The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation
Open accessAbstract
BACKGROUND: Optical sensors on wearable devices can detect irregular pulses. The ability of a smartwatch application (app) to identify atrial fibrillation during typical use is unknown. METHODS: Participants without atrial fibrillation (as reported by the participants themselves) used a smartphone (Apple iPhone) app to consent to monitoring. If a smartwatch-based irregular pulse notification algorithm identified possible atrial fibrillation, a telemedicine visit was initiated and an electrocardiography (ECG) patch was mailed to the participant, to be worn for up to 7 days. Surveys were administered 90 days after notification of the irregular pulse and at the end of the study. The main objectives were to estimate the proportion of notified participants with atrial fibrillation shown on an ECG patch and the positive predictive value of irregular pulse intervals with a targeted confidence interval width of 0.10. RESULTS: We recruited 419,297 participants over 8 months. Over a median of 117 days of monitoring, 2161 participants (0.52%) received notifications of irregular pulse. Among the 450 participants who returned ECG patches containing data that could be analyzed - which had been applied, on average, 13 days after notification - atrial fibrillation was present in 34% (97.5% confidence interval [CI], 29 to 39) overall and in 35% (97.5% CI, 27 to 43) of participants 65 years of age or older. Among participants who were notified of an irregular pulse, the positive predictive value was 0.84 (95% CI, 0.76 to 0.92) for observing atrial fibrillation on the ECG simultaneously with a subsequent irregular pulse notification and 0.71 (97.5% CI, 0.69 to 0.74) for observing atrial fibrillation on the ECG simultaneously with a subsequent irregular tachogram. Of 1376 notified participants who returned a 90-day survey, 57% contacted health care providers outside the study. There were no reports of serious app-related adverse events. CONCLUSIONS: The probability of receiving an irregular pulse notification was low. Among participants who received notification of an irregular pulse, 34% had atrial fibrillation on subsequent ECG patch readings and 84% of notifications were concordant with atrial fibrillation. This siteless (no on-site visits were required for the participants), pragmatic study design provides a foundation for large-scale pragmatic studies in which outcomes or adherence can be reliably assessed with user-owned devices. (Funded by Apple; Apple Heart Study ClinicalTrials.gov number, NCT03335800.).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Importantly, arrhythmia detection algorithms such as the irregular pulse notification in the Apple Heart Study (Perez et al., 2019) remained robust, with sensitivity for atrial fibrillation unaffected by skin tone across a large-scale population [15].”
From Photoplethysmography in Diverse Skin Tones: Evaluating Bias in Smartwatch Health Monitoring (2025) · cites this paper as [15]
Experimental — accuracy not yet measuredIn the citing paper
“While recent large-scale longitudinal studies have shown promise in leveraging wearable sensor data for health monitoring and prediction, they also introduce new challenges for data modelling.”
From Human-centred artificial intelligence for mobile health sensing: challenges and opportunities (2023) · cites this paper as [18]
In the citing paper
“PPG tachograms, especially when augmented by single-lead ECG, can also identify arrhythmias19.”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [19]
In the citing paper
“AF screening through PPG has shown variable accuracy depending on the algorithms and devices used19,51,52”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [19]
In the citing paper
“The positive predictive value for AF detection was 84% and 71% for the irregular notification algorithm and individual tachograms, respectively19.”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [19]
In the citing paper
“a common practice is to involve an accelerometer for artifact identification [11][12][13][27][28][29][30].”
From Modeling of artifacts in the wrist photoplethysmogram: Application to the detection of life-threatening arrhythmias (2021) · cites this paper as [11]
In the citing paper
“The positive predictive value (PPV) of notifications was found to be 0.84, indicating that wearables may have utility for identifying possible AF.”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [29]
In the citing paper
“In [29], an irregular pulse notification was generated if an irregular pulse was identified in at least five out of six PPG recordings in a 48-h period [29].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [29]
In the citing paper
“Initial work indicates that PPG signal quality is highest during sleep when movement and ambient light are minimal, supporting the approach of only acquiring PPG signals during periods of low activity [29].”
From Wearable Photoplethysmography for Cardiovascular Monitoring (2022) · cites this paper as [29]
In the citing paper
“The Apple Heart Study [15] is another example that was a breakthrough for showing that wearable devices may detect atrial fibrillation (AF) and foster a discussion of potentials and limitations with regard to health care providers, researchers, and members of the media and economy [16,17].”
