The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial Fibrillation
Open accessAbstract
BACKGROUND: Current guidelines recommend pulmonary-vein isolation by means of catheter ablation as treatment for drug-refractory paroxysmal atrial fibrillation. Radiofrequency ablation is the most common method, and cryoballoon ablation is the second most frequently used technology. METHODS: We conducted a multicenter, randomized trial to determine whether cryoballoon ablation was noninferior to radiofrequency ablation in symptomatic patients with drug-refractory paroxysmal atrial fibrillation. The primary efficacy end point in a time-to-event analysis was the first documented clinical failure (recurrence of atrial fibrillation, occurrence of atrial flutter or atrial tachycardia, use of antiarrhythmic drugs, or repeat ablation) following a 90-day period after the index ablation. The noninferiority margin was prespecified as a hazard ratio of 1.43. The primary safety end point was a composite of death, cerebrovascular events, or serious treatment-related adverse events. RESULTS: A total of 762 patients underwent randomization (378 assigned to cryoballoon ablation and 384 assigned to radiofrequency ablation). The mean duration of follow-up was 1.5 years. The primary efficacy end point occurred in 138 patients in the cryoballoon group and in 143 in the radiofrequency group (1-year Kaplan-Meier event rate estimates, 34.6% and 35.9%, respectively; hazard ratio, 0.96; 95% confidence interval [CI], 0.76 to 1.22; P<0.001 for noninferiority). The primary safety end point occurred in 40 patients in the cryoballoon group and in 51 patients in the radiofrequency group (1-year Kaplan-Meier event rate estimates, 10.2% and 12.8%, respectively; hazard ratio, 0.78; 95% CI, 0.52 to 1.18; P=0.24). CONCLUSIONS: In this randomized trial, cryoballoon ablation was noninferior to radiofrequency ablation with respect to efficacy for the treatment of patients with drug-refractory paroxysmal atrial fibrillation, and there was no significant difference between the two methods with regard to overall safety. (Funded by Medtronic; FIRE AND ICE ClinicalTrials.gov number, NCT01490814.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“achievable by point-by-point radiofrequency ablation, linear lesions encircling the pulmonary veins, or cryoballoon ablation, with similar outcomes.[732][733][734]”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [734]
In the citing paper
“It also seems even less common after cryoballoon ablation, 734”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [734]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins.
Haïssaguerre, M., Jaïs, P., Shah, D. C., Takahashi, A., Hocini, M., Quiniou, G., Garrigue, S., Mouroux, A. L., Métayer, P. L., & Clémenty, J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199809033391003 · Cited by 8,040
Approaches to catheter ablation for persistent atrial fibrillation
Verma, A., Jiang, C.-Y., Betts, T. R., Chen, J., Deisenhofer, I., Mantovan, R., Macle, L., Morillo, C. A., Haverkamp, W., Weerasooriya, R., et al. (2015) · New England Journal of Medicine · doi:10.1056/nejmoa1408288 · Cited by 2,339
Self-citationCalkins, H. G., Kück, K., Cappato, R., Brugada, J., Camm, A. J., Chen, S., Crijns, H. J. G. M., Damiano, R. J., Davies, D. W., Dimarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,685
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citationWilber, D. J., Pappone, C., Neuzil, P., De Paola, A., Marchlinski, F., Natale, A., Macle, L., Daoud, E. G., Calkins, H., Hall, B., et al. (2010) · JAMA · doi:10.1001/jama.2009.2029 · Cited by 1,170
Cryoballoon Ablation of Pulmonary Veins for Paroxysmal Atrial Fibrillation
Packer, D. L., Kowal, R. C., Wheelan, K. R., Irwin, J. M., Champagne, J., Guerra, P. G., Dubuc, M., Reddy, V. Y., Nelson, L., Holcomb, R. G., et al. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.064 · Cited by 919
Paroxysmal AF Catheter Ablation With a Contact Force Sensing Catheter
