The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation
Open accessAbstract
BACKGROUND: Current guidelines recommend pulmonary-vein isolation by means of catheter ablation as treatment for drug-refractory paroxysmal atrial fibrillation. Radiofrequency ablation is the most common method, and cryoballoon ablation is the second most frequently used technology. METHODS: We conducted a multicenter, randomized trial to determine whether cryoballoon ablation was noninferior to radiofrequency ablation in symptomatic patients with drug-refractory paroxysmal atrial fibrillation. The primary efficacy end point in a time-to-event analysis was the first documented clinical failure (recurrence of atrial fibrillation, occurrence of atrial flutter or atrial tachycardia, use of antiarrhythmic drugs, or repeat ablation) following a 90-day period after the index ablation. The noninferiority margin was prespecified as a hazard ratio of 1.43. The primary safety end point was a composite of death, cerebrovascular events, or serious treatment-related adverse events. RESULTS: A total of 762 patients underwent randomization (378 assigned to cryoballoon ablation and 384 assigned to radiofrequency ablation). The mean duration of follow-up was 1.5 years. The primary efficacy end point occurred in 138 patients in the cryoballoon group and in 143 in the radiofrequency group (1-year Kaplan-Meier event rate estimates, 34.6% and 35.9%, respectively; hazard ratio, 0.96; 95% confidence interval [CI], 0.76 to 1.22; P<0.001 for noninferiority). The primary safety end point occurred in 40 patients in the cryoballoon group and in 51 patients in the radiofrequency group (1-year Kaplan-Meier event rate estimates, 10.2% and 12.8%, respectively; hazard ratio, 0.78; 95% CI, 0.52 to 1.18; P=0.24). CONCLUSIONS: In this randomized trial, cryoballoon ablation was noninferior to radiofrequency ablation with respect to efficacy for the treatment of patients with drug-refractory paroxysmal atrial fibrillation, and there was no significant difference between the two methods with regard to overall safety. (Funded by Medtronic; FIRE AND ICE ClinicalTrials.gov number, NCT01490814.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“achievable by point-by-point radiofrequency ablation, linear lesions encircling the pulmonary veins, or cryoballoon ablation, with similar outcomes.[732][733][734]”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [734]
In the citing paper
“It also seems even less common after cryoballoon ablation, 734”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [734]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins.
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Mouroux, A. L., Métayer, P. L., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 8,040
Approaches to catheter ablation for persistent atrial fibrillation
Verma, A., Jiang, C.-Y., Betts, T. R., Chen, J., Deisenhofer, I., Mantovan, R., Macle, L., Morillo, C. A., Haverkamp, W., Weerasooriya, R., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1408288 · Cited by 2,339
Self-citationCalkins, H. G., Kück, K., Cappato, R., Brugada, J., Camm, A. J., Chen, S., Crijns, H. J. G. M., Damiano, R. J., Davies, D. W., Dimarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,685
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citationWilber, D. J., Pappone, C., Neuzil, P., De Paola, A., Marchlinski, F., Natale, A., Macle, L., Daoud, E. G., Calkins, H., Hall, B., et al. (2010) · JAMA · doi:10.1001/jama.2009.2029 · Cited by 1,170
Cryoballoon Ablation of Pulmonary Veins for Paroxysmal Atrial Fibrillation
Packer, D. L., Kowal, R. C., Wheelan, K. R., Irwin, J. M., Champagne, J., Guerra, P. G., Dubuc, M., Reddy, V. Y., Nelson, L., Holcomb, R. G., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.064 · Cited by 919
Paroxysmal AF Catheter Ablation With a Contact Force Sensing Catheter
Natale, A., Reddy, V. Y., Monir, G., Wilber, D. J., Lindsay, B. D., McElderry, H. T., Kantipudi, C., MANSOUR, M. C., Melby, D. P., Packer, D. L., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.072 · Cited by 476
Kautzner, J., Neužil, P., Lambert, H., Peichl, P., Petrů, J., Cihak, R. J., Skoda, J., Wichterle, D., Wißner, E., Yulzari, A., et al. (2015) · EP Europace · doi:10.1093/europace/euv057 · Cited by 374
