Theory of Magnetic Detection of the Heart's Electrical Activity
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The currents set up in the chest by the electromotive forces of the heart produce magnetic fields at the chest surface which have a peak intensity of about one microgauss. To detect these fields, an optimized coil assembly has been constructed which yields an rms noise level of about 10−8 G in a 1- to 40-cycle band. The design of the coil assembly and the interpretation of its output are based on an analysis employing an unusual form of the reciprocity theorem. The theory shows that magnetic detection is fundamentally different from its electric counterpart and may reveal new clinical information. It also shows how immunity to magnetic interference can be achieved without resorting to bulky and expensive magnetic shields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Detection of the magnetic field of the heart
Baule, G., & McFee, R. (1963) · American Heart Journal · doi:10.1016/0002-8703(63)90075-9 · Cited by 392
Cited by
Näätänen, R., & Picton, T. (1987) · Psychophysiology · doi:10.1111/j.1469-8986.1987.tb00311.x · Cited by 3,321
Magnetoencephalography: Evidence of Magnetic Fields Produced by Alpha-Rhythm Currents
Cohen, D. (1968) · Science · doi:10.1126/science.161.3843.784 · Cited by 750
Hari, R., Aittoniemi, K., Järvinen, M. L., Katila, T., & Varpula, T. (1980) · Experimental Brain Research · doi:10.1007/bf00237543 · Cited by 427
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Williamson, S. J., & Kaufman, L. (1981) · Journal of Magnetism and Magnetic Materials · doi:10.1016/0304-8853(81)90078-0 · Cited by 327
Wood, C. C., Cohen, D., Cuffin, B. N., Yarita, M., & Allison, T. (1985) · Science · doi:10.1126/science.3975600 · Cited by 320
Geselowitz, D. (1970) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1970.1066765 · Cited by 318
Demonstration of useful differences between magnetoencephalogram and electroencephalogram
Cohen, D., & Cuffin, B. N. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90005-6 · Cited by 300
MEG versus EEG localization test using implanted sources in the human brain
Cohen, D., Cuffin, B. N., Yunokuchi, K., Maniewski, R., Purcell, C., Cosgrove, G. R., Ives, J., Kennedy, J. G., & Schomer, D. L. (1990) · Annals of Neurology · doi:10.1002/ana.410280613 · Cited by 294
Comparison of the magnetoencephalogram and electroencephalogram
Neil Cuffin, B., & Cohen, D. (1979) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(79)90215-3 · Cited by 274
A bidomain model for anisotropic cardiac muscle
Geselowitz, D. B., & Miller, W. T. (1983) · Annals of Biomedical Engineering · doi:10.1007/bf02363286 · Cited by 273
Romani, G. L., Williamson, S. J., & Kaufman, L. (1982) · Review of Scientific Instruments · doi:10.1063/1.1136907 · Cited by 235
Magnetic fields around the torso: production by electrical activity of the human heart
Cohen, D. (1967) · Science · doi:10.1126/science.156.3775.652 · Cited by 116
Baule, G. M., & McFee, R. (1970) · American Heart Journal · doi:10.1016/0002-8703(70)90312-1 · Cited by 69
Self-citationCohen, D., Norman, J. C., Molokhia, F., & Hood, W. (1971) · Science · doi:10.1126/science.172.3990.1329 · Cited by 53
Savard, P., Cohen, D., Lepeschkin, E., Cuffin, B. N., & Madias, J. E. (1983) · Circulation Research · doi:10.1161/01.res.53.2.264 · Cited by 43
“This is a wellknown property of the MCG (Baule and McFee, 1965), and is important here in the interpretation of the dcMCG.”
BackgroundComparative capabilities of electrocardiography and magnetocardiography
Plonsey, R. (1972) · The American Journal of Cardiology · doi:10.1016/0002-9149(72)90179-8 · Cited by 24
Sensitivity of MEG and EEG to source orientation
Ahlfors, S. P., Han, J., Belliveau, J. W., & Hämäläinen, M. S. (2010) · Brain Topography · doi:10.1007/s10548-010-0154-x · Cited by 1
“Theoretically, a radially oriented current dipole produces no magnetic field outside a spherically symmetric volume conductor (Baule and McFee 1965; Grynszpan and Geselowitz 1973).”
Background
Metadata
- Authors
- Baule, G., & McFee, R.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1965-06-01
- Volume
- 36
- Issue
- 6
- Pages
- 2066-2073
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2049424211
- Cited by
- 112
- References
- 1
- FWCI
- 1.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.