Natale, A., Reddy, V. Y., Monir, G., Wilber, D. J., Lindsay, B. D., McElderry, H. T., Kantipudi, C., MANSOUR, M. C., Melby, D. P., Packer, D. L., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.04.072 · Cited by 476
Kautzner, J., Neužil, P., Lambert, H., Peichl, P., Petrů, J., Cihak, R. J., Skoda, J., Wichterle, D., Wißner, E., Yulzari, A., et al. (2015) · EP Europace · doi:10.1093/europace/euv057 · Cited by 374
Luik, A., Radzewitz, A., Kieser, M., Walter, M., Bramlage, P., Hörmann, P., Schmidt, K., Horn, N., Brinkmeier-Theofanopoulou, M., Kunzmann, K., et al. (2015) · Circulation · doi:10.1161/circulationaha.115.016871 · Cited by 275
Kuck, K.-H., Hoffmann, B. A., Ernst, S., Wegscheider, K., Treszl, A., Metzner, A., Eckardt, L., Lewalter, T., Breithardt, G., & Willems, S. (2016) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.115.003337 · Cited by 261
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Items 201–300 of 1,000
Atrial fibrillation ablation using cryoballoon technology: Recent advances and practical techniques
Chen, S., Schmidt, B., Bordignon, S., Bologna, F., Perrotta, L., Nagase, T., & Chun, K. R. J. (2018) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13607 · Cited by 38
Self-citationTokutake, K., Tokuda, M., Yamashita, S., Sato, H., Ikewaki, H., Okajima, E., Oseto, H., Yokoyama, M., Isogai, R., Yokoyama, K., et al. (2019) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2019.08.003 · Cited by 38
Wats, K., Kiser, A. C., St Clair Cardiovascular Surgical Associates, P., Makati, K. J., Tampa Cardiac Specialists, L., Sood, N. A., Southcoast Health, F. R., DeLurgio, D. B., Greenberg, Y. J., & Yang, F. (2020) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2019.20 · Cited by 37
Rovaris, G., Ciconte, G., Schiavone, M., Mitacchione, G., Gasperetti, A., Piazzi, E., Negro, G., Montemerlo, E., Rondine, R., Pozzi, M., et al. (2021) · EP Europace · doi:10.1093/europace/euab085 · Cited by 38
Heeger, C.-H. H., Pott, A., Sohns, C., Riesinger, L. M., Sommer, P., Gasperetti, A., Tondo, C., Fassini, G. M., Moser, F., Lucas, P., et al. (2022) · EP Europace · doi:10.1093/europace/euac148 · Cited by 37
Self-citationRusso, A. D., Tondo, C., Schillaci, V., Casella, M., Iacopino, S., Bianchi, S., Fassini, G. M., Rossillo, A., Compagnucci, P., Schiavone, M., et al. (2023) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-023-01699-2 · Cited by 37
Self-citationCatheter ablation of atrial fibrillation in very young adults: a 5-year follow-up study
Saguner, A. M., Maurer, T., Wißner, E., Santoro, F., Lemeš, C., Mathew, S., Sohns, C., Heeger, C.-H. H., Reißmann, B., Riedl, J., et al. (2016) · EP Europace · doi:10.1093/europace/euw378 · Cited by 36
Self-citationKajiyama, T., Miyazaki, S., Matsuda, J., Watanabe, T., Niida, T., Takagi, T., Nakamura, H., Taniguchi, H., Hachiya, H., & Iesaka, Y. (2017) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2017.01.004 · Cited by 37
Hachem, A. H., Marine, J. E., Tahboub, H. A., Kamdar, S., Kanjwal, S., Soni, R., & Kanjwal, K. (2018) · Cardiology Research and Practice · doi:10.1155/2018/6276241 · Cited by 38
Secular trends in success rate of catheter ablation for atrial fibrillation: The SMASH-AF cohort
Perino, A. C., Leef, G. C., Cluckey, A., Yunus, F. N., Askari, M., Heidenreich, P. A., Narayan, S. M., Wang, P. J., & Turakhia, M. P. (2018) · American Heart Journal · doi:10.1016/j.ahj.2018.10.006 · Cited by 38
Kochi, A. N., Moltrasio, M., Tundo, F., Riva, S. I., Ascione, C., Dessanai, M. A., Pizzamiglio, F., Vettor, G., Cellucci, S., Gasperetti, A., et al. (2021) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14930 · Cited by 37
Self-citationTen-year trends in mortality and complications following catheter ablation of atrial fibrillation
Ngo, L., Alı̀, A., Ganesan, A. N., Woodman, R. J., Adams, R. J., & Ranasinghe, I. (2022) · European Heart Journal - Quality of Care and Clinical Outcomes · doi:10.1093/ehjqcco/qcab102 · Cited by 37
