Cited by 241Non-Invasive Vital Sign MonitoringHeart Rate Variability and Autonomic ControlPhysical Activity and Health

Guidelines for wrist-worn consumer wearable assessment of heart rate in biobehavioral research

Open access
Nelson, Benjamin W., Low, Carissa A., Jacobson, Nicholas, Areán, Patricia, Torous, John, Allen, Nicholas B.·2020·npj Digital Medicine

Abstract

Researchers have increasingly begun to use consumer wearables or wrist-worn smartwatches and fitness monitors for measurement of cardiovascular psychophysiological processes related to mental and physical health outcomes. These devices have strong appeal because they allow for continuous, scalable, unobtrusive, and ecologically valid data collection of cardiac activity in “big data” studies. However, replicability and reproducibility may be hampered moving forward due to the lack of standardization of data collection and processing procedures, and inconsistent reporting of technological factors (e.g., device type, firmware versions, and sampling rate), biobehavioral variables (e.g., body mass index, wrist dominance and circumference), and participant demographic characteristics, such as skin tone, that may influence heart rate measurement. These limitations introduce unnecessary noise into measurement, which can cloud interpretation and generalizability of findings. This paper provides a brief overview of research using commercial wearable devices to measure heart rate, reviews literature on device accuracy, and outlines the challenges that non-standardized reporting pose for the field. We also discuss study design, technological, biobehavioral, and demographic factors that can impact the accuracy of the passive sensing of heart rate measurements, and provide guidelines and corresponding checklist handouts for future study data collection and design, data cleaning and processing, analysis, and reporting that may help ameliorate some of these barriers and inconsistencies in the literature.

AI snapshot

Written from the paper’s full text.

TL;DR

This paper reviews the use of wrist-worn consumer wearables for heart rate measurement in biobehavioral research and argues that lack of standardized data collection, processing, and reporting threatens reproducibility and generalizability. It provides two reporting checklists covering study design, technological factors, participant characteristics, data cleaning, analysis, and transparency.

Key findings

  • Wearables using photoplethysmography (PPG) can provide acceptable heart rate accuracy for research, especially with aggregated data and outlier removal, but not for medical settings; devices slightly underestimate absolute HR versus ECG by −0.9 to −7.2 bpm, with Apple Watch at −1.3 bpm and Fitbit at −9.3 bpm.
  • Error ranges were 1.20–6.70% for Apple Watch models and 2.38–21.36% for Fitbit models; any single real-time HR observation can deviate substantially from ECG, even when summary statistics are accurate.
  • Between 2008 and 2018, there was a 580% increase in articles containing “wearable” and “heart rate.”
  • Accuracy is influenced by motion artifacts and activity, with absolute error during activity reported as 30% higher than at rest; darker skin tone and tattoos can reduce green-light PPG accuracy, and larger wrist circumference or higher BMI are associated with reduced accuracy in some but not all studies.

Methods

  • Narrative review and guideline paper; no primary data collection, systematic review, or meta-analysis is described.
  • Synthesizes literature on commercial wrist-worn wearable HR accuracy and factors affecting measurement, focusing mainly on Apple Watch and Fitbit while noting Garmin, Samsung, and Microsoft.
  • Proposes two checklists (Tables 2 and 3) for descriptive reporting and potential covariates, and recommends open science practices such as preregistration, open code, and open data.

Limitations

  • The paper states that the field lacks metadata standards and consistent reporting of device type, firmware, sampling rate, biobehavioral variables, and demographic characteristics, which introduces noise and limits reproducibility and generalizability.
  • It states that accuracy evidence is mixed for activity intensity, skin tone, BMI, and wrist circumference, and that proprietary algorithms and lack of raw data prevent standardized processing.
  • Evident from the text: this is a narrative review without a systematic search or meta-analysis, and the proposed checklists are not empirically validated in the paper.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1038/s41746-020-0297-4

Cites

79 of 79 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Claims the paper makes

0 of 99 cited sources checked · 0 supported · 0 flagged

  • Interpretationreasoning

    These limitations introduce unnecessary noise into measurement, which can cloud interpretation and generalizability of findings.

    “These limitations introduce unnecessary noise into measurement, which can cloud interpretation and generalizability of findings.”
    Quote in the paperNot a substantial claim
  • Interpretationcitation

    Cardiac activity may be a biological factor linking mood and anxiety disorders with cardiovascular and metabolic risk and mortality.

    “Cardiac activity therefore may be a biological factor that serves as a mechanism linking mood and anxiety disorders with cardiovascular and metabolic risk and mortality14,15.”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [14] Kiecolt-Glaser, J. K. & Wilson, S. J. Psychiatric disorders, morbidity, and mortality: tracing mechanistic pathways to accelerated aging. Psychosom. Med. 78, 772–775 (2016). source

      Not checked in the free run.

    • cites [15] Nemeroff, C. B. & Goldschmidt-Clermont, P. J. Heartache and heartbreak–the link between depression and cardiovascular disease. Nat. Rev. Cardiol. 9, 526–539 (2012). source

      Not checked in the free run.

  • Premisecitation

    The law of initial values holds that an initial value has a large impact on the strength and direction of a response, such that a higher pre-stimulus level leads to a smaller post-stimulus response.

    “The law of initial values gives further insight into this issue by highlighting that an initial value has a large impact on the strength and direction of a response, such that a higher pre-stimulus level will lead to a smaller post-stimulus response or, in other words, a smaller response when there is a greater initial value19–21.”
    Quote in the paperSubstantial claim0 of 3 sources checked
    • cites [19] Geenen, R. & Vijver, F. J. R. A simple test of the law of initial values. Psychophysiology 30, 525–530 (1993). source

      Not checked in the free run.

    • cites [20] Pattyn, N., Migeotte, P.-F., Neyt, X., den Nest, A. & van, Cluydts, R. Comparing real-life and laboratory-induced stress reactivity on cardio-respiratory parameters: differentiation of a tonic and a phasic component. Physiol. Behav. 101, 218–223 (2010). source

      Not checked in the free run.

