Open-source automated insulin delivery in type 1 diabetes
Open accessAbstract
BACKGROUND: Open-source automated insulin delivery (AID) systems are used by many patients with type 1 diabetes. Data are needed on the efficacy and safety of an open-source AID system. METHODS: In this multicenter, open-label, randomized, controlled trial, we assigned patients with type 1 diabetes in a 1:1 ratio to use an open-source AID system or a sensor-augmented insulin pump (control). The patients included both children (defined as 7 to 15 years of age) and adults (defined as 16 to 70 years of age). The AID system was a modified version of AndroidAPS 2.8 (with a standard OpenAPS 0.7.0 algorithm) paired with a preproduction DANA-i insulin pump and Dexcom G6 CGM, which has an Android smartphone application as the user interface. The primary outcome was the percentage of time in the target glucose range of 70 to 180 mg per deciliter (3.9 to 10.0 mmol per liter) between days 155 and 168 (the final 2 weeks of the trial). RESULTS: A total of 97 patients (48 children and 49 adults) underwent randomization (44 to open-source AID and 53 to the control group). At 24 weeks, the mean (±SD) time in the target range increased from 61.2±12.3% to 71.2±12.1% in the AID group and decreased from 57.7±14.3% to 54.5±16.0% in the control group (adjusted difference, 14 percentage points; 95% confidence interval, 9.2 to 18.8; P<0.001), with no treatment effect according to age (P = 0.56). Patients in the AID group spent 3 hours 21 minutes more in the target range per day than those in the control group. No severe hypoglycemia or diabetic ketoacidosis occurred in either group. Two patients in the AID group withdrew from the trial owing to connectivity issues. CONCLUSIONS: In children and adults with type 1 diabetes, the use of an open-source AID system resulted in a significantly higher percentage of time in the target glucose range than the use of a sensor-augmented insulin pump at 24 weeks. (Supported by the Health Research Council of New Zealand; Australian New Zealand Clinical Trials Registry number, ACTRN12620000034932.).
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The OpenAPS heuristic algorithm is supported by large real-world studies and a multicenter RCT.
“The OpenAPS heuristic algorithm (implemented on a system on a chip in OpenAPS, Android smartphones as An-droidAPS, and iPhone as iAPS/Trio) is supported by large real-world studies (256) and a multicenter RCT (257).”
From 7. Diabetes Technology: Standards of Care in Diabetes—2025 (2025) · cites this paper as [257]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069 · see citing works
Six-Month Randomized, Multicenter Trial of Closed-Loop Control in Type 1 Diabetes
Brown, S. A., Kovatchev, B. P., Raghinaru, D., Lum, J. W., Buckingham, B. A., Kudva, Y. C., Laffel, L. M., Levy, C. J., Pinsker, J. E., Wadwa, R. P., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1907863 · Cited by 1,030 · see citing works
Weisman, A., Bai, J.-W., Cardinez, M., Kramer, C. K., & Perkins, B. A. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(17)30167-5 · Cited by 463 · see citing works
A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes
Breton, M. D., Kanapka, L. G., Beck, R. W., Ekhlaspour, L., Forlenza, G. P., Cengiz, E., Schoelwer, M., Ruedy, K. J., Jost, E., Carria, L., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2004736 · Cited by 455 · see citing works
Brown, S. A., Forlenza, G. P., Bode, B. W., Pinsker, J. E., Levy, C. J., Criego, A. B., Hansen, D. W., Hirsch, I. B., Carlson, A. L., Bergenstal, R. M., et al. (2021) · Diabetes Care · doi:10.2337/dc21-0172 · Cited by 286 · see citing works
Collyns, O. J., Meier, R. A., Betts, Z. L., Chan, D. S. H., Frampton, C., Frewen, C. M., Hewapathirana, N. M., Jones, S. D., Roy, A., Grosman, B., et al. (2021) · Diabetes Care · doi:10.2337/dc20-2250 · Cited by 276 · see citing works
