Unshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometer
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
We describe a vector alkali–metal magnetometer that simultaneously and independently measures all three components of the magnetic field. Using a feedback system, the total field at the location of the magnetometer is kept near zero, suppressing the broadening due to spin-exchange collisions. The resonance linewidth and signal strength of the magnetometer compare favorably with two different scalar operation modes in which spin-exchange relaxation is only partially suppressed. Magnetic field sensitivity on the order of 1pT∕Hz is demonstrated in a laboratory environment without magnetic shields.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“At present, the main contenders are optical atomic magnetometers.Two different types of these have been proposed for MEG [47,48] and MCG [49].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [49]
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Self-citationHigh-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Self-citationTheory of spin-exchange optical pumping of3Heand129Xe
Appelt, S., Baranga, A. B.-A., Erickson, C. J., Romalis, M. V., Young, A. R., & Happer, W. (1998) · Physical Review A · doi:10.1103/physreva.58.1412 · Cited by 439
Self-citationOptically Driven Spin Precession
Bell, W. E., & Bloom, A. L. (1961) · Physical Review Letters · doi:10.1103/physrevlett.6.280 · Cited by 366
Sensitive magnetometry based on nonlinear magneto-optical rotation
Budker, D., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Zolotorev, M. (2000) · Physical Review A · doi:10.1103/physreva.62.043403 · Cited by 335
Spin-Exchange Shift and Narrowing of Magnetic Resonance Lines in Optically Pumped Alkali Vapors
Happer, W., & Tang, H. (1973) · Physical Review Letters · doi:10.1103/physrevlett.31.273 · Cited by 323
A laser-pumped magnetometer for the mapping of human cardiomagnetic fields
Bison, G., Wynands, R., & Weis, A. (2003) · Applied Physics B: Lasers and Optics · doi:10.1007/s00340-003-1120-z · Cited by 185
Light narrowing of rubidium magnetic-resonance lines in high-pressure optical-pumping cells
Appelt, S., Ben-Amar Baranga, A., Young, A. R., & Happer, W. (1999) · Physical Review A · doi:10.1103/physreva.59.2078 · Cited by 142
On the calibration of a vectorial 4He pumped magnetometer
Gravrand, O., Khokhlov, A., Mouël, J. L., & Léger, J. (2014) · Earth Planets and Space · doi:10.1186/bf03351692 · Cited by 67
Gilles, H., Hamel, J., & Cheron, B. (2001) · Review of Scientific Instruments · doi:10.1063/1.1364667 · Cited by 50
Research works printed but not linked: 1
- 1995, Opt. Spectrosc., 78, 292
Cited by
Items 101–200 of 320
Li, L., Tang, J., Zhao, B., Li, C., Zhou, B., & Zhai, Y. (2022) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ac9cea · Cited by 23
Spin Exchange Relaxation Free (SERF) Magnetometers
Savukov, I. (2016) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-34070-8_15 · Cited by 35
A dual-axis, high-sensitivity atomic magnetometer
Li, R., Quan, W., Fan, W., Li, X., Wang, Z., Zhai, Y., & Fang, J. (2017) · Chinese Physics B · doi:10.1088/1674-1056/26/12/120702 · Cited by 22
Optically pumped vector magnetometer using a strong bias magnetic field
Schönau, T., Scholtes, T., Wittkämper, F., Sekels, A., Hiebel, S., Oelsner, G., & Stolz, R. (2025) · Physical Review Applied · doi:10.1103/physrevapplied.23.024006 · Cited by 27
In Situ Measurement of Nonorthogonal Angles of a Three-Axis Vector Optically Pumped Magnetometer
Li, S., Lu, J., Ma, D., Wang, K., Gao, Y., Sun, C., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3144737 · Cited by 21
“Due to the limitations of the manufacturing technique and installation process, the optical beams or magnetic field axes of three-axis OPMs are not strictly orthogonal in practice, causing a nonnegligible misalignment of the sensitive axes [7]–[9].”
Three axis vector atomic magnetometer utilizing polarimetric technique
Pradhan, S. (2016) · Review of Scientific Instruments · doi:10.1063/1.4962021 · Cited by 21
Li, L., Tang, J., Zhao, B., Cao, L., Zhang, Y., & Zhai, Y. (2023) · Measurement · doi:10.1016/j.measurement.2023.113161 · Cited by 22
Sensitive and stable vector magnetometer for operation in zero and finite fields
Bison, G., Бондар, В. М., Schmidt-Wellenburg, P., Schnabel, A., & Voigt, J. (2018) · Optics Express · doi:10.1364/oe.26.017350 · Cited by 20
Zhao, J., Liu, G., Lu, J., Yang, K., Ma, D., Xing, B., Han, B., & Ding, M. (2019) · IEEE Access · doi:10.1109/access.2019.2954103 · Cited by 22
“realized a triaxial SERFmagnetometer in an unshielded environment by applying cross field modulation to two field components [12].”