    • cites [21] Wilder, J. Basimetric approach (law of initial value) to biological rhythms. Ann. N. Y. Acad. Sci. 98, 1211–1220 (1962). source

      Not checked in the free run.

  • Interpretationreasoning

    Photoplethysmography devices allow for in vivo examinations of the roles that resting heart rate and heart rate dynamics have in medical and psychiatric disorders in real-world settings.

    “Overall, PPG devices allow for in vivo examinations of the roles that resting HR and HR dynamics (e.g., reactivity and recovery) have in medical and psychiatric disorders in real-world settings.”
    Quote in the paperSubstantial claim
  • Premisecitation

    Current research into heart rate accuracy of wrist-worn wearable devices compares wearable photoplethysmography measurement with a reference method such as electrocardiogram to determine whether measurements between devices are outside clinically important limits of agreement.

    “Current research into the HR accuracy of wrist-worn wearable devices attempt to compare the measurement between wearable PPG and a reference method, such as an ECG, in order to determine whether or not measurements between the devices are outside of clinically important limits of agreement, so that devices can supplement, eventually replace, or be used interchangeably37,38.”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [37] Bland, J. M. & Altman, D. G. Measuring agreement in method comparison studies. Stat. Meth. Med. Res 8, 135–160 (1999). source

      Not checked in the free run.

    • cites [38] Nelson, B. W. & Allen, N. B. Accuracy of consumer wearable heart rate measurement during an ecologically valid 24-hour period: intraindividual validation study. JMIR mHealth uHealth 7, e10828 (2019). source

      Not checked in the free run.

  • Classified as probably not a substantial claim. 33
  • May combine two claims. 38
  • Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).

    Findingnone given

    Between 2008 and 2018 there was a 580% increase in total articles published that contained "wearable" and "heart rate".

    “Between 2008 and 2018 there was a 580% increase in total articles published that contained “wearable” and “heart rate”, indicating that this is a burgeoning area of research that may benefit from standardization of procedures to increase generalizability and clinical utility of research findings.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S4 (based).

    Premisenone given

    Researchers have increasingly used consumer wearables or wrist-worn smartwatches and fitness monitors for measurement of cardiovascular psychophysiological processes related to mental and physical health outcomes.

    “Researchers have increasingly begun to use consumer wearables or wrist-worn smartwatches and fitness monitors for measurement of cardiovascular psychophysiological processes related to mental and physical health outcomes.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S4 (based).

    Premisenone given

    Consumer wearables allow continuous, scalable, unobtrusive, and ecologically valid data collection of cardiac activity in big data studies.

    “These devices have strong appeal because they allow for continuous, scalable, unobtrusive, and ecologically valid data collection of cardiac activity in “big data” studies.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisecitation

    Heart rate is predominantly influenced by coordination of the sympathetic and parasympathetic branches of the autonomic nervous system, which can be modified by biopsychosocial factors including physical and relational stress, diet, physical fitness, medication use, and substance use.

    “HR is predominantly influenced by the coordination of the sympathetic and parasympathetic branches of the autonomic nervous system, which can be modified by biopsychosocial factors including physical and relational stress, diet, physical fitness, medication use, and substance use1; thus, offering a direct and quantifiable connection to the stress diathesis model of health.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [1] Cacioppo J. T., Tassinary L. G., & Berntson G. G. (eds) Handbook of Psychophysiology 4th edn. (Cambridge University Press, 2017). source

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Collection of heart rate data in laboratory or medical environments lacks temporal resolution within and across days as heart rate is usually collected during a short recording within a single day, which has precluded research from comprehensively investigating the transition from acute to chronic stress.

    “Second, collection of HR data in these environments lacks temporal resolution within and across days as HR is usually collected during a short recording within a single day, which has precluded research from comprehensively investigating the transition from acute to chronic stress22.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [22] Rohleder, N. Stress and inflammation—the need to address the gap in the transition between acute and chronic stress effects. Psychoneuroendocrinology https://doi.org/10.1016/j.psyneuen.2019.02.021 (2019). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S4 (based).

    Premisenone given

    Heart rate research has been constrained by inability to collect temporally detailed and longitudinal heart rate measurements both within and across time.

    “(2) inability to collect temporally detailed and longitudinal HR measurements both within and across time (e.g., hours, days, weeks, months)”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisecitation

    Researchers are increasingly using consumer wearables or wrist-worn smartwatches and fitness monitors for digital measurement of cardiovascular health and psychophysiological stress because these devices allow continuous, scalable, unobtrusive big data collection of cardiac activity in real-world conditions with large samples.

    “Researchers are increasingly using consumer wearables or wrist-worn smartwatches and fitness monitors for the digital measurement of cardiovascular health and psychophysiological stress as these devices allow for continuous, scalable, and unobtrusive, “big data” collection of overall cardiac activity in real-world conditions with large samples25–30.”
    Quote in the paperSubstantial claim0 of 6 sources checked
    • cites [25] Bradshaw, B. et al. Influenza surveillance using wearable mobile health devices. In International Society for Disease Surveillance Conference 2019 (2019).

      Not checked in the free run.

    • cites [26] Natarajan, A., Pantelopoulos, A., Emir-Farinas, H. & Natarajan, P. Heart rate variability with photoplethysmography in 8 million individuals: results and scaling relations with age, gender, and time of day. Preprint at https://www.biorxiv.org/content/10.1101/772285v1 (2019). source

      Not checked in the free run.

    • cites [27] Perez, M. V. et al. Large-scale assessment of a smartwatch to identify atrial fibrillation. N. Engl. J. Med. 381, 1909–1917 (2019). source

      Not checked in the free run.

    • cites [28] Sim, I. Mobile devices and health. N. Engl. J. Med. 381, 956–968 (2019). source

      Not checked in the free run.

    • cites [29] Tison, G. H. et al. Passive detection of atrial fibrillation using a commercially available smartwatch. JAMA Cardiol. 3, 409 (2018). source

      Not checked in the free run.

    • cites [30] Tison, G. H. et al. Cardiovascular Risk Stratification Using Off-the-Shelf Wearables and a Multi-Task Deep Learning Algorithm. In:; 2018. source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).