Mol, D., Renskers, L., Balt, J. C., Bhagwandien, R. E., Blaauw, Y., van Driel, V. J. H. M., Driessen, A. H. G., Elvan, A., Folkeringa, R., Hassink, R. J., et al. (2022) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15368 · Cited by 37
Self-citationInitial experience with pulsed field ablation for atrial fibrillation
Magni, F. T., Mulder, B. A., Groenveld, H. F., Wiesfeld, A. C. P., Tieleman, R. G., Cox, M. G. P. J., Gelder, I. C. V., Smilde, T., Tan, E. S., Rienstra, M., et al. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.959186 · Cited by 37
Wörmann, J., Schipper, J., Lüker, J., van den Bruck, J., Filipovic, K., Erlhöfer, S., Pavel, F., Scheurlen, C., Dittrich, S., Steven, D., et al. (2023) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16101 · Cited by 36
Tilz, R. R., Feher, M., Vogler, J., Bode, K., Duta, A. I., Ortolan, A., Lopez, L. D., Küchler, M., Mamaev, R., Lyan, E., et al. (2024) · EP Europace · doi:10.1093/europace/euae105 · Cited by 36
Learning curve using the second-generation cryoballoon ablation
Velagić, V., de Asmundis, C., Mugnai, G., Hünük, B., Hacioğlu, E., Ströker, E., Moran, D., Ruggiero, D., Poelaert, J., Verborgh, C., et al. (2016) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000000493 · Cited by 36
Yokokawa, M., Chugh, A., Latchamsetty, R., Ghanbari, H., Crawford, T. C., Jongnarangsin, K., Cunnane, R. T., Saeed, M., Sunkara, B., Tezcan, M., et al. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.06.047 · Cited by 36
Bavishi, A. A., Kaplan, R. M., Peigh, G., Diaz, C. L., Baman, J. R., Trivedi, A. D., Wasserlauf, J., Shen, M. J., Sattayaprasert, P., Chicos, A. B., et al. (2019) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13669 · Cited by 36
Left atrial contractile strain predicts recurrence of atrial tachyarrhythmia after catheter ablation
Nielsen, A. B., Skaarup, K. G., Djernæs, K., Hauser, R., Estépar, R. S. J., Sørensen, S. K., Ruwald, M. H., Hansen, M. L., Worck, R. H., Johannessen, A. C., et al. (2022) · International Journal of Cardiology · doi:10.1016/j.ijcard.2022.04.056 · Cited by 36
Miyazaki, S., Kajiyama, T., Watanabe, T., Hada, M., Yamao, K., Kusa, S., Igarashi, M., Nakamura, H., Hachiya, H., Tada, H., et al. (2018) · Journal of the American Heart Association · doi:10.1161/jaha.117.008249 · Cited by 36
Tokuda, M., Matsuo, S., Isogai, R., Uno, G., Tokutake, K., Yokoyama, K., Kato, M., Narui, R., Tanigawa, S., Yamashita, S., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.08.018 · Cited by 35
Bronchial effects of cryoballoon ablation for atrial fibrillation
Verma, N., Gillespie, C. T., Argento, A. C., Tomson, T. T., Dandamudi, S., Piña, P., Ringwala, S. M., LIN, A. C., Chicos, A. B., Kim, S. W., et al. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.10.012 · Cited by 35
Hamaya, R., Miyazaki, S., Taniguchi, H., Kusa, S., Nakamura, H., Hachiya, H., Kajiyama, T., Watanabe, T., Igarashi, M., Hirao, K., et al. (2017) · EP Europace · doi:10.1093/europace/eux307 · Cited by 35
Okumura, Y., Nagashima, K., Arai, M., Watanabe, R., Yokoyama, K., Matsumoto, N., Otsuka, T., Suzuki, S. S., Hirata, A., Murakami, M., et al. (2019) · Circulation Journal · doi:10.1253/circj.cj-19-0602 · Cited by 35
Gu, G., Wu, J., Gao, X., Liu, M., Jin, C., & Xu, Y. (2022) · Clinical Cardiology · doi:10.1002/clc.23841 · Cited by 35
Pathogenesis, Evaluation, and Management of Pulmonary Vein Stenosis
Simard, T., Sarma, D., Miranda, W. R., Jain, C. C., Anderson, J. H., Collins, J. D., Sabbagh, A. E., Jhand, A., Peikert, T., Reeder, G. S., et al. (2023) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.04.016 · Cited by 34
Wahedi, R., Willems, S., Feldhege, J., Jularic, M., Hartmann, J., Anwar, O., Dickow, J., Harloff, T., Geßler, N., & Gunawardene, M. (2023) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16141 · Cited by 35
Yalın, K., Abdin, A., Lyan, E., Sawan, N., Liosis, S., Elsner, C., Jobs, A., Brüggemann, B., Köster, J., Eitel, I., et al. (2018) · Clinical Research in Cardiology · doi:10.1007/s00392-018-1219-1 · Cited by 32
Does YouTube provide high-quality resources for patient education on atrial fibrillation ablation?
