure (recurrence of atrial fibrillation, occurrence of atrial flutter or atrial tachycardia, use of antiarrhythmic drugs, or repeat ablation) following a 90-day period after the index ablation. The noninferiority margin was prespecified as a hazard ratio of 1.43. The primary safety end point was a composite of death, cerebrovascular events, or serious treatment-related adverse events. RESULTS: A total of 762 patients underwent randomization (378 assigned to cryoballoon ablation and 384 assigned to radiofrequency ablation). The mean duration of follow-up was 1.5 years. The primary efficacy end point occurred in 138 patients in the cryoballoon group and in 143 in the radiofrequency group (1-year Kaplan-Meier event rate estimates, 34.6% and 35.9%, respectively; hazard ratio, 0.96; 95% confidence interval [CI], 0.76 to 1.22; P<0.001 for noninferiority). The primary safety end point occurred in 40 patients in the cryoballoon group and in 51 patients in the radiofrequency group (1-year Kaplan-Meier event rate estimates, 10.2% and 12.8%, respectively; hazard ratio, 0.78; 95% CI, 0.52 to 1.18; P=0.24). CONCLUSIONS: In this randomized trial, cryoballoon ablation was noninferior to radiofrequency ablation with respect to efficacy for the treatment of patients with drug-refractory paroxysmal atrial fibrillation, and there was no significant difference between the two methods with regard to overall safety. (Funded by Medtronic; FIRE AND ICE ClinicalTrials.gov number, NCT01490814.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“achievable by point-by-point radiofrequency ablation, linear lesions encircling the pulmonary veins, or cryoballoon ablation, with similar outcomes.[732][733][734]”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [734]
In the citing paper
“It also seems even less common after cryoballoon ablation, 734”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [734]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins.
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Mouroux, A. L., Métayer, P. L., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 8,040
Approaches to catheter ablation for persistent atrial fibrillation
Verma, A., Jiang, C.-Y., Betts, T. R., Chen, J., Deisenhofer, I., Mantovan, R., Macle, L., Morillo, C. A., Haverkamp, W., Weerasooriya, R., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1408288 · Cited by 2,339
Self-citationCalkins, H. G., Kück, K., Cappato, R., Brugada, J., Camm, A. J., Chen, S., Crijns, H. J. G. M., Damiano, R. J., Davies, D. W., Dimarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,685
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citationWilber, D. J., Pappone, C., Neuzil, P., De Paola, A., Marchlinski, F., Natale, A., Macle, L., Daoud, E. G., Calkins, H., Hall, B., et al. (2010) · JAMA · doi:10.1001/jama.2009.2029 · Cited by 1,170
Cryoballoon Ablation of Pulmonary Veins for Paroxysmal Atrial Fibrillation
Packer, D. L., Kowal, R. C., Wheelan, K. R., Irwin, J. M., Champagne, J., Guerra, P. G., Dubuc, M., Reddy, V. Y., Nelson, L., Holcomb, R. G., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.064 · Cited by 919
Paroxysmal AF Catheter Ablation With a Contact Force Sensing Catheter
Natale, A., Reddy, V. Y., Monir, G., Wilber, D. J., Lindsay, B. D., McElderry, H. T., Kantipudi, C., MANSOUR, M. C., Melby, D. P., Packer, D. L., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.072 · Cited by 476
Kautzner, J., Neužil, P., Lambert, H., Peichl, P., Petrů, J., Cihak, R. J., Skoda, J., Wichterle, D., Wißner, E., Yulzari, A., et al. (2015) · EP Europace · doi:10.1093/europace/euv057 · Cited by 374