    Premisenone given

    Some recent wrist-worn wearable devices, such as the Apple Watch Series 4 and 5, have allowed for collection of heart rate via electrical impulses on par with a single-lead electrode.

    “The latter of these two is the predominant method for data collected with wrist-worn wearable devices, although some more recent wrist-worn wearable devices, such as the Apple Watch Series 4 and 5, have allowed for the collection of HR via electrical impulses on par with a single-lead electrode.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationreasoning

    Research has historically been limited to collecting data from medical patients and research participants in novel settings that might not generalize to everyday lives, creating potential for inaccurate baselines and inaccurate measurement of heart rate dynamics.

    “In other words, research has been historically limited to collecting data from medical patients and research participants in novel settings that might not generalize to their everyday lives, which creates the potential for inaccurate baselines and therefore inaccurate measurement of HR dynamics (i.e., reactivity/recovery).”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S4 (based).

    Premisenone given

    Heart rate research has been constrained by prohibitive financial cost of devices for everyday use.

    “(3) prohibitive financial cost of devices for everyday use.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisecitation

    Photoplethysmography can be used to index heart rate variability, blood pressure, oxygen saturation, and cardiac output, but as of yet has not been widely rolled out in consumer-use devices.

    “Furthermore, PPG can be used to index heart rate variability (HRV), blood pressure, oxygen saturation, and cardiac output24, but as of yet have not be widely rolled out in consumer-use devices and therefore data collection other than HR will not be discussed further.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [24] Elgendi, M. On the analysis of fingertip photoplethysmogram signals. Curr. Cardiol. Rev. 8, 14–25 (2012). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S4 (based). May combine two claims.

    Premisenone given

    Until recently, quantification and measurement of heart rate has been relegated to medical and research settings, largely precluding observation of heart rate during daily life and limiting generalizability of findings to real-world living conditions.

    “Until recently, the quantification and measurement of HR has been relegated to medical and research settings, which has largely precluded the observation of HR during patient and participant daily life, thereby limiting the generalizability of findings to real-world living conditions.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisecitation

    Red LEDs are more commonly used in medical settings, are not absorbed as well by the skin allowing light to transmit deeper and detect multiple biological measures, but have a lower signal-to-noise ratio and are more susceptible to motion artifacts.

    “In contrast, red LEDs, which are more commonly used in medical settings, are not absorbed as well by the skin allowing the light to transmit deeper and allowing for detection of multiple biological measures, but it has a lower signal-to-noise ratio and is more susceptible to motion artifacts23.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [23] Mahloko, L. & Adebesin, F. in Responsible Design, Implementation and Use of Information and Communication Technology. Lecture Notes in Computer Science (eds Hattingh, M., et al.) Vol. 12067, 96–107 (Springer International Publishing, Cham, 2020). source

      Not checked in the free run.

  • May combine two claims.

    Premisenone given

    Green LED light is a shorter wavelength and has good signal-to-noise ratio and resistance to motion artifacts, but is limited by the amount of light that can pass through tissue, especially darker skin tones.

    “For example, green LED light is a shorter wave-length and has been shown to be convenient, because it has good signal-to-noise ratio and is resistant to motion artifacts, but is limited by the amount of light that can pass through tissue, especially darker skin tones.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationreasoning

    This novel electrocardiogram technology only allows for discrete, rather than continuous, collection of data, which precludes temporally detailed longitudinal ECG collection at this time.

    “Therefore, this novel electrocardiogram (ECG) technology only allows for the discrete, rather than continuous, collection of data, which precludes the ability for temporally detailed longitudinal ECG collection at this time.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationreasoning

    Heart rate may be a transdiagnostic biomarker with clinical utility for psychology, psychiatry, and medicine to improve nosology and increase identification of those at risk for onset of psychiatric and physical health disorders.

    “In other words, HR may be a transdiagnostic biomarker with clinical utility for psychology, psychiatry, and medicine to improve nosology and increase identification of those at risk for the onset of psychiatric and physical health disorders.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S4 (based).

    Premisenone given

    Heart rate research has been constrained by lack of ecological validity.

    “The foundation of HR research has, until recently, been largely constrained due to (1) lack of ecological validity (i.e., the degree to which a laboratory or medical environment represents actual real-world conditions)”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisereasoning

    Wrist-worn wearables provide an opportunity to examine heart rate in real-world environments, across longer periods of time, and with high resolution at low cost, by using photoplethysmography.

    “Currently, wrist-worn wearables provide an opportunity to examine HR in real-world environments, across longer periods of time, and with high resolution at a low cost, by using an optical sensor (photoplethysmography; PPG), that allows these devices to collect volumetric changes in blood profusion (i.e., pulse rate) that can serve as a surrogate for HR”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Interpretationcitation

    The reproducibility and replicability crisis is important for digital health and mHealth research, including wrist-worn heart rate accuracy and studies utilizing wearable heart rate data, because this new field allows for large data samples with various sensors that increase the ease for p-hacking.

    “Recent information on the reproducibility and replicability crisis has swept the sciences and as such these issues are very important for digital health and mHealth research, which includes wrist-worn HR accuracy and any studies that utilize wearable HR data, as this new field will allow for large data samples31 with various sensors that will increase the ease for p-hacking.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [31] Stupple, A., Singerman, D., & Celi, L. A. The reproducibility crisis in the age of digital medicine. npjDigital Med. 2, https://doi.org/10.1038/s41746-019-0079-z (2019). source

      Not checked in the free run.

  • Classified as probably not a substantial claim.

    Interpretationcitation

    Questions remain as to the accuracy and validity of data collected from wearables.

    “yet questions remain as to the accuracy and validity of data collected from wearables35,36.”
    Quote in the paperSubstantial claim0 of 2 sources checked
    • cites [35] Evenson, K. R., Goto, M. M., & Furberg, R. D. Systematic review of the validity and reliability of consumer-wearable activity trackers. Int. J. Behav. Nutr. Phys. Activity. 12, https://doi.org/10.1186/s12966-015-0314-1 (2015). source

      Not checked in the free run.