From The impact of wearable technologies in health research: scoping review (2022) · cites this paper as [15]
In the citing paper
“For example, Fitbit alone has approximately 476 published studies and 449 studies registered on ClinicalTrials.gov [4] and the Apple Watch Heart Study recruited 419 927 people to track irregular heart rhythms [20].”
From Limiting racial disparities and bias for wearable devices in health science research (2020) · cites this paper as [20]
In the citing paper
“Researchers are increasingly using consumer wearables or wrist-worn smartwatches and fitness monitors for the digital measurement of cardiovascular health and psychophysiological stress as these devices allow for continuous, scalable, and unobtrusive, “big data” collection of overall cardiac activity in real-world conditions with large samples25–30.”
From Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research (2020) · cites this paper as [27]
In the citing paper
“However, if a study were interested in HR arrythmias using wearable assessments (such as atrial fibrillation), then these extreme values may be of vital interest and should not be removed or altered27.”
From Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research (2020) · cites this paper as [27]
In the citing paper
“Deep neural networks (DNNs) have emerged as a powerful tool for learning features and predictions from raw data in cardiology.12”
From Unlocking Tomorrow’s Health Care: Expanding the Clinical Scope of Wearables by Applying Artificial Intelligence (2024) · cites this paper as [12]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
Colilla, S., Crow, A., Petkun, W., Singer, D. E., Simon, T. A., & Liu, X. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.05.063 · Cited by 1,323
Passive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch
Tison, G. H., Sanchez, J. M., Ballinger, B., Singh, A., Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Lee, E. S., Fan, S. M., Gladstone, R. A., et al. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.0136 · Cited by 566
Steinhubl, S. R., Waalen, J., Edwards, A. M., Ariniello, L. M., Mehta, R. R., Ebner, G. S., Carter, C., Baca-Motes, K., Felicione, E., Sarich, T., et al. (2018) · JAMA · doi:10.1001/jama.2018.8102 · Cited by 539
Turakhia, M. P., Desai, M., Hedlin, H., Rajmane, A., Talati, N., Ferris, T., Desai, S., Nag, D., Patel, M., Kowey, P., et al. (2019) · American Heart Journal · doi:10.1016/j.ahj.2018.09.002 · Cited by 474
Self-citationGenetic Predisposition, Clinical Risk Factor Burden, and Lifetime Risk of Atrial Fibrillation
Weng, L.-C. C., Preis, S. R., Hulme, O. L., Larson, M. G., Choi, S. H., Wang, B., Trinquart, L., McManus, D. D., Stærk, L., Lin, H., et al. (2017) · Circulation · doi:10.1161/circulationaha.117.031431 · Cited by 276
Estimated prevalence of undiagnosed atrial fibrillation in the United States
Turakhia, M. P., Shafrin, J. T., Bognar, K., Trocio, J. N., Abdulsattar, Y., Wiederkehr, D., & Goldman, D. P. (2018) · PLoS ONE · doi:10.1371/journal.pone.0195088 · Cited by 180
Self-citationStrain, T., Wijndaele, K., & Brage, S. (2018) · JMIR mhealth and uhealth · doi:10.2196/11898 · Cited by 66
Flagged first, then by citations
Cited by
Sorted by citations
Items 701–800 of 1,002
Does asymptomatic atrial fibrillation exist?