Camm, C. F., Russell, E. A., Ji‐Xu, A., & Rajappan, K. (2018) · International Journal of Cardiology · doi:10.1016/j.ijcard.2018.08.066 · Cited by 34
Andrade, J. G., Champagne, J., Deyell, M. W., Essebag, V., Lauck, S., Morillo, C. A., Sapp, J. L., Skanes, A. C., Theoret-Patrick, P., Wells, G. A., et al. (2018) · American Heart Journal · doi:10.1016/j.ahj.2018.05.020 · Cited by 34
Risk of atrioesophageal fistula with cryoballoon ablation of atrial fibrillation
Piccini, J. P., Braegelmann, K. M., Simma, S., Koneru, J. N., & Ellenbogen, K. A. (2020) · Heart Rhythm O2 · doi:10.1016/j.hroo.2020.05.007 · Cited by 34
Kurose, J., Kiuchi, K., Fukuzawa, K., Takami, M., Mori, S., Suehiro, H., Nagamatsu, Y., Akita, T., Takemoto, M., Yatomi, A., et al. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14664 · Cited by 33
Ultralow temperature cryoablation: Safety and efficacy of preclinical atrial and ventricular lesions
Bourier, F. J., Takigawa, M., Lam, A., Vlachos, K. G., Ramirez, F. D., Martin, C., Frontera, A., Kitamura, Τ., Duchâteau, J., Pambrun, T., et al. (2021) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14907 · Cited by 34
Pulmonary vein isolation with the radiofrequency balloon catheter: a single centre prospective study
Monte, A. D., Almorad, A., Pannone, L., Rocca, D. G. D., Bisignani, A., Monaco, C., Mouram, S., Ramak, R., Gauthey, A., Overeinder, I., et al. (2023) · EP Europace · doi:10.1093/europace/euad017 · Cited by 34
High-Frequency Low-Tidal Volume Ventilation Improves Long-Term Outcomes in AF Ablation
Osorio, J., Zei, P. C., Díaz, J. C., Varley, A. L., MORALES, G. X., Silverstein, J. R., Oza, S. R., D'Souza, B. A., Singh, D., Moretta, A., et al. (2023) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2023.05.015 · Cited by 34
Qualitätskriterien zur Durchführung der Katheterablation von Vorhofflimmern
Kück, K., Böcker, D., Chun, K. R. J., Deneke, T., Hindricks, G., Hoffmann, E., Piorkowski, C., & Willems, S. (2017) · Der Kardiologe · doi:10.1007/s12181-017-0146-0 · Cited by 31
Self-citationTissue Ablation: Applications and Perspectives
Keum, H., Çevik, E., Kim, J., Demirlenk, Y. M., Atar, D., Saini, G., Sheth, R. A., Deipolyi, A. R., & Öklü, R. (2024) · Advanced Materials · doi:10.1002/adma.202310856 · Cited by 33
Tscholl, V., Lin, T., Lsharaf, A. K., Bellmann, B., Nagel, P., Lenz, K., Landmesser, U., Roser, M., & Rillig, A. (2017) · EP Europace · doi:10.1093/europace/eux128 · Cited by 33
Beiert, T., Lodde, P. C., Linneborn, L. P. T., Werner, J. T., Prinz, L., Stöckigt, F., Linhart, M., Lickfett, L., Nickenig, G., SCHRICKEL, J. W., et al. (2017) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13247 · Cited by 33
Rapid pulmonary vein isolation utilizing the third-generation laserballoon – The PhoeniX registry
Heeger, C.-H. H., Tiemeyer, C. M., Phan, H., Meyer‐Saraei, R., Fink, T., Sciacca, V., Liosis, S., Brüggemann, B., Große, N., Fahimi, B., et al. (2020) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2020.100576 · Cited by 33
Self-citationGroen, M. H. A., van Es, R., van Klarenbosch, B. R., Stehouwer, M. C., Loh, P. K. K., Doevendans, P. A., Wittkampf, F. H. M., & Neven, K. G. E. J. (2020) · EP Europace · doi:10.1093/europace/euaa243 · Cited by 33
Watanabe, R., Nagashima, K., Wakamatsu, Y., Otsuka, N., Yokoyama, K., Matsumoto, N., Otsuka, T., Suzuki, S. S., Hirata, A., Murakami, M., et al. (2021) · Circulation Journal · doi:10.1253/circj.cj-21-0326 · Cited by 33