    • cites [36] Peake, J. M., Kerr, G., & Sullivan, J. P. A critical review of consumer wearables, mobile applications, and equipment for providing biofeedback, monitoring stress, and sleep in physically active populations. Front. Physiol. 9, https://doi.org/10.3389/fphys.2018.00743 (2018). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Some studies have used the gold-standard reference method of electrocardiogram, which directly measures heart rate via electrical impulses from the heart and is used for clinical accuracy.

    “Although some studies have attempted to address wearable HR accuracy using the gold-standard reference method of ECG, which directly measures HR via electrical impulses from the heart and is used for clinical accuracy38–44”
    Quote in the paperNot a substantial claim0 of 7 sources checked
    • cites [38] Nelson, B. W. & Allen, N. B. Accuracy of consumer wearable heart rate measurement during an ecologically valid 24-hour period: intraindividual validation study. JMIR mHealth uHealth 7, e10828 (2019). source

      Not checked in the free run.

    • cites [39] Boudreaux, B. D. et al. Validity of wearable activity monitors during cycling and resistance exercise. Med. Sci. Sports Exerc. 50, 624–633 (2018). source

      Not checked in the free run.

    • cites [40] de Zambotti, M. et al. Measures of sleep and cardiac functioning during sleep using a multi-sensory commercially-available wristband in adolescents. Physiol. Behav. 158, 143–149 (2016). source

      Not checked in the free run.

    • cites [41] Kroll, R. R., Boyd, J. G. & Maslove, D. M. Accuracy of a wrist-worn wearable device for monitoring heart rates in hospital inpatients: a prospective observational study. J. Med. Internet Res. 18, e253 (2016). source

      Not checked in the free run.

    • cites [42] Shcherbina, A. et al. Accuracy in wrist-worn, sensor-based measurements of heart rate and energy expenditure in a diverse cohort. J. Personalized Med. 7, 3 (2017). source

      Not checked in the free run.

    • cites [43] Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. Accuracy of heart rate watches: implications for weight management. PLoS ONE 11, https://doi.org/10.1371/journal.pone.0154420 (2016). source

      Not checked in the free run.

    • cites [44] Wang, R. et al. Accuracy of wrist-worn heart rate monitors. JAMA Cardiol. 2, 104–106 (2017). source

      Not checked in the free run.

  • May combine two claims.

    Interpretationcitation

    While overall summary statistics after outlier detection and data cleaning may be very accurate for research purposes, any single observation in real-time may have a large degree of error, which could be significant for moment-to-moment observations in medical settings.

    “This finding indicated that while overall, summary statistics after outlier detection and data cleaning may be very accurate for research purposes, any single observation in real-time may have a large degree of error, which could be significant for moment-to-moment observations in medical settings.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Some wearable devices, such as the Apple Watch 4 and 5, have gained FDA 510(k) class II clearance for the ECG feature and ability to detect arrhythmias.

    “Furthermore, some wearable devices, such as the Apple Watch 4 and 5, have gained FDA 510(k) class II clearance for the ECG feature and ability to detect arrhythmias49”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [49] FDA. Electrocardiographsoftware for Over-the-Counter Use. https://www.accessdata.fda.gov/cdrh_docs/pdf18/DEN180044.pdf (FDA, 2018).

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Consumer wearables such as the Apple Watch and Fitbit are more accurate than research-grade wearables, which are much more expensive yet provide the benefit of raw data.

    “Furthermore, recent research has indicated that consumer wearables, such as the Apple Watch and Fitbit are more accurate than research-grade wearables, which are much more expensive yet provide the benefit of raw data50.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [50] Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P. Investigating sources of inaccuracy in wearable optical heart rate sensors. npj Digital Med. 3, https://doi.org/10.1038/s41746-020-0226-6 (2020). source

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    In a study comparing ambulatory electrocardiogram, Apple Watch 3, and Fitbit Charge 2 within individuals across 24 h, devices slightly underestimated heart rate when values were aggregated within and across different daily activities, indicating high heart rate accuracy.

    “For example, researchers compared the accuracy of ambulatory ECG, Apple Watch 3, and Fitbit Charge 2 data within an individual across 24 h and found that while devices slightly underestimated HR when values were aggregated within and across different daily activities, which indicated high HR accuracy”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [38] Nelson, B. W. & Allen, N. B. Accuracy of consumer wearable heart rate measurement during an ecologically valid 24-hour period: intraindividual validation study. JMIR mHealth uHealth 7, e10828 (2019). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Many researchers have begun to push for increased focus on reproducible and open practices in science.

    “Therefore, many researchers have begun to push for increased focus on reproducible and open practices in science31,53–55.”
    Quote in the paperNot a substantial claim0 of 4 sources checked
    • cites [31] Stupple, A., Singerman, D., & Celi, L. A. The reproducibility crisis in the age of digital medicine. npjDigital Med. 2, https://doi.org/10.1038/s41746-019-0079-z (2019). source

      Not checked in the free run.

    • cites [53] Bavel, J. J. V., Mende-siedlecki, P., Brady, W. J. & Reinero, D. A. Contextual sensitivity in scientific reproducibility. Proc. Natl Acad. Sci. USA 113, 6454–6459 (2016). source

      Not checked in the free run.

    • cites [54] Munafò, M. R. et al. A manifesto for reproducible science. Nat. Hum. Behav. 1, https://doi.org/10.1038/s41562-016-0021 (2017). source

      Not checked in the free run.

    • cites [55] Tackett, J. L., Brandes, C. M., King, K. M. & Markon, K. E. Psychology’s replication crisis and clinical psychological science. Annu. Rev. Clin. Psychol. 15, 579–604 (2019). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S1 (asserted). May combine two claims.

    Interpretationcitation

    Wearables detect heart rate with acceptable accuracy in both laboratory and real-world settings for research, but importantly not medical settings.