Carneiro, H. A., & Knight, B. P. (2023) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.16108 · Cited by 11
Personalized ECG monitoring and adaptive machine learning
Shusterman, V., & London, B. (2023) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2023.12.006 · Cited by 10
An Update on the Use of Artificial Intelligence in Cardiovascular Medicine
Rao, S. J., Iqbal, S. B., Isath, A. M., Virk, H. U. H., Wang, Z., Glicksberg, B. S., & Krittanawong, C. (2024) · Hearts · doi:10.3390/hearts5010007 · Cited by 11
Saggu, D. K., Madappa, N. U., Sarkar, S., Sathiyamoorthy, A., Dash, S., Veerendranath Reddy, P., Rajan, V., & Calambur, N. (2024) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2024.08.003 · Cited by 10
Reznichenko, S., Whitaker, J., Ni, Z., & Zhou, S. (2024) · CJC Open · doi:10.1016/j.cjco.2024.10.012 · Cited by 15
Artificial intelligence for hemodynamic monitoring with a wearable electrocardiogram monitor
Schlesinger, D. E., Alam, R., Ringel, R., Pomerantsev, E. V., Devireddy, S., Shah, P. B., Garasic, J. M., & Stultz, C. M. (2025) · Communications Medicine · doi:10.1038/s43856-024-00730-5 · Cited by 10
Guio, F. D., Rienstra, M., Lillo-Castellano, J. M., Toribio‐Fernández, R., Lizcano, C., Corrochano-Diego, D., Virumbrales, D. J., & Breysse, M. M. (2025) · Heart Rhythm · doi:10.1016/j.hrthm.2024.12.048 · Cited by 10
Boyle, L. D., Giriteka, L., Marty, B., Steihaug, O. M., Haugarvoll, K., Sandgathe, L., Husebo, B. S., & Pătraşcu, M. (2025) · Sensors · doi:10.3390/s25030668 · Cited by 11
Diagnostic Strategies Using AI and ML in Cardiovascular Diseases: Challenges and Future Perspectives
Rana, N., Sharma, K., & Sharma, A. (2025) · Algorithms for intelligent systems · doi:10.1007/978-981-96-1285-7_7 · Cited by 11
Health Care 2025: How Consumer-Facing Devices Change Health Management and Delivery
Trinh, S., Skoll, D., & Saxon, L. A. (2025) · Journal of Medical Internet Research · doi:10.2196/60766 · Cited by 12
PPG Earring: Wireless Smart Earring for Heart Health Monitoring
Xue, Q. S., Nissanka, D., Yan, J. T., Wang, R., Patel, S., & Iyer, V. (2025) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3706598.3713856 · Cited by 10
Keys, R., Marshall, P., Stuart, G., & O’Kane, A. A. (2025) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3706598.3713326 · Cited by 13
Reimagining What We Measure in Atherosclerosis—a “Phenotype Stack”
MacRae, C. A., & Califf, R. M. (2020) · Circulation Research · doi:10.1161/circresaha.120.315941 · Cited by 10
Ferreira, J. P., Cleland, J. G. F., Lam, C. S. P., Anker, S. D., Mehra, M. R., van Veldhuisen, D. J., Byra, W. M., Police, D. A. L., Greenberg, B., & Zannad, F. M. (2021) · Clinical Research in Cardiology · doi:10.1007/s00392-021-01891-2 · Cited by 10
Zhang, H., Zhu, L., Nathan, V., Kuang, J., Kim, J., Gao, J. A., & Olgin, J. E. (2021) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3463503 · Cited by 14
Digital health—high tech or high touch?
Gangl, C., & Krychtiuk, K. A. (2023) · Wiener Medizinische Wochenschrift · doi:10.1007/s10354-022-00991-6 · Cited by 10
Rubio, L. F., Granero, C. L., Vidal-Pérez, R., Barrios, V., & Freixa‐Pamias, R. (2023) · Revista Española de Cardiología · doi:10.1016/j.recesp.2023.07.011 · Cited by 14
Approach to narrow complex tachycardia: non-invasive guide to interpretation and management
Shah, R. L., & Badhwar, N. (2020) · Heart · doi:10.1136/heartjnl-2019-315304 · Cited by 10
Forecast of paroxysmal atrial fibrillation using a deep neural network
Gilon, C., GREGOIRE, J.-M., & Bersini, H. (2020) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn48605.2020.9207227 · Cited by 11
Mueller, C., Schauerte, I., & Martin, S. (2021) · JMIR Research Protocols · doi:10.2196/21727 · Cited by 10
Wagle, A. A., Isakadze, N., Nasir, K., & Martin, S. S. (2021) · Current Atherosclerosis Reports · doi:10.1007/s11883-021-00916-5 · Cited by 12
The triple aim of clinical research
Dorsey, E. R., & Kieburtz, K. D. (2021) · Clinical Trials · doi:10.1177/17407745211001522 · Cited by 10
What will we ask to artificial intelligence for cardiovascular medicine in the next decade?