Luik, A., Radzewitz, A., Kieser, M., Walter, M., Bramlage, P., Hörmann, P., Schmidt, K., Horn, N., Brinkmeier-Theofanopoulou, M., Kunzmann, K., et al. (2015) · Circulation · doi:10.1161/circulationaha.115.016871 · Cited by 275
Kuck, K.-H., Hoffmann, B. A., Ernst, S., Wegscheider, K., Treszl, A., Metzner, A., Eckardt, L., Lewalter, T., Breithardt, G., & Willems, S. (2016) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.003337 · Cited by 261
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Items 901–1,000 of 1,000
Catheter ablation for atrial fibrillation: Results from a European survey
Sousa, P. A., Heeger, C.-H. H., Barra, S., Luther, V., Steinfurt, J., Fernández‐Armenta, J., & Silberbauer, J. (2025) · Heart Rhythm · doi:10.1016/j.hrthm.2025.05.028 · Cited by 6
Baykaner, T., Duff, S., Hasegawa, J. T., Mafilios, M. S., & Turakhia, M. P. (2018) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13449 · Cited by 6
Prochnau, D., von Knorre, K., Figulla, H., Schulze, P. C., & Surber, R. (2018) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2018.09.009 · Cited by 6
Mann, I., Sasikaran, T., Sandler, B. C., Babalis, D. S., Johnson, N. A., Falaschetti, E., Copley, A., Tayebjee, M. H., TODD, D. M., Shepherd, E., et al. (2019) · American Heart Journal · doi:10.1016/j.ahj.2019.04.015 · Cited by 6
The Coagulation and Atrial Fibrillation Ablation Cascades
Asirvatham, S. J., & van Zyl, M. (2019) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2019.09.009 · Cited by 6
Catheter Ablation in the Treatment of Atrial Fibrillation
HESSELSON, A. B. (2020) · International Journal of Angiology · doi:10.1055/s-0040-1708476 · Cited by 6
Zhu, S., Zheng, M., Yan, R., Tan, Z., Zhao, H., Zhang, J., & Peng, J. (2020) · PubMed Central · doi:10.12122/j.issn.1673-4254.2020.10.06 · Cited by 6
Parker, A. M., Vilaro, J. R., Ahmed, M. M., & Aranda, J. M. (2020) · Cardiovascular Innovations and Applications · doi:10.15212/cvia.2019.0595 · Cited by 6
Chieng, D., Finch, S. J., Sugumar, H., Taylor, A. J., Reid, C. M., Kalman, J. M., & Kistler, P. M. (2020) · EP Europace · doi:10.1093/europace/euaa308 · Cited by 6
Clinical outcomes following rhythm control for atrial fibrillation: is early better?
Kotalczyk, A., Ding, W. Y., Gupta, D., Wright, D. J., & Lip, G. Y. H. (2021) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2021.1902307 · Cited by 6
Prevalence of gastric hypomotility after additional cryoballoon ablation of the left atrial roof
Shigeta, T., Yamauchi, Y., Oda, A., Tachibana, S., Hirao, T., Nakamura, R. A., Yoshida, H., Okishige, K., Goya, M., & Sasano, T. (2021) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14387 · Cited by 6
Chen, D., Xia, Y., Lin, Y., Li, X., Wang, C., Chen, Y., Fang, P., & Liu, J. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.836392 · Cited by 6
Wörmann, J., Lüker, J., van den Bruck, J., Filipovic, K., Erlhöfer, S., Scheurlen, C., Dittrich, S., Schipper, J., Steven, D., & Sultan, A. (2023) · Clinical Research in Cardiology · doi:10.1007/s00392-023-02188-2 · Cited by 6
Park, C. S., Kim, H., Lee, S., Lee, J. H., Cho, Y., Choi, E., Oh, I., & Oh, S. (2023) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-023-01555-3 · Cited by 6
Schiavone, M., Gasperetti, A., Martignani, C., Montemerlo, E., Ciconte, G., Ziacchi, M., Arosio, R., Piazzi, E., Spadotto, A., Ruggiero, D., et al. (2023) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16087 · Cited by 6
Kwon, C. H., Choi, J., Oh, I., Lee, S., Kim, J. Y., Lee, S. H., Park, J., Kim, K., Yang, P., Kim, J., et al. (2023) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16122 · Cited by 6