    “These findings have led some researchers to conclude that wearables detect HR with acceptable accuracy in both laboratory and real-world settings for research, but importantly not medical settings38,42 as more research needs to be done.”
    Quote in the paperNot a substantial claim0 of 2 sources checked
    • cites [38] Nelson, B. W. & Allen, N. B. Accuracy of consumer wearable heart rate measurement during an ecologically valid 24-hour period: intraindividual validation study. JMIR mHealth uHealth 7, e10828 (2019). source

      Not checked in the free run.

    • cites [42] Shcherbina, A. et al. Accuracy in wrist-worn, sensor-based measurements of heart rate and energy expenditure in a diverse cohort. J. Personalized Med. 7, 3 (2017). source

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Apple Watch has lower mean difference standard deviation and higher agreement with electrocardiogram than Fitbit devices.

    “lower mean difference standard deviation43, and higher agreement with ECG than Fitbit devices39,44.”
    Quote in the paperSubstantial claim0 of 3 sources checked
    • cites [39] Boudreaux, B. D. et al. Validity of wearable activity monitors during cycling and resistance exercise. Med. Sci. Sports Exerc. 50, 624–633 (2018). source

      Not checked in the free run.

    • cites [43] Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. Accuracy of heart rate watches: implications for weight management. PLoS ONE 11, https://doi.org/10.1371/journal.pone.0154420 (2016). source

      Not checked in the free run.

    • cites [44] Wang, R. et al. Accuracy of wrist-worn heart rate monitors. JAMA Cardiol. 2, 104–106 (2017). source

      Not checked in the free run.

  • May combine two claims.

    Premisereasoning

    Hardware differences between devices determine heart rate measurement second to second, with large implications for overall interpretability of the data, such that sampling rate introduces researcher degrees of freedom for calculating bpm.

    “Hardware differences between devices determine HR measurement second to second, which has large implications on overall interpretability of the data, such that sampling rate can introduces researcher degrees of freedom for calculating bpm.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S2 (checkable).

    Interpretationreasoning

    For long-term field studies, information about participant adherence and wear-time should be considered and reported since these issues can affect data quality.

    “For long-term field studies, information about participant adherence and wear-time should be considered and reported since these issues can affect data quality.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    Outliers in linear models may strongly impact linear estimators, and some studies may therefore adopt a modeling strategy wherein values are winsorized.

    “For example, outliers in linear models may strongly impact linear estimators, and some studies may therefore adopt a modeling strategy wherein values are winsorized (e.g., extreme values can be truncated at the 2.5th and 97.5th quantiles56).”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [56] Hastings, C. Jr., Mosteller, F., Tukey, J. W. & Winsor, C. P. Low moments for small samples: a comparative study of order statistics. Ann. Math. Stat. 18, 413–426 (1947). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S4 (based). May combine two claims.

    Premisenone given

    Fitbit logs heart rate data at 1 s intervals during exercise tracking and 5 s intervals at other times, whereas the Apple Watch samples heart rate data every 10 min, except during workouts, which are continuous.

    “For example, Fitbit logs HR data at 1 s intervals during exercise tracking and 5 s intervals at other times, whereas the Apple Watch samples HR data every 10 min, except during workouts, which are continuous.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S2 (checkable).

    Interpretationreasoning

    Data cleaning methods should be customized to the device being used and the models being adopted, rather than adopting a universal pre-processing pipeline, due to device-specific differences and study research questions.

    “There is a strong need to customize the methods of data cleaning to the device being used and the models being adopted, rather than adopting a universal pre-processing pipeline due to device-specific differences and based on the study research questions.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S2 (checkable), S4 (based). May combine two claims.

    Interpretationnone given

    There are many researcher degrees of freedom in decisions related to study protocol design and data collection, cleaning, and processing that are important to note as standardizing this process may help ameliorate some barriers and inconsistencies in the literature.

    “There are many researcher degrees of freedom when it comes to decisions related to study protocol design and data collection, cleaning, and processing that are important to note as standardizing this process may help ameliorate some barriers and inconsistencies in the literature.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisecitation

    Listwise deletion is known to bias estimation and adversely impact the standard error of point estimates across modeling strategies.

    “The practice of completely removing persons from studies due to proportions of missing data (i.e. listwise deletion) is known to bias estimation and adversely impact the standard error of point estimates across modeling strategies58.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [58] Graham, J. W. Missing data analysis: making it work in the real world. Annu. Rev. Psychol. 60, 549–576 (2009). source

      Not checked in the free run.

  • Classified as probably not a substantial claim.

    Interpretationcitation

    If a study is interested in heart rate arrhythmias using wearable assessments, extreme values may be of vital interest and should not be removed or altered.

    “However, if a study were interested in HR arrythmias using wearable assessments (such as atrial fibrillation), then these extreme values may be of vital interest and should not be removed or altered27.”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [27] Perez, M. V. et al. Large-scale assessment of a smartwatch to identify atrial fibrillation. N. Engl. J. Med. 381, 1909–1917 (2019). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S4 (based).

    Interpretationnone given

    Methods researchers select to clean and process raw data prior to analyses can affect results and conclusions.

    “In addition, the methods researchers select to clean and process raw data prior to analyses can also affect results and conclusions and should be reported in detail.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisecitation

    Larger wrist circumference has been shown to be associated with reduced heart rate accuracy, although these outcomes have not been found in all studies.

    “Larger wrist circumference has been shown to be associated with reduced HR accuracy42, although these outcomes have not been found in all studies44,46.”
    Quote in the paperNot a substantial claim0 of 3 sources checked
    • cites [42] Shcherbina, A. et al. Accuracy in wrist-worn, sensor-based measurements of heart rate and energy expenditure in a diverse cohort. J. Personalized Med. 7, 3 (2017). source

      Not checked in the free run.

    • cites [44] Wang, R. et al. Accuracy of wrist-worn heart rate monitors. JAMA Cardiol. 2, 104–106 (2017). source

      Not checked in the free run.

    • cites [46] Gillinov, S. et al. Variable accuracy of wearable heart rate monitors during aerobic exercise. Med. Sci. Sports Exerc. 49, 1697–1703 (2017). source

      Not checked in the free run.

  • Classified as probably not a substantial claim. May combine two claims.