Luik, A., Radzewitz, A., Kieser, M., Walter, M., Bramlage, P., Hörmann, P., Schmidt, K., Horn, N., Brinkmeier-Theofanopoulou, M., Kunzmann, K., et al. (2015) · Circulation · doi:10.1161/circulationaha.115.016871 · Cited by 275
Kuck, K.-H., Hoffmann, B. A., Ernst, S., Wegscheider, K., Treszl, A., Metzner, A., Eckardt, L., Lewalter, T., Breithardt, G., & Willems, S. (2016) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.003337 · Cited by 261
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Items 701–800 of 1,000
Sun, X., Jiang, L., Lin, J., Feng, T., Suo, N., Zheng, L., Liu, Z., Chen, G., Fan, X., Zhang, S., et al. (2021) · Cardiology Research and Practice · doi:10.1155/2021/8821467 · Cited by 10
Skeete, J., de Lavallaz, J. D. F., Kenigsberg, D. N., Macias, C., Winterfield, J. R., Sharma, P. S., Trohman, R. G., & Huang, H. D. (2021) · Micromachines · doi:10.3390/mi12020188 · Cited by 12
Process optimization for atrial fibrillation ablation
Boehmer, A. A., Summ, A., Vila, S., Rothe, M., Nussbaum, E., Zezyk, C., Dobre, B. C., Kaess, B. M., & Ehrlich, J. R. (2022) · EP Europace · doi:10.1093/europace/euac048 · Cited by 10
Radiofrequency Current Versus Balloon-Based Ablation for Atrial Fibrillation
Seki, R., Nagase, T., Asano, S., Fukunaga, H., Inoue, K., Sekiguchi, Y., Tanizaki, K., Nanasato, M., Umemura, J., Nitta, J., et al. (2022) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2022.05.029 · Cited by 10
Mugnai, G., Cecchini, F., Ströker, E., Paparella, G., Iacopino, S., Sieira, J. A., Greef, Y. D., Tomasi, L., Bolzan, B., Bala, G., et al. (2022) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-022-01330-w · Cited by 10
Cryoablation for Atrial Fibrillation in 2017: What Have We Learned?
Shakkottai, P., Sy, R. W., & McGuire, M. A. (2017) · Heart Lung and Circulation · doi:10.1016/j.hlc.2017.05.115 · Cited by 10
Maurer, T., & Kück, K. (2017) · Expert Review of Medical Devices · doi:10.1080/17434440.2017.1358086 · Cited by 10
Ablation of Atrial Fibrillation Drivers
Baykaner, T., Zaman, J. A. B., Wang, P. J., & Narayan, S. M. (2017) · Arrhythmia & Electrophysiology Review · doi:10.15420/2017:28:1 · Cited by 10
Liang, J. J., Mohanty, S., Fahed, J., Muser, D., Briceno, D. F., Burkhardt, J. D., Arkles, J., Supple, G. E., Frankel, D. S., Nazarian, S., et al. (2018) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2018.04.003 · Cited by 10
Jia, Q., Tian, F., Duan, W., Jia, Y., Wang, H., & Xia, Z. (2019) · Journal of College of Physicians And Surgeons Pakistan · doi:10.29271/jcpsp.2019.01.4 · Cited by 10
Mehra, N. S., Kowlgi, G. N., & Deshmukh, A. J. (2020) · Current Cardiovascular Risk Reports · doi:10.1007/s12170-020-00645-5 · Cited by 10
Ren, Z., Jia, P., Wang, S., Li, S., Li, H., Guo, R., Zhang, J., Zhang, J., Yang, H., Meng, W., et al. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14718 · Cited by 10
Maurhofer, J., Kueffer, T., Knecht, S., Madaffari, A., Badertscher, P., Seiler, J., Krisai, P., Jufer, C., Asatryan, B., Heg, D., et al. (2023) · Contemporary Clinical Trials · doi:10.1016/j.cct.2023.107341 · Cited by 9
Liu, M., Li, Q., Zhang, J., & Chen, Y. (2023) · Diagnostics · doi:10.3390/diagnostics13223403 · Cited by 10
Durability of CLOSE-Guided Pulmonary Vein Isolation in Persistent Atrial Fibrillation
Galuszka, O., Baldinger, S. H., Servatius, H., Seiler, J., Madaffari, A., Kozhuharov, N., Thalmann, G., Kueffer, T., Muehl, A., Maurhofer, J., et al. (2024) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2024.02.026 · Cited by 10
Jungen, C., Rattka, M., Bohnen, J., Mavrakis, E., Vlachopoulou, D., Dorna, S., Rudolph, I., Kohn, C., Dobrev, D., Rassaf, T., et al. (2024) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2024.101516 · Cited by 9
Ma, H., Sun, D., Luan, H., Feng, W., Zhou, Y., Wu, J., He, C., & Sun, C. (2017) · Advances in Interventional Cardiology · doi:10.5114/aic.2017.70196 · Cited by 9
Ströker, E., Kupics, K., de Asmundis, C., Mugnai, G., Regibus, V. D., Cocker, J. D., Stockman, D., Iacopino, S., Sieira-Moret, J., Brugada, P., et al. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.11.069 · Cited by 9
A saline contrast‐enhanced echocardiography‐guided approach to cryoballoon ablation
Kanda, T., Masuda, M., Kurata, N., Asai, M., Iida, O., Okamoto, S., Ishihara, T., Nanto, K., Tsujimura, T., Okuno, S., et al. (2020) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13945 · Cited by 9
How effective is cryoablation in the treatment of atrial fibrillation?