Gallone, G., BRUNO, F., D’ASCENZO, F., & FERRARI, G. M. D. (2021) · Minerva Cardiology and Angiology · doi:10.23736/s2724-5683.21.05753-7 · Cited by 10
Wearable photoplethysmography devices
Charlton, P. H., & Marozas, V. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-823374-0.00011-6 · Cited by 10
Implementation of a fully remote randomized clinical trial with cardiac monitoring
Mayfield, J. J., Chatterjee, N. A., Noseworthy, P. A., Poole, J. E., Ackerman, M. J., Stewart, J. C., KISSINGER, P. J., Dwyer, J., Hosek, S., Oyedele, T., et al. (2021) · Communications Medicine · doi:10.1038/s43856-021-00052-w · Cited by 10
Kesar, A., Baluch, A., Barber, O., Hoffmann, H., Jovanovic, M., Renz, D., Stopak, B. L., Wicks, P. J., & Gilbert, S. (2022) · PLoS ONE · doi:10.1371/journal.pone.0263940 · Cited by 11
The Chinese burden of atrial fibrillation review of atrial fibrillation studies in China
Song, J. (2022) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12957 · Cited by 9
A systematic review of deep learning methods for modeling electrocardiograms during sleep
Sun, C., Hong, S., Wang, J., Dong, X., Han, F., & Li, H. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac826e · Cited by 13
Reshaping care in the aftermath of the pandemic. Implications for cardiology health systems
Jordán‐Ríos, A., Nuzzi, V., Bromage, D. I., McDonagh, T. A., Sinagra, G., & Cannata, A. N. (2022) · European Journal of Internal Medicine · doi:10.1016/j.ejim.2022.11.029 · Cited by 8
Poorthuis, M. H. F., Sherliker, P., de Borst, G. J., Clack, R. M., Lewington, S., Clarke, R., Bulbulia, R. A., & Halliday, A. W. (2023) · International Journal of Cardiology · doi:10.1016/j.ijcard.2023.131262 · Cited by 10
The Medical Internet of Things: applications in respiratory medicine
Angelucci, A., & Aliverti, A. (2023) · European Respiratory Society eBooks · doi:10.1183/2312508x.10000423 · Cited by 11
Guo, Y., & Lip, G. Y. H. (2020) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2020.12 · Cited by 10
Photoplethysmography in Diverse Skin Tones: Evaluating Bias in Smartwatch Health Monitoring
Asif, S., AlSaafeen, A., Nadar, S., Nambiar, S., Dannawi, J., Korrapati, H., & Wilkhoo, H. S. (2025) · Cureus · doi:10.7759/cureus.94074 · Cited by 13
Halimi, F., Sabouret, P. F., Huberman, J.-P., Ouazana, L., Guedj, D., Djouadi, K., Dhanjal, T., Goette, A., Lafont, C., & Lellouche, N. (2022) · Clinical Research in Cardiology · doi:10.1007/s00392-022-02109-9 · Cited by 9
Assessing the current utilization status of wearable devices in clinical research
Miyakoshi, T., & Ito, Y. M. (2024) · Clinical Trials · doi:10.1177/17407745241230287 · Cited by 14
Fu, F., Zhong, D., Liu, J., Xu, T., Shen, Q., Wang, W., Zhu, S., & Li, J. (2024) · Bioengineering · doi:10.3390/bioengineering11030293 · Cited by 9
Substantiation and Effectiveness of Remote Monitoring System Based on IoMT Using Portable ECG Device
Lee, H. Y., Kim, Y.-J., Lee, K. H., Lee, J. H., Cho, S. P., Park, J. H., Park, I.-H., & Youk, H. (2024) · Bioengineering · doi:10.3390/bioengineering11080836 · Cited by 9
Self-citationFrancisco, A., Pascoal, C., Lamborne, P., Morais, H., & Gonçalves, M. A. D. A. (2025) · Cureus · doi:10.7759/cureus.77404 · Cited by 12
Willemstein, N., Sridar, S., van der Kooij, H., & Sadeghi, A. (2025) · Wearable Technologies · doi:10.1017/wtc.2024.23 · Cited by 9
Zhang, L., Li, B., & Wu, L. (2025) · Annals of Medicine · doi:10.1080/07853890.2025.2478474 · Cited by 9
Marzoog, B. A., Chomakhidze, P. S., Gognieva, D. G., Silantyev, A., Suvorov, А. Y., Abdullaev, M., Mozzhukhina, N., Filippova, D. A., Kostin, S. V., Kolpashnikova, M., et al. (2025) · World Journal of Cardiology · doi:10.4330/wjc.v17.i4.104396 · Cited by 9
Akyuz, E., Aslan, F., & Eyigurbuz, T. (2025) · Epilepsia · doi:10.1111/epi.18502 · Cited by 7
Teleanu, I. C., Bejan, G. C., Poiană, I. R., Mîrșu-Păun, A., Dumitrescu, S. I., & Stănescu, A. M. A. (2025) · Vascular Health and Risk Management · doi:10.2147/vhrm.s521952 · Cited by 9
