Semi‐Active versus Passive or Active Tuned Mass Dampers for Structural Control
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A semi‐active tuned mass damper (TMD) is proposed to control wind induced vibrations in tall buildings. The semi‐active TMD uses a small amount of external power to modulate the damping. The net result is the equivalent of a passive TMD with hydraulically controlled time‐varying characteristics. Simulation studies show the proposed system is superior to conventional passively controlled and comparable to actively controlled systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Structural Control Using Active Tuned Mass Dampers
Chang, J. C. H., & Soong, T. T. (1980) · Journal of the Engineering Mechanics Division · doi:10.1061/jmcea3.0002652 · Cited by 291
Pulse Control of Single-Degree-of-Freedom System
Udwadia, F. E., & Tabaie, S. (1981) · Journal of the Engineering Mechanics Division · doi:10.1061/jmcea3.0002787 · Cited by 31
Research works printed but not linked: 4
- Bryson A. E. and Ho Y. C. Applied Optimal Control John Wiley and Sons Inc. New York N.Y. 1975.
- Hrovat D. “A Bond Graph Modeling of Pneumatic Passive and Semiactive Vehicle Suspension ” presented at the International Symposium SIMULATION 80 at Interlaken Switzerland June 1980.
- Hrovat D., 1981, An Experimental Comparison Between Semi‐Active and Passive Suspensions for Air‐Cushion Vehicles, International Journal of Vehicle Design, 2, 308
- 10.1115/1.3426956 · doi:10.1115/1.3426956
Cited by
Semi-active control systems for seismic protection of structures: a state-of-the-art review
Symans, M. D., & Constantinou, M. C. (1999) · Engineering Structures · doi:10.1016/s0141-0296(97)00225-3 · Cited by 706
Controlling buildings: a new frontier in feedback
(1997) · IEEE Control Systems · doi:10.1109/37.642972 · Cited by 445
Passive, Adaptive and Active Tuned Vibration Absorbers—A Survey
Sun, J. Q., Jolly, M. R., & Norris, M. A. (1995) · Journal of Mechanical Design · doi:10.1115/1.2836462 · Cited by 320
Vibration suppression of structures using tuned mass damper technology: A state-of-the-art review
Yang, F., Sedaghati, R., & Esmailzadeh, E. (2022) · Journal of Vibration and Control · doi:10.1177/1077546320984305 · Cited by 306
A review of active structural control: challenges for engineering informatics
Korkmaz, S. (2011) · Computers & Structures · doi:10.1016/j.compstruc.2011.07.010 · Cited by 290
Nagarajaiah, S. (2009) · Structural Control and Health Monitoring · doi:10.1002/stc.349 · Cited by 256
Soong, T. T. (1988) · Engineering Structures · doi:10.1016/0141-0296(88)90033-8 · Cited by 226
Nagarajaiah, S., & Varadarajan, N. (2005) · Engineering Structures · doi:10.1016/j.engstruct.2004.10.015 · Cited by 212
“Semi-active TMD for structural control has been proposed by Hrovat et al., Abe and Igusa and Yalla et al. [ 6 ,1,24].”
BackgroundStructures with Semiactive Variable Stiffness Single/Multiple Tuned Mass Dampers
Nagarajaiah, S., & Sonmez, E. (2007) · Journal of Structural Engineering · doi:10.1061/(asce)0733-9445(2007)133:1(67 · Cited by 190
“STMDs have been investigated by Hrovat et al. 1983, Abe 1996, and Abe and Igusa 1996.”
MethodVaradarajan, N., & Nagarajaiah, S. (2004) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(2004)130:4(451 · Cited by 172
Effectiveness of semi-active tuned mass dampers under harmonic excitation
Pinkaew, T., & Fujino, Y. (2001) · Engineering Structures · doi:10.1016/s0141-0296(00)00091-2 · Cited by 166
Semi-active tuned liquid column dampers for vibration control of structures
Yalla, S. K., Kareem, A., & Kantor, J. C. (2001) · Engineering Structures · doi:10.1016/s0141-0296(01)00047-5 · Cited by 164
“[2] In other fields, such as automotive vibration control, considerable research has been done on semi-active systems [3,4].”
BackgroundPerformance of MRE-based Vibration Absorbers
Lerner, A. A., & Cunefare, K. A. (2008) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x07077850 · Cited by 159
“They have been shown to be useful in vibration damping applications with buildings while conserving power requirements (Hrovat et al., 1983).”
BackgroundApplication of Tuned Mass Dampers for Structural Vibration Control: A State-of-the-art Review
Rahimi, F., Aghayari, R., & Samali, B. (2020) · Civil Engineering Journal · doi:10.28991/cej-2020-03091571 · Cited by 138
“[89] studied the interests of using an STMD for the suppression of wind-induced vibration.”
BackgroundYang, D.-H., Shin, J.-H., Lee, H., Kim, S.-K., & Kwak, M. K. (2017) · Journal of Sound and Vibration · doi:10.1016/j.jsv.2016.12.036 · Cited by 107
Control of response of structures with passive and active tuned mass dampers
Rasouli, S. K., & Yahyai, M. (2002) · The Structural Design of Tall Buildings · doi:10.1002/tal.181 · Cited by 26
A Comparison between a New Semi-Active Tuned Mass Damper and an Active Tuned Mass Damper
Owji, H. R., Shirazi, A. H. N., & Sarvestani, H. H. (2011) · Procedia Engineering · doi:10.1016/j.proeng.2011.07.350 · Cited by 26
Control performance evaluation of semi-active tmd subjected to various types of loads
Kim, H.-S., Chang, C., & Kang, J.-W. (2015) · International Journal of Steel Structures · doi:10.1007/s13296-015-9006-6 · Cited by 16
A novel semi-active tuned mass damper with tunable stiffness
Zhang, L., Hong, L., Dhupia, J. S., Johnson, S., Qaiser, Z., & Zhou, Z. (2018) · 2018 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (AIM) · doi:10.1109/aim.2018.8452301 · Cited by 9
Structural Control: Past, Present, and Future
(1997) · doi:10.1061/(asce)0733-9399(1997)123:9(897
State of the Art of Structural Control
(2003) · doi:10.1061/(asce)0733-9445(2003)129:7(845
Metadata
- Authors
- Hrovat, D., Barak, P., & Rabins, M.
- Venue
- Journal of Engineering Mechanics
- Published
- 1983-08
- Volume
- 109
- Issue
- 3
- Pages
- 691-705
- ISSN
- 0733-9399 (ISSN-L)
- 1943-7889
- DOI
- 10.1061/(asce)0733-9399(1983)109:3(691
- OpenAlex
- W2082770127
- Cited by
- 291
- References
- 2
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.