Penela, D., & Cappato, R. (2021) · European Heart Journal Supplements · doi:10.1093/eurheartj/suab089 · Cited by 9
Mitrani, L. R., Goldenthal, I. L., Leskowitz, J., Wan, E. Y., Dizon, J. M., Saluja, D. S., Creber, R. M., Turchioe, M. R., Sciacca, R. R., Garan, H., et al. (2021) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2021.11.003 · Cited by 9
Alyesh, D. M., Choe, W. C., Demo, H. N., Razminia, M., & Sundaram, S. (2022) · Current Cardiology Reports · doi:10.1007/s11886-022-01672-x · Cited by 9
Characterizing Recurrence Following Hybrid Ablation in Patients With Persistent Atrial Fibrillation
Kress, D. C., Erickson, L., Mengesha, T., Krum, D. P., & Sra, J. S. (2020) · Journal of patient-centered research and reviews · doi:10.17294/2330-0698.1744 · Cited by 8
Cardoso, R. N., Justino, G. B., Graffunder, F. P., Benevides, L., Knijnik, L., Sanchez, L. M. F., & d’Ávila, A. (2022) · Arquivos Brasileiros de Cardiologia · doi:10.36660/abc.20210477 · Cited by 18
Li, J., Yu, H., Qiao, L., Wang, B., Pang, X., He, J., Yu, Y., Yu, B., Sun, Y., Zhang, X., et al. (2022) · Journal of Translational Internal Medicine · doi:10.2478/jtim-2022-0040 · Cited by 9
Persistent Atrial Fibrillation in Elderly Patients: Limited Efficacy of Pulmonary Vein Isolation
Boehmer, A. A., Rothe, M., Zezyk, C., Soether, C. M., Dobre, B. C., Kaess, B. M., & Ehrlich, J. R. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11206070 · Cited by 9
Mizutani, Y., Yanagisawa, S., Fujiwara, G., Kasai, Y., Tajima, A., Makino, Y., Suzuki, H., Hiramatsu, T., Ichimiya, H., Uchida, Y., et al. (2022) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-022-01411-w · Cited by 9
Mahmoodi, E., Leitch, J., Davies, A. J., Leigh, L., Oldmeadow, C. J., Dwivedi, J., Boyle, A., & Jackson, N. M. (2022) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2022.12.001 · Cited by 9
Pravda, N. S., Golovchiner, G., Goldenberg, G. R., Plakht, Y., Wiessman, M. P., Tal, S., Barsheshet, A., Kadmon, E., Erez, A., Skalsky, K., et al. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm12010264 · Cited by 11
Muñoz, D. R., Castillo, A. M. D., Al-Mahdi, E. A. R., Rivera, C. L., Cárdenas, M. G., Jiménez, J. R., Bernabé, L. B., Arribas, F., & Bodes, R. S. (2023) · EP Europace · doi:10.1093/europace/euad231 · Cited by 9
Ye, W., Chen, Q., Fan, G., Zhou, X., Wang, X., Mao, W., & Li, J. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1229223 · Cited by 9
Song, W., Lv, T., Zhang, N., Li, G., Tse, G., & Liu, T. (2023) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14881 · Cited by 9
Mori, H., Hamabe, A., Kawano, D., Naganuma, T., Tahara, M., Gatate, Y., Kimura, T., Tabata, H., & Kato, R. (2023) · Journal of Arrhythmia · doi:10.1002/joa3.12981 · Cited by 9
Shigeta, T., Miyazaki, S., Isonaga, Y., Arai, H., Miwa, N., Hayashi, Y., Kakehashi, S., Inaba, O., Hachiya, H., Yamauchi, Y., et al. (2024) · Clinical Research in Cardiology · doi:10.1007/s00392-023-02365-3 · Cited by 9
Zhang, W., Wang, Y., Wang, H., Shao, Y., Dong, Q., Li, S., & Gu, Y. (2024) · The Heart Surgery Forum · doi:10.59958/hsf.7043 · Cited by 10
Krimphoff, A., Urbanek, L., Bordignon, S., Schaack, D., Tohoku, S., Chen, S., Chun, K. R. J., & Schmidt, B. (2024) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-024-01779-x · Cited by 9
