Demonstration of a low-noise near-infrared photon counter with multiphoton discrimination
The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
We have demonstrated a system capable of directly measuring the photon-number state of a single pulse of light using a superconducting transition-edge sensor microcalorimeter. We verify the photon-number distribution of a weak pulsed-laser source at 1550 nm. Such single-photon metrology at telecommunication wavelengths provides the foundation for ensuring the security of photon sources used in implementations of quantum cryptography. Additionally, this system has the lowest noise equivalent power of any single-photon detector and combines high efficiency near-infrared photon counting with the ability to resolve multiphoton absorption events.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Superconducting nanowire single-photon detectors (SNSPDs) and transition-edge sensors (TESs) are two leading single-photon detection technologies, especially at infrared wavelengths [412-415].”
From Integrated photonics on thin-film lithium niobate (2021) · cites this paper as [413]
Citations
Cites
Correlation between Photons in two Coherent Beams of Light
BROWN, R. H., & TWISS, R. Q. (1956) · Nature · doi:10.1038/177027a0 · Cited by 2,573
Loudon, R. (2000) · doi:10.1093/oso/9780198501770.001.0001 · Cited by 1,890
Limitations on Practical Quantum Cryptography
Brassard, G., Lütkenhaus, N., Mor, T., & Sanders, B. C. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.1330 · Cited by 1,215
Electrically Driven Single-Photon Source
Yuan, Z., Kardynal, B. E., Stevenson, R. M., Shields, A. J., Lobo, C. J., Cooper, K., Beattie, N. S., Ritchie, D. A., & Pepper, M. (2002) · Science · doi:10.1126/science.1066790 · Cited by 1,172
Triggered Single Photons from a Quantum Dot
Santori, C., Pelton, M., Solomon, G., Dale, Y., & Yamamoto, Y. (2001) · Physical Review Letters · doi:10.1103/physrevlett.86.1502 · Cited by 928
An application of electrothermal feedback for high resolution cryogenic particle detection
Irwin, K. D. (1995) · Applied Physics Letters · doi:10.1063/1.113674 · Cited by 685
A single-photon turnstile device
Kim, J., Benson, O., Kan, H., & Yamamoto, Y. (1999) · Nature · doi:10.1038/17295 · Cited by 473
Cabrera, B., Clarke, R. M., Colling, P., Miller, A. J., Nam, S., & Romani, R. W. (1998) · Applied Physics Letters · doi:10.1063/1.121984 · Cited by 352
Self-citationHigh‐resolution, energy‐dispersive microcalorimeter spectrometer for X‐ray microanalysis
WOLLMAN, D. A., IRWIN, K. D., HILTON, G. C., DULCIE, L. L., NEWBURY, D. E., & MARTINIS, J. M. (1997) · Journal of Microscopy · doi:10.1046/j.1365-2818.1997.2670824.x · Cited by 241
Self-citationMultiphoton detection using visible light photon counter
Kim, J., Takeuchi, S., Yamamoto, Y., & Hogue, H. H. (1999) · Applied Physics Letters · doi:10.1063/1.123404 · Cited by 237
Quantum key distribution over a 48 km optical fibre network
Hughes, R. J., Morgan, G. L., & Peterson, C. G. (2000) · Journal of Modern Optics · doi:10.1080/09500340008244058 · Cited by 189
Long-distance entanglement-based quantum key distribution
Ribordy, G., Brendel, J., Gautier, J.-D., Gisin, N., & Zbinden, H. (2000) · Physical Review A · doi:10.1103/physreva.63.012309 · Cited by 186
Welty, R. P., & Martinis, J. M. (1991) · IEEE Transactions on Magnetics · doi:10.1109/20.133821 · Cited by 170
Self-citationPerformance and design of InGaAs/InP photodiodes for single-photon counting at 155 µm
Hiskett, P. A., Buller, G. S., Loudon, A. Y., Smith, J. M., Gontijo, I., Walker, A. C., Townsend, P. D., & Robertson, M. J. (2000) · Applied Optics · doi:10.1364/ao.39.006818 · Cited by 126
Zbinden, H., Bechmann-Pasquinucci, H., Gisin, N., & Ribordy, G. (1998) · Applied Physics B · doi:10.1007/s003400050574 · Cited by 105
Rarity, J. G., Wall, T. E., Ridley, K. D., Owens, P. C. M., & Tapster, P. R. (2000) · Applied Optics · doi:10.1364/ao.39.006746 · Cited by 95
Photon counting with passively quenched germanium avalanche
Owens, P. C. M., Rarity, J. G., Tapster, P. R., Knight, D., & Townsend, P. D. (1994) · Applied Optics · doi:10.1364/ao.33.006895 · Cited by 66
Phase‐resolved Crab Studies with a Cryogenic Transition‐Edge Sensor Spectrophotometer
Romani, R. W., Miller, A., Cabrera, B., Nam, S. W., & Martinis, J. M. (2001) · The Astrophysical Journal · doi:10.1086/323874 · Cited by 62
Self-citationAntireflection coatings for superconducting photodetectors
Rajteri, M., Rastello, M. L., & Monticone, E. (2000) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/s0168-9002(99)01423-0 · Cited by 23
Removal of a single photon by adaptive absorption
Calsamiglia, J., Barnett, S. M., Lütkenhaus, N., & Suominen, K. (2001) · Physical Review A · doi:10.1103/physreva.64.043814 · Cited by 20
Procházka, I. (2001) · Applied Optics · doi:10.1364/ao.40.006012 · Cited by 17
Research works printed but not linked: 2
- 2001, Phys. Rev. A, 63, 012309
- 2000, J. Mod. Opt., 47, 533
Cited by
The security of practical quantum key distribution
Scarani, V., Bechmann-Pasquinucci, H., Cerf, N. J., Dušek, M., Lütkenhaus, N., & Peev, M. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.1301 · Cited by 3,726
Gisin, N., & Thew, R. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.22 · Cited by 2,147
Single-photon detectors for optical quantum information applications
Hadfield, R. H. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.230 · Cited by 1,726
Integrated photonics on thin-film lithium niobate
Zhu, D., Shao, L., Yu, M., Cheng, R., Desiatov, B., Xin, C. J., Hu, Y., Holzgrafe, J., Ghosh, S., Shams-Ansari, A., et al. (2021) · Advances in Optics and Photonics · doi:10.1364/aop.411024 · Cited by 1,516
Opportunities for mesoscopics in thermometry and refrigeration: Physics and applications
Giazotto, F., Heikkilä, T. T., Luukanen, A., Savin, A. M., & Pekola, J. P. (2006) · Reviews of Modern Physics · doi:10.1103/revmodphys.78.217 · Cited by 1,058
Metadata
- Authors
- Miller, A. J., Nam, S. W., Martinis, J. M., & Sergienko, A. V.
- Affiliations
- National Institute of Standards and Technology (US)
- Boston University (US)
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2003-07-28
- Volume
- 83
- Issue
- 4
- Pages
- 791-793
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1964488950
- Cited by
- 285
- References
- 21
- Citations by year
- 2026: 7 · 2025: 8 · 2024: 13 · 2023: 8 · 2022: 12 · 2021: 7 · 2020: 10 · 2019: 13 · 2018: 10 · 2017: 13 · 2016: 11 · 2015: 10 · 2014: 11 · 2013: 17 · 2012: 8
- FWCI
- 15.26
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Quantum Information and Cryptography
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Superconducting and THz Device Technology
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Mechanical and Optical Resonators
- Keywords
- single-photon detection, transition edge sensors, microcalorimeter, noise equivalent power, telecom wavelengths, quantum cryptography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.