Catheter ablation for atrial fibrillation in elderly patients: Systematic review and a meta‐analysis
Kawamura, I., Aikawa, T., Yokoyama, Y., Takagi, H., & Kuno, T. (2021) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14413 · Cited by 33
Edriss, H., Denega, T., Test, V. J., & NUGENT, K. M. (2016) · Respiratory Medicine · doi:10.1016/j.rmed.2016.06.014 · Cited by 33
Mililis, P., Kariki, O. K., Saplaouras, A., Bazoukis, G., Dragasis, S., Patsiotis, I. G., Batsouli, A., Vlachos, K. G., Letsas, Κ. P., & Efremidis, M. (2023) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.15965 · Cited by 33
Pulsed-field- vs. cryoballoon-based pulmonary vein isolation: lessons from repeat procedures
Lemoine, M. D., Obergassel, J., Jaeckle, S., Nies, M., Taraba, S., Mencke, C., Rieß, J., My, I., Rottner, L., Moser, F., et al. (2024) · EP Europace · doi:10.1093/europace/euae221 · Cited by 32
Self-citationLatchamsetty, R., & Morady, F. (2017) · Annual Review of Medicine · doi:10.1146/annurev-med-041316-090015 · Cited by 32
Pott, A., Kraft, C., Stephan, T., Petscher, K., Rottbauer, W., & Dahme, T. (2018) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.11.039 · Cited by 32
Kraft, M., Büscher, A., Wiedmann, F., L’hoste, Y., Haefeli, W. E., Frey, N., Katus, H. A., & Schmidt, C. (2021) · Frontiers in Pharmacology · doi:10.3389/fphar.2021.638445 · Cited by 31
Kany, S., Reißmann, B., Metzner, A., Kirchhof, P. F., Darbar, D., & Schnabel, R. B. (2021) · Cardiovascular Research · doi:10.1093/cvr/cvab153 · Cited by 32
Self-citationMcCarthy, P. M., Cox, J. L., Kislitsina, O. N., Kruse, J. T., Churyla, A., Malaisrie, S. C., & Mehta, C. K. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm11010210 · Cited by 31
New energy sources and technologies for atrial fibrillation catheter ablation
Boersma, L. V. A. (2021) · EP Europace · doi:10.1093/europace/euab258 · Cited by 33
Hisazaki, K., Hasegawa, K., Kaseno, K., Miyazaki, S., Amaya, N., Shiomi, Y., Tama, N., Ikeda, H., Fukuoka, Y., Morishita, T., et al. (2018) · Heart and Vessels · doi:10.1007/s00380-018-1257-7 · Cited by 32
Pierucci, N., Mariani, M. V., Laviola, D., Silvetti, G., Cipollone, P., Vernile, A., Trivigno, S., Fazia, V. M. L., Piro, A., Miraldi, F., et al. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13102980 · Cited by 32
Bisignani, A., Schiavone, M., Solimene, F., Russo, A. D., Filannino, P., Magnocavallo, M., Tondo, C., Schillaci, V., Casella, M., Petretta, A., et al. (2024) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-024-01835-6 · Cited by 30
Self-citationConsiderations regarding safety with pulsed field ablation for atrial fibrillation
Sugrue, A. M., Shabtaie, S. A., Tan, N. Y. L., Maor, E., Kapa, S., & Asirvatham, S. J. (2024) · Heart Rhythm O2 · doi:10.1016/j.hroo.2024.08.002 · Cited by 31
Chen, C.-F., Gao, X., Duan, X., Chen, B., Liu, X., & Xu, Y. (2017) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-016-0220-8 · Cited by 31
Andrade, J. G., Deyell, M. W., Badra‐Verdu, M., Champagne, J., Dubuc, M., Leong‐Sit, P., Macle, L., NOVAK, P. G., Roux, J.-F., Sapp, J. L., et al. (2017) · BMJ Open · doi:10.1136/bmjopen-2017-017970 · Cited by 31
Voskoboinik, A., SPARKS, P. B., Morton, J. B., Lee, G., Joseph, S., Hawson, J. J., Kistler, P. M., & Kalman, J. M. (2018) · Heart Lung and Circulation · doi:10.1016/j.hlc.2018.01.002 · Cited by 31