Ikenouchi, T., Miyazaki, S., Nitta, J., Sekiguchi, Y., Kobori, A., Nakamura, K., Inamura, Y., Murakami, M., Sagawa, Y., Sasaki, Y., et al. (2023) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-023-01718-2 · Cited by 6
Sargent, S. R., Mladenovic, J., Liaw, J. J. T., Siller, J., Russell, P. L., Tung, M., & Holland, D. J. (2024) · Heart Lung and Circulation · doi:10.1016/j.hlc.2024.02.009 · Cited by 6
Velthuis, B. O., Molenaar, M. M. D., Dorman, H. G. R., Stevenhagen, J., SCHOLTEN, M. F., van der Palen, J. A. M., & van Opstal, J. M. (2017) · Netherlands Heart Journal · doi:10.1007/s12471-017-0962-7 · Cited by 6
Advances in Clinical Cardiology 2016: A Summary of the Key Clinical Trials
Gray, A. P., McQuillan, C., & Menown, I. B. A. (2017) · Advances in Therapy · doi:10.1007/s12325-017-0560-5 · Cited by 6
Curnis, A., Salghetti, F., Cerini, M., Vassanelli, F., Inama, L., Villa, C., Giacopelli, D., Raweh, A., & Bontempi, L. (2017) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000542 · Cited by 6
Atrial Fibrillation Catheter Ablation: Overcoming Complications and Improving Success
Mathew, S. T., & Po, S. S. (2017) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2017.081004 · Cited by 6
Wei, H., Guo, X., Zhou, G., Sun, Q., Liu, X., Luo, B., Yang, J., Zhang, S., & Ma, J. (2019) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-019-00507-0 · Cited by 6
New mapping tools to assess lesion in atrial fibrillation
García‐Bolao, I., Ramos, P., Ballesteros, G., & Vives, E. (2019) · EP Europace · doi:10.1093/europace/euz110 · Cited by 6
Prevention of left atrium esophagus fistula: Appraisal of existing technologies and strategies
Jiang, R., Zei, P. C., & Jiang, C. (2020) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13939 · Cited by 6
Santoro, F., Brunetti, N. D., Rillig, A., Reißmann, B., Lemeš, C., Maurer, T., Fink, T., Hashiguchi, N., Leopizzi, A., Mallardi, A., et al. (2020) · Journal of Thrombosis and Thrombolysis · doi:10.1007/s11239-020-02148-x · Cited by 6
Self-citationVelagić, V., Prepolec, I., Pašara, V., Puljević, M., Puljević, D., Planinc, I., Samardžić, J., & Miličić, D. (2020) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2020.09.003 · Cited by 6
Sun, X., Qi, P., Yang, B., Li, Z., Bie, Z., & Li, X. (2020) · International Journal of Cardiology · doi:10.1016/j.ijcard.2020.10.030 · Cited by 6
Wieczorek, M., & Hoeltgen, R. (2020) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14102 · Cited by 6
Nava, A., Mansilla, A. G., González‐Torrecilla, E., Ávila, P., Datino, T., Bermejo, J., Arenal, Á., Fernández‐Avilés, F., & Atienza, F. (2021) · Biology · doi:10.3390/biology10090838 · Cited by 6
The future of long‐term monitoring after catheter and surgical ablation for atrial fibrillation
Baman, J. R., & PASSMAN, R. S. (2022) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15375 · Cited by 7
Single ring isolation for atrial fibrillation ablation: Impact of the learning curve
Thiyagarajah, A., Mahajan, R., Iwai, S., Gupta, A. K., Linz, D., Chim, I., Emami, M., Kadhim, K., O’Shea, C., Middeldorp, M. E., et al. (2022) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15387 · Cited by 6
Kanaoka, K., Nishida, T., Nishioka, Y., Myojin, T., Kubo, S., Soeda, T., Okada, K., Noda, T., Iwanaga, Y., Miyamoto, Y., et al. (2022) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15495 · Cited by 6
Qiao, Y., Zhao, Z., Cai, X., Guo, Y., Fu, M., Liu, K., Guo, J., Guo, T., & Niu, G. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.922910 · Cited by 6