Li, B., Huang, Y., Mao, W., Liu, J., & Ma, Q. (2025) · Journal of Multidisciplinary Healthcare · doi:10.2147/jmdh.s548258 · Cited by 10
Consumer wearable technologies to identify and monitor exercise-related arrhythmias in athletes
Sanchis‐Gomar, F., Lavie, C. J., & Perez, M. V. (2020) · Current Opinion in Cardiology · doi:10.1097/hco.0000000000000817 · Cited by 9
Self-citationNew Technologies for Detection and Management of Atrial Fibrillation
Hamad, A. K. (2021) · Journal of the Saudi Heart Association · doi:10.37616/2212-5043.1256 · Cited by 10
Heart Watch Study: protocol for a pragmatic randomised controlled trial
Dhruva, S. S., Shah, N. D., Vemulapalli, S., Deshmukh, A. J., Beatty, A. L., Gamble, G. M., Freeman, J. V., Hummel, J. P., Piccini, J. P., Akar, J. G., et al. (2021) · BMJ Open · doi:10.1136/bmjopen-2021-054550 · Cited by 9
Self-citationMehrang, S., Tadi, M. J., Knuutila, T., Jaakkola, J., Jaakkola, S., Kiviniemi, T., Vasankari, T., Airaksinen, J. K. E., Koivisto, T., & Pänkäälä, M. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac66ba · Cited by 10
A Watch-Type Electrocardiography Is a Reliable Tool for Detecting Paroxysmal Cardiac Arrhythmias
Kim, Y. G., Choi, J., Jung, J. S., Min, K., Choi, Y. Y., Shim, J., Son, H. S., & Kim, Y. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11123333 · Cited by 9
Psychosocial measures in relation to smartwatch alerts for atrial fibrillation detection
Filippaios, A., Tran, K., Mehawej, J., Ding, E., Paul, T. J., Lessard, D., BARTON, B. A., Lin, H., Naeem, S. S., Otabil, E. M., et al. (2022) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2022.07.069 · Cited by 9
Remote Monitoring in Cardiovascular Diseases
Pelter, M. N., Quer, G., & Pandit, J. A. (2023) · Current Cardiovascular Risk Reports · doi:10.1007/s12170-023-00726-1 · Cited by 10
Patient-centric care: Unveiling the potential of wearable electronics in clinical practice
Zhao, P., Xu, J., & Han, M. (2024) · Wearable electronics. · doi:10.1016/j.wees.2024.07.001 · Cited by 9
Over- and undersensing—pitfalls of arrhythmia detection with implantable devices and wearables
Sperzel, J., Hamm, C. W., & Hain, A. (2020) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-020-00710-x · Cited by 9
Lansky, A. J., Shah, T., Wijns, W. C., Stefanini, G. G., Farb, A. A., Kaplan, A. V., Xu, B., Pietras, C. G., Velazquez, E. J., Serruys, P. W. J. C., et al. (2020) · EuroIntervention · doi:10.4244/eijv16i10a147 · Cited by 9
Freyer, L., von Stülpnagel, L., Spielbichler, P., Sappler, N., Wenner, F. N., Schreinlechner, M., Krasniqi, A., Behroz, A., Eiffener, E., Zens, M., et al. (2021) · American Heart Journal · doi:10.1016/j.ahj.2021.06.008 · Cited by 11
Roten, L., Goulouti, E., Lam, A., Elchinova, E., Nozica, N., Spirito, A., Wittmer, S., Branca, M., Servatius, H., Noti, F., et al. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10214871 · Cited by 9
Global Aging and Cancer: Advancing Care Through Innovation
Extermann, M., Hernández‐Favela, C. G., Soto‐Pérez‐de‐Celis, E., & Kanesvaran, R. (2022) · American Society of Clinical Oncology Educational Book · doi:10.1200/edbk_359154 · Cited by 9
Jung, S., Lee, H. A., Kang, I. S., Shin, S. H., Chang, Y., Shin, D. W., Park, M., Kim, Y. D., Nam, H. S., Heo, J. H., et al. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.837958 · Cited by 9
Self-citationMinielly, N., Hrincu, V. M., & Illes, J. (2020) · Developments in neuroethics and bioethics · doi:10.1016/bs.dnb.2020.03.010 · Cited by 9
Chocron, A., Efraim, R., Mandel, F., Rueschman, M., Palmius, N., Penzel, T., Elbaz, M., & Behar, J. A. (2020) · Physiological Measurement · doi:10.1088/1361-6579/abb8bf · Cited by 9
Shaughnessy, A. F., Slawson, D. C., & Duggan, A. P. (2021) · The Journal of the American Board of Family Medicine · doi:10.3122/jabfm.2021.02.200194 · Cited by 9
Wearable devices: monitoring the future?