Γιαννόπουλος, Γ., Kossyvakis, C., Vrachatis, D. A., Aggeli, C., Tsitsinakis, G., Letsas, Κ. P., Tsiachris, D., Tsoukala, S., Efremidis, M., Katritsis, D., et al. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13933 · Cited by 32
Tokuda, M., Yamashita, S., Matsuo, S., Kato, M., Sato, H., Oseto, H., Okajima, E., Ikewaki, H., Yokoyama, M., Isogai, R., et al. (2019) · PLoS ONE · doi:10.1371/journal.pone.0219269 · Cited by 30
Ablation of persistent atrial fibrillation: Challenges and solutions
Terricabras, M., Piccini, J. P., & Verma, A. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14311 · Cited by 30
Atrial Tachycardias After Atrial Fibrillation Ablation: How to Manage?
Hung, Y., Chen, S., Chang, S., Lin, W., & Lin, W. (2020) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2020.07 · Cited by 31
Kaba, R. A., Momin, A., & Camm, A. J. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10143129 · Cited by 31
Müller, P., Weijs, B., Bemelmans, N. M. A. A., Mügge, A., Eckardt, L., Crijns, H. J. G. M., Bax, J. J., Linz, D., & den Uijl, D. W. (2021) · Clinical Research in Cardiology · doi:10.1007/s00392-021-01917-9 · Cited by 32
Servatius, H., Küffer, T., Baldinger, S. H., Asatryan, B., Seiler, J., Tanner, H., Novak, J., Lam, A., Noti, F., Haeberlin, A., et al. (2021) · Heart Rhythm · doi:10.1016/j.hrthm.2021.12.028 · Cited by 31
Radiofrequency catheter ablation of atrial fibrillation: A review of techniques
Calvert, P. A. R., Lip, G. Y. H., & Gupta, D. (2022) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2022.04.002 · Cited by 31
Pieragnoli, P., Perini, A. P., Ricciardi, G., Checchi, L., Giomi, A., Muraca, I., Mannucci, L., & Padeletti, L. (2017) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13190 · Cited by 31
Dong, Y., Zhao, D., Chen, X., Shi, L., Chen, Q., Zhang, H., Yu, Y., Ullah, I., Kojodjojo, P., & Zhang, F. (2024) · EP Europace · doi:10.1093/europace/euae039 · Cited by 30
Osorio, J., Miranda‐Arboleda, A. F., Velasco, A., Varley, A. L., Rajendra, A. B., MORALES, G. X., Hoyos, C., Matos, C. D., Thorne, C., D'Souza, B. A., et al. (2024) · Heart Rhythm · doi:10.1016/j.hrthm.2024.04.090 · Cited by 30
Miyamoto, K., Doi, A., Hasegawa, K., Morita, Y., Mishima, T., Suzuki, I., Kaseno, K., Nakajima, K., Kataoka, N., Kamakura, T., et al. (2019) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.118.006989 · Cited by 30
Pivotal Study of a Novel Motor-Driven Endoscopic Ablation System
Schmidt, B., Petrů, J., Chun, K. R. J., Šedivá, L., Bordignon, S., Chen, S., & Neužil, P. (2021) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.120.009544 · Cited by 30
Self-citationAnić, A., Lever, N. A., Martin, A., Brešković, T., Sulkin, M. S., Duffy, E., Saliba, W. I., Niebauer, M. J., Wazni, O. M., & Varma, N. (2021) · EP Europace · doi:10.1093/europace/euab018 · Cited by 30
Luik, A., Kunzmann, K., Hörmann, P., Schmidt, K., Radzewitz, A., Bramlage, P., Schenk, T., Schymik, G., Merkel, M., Kieser, M., et al. (2017) · BMC Cardiovascular Disorders · doi:10.1186/s12872-017-0566-6 · Cited by 30
Fassini, G. M., Gasperetti, A., Italiano, G., Riva, S. I., Moltrasio, M., Russo, A. D., Casella, M., Maltagliati, A. C., Tundo, F., Majocchi, B., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2019.03.022 · Cited by 30