Honarbakhsh, S., O’Brien, B., & SCHILLING, R. J. (2017) · Journal of Atrial Fibrillation · doi:10.4022/jafib.1628 · Cited by 6
Fujino, T., Yuzawa, H., Kinoshita, T., Shinohara, M., Okishige, K., & Ikeda, T. (2019) · Journal of Cardiology Cases · doi:10.1016/j.jccase.2019.04.005 · Cited by 6
Houmsse, M., Daoud, E. G., Joseph, M., Weiss, R., & Essandoh, M. K. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14529 · Cited by 6
Wagner, L., Darche, F. F., Thomas, D., Lugenbiel, P., Xynogalos, P., Seide, S., Scholz, E., Katus, H. A., & Schweizer, P. A. (2020) · Clinical Research in Cardiology · doi:10.1007/s00392-020-01659-0 · Cited by 6
Kukendrarajah, K., Παπαγεωργίου, Ν., Jewell, P. D., Hunter, R. J., Ang, R., SCHILLING, R. J., & Providencia, R. A. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14598 · Cited by 6
Alken, F., Chen, S., Masjedi, M., Pürerfellner, H., Maury, P., Martin, C., Sacher, F., Jaı̈s, P., & Meyer, C. G. (2020) · Future Cardiology · doi:10.2217/fca-2020-0032 · Cited by 6
Zhou, X., Dai, J. M., Xu, X., Lian, M., Lou, Y., Lv, Z., Wang, Z., & Mao, W. (2020) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-020-00878-9 · Cited by 6
Sharma, P. S., Padala, S. K., THOMPSON, J. J., Gunda, S., Koneru, J. N., & Ellenbogen, K. A. (2016) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13082 · Cited by 6
Circulatory Dynamics During Pulmonary Vein Isolation Using the Second‐Generation Cryoballoon
Kajiyama, T., Miyazaki, S., Watanabe, T., Yamao, K., Kusa, S., Igarashi, M., Nakamura, H., Hachiya, H., & Iesaka, Y. (2017) · Journal of the American Heart Association · doi:10.1161/jaha.117.006559 · Cited by 6
Calkins, H. G. (2019) · Circulation · doi:10.1161/circulationaha.119.043155 · Cited by 6
Comparative Studies of Different Ablation Techniques for Atrial Fibrillation
Keževičiūtė, M., Marinskis, G., Sudavičienė, D., Barysienė, J., Bileišienė, N., Radauskaitė, G., Aidietis, A., & Račkauskas, G. (2025) · Reviews in Cardiovascular Medicine · doi:10.31083/rcm33490 · Cited by 6
Arrhythmia-Induced Cardiomyopathy in Atrial Fibrillation: Pathogenesis, Diagnosis, and Treatment
Karakasis, P., Theofilis, P., Vlachakis, P. K., Apostolos, A., Ktenopoulos, N., Grigoriou, K., Patoulias, D., Antoniadis, A. P., & Fragakis, N. (2025) · Life · doi:10.3390/life15111675 · Cited by 8
Kılıç, M. E., Arayıcı, M. E., Yılancıoglu, R. Y., Turan, O. E., & Özcan, E. E. (2026) · Heart Rhythm · doi:10.1016/j.hrthm.2026.01.026 · Cited by 5
Sohns, C., Fink, T., Bergau, L., BRAUN, M. U., Hamriti, M. E., Sciacca, V., Guckel, D., Khalaph, M., Imnadze, G., & Sommer, P. (2023) · Cardiology Journal · doi:10.5603/cj.a2022.0122 · Cited by 5
How the new technologies and tools will change the electrophysiology of the future
Tondo, C. (2023) · European Heart Journal Supplements · doi:10.1093/eurheartjsupp/suad024 · Cited by 5
Self-citationShigeta, T., Okishige, K., Murata, K., Oda, A., Arai, H., Sagawa, Y., Kurabayashi, M., Goya, M., Sasano, T., & Yamauchi, Y. (2023) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16082 · Cited by 5
Park, H., Park, J., Kim, D., Yu, H. T., Kim, T., Uhm, J., Joung, B., Lee, M., Hwang, C., & Pak, H. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1238363 · Cited by 5
Zylla, M. M., Starrach, L., Rahm, A., Thomas, D., Frey, N., & Lugenbiel, P. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1208250 · Cited by 5
Zhao, Y., Yuan, X., Xie, Y., Yin, X., Liu, Y., Sun, Y., Gong, Y., Liu, J., & Chen, F. (2024) · Journal of the American Heart Association · doi:10.1161/jaha.123.031928 · Cited by 5