Ioannidis, D. C., Kapasouri, E. M., & Vassiliou, V. S. (2019) · Oxford Medical Case Reports · doi:10.1093/omcr/omz143 · Cited by 9
Never Let a Crisis Go to Waste
Kumar, A., Patel, D. R., Nissen, S. E., & Desai, M. Y. (2020) · JACC Case Reports · doi:10.1016/j.jaccas.2020.05.014 · Cited by 9
Self-citationTelemonitoring of Real-World Health Data in Cardiology: A Systematic ReviewPreprint
Kinast, B., Lutz, M., & Schreiweis, B. (2021) · Preprints.org · doi:10.20944/preprints202107.0702.v1 · Cited by 9
Wearable Devices and Psychological Wellbeing—Are We Overthinking It?
Cheung, C. C., & Saad, M. (2024) · Journal of the American Heart Association · doi:10.1161/jaha.124.035962 · Cited by 9
Anaesthetic considerations in pregnant patients with cardiac arrhythmia
Bhatia, K., D'Souza, R. D., Malhamé, I., & Thorne, S. (2023) · BJA Education · doi:10.1016/j.bjae.2023.01.008 · Cited by 10
Atlas, S. J., Ashburner, J. M., Chang, Y., Borowsky, L. H., Ellinor, P. T., McManus, D. D., Lubitz, S. A., & Singer, D. E. (2023) · BMC Family Practice · doi:10.1186/s12875-023-02087-5 · Cited by 8
Ming, A., Alhajjar, A., Walter, I., Piehler, C., Hoetzsch, J., Leuckert, M., Clemens, V., Petrow, A., Siddiquee, I. M., Scurt, F. G., et al. (2023) · Deutsches Ärzteblatt international · doi:10.3238/arztebl.m2023.0229 · Cited by 11
Mathieu, A. J. W., Serna‐Pascual, M., Charlton, P. H., Volovaya, M., Venton, J., Aston, P. J., Nandi, M., & Alastruey, J. (2024) · JRSM Cardiovascular Disease · doi:10.1177/20480040231225384 · Cited by 13
Andersen, M. Ø., & Carlsen, J. (2024) · Contemporary Clinical Trials · doi:10.1016/j.cct.2024.107548 · Cited by 8
Wearable technology in vascular surgery: Current applications and future perspectives
Bartos, O., & Trenner, M. (2024) · Seminars in Vascular Surgery · doi:10.1053/j.semvascsurg.2024.08.004 · Cited by 8
Angelaki, E., Barmparis, G. D., Fragkiadakis, K., Maragkoudakis, S., Zacharis, E. A., Plevritaki, A., Kampanieris, E., Kalomoirakis, P., Kassotakis, S., KOCHIADAKIS, G. E., et al. (2024) · Journal of Human Hypertension · doi:10.1038/s41371-024-00969-4 · Cited by 9
From Wristbands to Implants: The Transformative Role of Wearables in Heart Failure Care
Gregório, C., Agostinho, J. R., Rigueira, J., Santos, R., Pinto, F. J., & Brito, D. A. (2024) · Healthcare · doi:10.3390/healthcare12242572 · Cited by 11
Sleep as a window of cardiometabolic health: The potential of digital sleep and circadian biomarkers
van den Brink, W. J., Oosterman, J. E., Smid, D. J., de Vries, H., Atsma, D. E., Overeem, S., & Wopereis, S. (2025) · Digital Health · doi:10.1177/20552076241288724 · Cited by 8
DGK-Positionspapier zum Umgang mit Device-detektiertem Vorhofflimmern (DDAF)