Self-citationMeta‐analysis of pulsed‐field ablation versus cryoablation for atrial fibrillation
Zhang, H., Zhang, H., Lu, H., Mao, Y., & Chen, J. (2024) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.14971 · Cited by 29
Padeletti, L., Curnis, A., Tondo, C., Lunati, M., Porcellini, S., Verlato, R., Sciarra, L., SENATORE, G., Catanzariti, D., Leoni, L., et al. (2016) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.12975 · Cited by 29
Self-citationIkenouchi, T., Nitta, J., Nitta, G., Kato, S., Iwasaki, T., Murata, K., Matsuda, J., Hirao, T., Kanoh, M., Takamiya, T., et al. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.12.019 · Cited by 29
Główniak, A., Tarkowski, A., Fic, P., Wojewoda, K., Wójcik, J., & Wysokiński, A. P. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13938 · Cited by 29
Moltrasio, M., Sicuso, R., Fassini, G. M., Riva, S. I., Tundo, F., Russo, A. D., Casella, M., Majocchi, B., Zucchetti, M., Cellucci, S., et al. (2019) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13718 · Cited by 29
Self-citationCatheter ablation for the management of atrial fibrillation: current technical perspectives
Hong, K. L., Borges, J. P., & Glover, B. M. (2020) · Open Heart · doi:10.1136/openhrt-2019-001207 · Cited by 30
Chen, S., Schmidt, B., Bordignon, S., Tohoku, S., URBAN, V., Schulte‐Hahn, B., & Chun, K. R. J. (2021) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14912 · Cited by 29
Self-citationPak, H., Park, J., Yang, S.-Y., Kim, T., Uhm, J., Joung, B., Lee, M., Yu, H. T., & for the CRAFT Investigators (2021) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.121.010040 · Cited by 30
Bahlke, F., Englert, F., Popa, M. A., Bourier, F. J., Reents, T., Lennerz, C., Kraft, H., Martinez, A. T., Kottmaier, M., Syväri, J., et al. (2024) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16184 · Cited by 29
Cryoballoon Ablation for Atrial Fibrillation: a Comprehensive Review and Practice Guide
Jin, E., & Wang, P. J. (2017) · Korean Circulation Journal · doi:10.4070/kcj.2017.0318 · Cited by 29
Pulsed Field Ablation of Atrial Fibrillation: A Comprehensive Review
Matos, C. D., Hoyos, C., Miranda‐Arboleda, A. F., Díaz, J. C., Hincapie, D., Patiño, C., Hernadez, R. H., Zei, P. C., Romero, J. E., & Osorio, J. (2023) · Reviews in Cardiovascular Medicine · doi:10.31083/j.rcm2411337 · Cited by 29
Chaumont, C., Hayoun, C., Savouré, A., Hamoud, R. A., Auquier, N., McDonnell, E., Eltchaninoff, H., & Anselme, F. (2024) · Journal of the American Heart Association · doi:10.1161/jaha.123.033146 · Cited by 29
Radiofrequency Catheter Ablation For Atrial Fibrillation: Approaches And Outcomes
Kalla, M., Sanders, P., Kalman, J. M., & Lee, G. (2017) · Heart Lung and Circulation · doi:10.1016/j.hlc.2017.05.125 · Cited by 29
Kück, K., Brugada, J., Schlüter, M., Braegelmann, K. M., Kueffer, F. J., Chun, K. R. J., Albenque, J., Tondo, C., Calkins, H. G., on behalf of the FIRE AND ICE Trial Investigators, et al. (2018) · Journal of the American Heart Association · doi:10.1161/jaha.118.010777 · Cited by 29
Self-citationNakamura, R. A., Okishige, K., Shigeta, T., Nishimura, T., Kurabayashi, M., Yamauchi, Y., Sasano, T., & Hirao, K. (2019) · Journal of Cardiology · doi:10.1016/j.jjcc.2019.02.003 · Cited by 28
A nurse‐led implantable loop recorder service is safe and cost effective