Maurhofer, J., Kueffer, T., Knecht, S., Thalmann, G., Badertscher, P., Kozhuharov, N., Krisai, P., Jufer, C., Iqbal, S. U. R., Heg, D., et al. (2024) · Heart Rhythm O2 · doi:10.1016/j.hroo.2024.05.008 · Cited by 5
Schiavone, M., Bianchi, S., Malacrida, M., Fassini, G. M., Ricciolino, R., Pecora, D., Pelargonio, G., Iacopino, S., Ducceschi, V., Maggio, R., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.08.040 · Cited by 5
Self-citationWan, Y., Zeng, S., Liu, F., Gao, X., Li, W., Liu, K., He, J., Ji, J., & Luo, J. (2024) · Cardiology in Review · doi:10.1097/crd.0000000000000808 · Cited by 5
Global Research Progress on Radiofrequency Ablation in Cardiology
Elendu, C., Ogwu, N. P., Okatta, A. U., Omeludike, E., Ogelle, E. C., Obidigbo, B. T., Joseph, M. C., Osamuyi, E. I., Ogidan, A. O., Jingwa, K. A., et al. (2024) · Annals of Medicine and Surgery · doi:10.1097/ms9.0000000000002858 · Cited by 5
Yang, F., & Wu, Y. Y. (2025) · The Journal of Cardiovascular Nursing · doi:10.1097/jcn.0000000000001219 · Cited by 5
Cho, M. S., Lee, J. H., Oh, I.-Y., Lee, J.-B., Kim, M., Choi, K., Cho, Y., Nam, G., Nam, G.-B., Cho, Y., et al. (2025) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2025.08.003 · Cited by 5
ARENA – Projekt Vorhofflimmern in der Rhein-Neckar-Region
Baumann, S., Grau, A., Senges, J., Schneider, S., Alonso, Á., Katus, H. A., Thomas, D., Waldecker, B., Haass, M., Zahn, R., et al. (2019) · Herz · doi:10.1007/s00059-018-4772-5 · Cited by 5
Chen, J., Wu, H. I., & Chang, K. (2020) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-020-00892-x · Cited by 5
Yahsaly, L., Siebermair, J., & Wakili, R. (2022) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-022-00843-1 · Cited by 5
Krause, U., Müller, M. J., Schneider, H. E., & Paul, T. (2022) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-022-01213-0 · Cited by 5
Wei, Y., Chen, L., Cao, J., Liu, S., Ling, T., Huang, X., Zhou, G., Lin, C., Xie, Y., Bao, Y., et al. (2022) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14556 · Cited by 5
Impact of BMI and Type of Ablation Procedure on Atrial Fibrillation Recurrence in Japanese Patients
Takami, A., Miake, J., Kato, M., Ogura, K., Okamura, A., Tomomori, T., Tsujimoto, D., Kawatani, S., Kato, M., & Yamamoto, K. (2022) · Journal of Asian Pacific Society of Cardiology · doi:10.15420/japsc.2021.27 · Cited by 5
Tsiachris, D., Doundoulakis, I., Antoniou, C. K., Pagkalidou, E., Zafeiropoulos, S., Kordalis, A., Gatzoulis, K. A., Chierchia, G., de Asmundis, C., Tsioufis, K. P., et al. (2022) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15697 · Cited by 5
Tokuda, M., Yamashita, S., Sato, H., Oseto, H., Yokoyama, M., Tokutake, K., Yokoyama, K., Kato, M., Narui, R., Tanigawa, S., et al. (2022) · Heart and Vessels · doi:10.1007/s00380-022-02179-9 · Cited by 5
Hori, Y., Nakahara, S., Aoki, H., Sato, H., Fukuda, R., Hua, Z., Koshikawa, Y., Mizutani, Y., Nakamura, H., Hisauchi, I., et al. (2022) · Heart and Vessels · doi:10.1007/s00380-022-02210-z · Cited by 5
Mao, Y., Ai, L.-J., Cai, Y.-H., Huang, Q., Yu, F., Chen, J., Huang, P., & Wang, H. (2023) · Cardiology · doi:10.1159/000528758 · Cited by 5
Oka, S., Yamagata, K., Nishii, T., Tonegawa‐Kuji, R., Shimamoto, K., Inoue, Y. Y., Miyamoto, K., Nagase, S., Aiba, T., & KUSANO, K. F. (2023) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15825 · Cited by 5
Elias, A., Khoury, Y., Shehadeh, F., Ron, G., Boulos, M., Nashashibi, J., Zukermann, R., Elias, M. S., Gepstein, L., & Suleiman, M. A. (2023) · Research and Practice in Thrombosis and Haemostasis · doi:10.1016/j.rpth.2023.100127 · Cited by 5