Self-citationReal-world use of open source artificial Pancreas systems
Lewis, D., Leibrand, S., & Community, #. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816665635 · Cited by 180 · see citing works
Self-citationLum, J. W., Bailey, R. J., Barnes-Lomen, V., Naranjo, D., Hood, K. K., Lal, R. A., Arbiter, B., Brown, A. S., DeSalvo, D. J., Pettus, J., et al. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0535 · Cited by 150 · see citing works
Abraham, M. B., Nicholas, J. A., Smith, G. J., Fairchild, J. M., King, B. R., Ambler, G. R., Cameron, F. J., Davis, E. A., Jones, T. W., & on behalf of the PLGM Study Group (2017) · Diabetes Care · doi:10.2337/dc17-1604 · Cited by 141 · see citing works
Braune, K., Lal, R. A., Petruželková, L., Scheiner, G., Winterdijk, P., Schmidt, S., Raimond, L., Hood, K. K., Riddell, M. C., Skinner, T. C., et al. (2022) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(21)00267-9 · Cited by 130 · see citing works
Dovč, K., Boughton, C. K., Tauschmann, M., Thabit, H., Bally, L., Allen, J. M., Acerini, C. L., Arnolds, S., de Beaufort, C. E., Bergenstal, R. M., et al. (2019) · Diabetes Care · doi:10.2337/dc18-2625 · Cited by 99 · see citing works
Predictors of Time-in-Range (70–180 mg/dL) Achieved Using a Closed-Loop Control System
Schoelwer, M. J., Kanapka, L. G., Wadwa, R. P., Breton, M. D., Ruedy, K. J., Ekhlaspour, L., Forlenza, G. P., Cobry, E. C., Messer, L. H., Cengiz, E., et al. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2020.0646 · Cited by 63 · see citing works
Knoll, C., Peacock, S., Wäldchen, M., Cooper, D., Aulakh, S. K., Raile, K., Hussain, S., & Braune, K. (2021) · Diabetic Medicine · doi:10.1111/dme.14741 · Cited by 58 · see citing works
Performance of an Artificial Pancreas System for Young Children with Type 1 Diabetes
DeBoer, M. D., Breton, M. D., WAKEMAN, C. A., Schertz, E. M., Emory, E. G., Robic, J. L., Kollar, L. L., Kovatchev, B. P., & Cherñavvsky, D. R. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0424 · Cited by 49 · see citing works
Do-It-Yourself Artificial Pancreas System and the OpenAPS Movement
Lewis, D. M. (2019) · Endocrinology and Metabolism Clinics of North America · doi:10.1016/j.ecl.2019.10.005 · Cited by 49 · see citing works
Self-citationMarshall, D. C., Holloway, M., Korer, M., Woodman, J., Brackenridge, A., & Hussain, S. (2019) · Diabetes Therapy · doi:10.1007/s13300-019-00679-y · Cited by 41 · see citing works
Asarani, N. A. M., Reynolds, A. N., Elbalshy, M. M., Burnside, M. J., de Bock, M. I., Lewis, D. M., & Wheeler, B. J. (2020) · Acta Diabetologica · doi:10.1007/s00592-020-01623-4 · Cited by 41 · see citing works
Self-citationJeyaventhan, R., Gallen, G., Choudhary, P., & Hussain, S. (2021) · Diabetes Obesity and Metabolism · doi:10.1111/dom.14439 · Cited by 36 · see citing works
Burnside, M. J., Lewis, D. M., Crocket, H. R., Wilson, R., Williman, J. A., Jefferies, C., Paul, R. G., Wheeler, B. J., & de Bock, M. I. (2020) · Journal of Diabetes & Metabolic Disorders · doi:10.1007/s40200-020-00547-8 · Cited by 36 · see citing works
Self-citationLearning challenges of healthcare professionals supporting open‐source automated insulin delivery
Crocket, H. R., Lewis, D. M., Burnside, M. J., et al. (2021) · Diabetic Medicine · doi:10.1111/dme.14750 · Cited by 13 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
9. Pharmacologic Approaches to Glycemic Treatment: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Bajaj, M., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s009 · Cited by 728 · see citing works
7. Diabetes Technology: Standards of Care in Diabetes—2025
American Diabetes Association Professional Practice Committee, ElSayed, N. A., McCoy, R. G., Aleppo, G., Balapattabi, K., Beverly, E. A., Briggs Early, K., Bruemmer, D., Echouffo-Tcheugui, J. B., Ekhlaspour, L., et al. (2025) · Diabetes Care · doi:10.2337/dc25-s007 · Cited by 348 · see citing works