BackgroundMethodInfluentialTriaxial closed-loop measurement based on a single-beam zero-field optically pumped magnetometer
Wang, K., Zhang, K., Zhou, B., Lu, F., Zhang, S., Yan, Y., Wang, W., & Lu, J. (2022) · Frontiers in Physics · doi:10.3389/fphy.2022.1059487 · Cited by 20
“operation methods, which have been verified by experiment [11,14,24,25,26,27].”
MethodSignal-enhanced spin-exchange relaxation-free atomic magnetometer
Li, C., Tang, J., Zhang, Y., Yuan, Z., Li, J., Zhai, Y., & Liu, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114247 · Cited by 22
Fast measurement of spin-exchange relaxation in the range of earth-scale magnetic field
Fang, C., Jiang, L., Liu, J., Zhu, J., Shao, Q., Pei, H., & Quan, W. (2023) · Measurement · doi:10.1016/j.measurement.2023.113449 · Cited by 20
Characterization of polarimetric based three axis atomic magnetometer
Pradhan, S., & Behera, R. (2019) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2019.03.004 · Cited by 20
Compact high-bandwidth single-beam optically-pumped magnetometer for biomagnetic measurement
Wu, T., Xiao, W., Peng, X., Wu, T., & Guo, H. M. (2024) · Biomedical Optics Express · doi:10.1364/boe.545624 · Cited by 19
“Alternatively, OPMs combined with SERF techniques can achieve precision biomagnetic measurements in the sub-femtotesla range [4,5].”
Yin, Y., Zhou, B., Yin, K., Wang, Y., Tang, J., Ye, M., Ning, X., & Han, B. (2021) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ac19e3 · Cited by 19
Wang, K., Lu, J., Yan, Y., Tang, J., Ye, M., Yin, K., Chai, Z., Zhou, B., Ning, X., & Han, B. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3136213 · Cited by 18
In Situ Compensation of Triaxial Magnetic Field Gradient for Atomic Magnetometers
Yang, K., Lu, J., Ma, Y., Wang, Z., Sun, B., Wang, Y., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3162607 · Cited by 29
Vector measurements using all optical scalar atomic magnetometers
Zhang, R., Mhaskar, R. R., Smith, K. A., Balasubramaniam, E., & Prouty, M. D. (2021) · Journal of Applied Physics · doi:10.1063/5.0037991 · Cited by 17
“For example, vector field information can be derived from the bias magnetic fields applied to atoms to achieve a zero-field condition [17, 18].”
BackgroundLiang, Y., Jiang, L., Liu, J., Fan, W., Zhang, W., Fan, S., Quan, W., & Fang, J. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.024004 · Cited by 17
Microfabricated Optically-Pumped Magnetometers
Jiménez-Martínez, R., & Knappe, S. A. (2016) · Smart sensors, measurement and instrumentation · doi:10.1007/978-3-319-34070-8_17 · Cited by 28
Single-Beam Double-Pass Miniaturized Atomic Magnetometer for Biomagnetic Imaging Systems
Li, X., Guo, Z., Yang, R., & Feng, Y. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3271201 · Cited by 17
Lu, Y. W., Zhai, Y., Fan, W., Zhang, Y., Li, X., Jiang, L., & Quan, W. (2020) · Optics Express · doi:10.1364/oe.390022 · Cited by 16
Compact atomic magnetometer for global navigation (NAV-CAM)
Bulatowicz, M., & Larsen, M. (2012) · IEEE/ION Position Location and Navigation Symposium · doi:10.1109/plans.2012.6236852 · Cited by 17
Common-mode noise reduction in an atomic spin gyroscope using optical differential detection
Duan, L., Quan, W., Jiang, L., Fan, W., Ding, M., Hu, Z., & Fang, J. (2017) · Applied Optics · doi:10.1364/ao.56.007734 · Cited by 16
RF atomic magnetometer array with over 40 dB interference suppression using electron spin resonance
Cooper, R. J., Prescott, D. W., Lee, G. J., & Sauer, K. L. (2018) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2018.08.007 · Cited by 17
All-Optical Nonzero-Field Vector Magnetic Sensor for Magnetoencephalography
Petrenko, M. V., Pazgalev, A. S., & Vershovskii, A. K. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.20.024001 · Cited by 15
Single‐Beam Vector Atomic Magnetometer with High Dynamic Range Based on Magnetic Field Modulation
Chen, J., Jiang, L., Zhao, X. H., Liu, J., Chai, Y., Tian, M., & Lu, Z. (2024) · Advanced Quantum Technologies · doi:10.1002/qute.202400289 · Cited by 15
Rogachev, E. A., Vetoshko, P. M., Gusev, N. A., Kozhaev, M. A., Prokopov, A. R., Попов, В. В., Dodonov, D. V., Shumilov, А. G., Shaposhnikov, А. N., Berzhansky, V. N., et al. (2016) · Applied Physics Letters · doi:10.1063/1.4964887 · Cited by 15
Ensemble spin fabrication and manipulation of NV centres for magnetic sensing in diamond
Mu, J., Qu, Z., Ma, Z., Zhang, S., Shi, Y., Gao, J., Zhang, X., Cao, H., Qin, L., Liu, J., et al. (2017) · Sensor Review · doi:10.1108/sr-09-2016-0163 · Cited by 15
Analysis and Correction of the Crosstalk Effect in a Three-Axis SERF Atomic Magnetometer
Yan, Y., Lu, J., Zhou, B., Wang, K., Liu, Z., Li, X., Wang, W., & Liu, G. (2022) · Photonics · doi:10.3390/photonics9090654 · Cited by 15
“Seltzer and Romails described a three-axis SERF magnetometer by applying two low-frequency modulation fields [17].”