Potenza, M., Pisano, C., Coppa, P., Bovesecchi, G., Corasaniti, S., & Barbero, F. (2023) · International Communications in Heat and Mass Transfer · doi:10.1016/j.icheatmasstransfer.2023.106877 · Cited by 5
Pulsed field ablation of superior vena cava in paroxysmal atrial fibrillation: a case report
Tao, Y., Zhou, Y., Sun, X., Liao, W., Wang, Y., Shi, L., & Liu, X. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1211674 · Cited by 5
Hashimoto, S., Motozawa, Y., & Mano, T. (2023) · International Journal of Healthcare Management · doi:10.1080/20479700.2023.2250612 · Cited by 5
Percutaneous Neuromodulation for Atrial Fibrillation
Zuhair, M., Keene, D., Kanagaratnam, P., & Lim, P. B. (2023) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2023.09.001 · Cited by 5
Nekić, A., Prepolec, I., Pašara, V., Bogdanic, J. E., Posavec, J. P., Kardum, D., Katić, Z., Štajduhar, A., Pezo-Nikolić, B., Puljević, D., et al. (2024) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-024-01752-8 · Cited by 5
Multidisciplinary management strategies for atrial fibrillation
Yue, X., Zhou, L., Li, Y., & Zhao, C. (2024) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2024.102514 · Cited by 5
Schemoul, E., Tovmassian, L., Mancini, J., Koutbi, L., Biermé, C., Deharo, J., Franceschi, F., & Maille, B. (2024) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2024.1361761 · Cited by 5
Impact of wall thickness on the tissue cooling effect of cryoballoon ablation
Masuda, M., Matsuda, Y., Uematsu, H., Nishijima, M., Okamoto, S., Ishihara, T., Nanto, K., Tsujimura, T., Hata, Y., & Mano, T. (2024) · EP Europace · doi:10.1093/europace/euae135 · Cited by 5
Mizutani, Y., Yanagisawa, S., Ichikawa, M., Nishio, K., Sakai, H., Nonokawa, D., Makino, Y., Suzuki, H., Ichimiya, H., Uchida, Y., et al. (2024) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16337 · Cited by 5
Chen, X., Zhang, X., Fang, X. M., & Feng, S. (2024) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2024.1423147 · Cited by 5
Soysal, A. U., Gulfidan, A., Raimoglou, D., Atıcı, A., Yalman, H., Kücür, M., Onder, S. E., Durmaz, E., İkitimur, B., & Yalın, K. (2024) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-024-03218-4 · Cited by 5
Insights into the prospects of nanobiomaterials in the treatment of cardiac arrhythmia
Lu, D., & Fan, X. (2024) · Journal of Nanobiotechnology · doi:10.1186/s12951-024-02805-w · Cited by 5
van Boven, N., Bhagwandien, R. E., Wijchers, S. A., Hoogendijk, M. G., Mahmoodi, B. K., & Yap, S. (2025) · Heart Rhythm O2 · doi:10.1016/j.hroo.2025.01.013 · Cited by 5
Cryoablation in persistent atrial fibrillation – a critical appraisal
Tzeis, S. E., Pastromas, S. C., Sikiotis, A., & Andrikopoulos, G. K. (2016) · Netherlands Heart Journal · doi:10.1007/s12471-016-0858-y · Cited by 5
Schirdewan, A., Herm, J., Roser, M., Landmesser, U., Endres, M., Koch, L., & Hæusler, K. G. (2017) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2017.00004 · Cited by 5
Aras, D., Topaloğlu, S., Çay, S., Özeke, Ö., Özcan, F., & Cagirci, G. (2017) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2017.02.004 · Cited by 5
Takahashi, K., Watanabe, I., Okumura, Y., Nagashima, K., Kogawa, R., Iso, K., Watanabe, R., Arai, M., Ohkubo, K., Nakai, T., et al. (2018) · Journal of Nihon University Medical Association · doi:10.4264/numa.77.1_7 · Cited by 5
“Crosstalk” technique: A comparison between two generations of cryoballoon catheter
Yang, J., Sun, Q., Guo, X., Zhou, G., Liu, X., Luo, B., Wei, H., Liang, J. J., & Ma, J. (2018) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13336 · Cited by 5