7. Diabetes Technology: <i>Standards of Care in Diabetes—2024</i>
American Diabetes Association Professional Practice Committee, ElSayed, N. A., Aleppo, G., Bannuru, R. R., Bruemmer, D., Collins, B. S., Ekhlaspour, L., Hilliard, M. E., Johnson, E. L., Khunti, K., et al. (2024) · Diabetes Care · doi:10.2337/dc24-s007 · Cited by 281 · see citing works
Forlenza, G. P., DeSalvo, D. J., Aleppo, G., Wilmot, E. G., Berget, C., Huyett, L. M., Hadjiyianni, I., Méndez, J. J., Conroy, L. R., Ly, T. T., et al. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0578 · Cited by 99 · see citing works
Real-world evidence of automated insulin delivery system use
Considine, E. G., & Sherr, J. L. (2024) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2023.0442 · Cited by 59 · see citing works
Petruzelkova, L., Neuman, V., Plachy, L., Kozak, M., Obermannova, B., Kolouskova, S., Pruhova, S., & Sumnik, Z. (2023) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2022.0562 · Cited by 40 · see citing works
Halperin, I. J., Wicklow, B., Amed, S., Chambers, A., Courage, C., Cummings, E., Kirkland, P., MacKay, D., Nakhla, M., Punthakee, Z., et al. (2025) · Canadian Journal of Diabetes · doi:10.1016/j.jcjd.2025.01.001 · Cited by 22 · see citing works
The first regulatory clearance of an open-source automated insulin delivery algorithm
Braune, K., Hussain, S., & Lal, R. (2023) · Journal of Diabetes Science and Technology · doi:10.1177/19322968231164166 · Cited by 23 · see citing works
- Authors
- Burnside, M. J., Lewis, D. M., Crocket, H. R., Meier, R. A., Williman, J. A., Sanders, O. J., Jefferies, C. A., Faherty, A. M., Paul, R. G., Lever, C. S., Price, S. K. J., Frewen, C. M., Jones, S. D., Gunn, T. C., Lampey, C., Wheeler, B. J., & de Bock, M. I.
- Affiliations
- Waikato District Health Board (NZ)
- University of Auckland (NZ)
- Auckland District Health Board (NZ)
- Southern District Health Board (NZ)
- From the Departments of Pediatrics (M.J.B., R.A.M., O.J.S., M.I.B.) and Population Health (J.A.W.), University of Otago, and the Department of Pediatrics, Canterbury District Health Board (M.J.B., O.J.S., M.I.B.), Christchurch, Te Huataki Waiora School of Health, Sport and Human Performance, University of Waikato (H.R.C.), and Waikato Regional Diabetes Service, Waikato District Health Board (R.G.P., C.S.L., S.K.J.P.), Hamilton, the Department of Pediatric Endocrinology, Starship Children’s Health, Auckland District Health Board (C.A.J., A.M.F., C.L.), and the Liggins Institute, University of Auckland (C.A.J.), Auckland, the Department of Women’s and Children’s Health, Dunedin School of Medicine, University of Otago (C.M.F., S.D.J., B.J.W.), and the Pediatric Department, Southern District Health Board (B.J.W.), Dunedin, and Nightscout New Zealand, Hamilton (T.C.G.) — all in New Zealand; and OpenAPS, Seattle (D.M.L.).
- ORCID
- Venue
- New England Journal of Medicine
- Publisher
- Massachusetts Medical Society
- Published
- 2022-09-08
- Volume
- 387
- Issue
- 10
- Pages
- 869-881
- ISSN
- 0028-4793 (ISSN-L)
- 1533-4406
- OpenAlex
- W4294908094
- Cited by
- 183
- References
- 20
- Citations by year
- 2026: 34 · 2025: 42 · 2024: 49 · 2023: 48 · 2022: 10
- FWCI
- 27.59
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- New England Journal of Medicine (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Health Research Council of New Zealand (19/481)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
- Keywords
- type 1 diabetes, OpenAPS, sensor-augmented pump, continuous glucose monitoring, Dexcom G6, time in target glucose range, hypoglycemia, children and adults, artificial pancreas, treatment efficacy and safety, children and adolescents, adults
- MeSH terms
- Adolescent, Adult, Aged, Australia, Blood Glucose, Child, Diabetes Mellitus, Type 1, Humans, Hypoglycemic Agents, Infusion Pumps, Insulin, Middle Aged, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review