Lim, W. Y., Παπαγεωργίου, Ν., Sukumar, S., Alexiou, S., Srinivasan, N. T., Monkhouse, C. A., Daw, H., Caldeira, H., Harvie, H., Kuriakose, J., et al. (2019) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14206 · Cited by 28
Cryoballoon ablation for pulmonary vein isolation
Andrade, J. G. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14459 · Cited by 28
Knecht, S., Sticherling, C., Roten, L., Badertscher, P., Chollet, L., Küffer, T., Spies, F., Madaffari, A., Mühl, A., Baldinger, S. H., et al. (2021) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-021-01035-6 · Cited by 28
Li, F., Sun, J.-Y., Wu, L., Zhang, L., Qu, Q., Wang, C., Qian, L., & Wang, R. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.871654 · Cited by 28
Composite Index Tagging for PVI in Paroxysmal AF
Biase, L. D., Monir, G., Melby, D. P., Tabereaux, P. B., Natale, A., Manyam, H., Athill, C. A., Delaughter, C., Patel, A. M., Gentlesk, P. J., et al. (2022) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2022.06.007 · Cited by 28
Heeger, C.-H. H., Popescu, S. S., Inderhees, T., Nussbickel, N., Eitel, C., Kirstein, B., Phan, H., Hatahet, S., Subin, B., Traub, A., et al. (2023) · EP Europace · doi:10.1093/europace/euad248 · Cited by 28
Lyan, E., Yalın, K., Abdin, A., Sawan, N., Liosis, S., Lange, S. A., Eitel, I., Heeger, C.-H. H., Meyer‐Saraei, R., Eitel, C., et al. (2019) · Journal of Cardiology · doi:10.1016/j.jjcc.2019.02.006 · Cited by 27
Rudolph, I., Mastella, G., Bernlochner, I., Steger, A., von Olshausen, G., Hahn, F., Wakili, R., Laugwitz, K., Martens, E., & Rattka, M. (2024) · European Heart Journal Open · doi:10.1093/ehjopen/oeae044 · Cited by 27
Practical Techniques in Cryoballoon Ablation: How to Isolate Inferior Pulmonary Veins
Chen, S., Schmidt, B., Bordignon, S., Bologna, F., Nagase, T., Perrotta, L., & Chun, K. R. J. (2018) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2018;1;2 · Cited by 27
Self-citation
Metadata
- Authors
- Kuck, K.-H., Brugada, J., Fürnkranz, A., Metzner, A., Ouyang, F., Chun, K. R. J., Elvan, A., Arentz, T., Bestehorn, K., Pocock, S. J., Albenque, J.-P., & Tondo, C.
- Affiliations
- University of Milan (IT)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2016-06-09
- Volume
- 374
- Issue
- 23
- Pages
- 2235-2245
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W2333001326
- Cited by
- 1,950
- References
- 22
- Citations by year
- 2026: 127 · 2025: 182 · 2024: 184 · 2023: 194 · 2022: 201 · 2021: 218 · 2020: 223 · 2019: 196 · 2018: 176 · 2017: 179 · 2016: 67
- FWCI
- 169.93
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- LSHTM Research Online (London School of Hygiene and Tropical Medicine) (acceptedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- paroxysmal atrial fibrillation, cryoballoon ablation, radiofrequency ablation, pulmonary vein isolation, catheter ablation, non-inferiority, drug-refractory atrial fibrillation, atrial flutter, atrial tachycardia, antiarrhythmic drug use, repeat ablation, treatment-related adverse events, mortality, cerebrovascular events
- MeSH terms
- Aged, Atrial Fibrillation, Cryosurgery, Female, Follow-Up Studies, Humans, Male, Middle Aged, Postoperative Complications, Recurrence, Reoperation, Single-Blind Method, Catheter Ablation, Disease-Free Survival, Kaplan-Meier Estimate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review