Tönnis, T., Birkemeyer, R., Duncker, D., Eckardt, L., Gröschel, K., Linz, D., Meyer, C. G., Richter, S., Straube, F., Sultan, A., et al. (2025) · Die Kardiologie · doi:10.1007/s12181-025-00750-y · Cited by 8
Lueken, M., Mettner, J., Spicher, N., Gramlich, M., Marx, N., Leonhardt, S. K., & Zink, M. D. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3579621 · Cited by 8
Kurpas, D., Petrazzuoli, F., Shantsila, E., Antonopoulou, M., Christodorescu, R., Korzh, O., Kümler, T., Kyriakou, M., Neubeck, L., Papakonstantinou, P. Ε., et al. (2025) · European Journal of Preventive Cardiology · doi:10.1093/eurjpc/zwaf384 · Cited by 8
Akram, M. S., Varma, B. S., Javed, A., Harkin, J., & Finlay, D. (2025) · Journal of Systems Architecture · doi:10.1016/j.sysarc.2025.103587 · Cited by 12
Flores-Castañeda, R. O., Olaya-Cotera, S., & Iparraguirre-Villanueva, O. (2025) · Neural Computing and Applications · doi:10.1007/s00521-025-11605-8 · Cited by 12
Artificial intelligence identifies individuals with prediabetes using single-lead electrocardiograms
Koga, D., Kaneda, R., Komiya, C., Ohno, S., Takeuchi, A., Hara, K., Horino, M., Aoki, J., Okazaki, R., Ishii, R., et al. (2025) · Cardiovascular Diabetology · doi:10.1186/s12933-025-02982-4 · Cited by 8
Exploring an AI-First Healthcare System
Gates, A., Ali, A., Conard, S. E., & Dunn, P. J. (2026) · Bioengineering · doi:10.3390/bioengineering13010112 · Cited by 9
Wearable Sensors for Health Monitoring
Abreu, C., Bédard, C., Lourme, J.-C., & Piro, B. (2026) · Biosensors · doi:10.3390/bios16020093 · Cited by 12
Challenges in the remote monitoring of cardiac implantable electronic devices in 2021
Malanchini, G., Ferrari, G., Leidi, C., Ferrari, P., Senni, M., & Filippo, P. D. (2021) · Kardiologia Polska · doi:10.33963/kp.15899 · Cited by 8
Combining digital data and artificial intelligence for cardiovascular health
Soto, J. T., Hershman, S. G., & Ashley, E. A. (2021) · Cardiovascular Research · doi:10.1093/cvr/cvab211 · Cited by 8
Itzhak, S. B., Ricon, S. S., Biton, S. B., Behar, J. A., & Sobel, J. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac6561 · Cited by 10
van Hulst, M., Tieleman, R. G., Zwart, L. A. R., Pomp, M., Jacobs, M. S., Meeder, J. G., van Ofwegen-Hanekamp, C. E. E., Hollander, M., Smits, P., & Hemels, M. E. W. (2022) · European Heart Journal - Quality of Care and Clinical Outcomes · doi:10.1093/ehjqcco/qcac042 · Cited by 9
Stroke Prevention in Atrial Fibrillation
Gao, X., & PASSMAN, R. S. (2022) · Current Cardiology Reports · doi:10.1007/s11886-022-01787-1 · Cited by 8
Persons, A. K., Middleton, C., Parker, E., Ball, J. E., Burch, R. F. V., Macias, D. M., Simpson, C. L., & Elder, S. H. (2023) · ECS Sensors Plus · doi:10.1149/2754-2726/acb21e · Cited by 8
Remote Monitoring of Cardiac Implantable Electronic Devices: What is the Evidence?