Self-citationEstevez-Laborí, F., O’Brien, B., & González‐Suárez, A. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108490 · Cited by 9
Lucà, F., Pavan, D., Gulizia, M. M., Manes, M. T., Abrignani, M. G., Benedetto, F. A., Bisceglia, I., Brigido, S., Caldarola, P., Calvanese, R., et al. (2024) · European Heart Journal Supplements · doi:10.1093/eurheartjsupp/suae034 · Cited by 10
Nazer, B., Walters, T. E., Duggirala, S., & Gerstenfeld, E. P. (2017) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.116.004760 · Cited by 9
Catheter Ablation of Atrial Fibrillation: A Review of the Current Status and Future Directions
Melby, D. P. (2017) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2017.081101 · Cited by 9
Kath, N., Heinz Handels, A., & Mastmeyer, A. (2019) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-019-02033-w · Cited by 9
Current Status of Atrial Fibrillation Ablation with Balloon Strategy
Chun, K. R. J., Bordignon, S., Chen, S., Tohoku, S., Bologna, F., Urbanek, L., & Schmidt, B. (2019) · Korean Circulation Journal · doi:10.4070/kcj.2019.0226 · Cited by 9
Self-citationWei, H., Li, J., Sun, Q., Guo, X., Wang, H., Yang, J., Xie, H., Liang, J. J., Zhang, S., & Ma, J. (2019) · Journal of Cardiology · doi:10.1016/j.jjcc.2019.08.013 · Cited by 9
Hickey, K. T., Wan, E. Y., Garan, H., BIVIANO, A. B., Morrow, J., Siacca, R., Turchioe, M. R., Koleck, T. A., Caceres, B. A., Zhang, Y., et al. (2019) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2019.100902 · Cited by 10
Paroxysmal atrial fibrillation recurrence after redo procedure-ablation modality impact
Zeljković, I., Knecht, S., Spies, F., Reichlin, T., Osswald, S., Kühne, M., & Sticherling, C. (2020) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-019-00694-w · Cited by 9
Yang, Y., Wu, J., Yao, L., Liu, Y., Zhang, C., You, L., Yang, J., & Xie, R. (2020) · Bioscience Reports · doi:10.1042/bsr20193128 · Cited by 9
Prabhu, S., Ahluwalia, N., Tyebally, S. M., Dennis, A. S., Malomo, S., Abiodun, A., Tyrlis, A., Dhillon, G. S., Segan, L. A., Graham, A. J., et al. (2021) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14923 · Cited by 9
Numminen, A., Penttilä, T., Arola, O., Inkovaara, J., Oksala, N., Mäkynen, H., & Hernesniemi, J. A. (2021) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-021-01011-0 · Cited by 9
Tohoku, S., Bordignon, S., Chen, S., Zanchi, S., Bianchini, L., Trolese, L., Operhalski, F., Urbanek, L., Chun, K. R. J., & Schmidt, B. (2021) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15245 · Cited by 9
Self-citationBadoz, M., Serzian, G., Favoulet, B., Sellal, J., de Chillou, C., Hammache, N., Laurent, G., Mebazaa, A., Ecarnot, F., Bardonnet, K., et al. (2021) · Journal of the American Heart Association · doi:10.1161/jaha.121.020917 · Cited by 9
Leung, L. W. M., Akhtar, Z., Seshasai, S. R. K., & Gallagher, M. M. (2021) · EP Europace · doi:10.1093/europace/euab259 · Cited by 9
Machino, T., Aonuma, K., Komatsu, Y., Yamasaki, H., Igarashi, M., Nogami, A., & Ieda, M. (2022) · F1000Research · doi:10.12688/f1000research.75712.1 · Cited by 9
Xia, Y., Li, X., Liu, J., Yu, M., Fang, P., & Zhang, S. (2021) · PubMed Central · doi:10.11909/j.issn.1671-5411.2021.12.008 · Cited by 9
Wang, T., Fang, T., & Cheng, Z. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.853149 · Cited by 9
How to prevent, recognize and manage complications of AF ablation?