Fink, T., Tilz, R. R., Heeger, C.-H. H., Schlüter, M., Feickert, S., Rottner, L., Reißmann, B., Lemeš, C., Alessandrini, H., Maurer, T., et al. (2019) · EP Europace · doi:10.1093/europace/euz187 · Cited by 5
Self-citationAblation therapy in atrial fibrillation
Bhatti, A., Oakeshott, P., Dhinoja, M., & Grapsa, J. (2019) · BMJ · doi:10.1136/bmj.l6428 · Cited by 5
Recurrent Atrial Fibrillation After Cryoballoon Ablation
Aryana, A., Chierchia, G., & de Asmundis, C. (2020) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2020.02.002 · Cited by 5
Anwar, O., Gunawardene, M., Dickow, J., Scherschel, K., Jungen, C., Münkler, P., Eickholt, C., Willems, S., Geßler, N., & Meyer, C. G. (2020) · PLoS ONE · doi:10.1371/journal.pone.0235132 · Cited by 5
Lesion durability after antral pulmonary vein isolation using a radiofrequency hot balloon catheter
Yamasaki, H., Aonuma, K., Shinoda, Y., Komatsu, Y., Watanabe, H., Kimata, A., Aita, S., Hattori, M., Machino, T., Igarashi, M., et al. (2020) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-020-00857-0 · Cited by 5
Zeljković, I., Bulj, N., Kordić, K., Pavlović, N., Radeljić, V., Benko, I., Kordić, I. Z., Đula, K., Kos, N., Delić-Brkljačić, D., et al. (2020) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2020.100642 · Cited by 5
Lakkireddy, D. (2020) · Journal of Atrial Fibrillation · doi:10.4022/jafib.2295 · Cited by 5
Kewcharoen, J., Prasitlumkum, N., Chokesuwattanaskul, R., Yi, R., Jongnarangsin, K., Bunch, T. J., Ranjan, R., & Navaravong, L. (2021) · Journal of Arrhythmia · doi:10.1002/joa3.12641 · Cited by 4
Gitenay, E., Bars, C., Bremondy, M., Ayari, A., Maillot, N., Baptiste, F., Taormina, A., Fofana, A., Siame, S., Kalifa, J., et al. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10143170 · Cited by 5
Mao, Y., Feng, W., Huang, Q., Yu, F., Chen, J., & Wang, H. (2021) · Clinical Cardiology · doi:10.1002/clc.23695 · Cited by 5
Lycke, M., O’Neill, L., Gillis, K., Wielandts, J., de Waroux, J. L. P., Tavernier, R., Knecht, S., & Duytschaever, M. F. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10184268 · Cited by 5
Metadata
- Authors
- Kuck, K.-H., Brugada, J., Fürnkranz, A., Metzner, A., Ouyang, F., Chun, K. R. J., Elvan, A., Arentz, T., Bestehorn, K., Pocock, S. J., Albenque, J.-P., & Tondo, C.
- Affiliations
- University of Milan (IT)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2016-06-09
- Volume
- 374
- Issue
- 23
- Pages
- 2235-2245
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2333001326
- Cited by
- 1,950
- References
- 22
- Citations by year
- 2026: 127 · 2025: 182 · 2024: 184 · 2023: 194 · 2022: 201 · 2021: 218 · 2020: 223 · 2019: 196 · 2018: 176 · 2017: 179 · 2016: 67
- FWCI
- 169.93
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- LSHTM Research Online (London School of Hygiene and Tropical Medicine) (acceptedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- paroxysmal atrial fibrillation, cryoballoon ablation, radiofrequency ablation, pulmonary vein isolation, catheter ablation, non-inferiority, drug-refractory atrial fibrillation, atrial flutter, atrial tachycardia, antiarrhythmic drug use, repeat ablation, treatment-related adverse events, mortality, cerebrovascular events
- MeSH terms
- Aged, Atrial Fibrillation, Cryosurgery, Female, Follow-Up Studies, Humans, Male, Middle Aged, Postoperative Complications, Recurrence, Reoperation, Single-Blind Method, Catheter Ablation, Disease-Free Survival, Kaplan-Meier Estimate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review