The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Attonewton force detection using ultrathin silicon cantilevers
Abstract
A measured force resolution of 5.6×10−18 N/Hz at 4.8 K in vacuum using a single-crystal silicon cantilever only 600 Å thick is demonstrated. The spring constant of this cantilever was 6.5×10−6 N/m, or more than 1000 times smaller than that of typical atomic force microscope cantilevers. The cantilever fabrication includes the integration of in-line tips so that the cantilever can be oriented perpendicular to a sample surface. This orientation helps suppress cantilever snap-in so that high force sensitivity can be realized for tip-sample distances less than 100 Å.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Improved fiber-optic interferometer for atomic force microscopy
Rugar, D., Mamin, H. J., & Guethner, P. (1989) · Applied Physics Letters · doi:10.1063/1.101987 · Cited by 629
Self-citationObservation of a chemical reaction using a micromechanical sensor
Gimzewski, J. K., Gerber, C., Meyer, E., & Schlittler, R. R. (1994) · Chemical Physics Letters · doi:10.1016/0009-2614(93)e1419-h · Cited by 469
Magnetic resonance force microscopy
Sidles, J. A., Garbini, J. L., Bruland, K. J., Rugar, D., Züger, O., Hoen, S., & Yannoni, C. S. (1995) · Reviews of Modern Physics · doi:10.1103/revmodphys.67.249 · Cited by 466
Self-citationNoninductive detection of single-proton magnetic resonance
Sidles, J. A. (1991) · Applied Physics Letters · doi:10.1063/1.104757 · Cited by 267
Active microlevers as miniature torque magnetometers
Rossel, C., Bauer, P., Zech, D., Hofer, J. A., Willemin, M., & Keller, H. (1996) · Journal of Applied Physics · doi:10.1063/1.362550 · Cited by 146
Sidles, J. A. (1992) · Physical Review Letters · doi:10.1103/physrevlett.68.1124 · Cited by 139
Three-dimensional imaging with a nuclear magnetic resonance force microscope
Züǵer, O., Hoen, S., Yannoni, C. S., et al. (1996) · Journal of Applied Physics · doi:10.1063/1.361089 · Cited by 90
Low-temperature magnetic resonance force detection
Wago, K., Züǵer, O., Kendrick, R. D., Yannoni, C. S., & Rugar, D. (1996) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.588513 · Cited by 58
Self-citationSub-surface imaging with the magnetic resonance force microscope
Hammel, P. C., Zhang, Z., Moore, G. J., et al. (1995) · Journal of Low Temperature Physics · doi:10.1007/bf00754562 · Cited by 34
Cited by
Single spin detection by magnetic resonance force microscopy
Rugar, D., Budakian, R., Mamin, H. J., & Chui, B. W. (2004) · Nature · doi:10.1038/nature02658 · Cited by 1,630
Self-citationEkinci, K. L., & Roukes, M. L. (2005) · Review of Scientific Instruments · doi:10.1063/1.1927327 · Cited by 1,374
A tunable carbon nanotube electromechanical oscillator
Sazonova, V., Yaish, Y., Üstünel, H., Roundy, D., Arias, T. A., & McEuen, P. L. (2004) · Nature · doi:10.1038/nature02905 · Cited by 1,312
A picogram- and nanometre-scale photonic-crystal optomechanical cavity
Eichenfield, M., Camacho, R., Chan, J., Vahala, K. J., & Painter, O. (2009) · Nature · doi:10.1038/nature08061 · Cited by 703
Smart single-chip gas sensor microsystem
Hagleitner, C., Hierlemann, A., Lange, D., Kummer, A., Kerness, N., Brand, O., & Baltes, H. (2001) · Nature · doi:10.1038/35104535 · Cited by 619
Metadata
- Authors
- Stowe, T. D., Yasumura, K., Kenny, T. W., Botkin, D., Wago, K., & Rugar, D.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1997-07-14
- Volume
- 71
- Issue
- 2
- Pages
- 288-290
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2051007954
- Cited by
- 390
- References
- 10
- FWCI
- 8.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.