Scanavacca, M. (2017) · Revista Portuguesa de Cardiologia · doi:10.1016/j.repc.2017.09.005 · Cited by 9
Miyazaki, S., Kajiyama, T., Watanabe, T., Hada, M., Nakamura, H., Hachiya, H., Tada, H., Hirao, K., & Iesaka, Y. (2018) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13731 · Cited by 9
Sagone, A., Iacopino, S., Pieragnoli, P., Arena, G., Verlato, R., Molon, G., Rovaris, G., Curnis, A., Rauhe, W., Lunati, M., et al. (2019) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-018-0500-6 · Cited by 9
Self-citationChen, S., Kiuchi, M. G., Yin, Y., Liu, S., Schratter, A., Acou, W., Meyer, C. G., Pürerfellner, H., Chun, K. R. J., & Schmidt, B. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13858 · Cited by 10
Self-citationChikata, A., Kato, T., Usuda, K., Fujita, S., Maruyama, M., Otowa, K., Takashima, S., Murai, H., Usui, S., Furusho, H., et al. (2019) · Heart and Vessels · doi:10.1007/s00380-019-01402-4 · Cited by 9
Flexible Multi-Positional Microsensors for Cryoablation Temperature Monitoring
Zhan, Y., Hong, W., Sun, W., & Liu, J. (2019) · IEEE Electron Device Letters · doi:10.1109/led.2019.2934864 · Cited by 9
Yorgun, H., Canpolat, U., Gümeler, E., Okşul, M., Şener, Y. Z., Ateş, A. H., Akkaya, F., Karahan, S., Hazırolan, T., & Aytemir, K. (2019) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-019-00676-y · Cited by 9
Aguilar, M., Macle, L., Ditac, G., Bénali, K., Honfo, S. H., Khairy, P., Raymond-Paquin, A., Deyell, M. W., Bennett, R. G., & Andrade, J. G. (2025) · Heart Rhythm · doi:10.1016/j.hrthm.2025.05.075 · Cited by 8
Atrial Fibrillation and Heart Failure With Reduced Ejection Fraction
Boehmer, A. A., Ehrlich, J. R., & Nattel, S. (2025) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2025.09.014 · Cited by 10
Bordignon, S., Mills, M. T., Futyma, P., Sultan, A., Metzner, A., Migliore, F., Perrotta, L., Anić, A., Merino, J. L., Pürerfellner, H., et al. (2025) · EP Europace · doi:10.1093/europace/euaf254 · Cited by 9
Self-citationKettering, K., Yim, D.-H., Benz, A. P., & Gramley, F. (2017) · Clinical Research in Cardiology · doi:10.1007/s00392-017-1118-x · Cited by 8
Fu, B., Ran, B., Zhang, H., Luo, Y., & Wang, J. (2020) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-020-00772-4 · Cited by 8
Miyazaki, S., Hasegawa, K., Mukai, M., Aoyama, D., Nodera, M., Shiomi, Y., Tama, N., Ikeda, H., Ishida, K., Uzui, H., et al. (2021) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-021-00957-5 · Cited by 8
Suzuki, A., Fujiwara, R., Asada, H., Iwasa, K., Miyata, T., Song, W. H., Higuchi, K., Seo, H., Sakamoto, Y., Shimizu, M., et al. (2021) · Circulation Journal · doi:10.1253/circj.cj-21-0423 · Cited by 8
Lacoste, J. L., Szymanski, T. W., Avalon, J. C., Kabulski, G. M., Kohli, U., Marrouche, N. F., Singla, A., Balla, S., & Jahangir, A. (2022) · American Journal of Cardiovascular Drugs · doi:10.1007/s40256-022-00529-6 · Cited by 8
Treatment Options in AF Patients with Cancer; Focus on Catheter Ablation
Garibaldi, S., Chianca, M., Fabiani, I., Emdin, M., Piacenti, M., Passino, C., Aimo, A., Fedele, A., Cipolla, C. M., & Cardinale, D. M. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11154452 · Cited by 8
Rordorf, R., Iacopino, S., Verlato, R., Arena, G., Tondo, C., Molon, G., Manfrin, M., Rovaris, G., Perego, G. B., Sciarra, L., et al. (2022) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-022-01430-7 · Cited by 8
Self-citationIsgandarova, K., Bergau, L., Hamriti, M. E., BRAUN, M. U., Piran, M., Imnadze, G., Khalaph, M., Molatta, S., Sciacca, V., Fink, T., et al. (2023) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-023-01554-4 · Cited by 8
Difference in tissue temperature change between two cryoballoons
