The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Vibrations of free and surface-coupled atomic force microscope cantilevers: Theory and experiment
Abstract
With an optical interferometer, the free vibration spectra and the local vibration amplitude of four rectangular atomic force microscope cantilevers made of silicon have been examined experimentally in a spectral range of 100 kHz to 10 MHz. A good agreement with the flexural wave theory of elastic beams was found. Coupling to torsional vibrations was also observed. When the sensor tip of the cantilever is in contact with a sample surface the resonances are shifted in frequency and the vibration amplitudes along the cantilever change. A method is presented to calculate this frequency shift using a linear approximation for the tip–sample interaction forces, and the results are compared with the frequency shift calculated from the point-mass model. The measured resonance frequencies of a surface-coupled cantilever do not correspond as well to the theoretical ones as in the free case even if the elastic-beam model is used. The reason for the disagreement is found to be the geometry of the commercial cantilevers and the nonlinearity of the tip-sample interaction force.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Mathematica. A system for doing mathematics by computer
Wolfram, S. (1988) · Virtual Defense Library (Ministerio de Defensa) · Cited by 2,797
Calculation of thermal noise in atomic force microscopy
Butt, H. J., & Jaschke, M. (1995) · Nanotechnology · doi:10.1088/0957-4484/6/1/001 · Cited by 1,589
Harris, C. M., Crede, C. E., & Trent, H. M. (1962) · Physics Today · doi:10.1063/1.3058391 · Cited by 1,023
Method for the calibration of atomic force microscope cantilevers
Sader, J. E., Larson, I., Mulvaney, P., & White, L. R. (1995) · Review of Scientific Instruments · doi:10.1063/1.1145439 · Cited by 1,000
(1996) · Handbook of Microscopy · doi:10.1002/9783527620524.ch13 · Cited by 726
Using force modulation to image surface elasticities with the atomic force microscope
Maivald, P., Butt, H. J., Gould, S. A. C., Prater, C. B., Drake, B., Gurley, J. A., Elings, V. B., & Hansma, P. K. (1991) · Nanotechnology · doi:10.1088/0957-4484/2/2/004 · Cited by 525
Lateral, normal, and longitudinal spring constants of atomic force microscopy cantilevers
Neumeister, J. M., & Ducker, W. A. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144646 · Cited by 334
Cited by
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
AFM-IR: Technology and Applications in Nanoscale Infrared Spectroscopy and Chemical Imaging
Dazzi, A., & Prater, C. B. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00448 · Cited by 1,082
The emergence of multifrequency force microscopy
Garcia, R., & Herruzo, E. T. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.38 · Cited by 577
Charge‐Induced Disorder Controls the Thermal Conductivity of Entropy‐Stabilized Oxides
Braun, J. L., Rost, C. M., Lim, M., Giri, A., Olson, D. H., Kotsonis, G. N., Stan, G., Brenner, D. W., Maria, J., & Hopkins, P. E. (2018) · Advanced Materials · doi:10.1002/adma.201805004 · Cited by 509
Towards the design of high-performance plant fibre composites
Bourmaud, A., Beaugrand, J., Shah, D. U., Placet, V., & Baley, C. (2018) · Progress in Materials Science · doi:10.1016/j.pmatsci.2018.05.005 · Cited by 492
Metadata
- Authors
- Rabe, U., Janser, K., & Arnold, W.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 1996-09-01
- Volume
- 67
- Issue
- 9
- Pages
- 3281-3293
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W1981999046
- Cited by
- 683
- References
- 8
- FWCI
- 7.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.