    Interpretationreasoning

    Some devices report missing heart rate data with zero values; these values should be removed and filled in with missing data rather than winsorized, which would otherwise substantially bias parameter estimates unless the degree of missing heart rate points was trivial.

    “Moreover, for some, but not all devices will report missing HR data with zero values and these values should be removed and filled in with missing data rather than winsorized (which would otherwise substantially bias parameter estimates unless the degree of missing HR points was trivial).”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.

    Premisenone given

    One issue reported by multiple users on the online Fitbit Community Forum is occasional logging of heart rate values (often higher and more variable than typical, e.g., 100-150 bpm) when the devices are not being worn, suggesting that supplemental non-wear-time diaries may be required for some devices or protocols.

    “One issue reported by multiple users on the online Fitbit Community Forum is occasional logging of HR values (often higher and more variable than typical, e.g., 100–150 bpm) when the devices are not being worn, suggesting that supplemental non-wear-time diaries may be required for some devices or protocols.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisereasoning

    Some devices, such as the Apple Watch, can take multiple heart rate measurements within a minute, allowing researchers to use various calculations such as the mean or median within this minute to calculate bpm, which may alter wearable data values.

    “Relatedly, some devices, such as the Apple Watch can take multiple HR measurements within a minute allowing researchers to use various calculations, such as the mean or median within this minute to calculate bpm, which may alter wearable data values.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Absolute error during activity is 30% higher than at rest.

    “some research showing that absolute error during activity is 30% higher than rest50”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [50] Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P. Investigating sources of inaccuracy in wearable optical heart rate sensors. npj Digital Med. 3, https://doi.org/10.1038/s41746-020-0226-6 (2020). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based). May combine two claims.

    Interpretationreasoning

    Low power likely will not be an issue for mHealth research as large sample sizes will be relatively easy to collect even in samples with low base rates in the population.

    “the last of which likely will not be an issue for mHealth research as large samples sizes will be relatively easy to collect even in samples with low base rates in the population.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationreasoning

    Failure to report or control for participant race and ethnicity in wrist-worn wearable heart rate studies undermines the ability to examine potentially important group differences in health outcomes and decreases the ability of results to generalize to large segments of the population.

    “Currently, the vast majority of wrist-worn wearable studies incorporating HR measurements do not report or control for participant race and ethnicity, which undermines the ability to look at potentially important group differences in health outcomes and therefore decreases the ability of results to generalize to large segments of the population.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: The vast majority of wrist-worn wearable studies incorporating heart rate measurements do not report or control for participant race and ethnicity.
  • May combine two claims.

    Premisecitation

    Darker skin tone (and tattoos) has been found to be associated with reduced wrist-worn heart rate accuracy as they absorb more green light, yet this is not found in all studies.

    “Evidence is starting to accumulate on the importance of skin tone when it comes to accuracy and generalizability of wrist-worn wearable studies with darker skin tone (and tattoos) being found to be associated with reduced wrist-worn HR accuracy as they absorb more green light67, yet this is not found in all studies43,50.”
    Quote in the paperSubstantial claim0 of 3 sources checked
    • cites [67] Weiler, D. T., Villajuan, S. O., Edkins, L., Cleary, S. & Saleem, J. J. Wearable heart rate monitor technology accuracy in research: a comparative study between PPG and ECG technology. Proc. Hum. Factors Ergonomics Soc. Annu. Meet. 61, 1292–1296 (2017). source

      Not checked in the free run.

    • cites [43] Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. Accuracy of heart rate watches: implications for weight management. PLoS ONE 11, https://doi.org/10.1371/journal.pone.0154420 (2016). source

      Not checked in the free run.

    • cites [50] Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P. Investigating sources of inaccuracy in wearable optical heart rate sensors. npj Digital Med. 3, https://doi.org/10.1038/s41746-020-0226-6 (2020). source

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Wearables that use red light will likely be more effective on darker skin tones because red light is not absorbed by melanin, which may allow for more accurate heart rate measurements.

    “wearables that use red light will likely be more effective on darker skin tones as it is not absorbed by melanin, which may allow for more accurate HR measurements23.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [23] Mahloko, L. & Adebesin, F. in Responsible Design, Implementation and Use of Information and Communication Technology. Lecture Notes in Computer Science (eds Hattingh, M., et al.) Vol. 12067, 96–107 (Springer International Publishing, Cham, 2020). source

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Higher body mass index, which likely covaries with larger wrist circumference, has been shown to be associated with reduced heart rate accuracy, although these outcomes have not been found in all studies.

    “Higher body mass index, which likely covaries with larger wrist circumference as described above, has been shown to be associated with reduced HR accuracy42,62, although again these outcomes have not been found in all studies44,46.”
    Quote in the paperNot a substantial claim0 of 4 sources checked
    • cites [42] Shcherbina, A. et al. Accuracy in wrist-worn, sensor-based measurements of heart rate and energy expenditure in a diverse cohort. J. Personalized Med. 7, 3 (2017). source

      Not checked in the free run.

    • cites [62] Menghini, L. et al. Stressing the accuracy: wrist-worn wearable sensor validation over different conditions. Psychophysiology. 56, https://doi.org/10.1111/psyp.13441 (2019). source

      Not checked in the free run.

    • cites [44] Wang, R. et al. Accuracy of wrist-worn heart rate monitors. JAMA Cardiol. 2, 104–106 (2017). source

      Not checked in the free run.

    • cites [46] Gillinov, S. et al. Variable accuracy of wearable heart rate monitors during aerobic exercise. Med. Sci. Sports Exerc. 49, 1697–1703 (2017). source

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Hair follicle density and sweat can influence device measurement.

    “some research indicates that hair follicle density and sweat can influence device measurement69.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [69] Cosoli, G., Spinsante, S. & Scalise, L. Wrist-worn and chest-strap wearable devices: systematic review on accuracy and metrological characteristics. Measurement 159, 107789 (2020). source

      Not checked in the free run.

  • May combine two claims.

    Premisecitation

    Historically, science and medicine have paid less attention to recruiting minority groups, which has resulted in blunted health gains in these populations.