Hayashi, T., Hamada, K., Iwasaki, K., Takada, J., Murakami, M., & Saito, S. (2023) · Open Heart · doi:10.1136/openhrt-2023-002426 · Cited by 8
Urbanek, L., Schmidt, B., Bordignon, S., Schaack, D., Ebrahimi, R., Tohoku, S., Hirokami, J., Efe, T. H., Plank, K., Schulte‐Hahn, B., et al. (2024) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16302 · Cited by 8
Self-citationZhang, F., Geng, L., Zhang, J., Han, S., Guo, M., Xu, Y., & Chen, C. (2024) · Molecular and Cellular Biochemistry · doi:10.1007/s11010-024-05027-8 · Cited by 8
Ellis, E. R. (2017) · HeartRhythm Case Reports · doi:10.1016/j.hrcr.2016.10.004 · Cited by 8
Catheter ablation of persistent atrial fibrillation
Kettering, K., & Gramley, F. (2017) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-017-0498-y · Cited by 10
Cryoballoon ablation in atrial fibrillation: Advantages and drawbacks
Bovéda, S. (2017) · Revista Portuguesa de Cardiologia · doi:10.1016/j.repc.2017.09.008 · Cited by 8
Ng, B., Ilsar, R., McGuire, M. A., & Singarayar, S. (2018) · HeartRhythm Case Reports · doi:10.1016/j.hrcr.2018.09.010 · Cited by 8
Ding, J., Xu, J., Wei, M., Chen, B., Yang, P., Yu, Q., Sun, S., & Cheng, A. (2019) · BMC Cardiovascular Disorders · doi:10.1186/s12872-019-01295-1 · Cited by 8
Use of a radiofrequency guidewire to simplify workflow for left atrium access: a case series
Jauvert, G., Grimard, C., Alonso, C., & Lazarus, A. (2019) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-019-00615-x · Cited by 8
Willy, K., Wasmer, K., Dechering, D. G., Köbe, J., Lange, P. S., Bögeholz, N., Ellermann, C., Reinke, F., Frommeyer, G., & Eckardt, L. (2020) · Clinical Cardiology · doi:10.1002/clc.23485 · Cited by 8
Maj, R., Ceglia, S. D., Piazzi, E., Pozzi, M., Montemerlo, E., Casiraghi, M., Fienga, M., Gressoni, S., & Rovaris, G. (2021) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14998 · Cited by 8
Kobori, A., Sasaki, Y., Pak, M., Okada, T., Toyota, T., Kim, K., Kitai, T., Ehara, N., Kinoshita, M., Kaji, S., et al. (2021) · Heart Rhythm O2 · doi:10.1016/j.hroo.2021.03.009 · Cited by 8
Kühne, M., Knecht, S., Spies, F., Aeschbacher, S., Haaf, P., Zellweger, M. J., Schaer, B. A., Osswald, S., & Sticherling, C. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.664538 · Cited by 8
Usuda, K., Kato, T., Tsuda, T., Tada, H., Niwa, S., Usui, S., Sakata, K., Hayashi, K., Furusho, H., Kawashiri, M., et al. (2021) · Heart and Vessels · doi:10.1007/s00380-021-01929-5 · Cited by 8
Iacopino, S., Stabile, G., Fassini, G. M., Simone, A. D., Petretta, A., Moltrasio, M., Rocca, V. L., Placentino, F., Riva, S. I., Pesce, F., et al. (2021) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-021-01063-2 · Cited by 8
Self-citationMiyazaki, S., Sekihara, T., Hasegawa, K., Mukai, M., Aoyama, D., Nodera, M., & Tada, H. (2021) · International Journal of Cardiology · doi:10.1016/j.ijcard.2021.12.039 · Cited by 8
Zhang, P., Wang, M., Liu, W., Sun, P., Cai, S., Pan, Y., & Zhao, Q. (2022) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-022-01128-w · Cited by 8
Mol, D., Mulder, M. J., Veenstra, R., Allaart, C. P., Hof, I. E., Kemme, M. J. B., Khan, M., Kimman, G. P., Mairuhu, G., de Ruiter, G. S., et al. (2022) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15441 · Cited by 7
Yokoyama, M., Tokuda, M., Tokutake, K., Sato, H., Oseto, H., Yokoyama, K., Kato, M., Narui, R., Tanigawa, S., Yamashita, S., et al. (2022) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2022.101020 · Cited by 8
Bergau, L., Sciacca, V., Nesapiragasan, V., Rubarth, K., Konietschke, F., Fink, T., Hamriti, M. E., Imnadze, G., Dagher, L., BRAUN, M. U., et al. (2022) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15512 · Cited by 8
Pulsed‐field ablation: What are the unknowns and when will they cease to concern us?
