The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays
Abstract
Because the refractive index for hard x rays is slightly different from unity, the optical phase of a beam is affected by transmission through an object. Phase images can be obtained with extreme instrumental simplicity by simple propagation provided the beam is coherent. But, unlike absorption, the phase is not simply related to image brightness. A holographic reconstruction procedure combining images taken at different distances from the specimen was developed. It results in quantitative phase mapping and, through association with three-dimensional reconstruction, in holotomography, the complete three-dimensional mapping of the density in a sample. This tool in the characterization of materials at the micrometer scale is uniquely suited to samples with low absorption contrast and radiation-sensitive systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Snigirev, A., Snigireva, I., Kohn, V., Kuznetsov, S., & Schelokov, I. (1995) · Review of Scientific Instruments · doi:10.1063/1.1146073 · Cited by 1,493
Bonse, U., & Hart, M. (1965) · Applied Physics Letters · doi:10.1063/1.1754212 · Cited by 1,057
Facts relating to optical science
Talbot, W. H. F. (1836) · The Philosophical Magazine A Journal of Theoretical Experimental and Applied Physics · Cited by 914
Phase objects in synchrotron radiation hard x-ray imaging
Cloetens, P., Barrett, R., Baruchel, J., Guigay, J.-P., & Schlenker, M. (1996) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/29/1/023 · Cited by 853
Self-citationPhase–contrast X–ray computed tomography for observing biological soft tissues
Momose, A., Takeda, T., Itai, Y., & Hirano, K. (1996) · Nature Medicine · doi:10.1038/nm0496-473 · Cited by 850
Quantitative Phase Imaging Using Hard X Rays
Nugent, K. A., Gureyev, T. E., Cookson, D. F., Paganin, D., & Barnea, Z. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.2961 · Cited by 675
Observation of microstructure and damage in materials by phase sensitive radiography and tomography
Cloetens, P., Pateyron-Salomé, M., Buffière, J. Y., Peix, G., Baruchel, J., Peyrin, F., & Schlenker, M. (1997) · Journal of Applied Physics · doi:10.1063/1.364374 · Cited by 538
Self-citationImproved high resolution image processing of bright field electron micrographs
Kirkland, E. J. (1984) · Ultramicroscopy · doi:10.1016/0304-3991(84)90037-8 · Cited by 197
Cited by
Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
Pfeiffer, F., Weitkamp, T., Bunk, O., & David, C. (2006) · Nature Physics · doi:10.1038/nphys265 · Cited by 1,855
Diverse Applications of Nanomedicine
Pelaz, B., Alexiou, C., Alvarez-Puebla, R. A., Alves, F., Andrews, A. M., Ashraf, S., Balogh, L. P., Ballerini, L., Bestetti, A., Brendel, C., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b06040 · Cited by 1,350
Withers, P. J., Bouman, C., Carmignato, S., Cnudde, V., Grimaldi, D., Hagen, C. K., Maire, E., Manley, M., Du Plessis, A., & Stock, S. R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00015-4 · Cited by 1,079
Recent advances in X-ray microtomography applied to materials
Stock, S. R. (2008) · International Materials Reviews · doi:10.1179/174328008x277803 · Cited by 517
Bultreys, T., De Boever, W., & Cnudde, V. (2016) · Earth-Science Reviews · doi:10.1016/j.earscirev.2016.02.001 · Cited by 474
Metadata
- Authors
- Cloetens, P., Ludwig, W., Baruchel, J., Van Dyck, D., Van Landuyt, J., Guigay, J. P., & Schlenker, M.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1999-11-08
- Volume
- 75
- Issue
- 19
- Pages
- 2912-2914
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2020616936
- Cited by
- 1,078
- References
- 8
- FWCI
- 9.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays. https://app.cochat.ai/papers/10.1063/1.125225
- The paper
- Cloetens, P., Ludwig, W., Baruchel, J., Van Dyck, D., Van Landuyt, J., Guigay, J. P., & Schlenker, M. (1999). Holotomography: Quantitative phase tomography with micrometer resolution using hard synchrotron radiation x rays. Applied Physics Letters. https://doi.org/10.1063/1.125225
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.