    “The importance of this point cannot be overstated as historically, science and medicine have paid less attention to recruiting minority groups68, which has resulted in blunted health gains in these populations”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [68] Hall, G. C. N., Yip, T. & Zárate, M. A. On becoming multicultural in a monocultural research world: a conceptual approach to studying ethnocultural diversity. Am. Psychol. 71, 40–51 (2016). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing), S4 (based).

    Interpretationreasoning

    Wearables that use red light will likely be more effective on darker skin tones as it is not absorbed by melanin.

    “Furthermore, wearables that use red light will likely be more effective on darker skin tones as it is not absorbed by melanin, which may allow for more”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationreasoning

    Consumer wearable devices can be used to supplement medical-grade devices and continuously collect heart rate data on research subjects when risk for acute cardiac events is not of immediate concern.

    “these devices can be used to supplement medical-grade devices and continuously collect HR data on research subjects when risk for acute cardiac events is not of immediate concern.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    A second study found that accuracy of heart rate measurement was highest during running.

    “a second study found that the accuracy of HR measurement was highest during running51”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [51] Xie, J. et al. Evaluating the validity of current mainstream wearable devices in fitness tracking under various physical activities: comparative study. JMIR Mhealth Uhealth 6, e94 (2018). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S2 (checkable).

    Interpretationreasoning

    The recent introduction of consumer wearables has the potential to improve the study of cardiovascular health in medicine and psychophysiological stress in psychiatry and psychology.

    “This has the potential to improve the study of cardiovascular health in medicine and psychophysiological stress in psychiatry and psychology.”
    Quote in the paperNot a substantial claim
    • Rests on an assumption: Consumer wearables allow continuous, scalable, unobtrusive, big data collection of cardiac activity in real-world conditions with large samples.
  • Probably not a substantial claim: may not pass S2 (checkable).

    Interpretationreasoning

    Using consumer wearables to supplement medical-grade devices has the potential to advance research into cardiovascular health and psychophysiological stress in order to better understand how heart rate influences overall physical and psychological health.

    “This has the potential to advance research into cardiovascular health and psychophysiological stress in order to better understand how HR influences overall physical and psychological health.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Premisecitation

    PPG green light is less susceptible to motion artifacts, whereas PPG red light is more susceptible to motion artifacts.

    “one strength of PPG green light is that it is less susceptible to motion artifacts, whereas PPG red light is more susceptible to motion artifacts”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [23] Mahloko, L. & Adebesin, F. in Responsible Design, Implementation and Use of Information and Communication Technology. Lecture Notes in Computer Science (eds Hattingh, M., et al.) Vol. 12067, 96–107 (Springer International Publishing, Cham, 2020). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    Across four consumer wearables and two research-grade devices, all were reasonably accurate during rest or during prolonged elevated heart rate, and differences in accuracy tended to arise during changes in activity.

    “Other research found that across four consumer wearables and two research-grade devices all were “reasonably accurate” during rest or during prolonged HR that was elevated and that differences in accuracy tended to arise during changes in activity50.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [50] Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P. Investigating sources of inaccuracy in wearable optical heart rate sensors. npj Digital Med. 3, https://doi.org/10.1038/s41746-020-0226-6 (2020). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Some researchers have worked with industry partners to derive measurements of heart rate variability.

    “although some researchers have worked with industry partners to derive measurements of HRV26.”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [26] Natarajan, A., Pantelopoulos, A., Emir-Farinas, H. & Natarajan, P. Heart rate variability with photoplethysmography in 8 million individuals: results and scaling relations with age, gender, and time of day. Preprint at https://www.biorxiv.org/content/10.1101/772285v1 (2019). source

      Not checked in the free run.

  • May combine two claims.

    Interpretationcitation

    Activity intensity may be less important to device accuracy than the degree of erratic wrist movements and corresponding position of the wearable device during an activity, which cause motion artifacts and may or may not co-occur with more vigorous physical activity.

    “Therefore, it is possible that activity intensity may be less important to device accuracy than the degree of erratic wrist movements and corresponding position of the wearable device during an activity74, which cause motion artifacts and may or may not co-occur with”
    Quote in the paperSubstantial claim0 of 1 sources checked
    • cites [74] Parak, J. & Korhonen, I. Evaluation of wearable consumer heart rate monitors based on photopletysmography. Conf. Proc. IEEE Eng. Med. Biol. Soc. 3670-3673 2014, 3670–3673 (2014).

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Some studies found that accuracy of heart rate measurement was comparable across resting baseline or vigorous activity.

    “some studies finding that accuracy of HR measurement was comparable across resting baseline or vigorous activity45”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [45] Dooley, E. E., Golaszewski, N. M. & Bartholomew, J. B. Estimating accuracy at exercise intensities: a comparative study of self-monitoring heart rate and physical activity wearable devices. JMIR mHealth uHealth 5, e34 (2017). source

      Not checked in the free run.

  • Probably not a substantial claim: may not pass S2 (checkable). May combine two claims.

    Interpretationreasoning

    Utilizing these guidelines and referencing them in methods sections has the potential to decrease non-standard reporting, increase reproducibility and replicability, and lead to greater generalizability of results, which may increase clinical utility.

    “Utilizing these guidelines and referencing them in methods sections has the potential to decrease non-standard reporting, increase reproducibility and replicability, while also leading to greater generalizability of results, which may increase the clinical utility of findings in this field.”
    Quote in the paperNot a substantial claim
60 of 60
  • The paper relies on this without support.

    There is currently a lack of transparency from manufacturers on underlying algorithms and raw data outputs are often not provided.

    “Unfortunately, there is currently a lack of transparency from manufacturers on underlying algorithms and raw data outputs are often times not provided, which prevents researchers from dealing with this issue and creating a standardized protocol for transforming raw data to HR.”
  • The paper relies on this without support.

    The vast majority of wrist-worn wearable studies incorporating heart rate measurements do not report or control for participant race and ethnicity.

    “Currently, the vast majority of wrist-worn wearable studies incorporating HR measurements do not report or control for participant race and ethnicity, which undermines the ability to look at potentially important group differences in health outcomes and therefore decreases the ability of results to generalize to large segments of the population.”
  • The paper relies on this without support.