Steiger, N. A., & Romero, J. E. (2022) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15521 · Cited by 8
First in-human modified atrial septostomy combining radiofrequency ablation and balloon dilation
Yan, C., Wan, L., Li, H., Wang, C., Guo, T., Niu, H., Li, S., Yundan, P., Wang, L., & Fang, W. (2022) · Heart · doi:10.1136/heartjnl-2022-321212 · Cited by 8
Xu, C., Jiang, S., Zou, L., Lu, S., Shi, G., Xu, B., Wang, Z., Xu, D., Xie, X., Luo, J., et al. (2022) · Cancer · doi:10.1002/cncr.34563 · Cited by 8
Nelson, D. W., Dhore-Patil, A., Kreidieh, O., Mekhael, M., Noujaim, C., Assaf, A. Y. M., Feng, H., & Marrouche, N. F. (2023) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15879 · Cited by 7
Boehmer, A. A., Rothe, M., Keim, C., Nussbaum, E., Wiedenmann, L. C., Schneider, K. Y., Spork, P., Ruckes, C., Dobre, B. C., Kaess, B. M., et al. (2024) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2024.01.027 · Cited by 8
Wei, H., Guo, X., Zhou, G., Sun, Q., Yang, J., Luo, B., & Ma, J. (2018) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13644 · Cited by 8
Characterization of atrial flutter after pulmonary vein isolation by cryoballoon ablation
Baman, J. R., Kaplan, R. M., Diaz, C. L., Peigh, G., Bavishi, A. A., Trivedi, A. D., Wasserlauf, J., Chicos, A. B., Arora, R., Kim, S., et al. (2019) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-019-00560-9 · Cited by 8
Sensi, F. D. (2018) · Journal of Atrial Fibrillation · doi:10.4022/jafib.2083 · Cited by 8
Metadata
- Authors
- Kuck, K.-H., Brugada, J., Fürnkranz, A., Metzner, A., Ouyang, F., Chun, K. R. J., Elvan, A., Arentz, T., Bestehorn, K., Pocock, S. J., Albenque, J.-P., & Tondo, C.
- Affiliations
- University of Milan (IT)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2016-06-09
- Volume
- 374
- Issue
- 23
- Pages
- 2235-2245
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2333001326
- Cited by
- 1,950
- References
- 22
- Citations by year
- 2026: 127 · 2025: 182 · 2024: 184 · 2023: 194 · 2022: 201 · 2021: 218 · 2020: 223 · 2019: 196 · 2018: 176 · 2017: 179 · 2016: 67
- FWCI
- 169.93
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- LSHTM Research Online (London School of Hygiene and Tropical Medicine) (acceptedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- paroxysmal atrial fibrillation, cryoballoon ablation, radiofrequency ablation, pulmonary vein isolation, catheter ablation, non-inferiority, drug-refractory atrial fibrillation, atrial flutter, atrial tachycardia, antiarrhythmic drug use, repeat ablation, treatment-related adverse events, mortality, cerebrovascular events
- MeSH terms
- Aged, Atrial Fibrillation, Cryosurgery, Female, Follow-Up Studies, Humans, Male, Middle Aged, Postoperative Complications, Recurrence, Reoperation, Single-Blind Method, Catheter Ablation, Disease-Free Survival, Kaplan-Meier Estimate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review