Reinhardt, A., & Ventura, R. (2023) · Current Heart Failure Reports · doi:10.1007/s11897-023-00586-1 · Cited by 8
A smart devices based secondary prevention program for cerebrovascular disease patients
Motolese, F., Capone, F., Magliozzi, A., Vico, C., Iaccarino, G., Falato, E., Pilato, F., & Lazzaro, V. D. (2023) · Frontiers in Neurology · doi:10.3389/fneur.2023.1176744 · Cited by 9
Artificial intelligence and wearable technology
Gaffar, S., & Gearhart, A. S. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-90534-3.00056-1 · Cited by 8
Neri, L., Gallelli, I., Dall’Olio, M., Lago, J., Borghi, C., Diemberger, I., & Corazza, I. (2024) · Bioengineering · doi:10.3390/bioengineering11030222 · Cited by 8
Dutch-GERAF investigators, Zwart, L. A. R., Spruit, J. R., Hemels, M. E. W., de Groot, J. R., Pisters, R., Riezebos, R. K., & Jansen, R. W. M. M. (2024) · Netherlands Heart Journal · doi:10.1007/s12471-024-01868-6 · Cited by 8
Atrial Fibrillation Burden on a 14-Day ECG Monitor
Singer, D. E., Atlas, S. J., Go, A. S., Lubitz, S. A., McManus, D. D., Dolor, R. J., Chatterjee, R., Rothberg, M. B., Rushlow, D. R., Crosson, L. A., et al. (2024) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2024.08.010 · Cited by 8
Connected health: Ventricular tachycardia detection with Apple Watch–A case report
Guarnieri, G., Mapelli, M., Moltrasio, M., Agostoni, P., & Tondo, C. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e40595 · Cited by 8
Huynh, P. P., Shan, R., Osuji, N., Ding, J., Isakadze, N., Marvel, F. A., Sharma, G. V., & Martin, S. S. (2020) · JMIR Cardio · doi:10.2196/18050 · Cited by 8
Kotalczyk, A., Gue, Y. X., Potpara, T., & Lip, G. Y. H. (2021) · Expert Opinion on Pharmacotherapy · doi:10.1080/14656566.2021.1879050 · Cited by 8
Evaluating Polygenic Risk Scores in “Lone” Atrial Fibrillation
Lazarte, J., Dron, J. S., McIntyre, A. D., Skanes, A. C., Gula, L. J., TANG, A. S. L., Tadros, R., Laksman, Z., Hegele, R. A., & Roberts, J. D. (2021) · CJC Open · doi:10.1016/j.cjco.2021.02.001 · Cited by 8
Keating, B. J., Mukhtar, E. H., Elftmann, E., Eweje, F. R., Gao, H., Ibrahim, L. I., Kathawate, R. G., Lee, A., Li, E. H., Moore, K., et al. (2021) · Transplant International · doi:10.1111/tri.13860 · Cited by 8
The Role of Artificial Intelligence in Arrhythmia Monitoring
Siontis, K. C., & Friedman, P. A. (2021) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2021.04.011 · Cited by 8
Metadata
- Authors
- Perez, M. V., Mahaffey, K. W., Hedlin, H., Rumsfeld, J. S., Garcia, A., Ferris, T., Balasubramanian, V., Russo, A. M., Rajmane, A., Cheung, L., Hung, G., Lee, J., Kowey, P., Talati, N., Nag, D., Gummidipundi, S. E., Beatty, A., Hills, M. T., Desai, S., Granger, C. B., Desai, M., & Turakhia, M. P.
- Affiliations
- Stanford Medicine (US)
- From the Division of Cardiovascular Medicine (M.V.P.), Stanford Center for Clinical Research (K.W.M., A.R., N.T.), the Quantitative Sciences Unit (H.H., A.G., V.B., J.L., S.E.G., M.D.), Information Resources and Technology (T.F., G.H.), Department of Medicine (S.D.), and the Center for Digital Health (M.P.T.), Stanford University, Stanford, Apple, Cupertino (L.C., D.N., A.B., S.D.), and the Veterans Affairs Palo Alto Health Care System, Palo Alto (M.P.T.) — all in California; the University of...
- Cooper Medical School of Rowan University (US)
- Lankenau Heart Institute (US)
- Duke University (US)
- VA Palo Alto Health Care System (US)
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2019-11-14
- Volume
- 381
- Issue
- 20
- Pages
- 1909-1917
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- PMC
- PMC8112605
- OpenAlex
- W2987985090
- Cited by
- 1,917
- References
- 12
- Citations by year
- 2026: 263 · 2025: 300 · 2024: 259 · 2023: 276 · 2022: 271 · 2021: 304 · 2020: 228 · 2019: 12
- FWCI
- 71.74
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- Stanford University
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Keywords
- atrial fibrillation, smartwatches, wearable devices, optical pulse detection, positive predictive value, ECG patch, telemedicine, mobile application, health care utilization, older adults, adverse events, participant satisfaction, participant burden, participant retention, participant recruitment
- MeSH terms
- Wearable Electronic Devices, Adult, Aged, Algorithms, Atrial Fibrillation, Confidentiality, Electrocardiography, Female, Humans, Male, Middle Aged, Predictive Value of Tests, Prospective Studies, Telemedicine, Mobile Applications
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review