    Various wearable devices and versions on the market may use different hardware, which may introduce differences in heart rate recordings.

    “there are currently various wearable devices and versions on the market that have the potential to use different hardware, which may introduce differences in HR recordings.”
  • The paper relies on this without support.

    Wearable algorithms may be altered with firmware updates.

    “These algorithms, while often simplistic, may be altered with firmware updates”
  • The paper relies on this without support.

    Most studies fail to report firmware information.

    “yet most studies fail to report firmware information.”
  • The paper relies on this without support.

    Consumer wearables allow continuous, scalable, unobtrusive, big data collection of cardiac activity in real-world conditions with large samples.

    “The recent introduction of consumer wearables or wrist-worn smartwatches and fitness monitors for the digital measurement of cardiovascular health and psychophysiological stress has allowed for the continuous, scalable, and unobtrusive, “big data” collection of overall cardiac activity in real-world conditions with large samples that allow for the collection of passive, large-scale, and ecolog”
  • The paper relies on this without support.

    PPG technology can be used to index blood pressure, oxygen saturation, and cardiac output.

    “It is important to note that PPG technology can be used to index blood pressure, oxygen saturation, and cardiac output, which will likely be slowly rolled out into wearable technology moving forward.”
  • The paper relies on this without support.

    PPG can index heart rate variability, which is derived from beat-to-beat interval calculations in the time-domain.

    “In addition, PPG can index HRV, which is derived from beat to beat intervals calculations in the time-domain, such as root mean squared of successive differences or the standard deviation of NN intervals, the latter of which is used in the Apple Watch, but only with sporadic recordings throughout the day.”
  • The paper relies on this without support.

    Many commercial wearables do not provide beat-to-beat interval data to users.

    “Currently, many commercial wearables do not provide beat to beat interval data to users”
  • The paper relies on this without support.

    Research is heavily context dependent.

    “We do this because research is heavily context dependent.”
10 of 10

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Algorithm developmental biases stem from selecting features, adjusting training data composition, and model calibrations.

    “The accuracy of heart rate measurements affects people with darker skin tones because of algorithm developmental biases that stem from selecting features and adjusting training data composition and model calibrations [23-26].”

    From Photoplethysmography in Diverse Skin Tones: Evaluating Bias in Smartwatch Health Monitoring (2025) · cites this paper as [23]

    The Biobehavioral and demographic data section reports that darker skin tone has been associated with reduced wrist-worn heart-rate accuracy, while noting that not all studies find this effect. It attributes the potential difference to absorption of green light; it does not identify feature selection, training-data composition, or model calibration as causes of algorithmic bias. No page number is provided in our copy. (LLM, conf=0.82)

    Experimental — accuracy not yet measured
  • Socioeconomic disparities in access to smartwatches may interact with skin-tone-related bias, raising additional equity concerns.

    “However, regional variations may exist, and socioeconomic disparities in access to these devices may further interact with skin-tone-related bias, raising additional equity concerns [17-23].”

    From Photoplethysmography in Diverse Skin Tones: Evaluating Bias in Smartwatch Health Monitoring (2025) · cites this paper as [23]

    The ‘Biobehavioral and demographic data’ section (page not available) discusses reduced heart-rate accuracy on darker skin tones in some studies and the resulting generalizability concerns. It does not address socioeconomic disparities in smartwatch access or whether those disparities interact with skin-tone-related bias. (LLM, conf=0.86)

    Experimental — accuracy not yet measured
  • More recent research has highlighted the potential presence of skin pigmentation biases in research-grade and consumer PPG-based wearable devices.

    “More recent research has also highlighted the potential presence of these biases in research-grade and consumer PPG-based wearable devices [4,27-29]”

    From Impact of skin pigmentation on pulse oximetry blood oxygenation and wearable pulse rate accuracy: systematic review and meta-analysis (2024) · cites this paper as [4]

    The Biobehavioral and demographic data section (page unavailable) reports that darker skin tone may reduce the accuracy of wrist-worn heart-rate wearables, though not all studies find this. The paper focuses on consumer PPG wearables; the passages do not establish the claim for research-grade devices. (LLM, conf=0.84)

    Experimental — accuracy not yet measured
  • There is a positive trend in wearable studies, underlining growing interest in wearables in health research.

    “Overall, we have identified a positive trend in wearable studies, underlining the growing interest in wearables in health research, in line with other reviews [3,224-226].”
  • The accuracy of PPG is impaired by factors that impede light transmission, such as elevated body mass index, tattoos, and higher hair follicle density.

    “While safe and inexpensive, the accuracy of PPG is impaired by factors that impede light transmission, such as elevated body mass index, tattoos, and higher hair follicle density [4].”

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Latvala, A. et al. Association of resting heart rate and blood pressure in late adolescence with subsequent mental disorders. JAMA Psychiatry 41, 89–104 (2016).

Cited by

Sorted by citations

Authors
Nelson, B. W., Low, C. A., Jacobson, N., Areán, P., Torous, J., & Allen, N. B.
Affiliations
  • University of Oregon (US)
  • University of Pittsburgh (US)
  • Dartmouth College (US)
  • University of Washington (US)
  • Beth Israel Deaconess Medical Center (US)
Corresponding author
Nelson, Benjamin W.
Venue
npj Digital Medicine
Published
2020-06-26
Volume
3
Issue
1
Pages
90-90
ISSN
2398-6352 (ISSN-L)
OpenAlex
W3037389028
Cited by
241
References
78
Citations by year
2026: 22 · 2025: 30 · 2024: 54 · 2023: 46 · 2022: 39 · 2021: 42 · 2020: 7
FWCI
2.80
Type
journal article
Language
en
Open access
Locations
  • npj Digital Medicine (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Minerva Access (University of Melbourne) (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
National Cancer Institute (K07CA204380)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
Keywords
heart rate measurement, consumer wearable devices, smartwatches, wrist-worn sensors, measurement accuracy, device standardization, reporting guidelines, skin tone, sampling frequency, reproducibility

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-09.

Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-09.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review