MethodLong, T., Song, X., Han, B., Suo, Y., & Jia, L. (2023) · Metrologia · doi:10.1088/1681-7575/accd74 · Cited by 17
“According to the analysis, the relationship between the RMF along the x - and y -axes and the output of the magneto-meter is a positive Lorentzian curve, and the output maximum corresponds to zero magnetic field.”
InfluentialDong, H., Ye, H., Hu, M., & Ma, Z. (2023) · Micromachines · doi:10.3390/mi15010059 · Cited by 15
“The first demonstration of a SERF magne-tometer working in an earth environment used a 2-inch-thick aluminum shield, as shown in Figure 9b [20,50].”
MethodBrazhnikov, D. V., Vishnyakov, V. I., Ignatovich, S. M., Mesenzova, I. S., Andreeva, C., & Goncharov, A. (2021) · Applied Physics Letters · doi:10.1063/5.0059019 · Cited by 14
Miniature Wide-Range Three-Axis Vector Atomic Magnetometer
Li, J., Yicheng, D., Wang, X., Lu, H., & Liu, Y. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3112522 · Cited by 14
An Integrated Single-Beam Three-Axis High-Sensitivity Magnetometer
Su, S., Xu, Z.-Y., He, X., Yin, C., Kong, M., Zhang, X., Ruan, Y., Li, K., & Lin, Q. (2023) · Sensors · doi:10.3390/s23063148 · Cited by 16
“introduced a triaxial SERF magnetometer working in an unshielded environment [13].”
BackgroundDifferential Measurement With the Balanced Response of Optically Pumped Atomic Magnetometers
Ichihara, S., Mizutani, N., Ito, Y., & Kobayashi, T. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2016.2547364 · Cited by 14
“OPAMs are being developed as magnetic field measuring devices [5]–[8].”
BackgroundA vector atomic magnetometer based on the spin self-sustaining Larmor method
Zhao, Q., Fan, B. L., Wang, S. G., & Wang, L. J. (2019) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2019.03.025 · Cited by 16
Field-Polarization Sensitivity in rf Atomic Magnetometers
Gerginov, V. P. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.024008 · Cited by 15
Toward portable nuclear magnetic resonance devices using atomic magnetometers
Yu, D., Garcia, N. C., & Xu, S. (2009) · Concepts in Magnetic Resonance Part A · doi:10.1002/cmr.a.20134 · Cited by 14
Ingleby, S. J., Griffin, P. F., Arnold, A. S., Chouliara, M., & Riis, E. (2017) · Review of Scientific Instruments · doi:10.1063/1.4980159 · Cited by 13
Niu, Y., Duan, L., Zhang, J., Huang, J., Zhai, Y., & Quan, W. (2022) · Review of Scientific Instruments · doi:10.1063/5.0049994 · Cited by 13
Liu, S.-Q., Yu, Q.-Q., Zhou, H., & Sheng, D. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.19.044062 · Cited by 15
Wu, Z., Zhang, J., He, M., Ren, B., Wang, Z., Chen, W., Ou, Z., Yue, H., Zhou, X., & Liu, Y. (2023) · Optics Express · doi:10.1364/oe.484984 · Cited by 13
Fang, J., Wang, T., Zhang, H., Li, Y., & Cai, H. (2015) · Chinese Physics B · doi:10.1088/1674-1056/24/6/060702 · Cited by 15
Magnetic Field Vector Detection in Frequency Domain with an Optically Pumped Atomic Magnetometer
Mizutani, N., & Kobayashi, T. (2012) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2012.2200657 · Cited by 13
“under magnetic field follows the Bloch equation [10]”
BackgroundMa, Y., Zhang, K., Wang, Y., Yang, K., Zhai, Y., & Lu, J. (2022) · Optics Express · doi:10.1364/oe.459995 · Cited by 12
Li, S., Xing, B., Fang, X., Wang, K., Gao, Y., Wei, Q., & Han, B. (2023) · Results in Physics · doi:10.1016/j.rinp.2023.106546 · Cited by 14
Research on the anti-interference ability of optically pumped magnetometer
Li, L., Ding, Z., Tang, J., Zhao, B., & Zhai, Y. (2023) · Measurement · doi:10.1016/j.measurement.2023.113405 · Cited by 12
Vector magnetometry employing a rotating RF field in a single-beam optically pumped magnetometer
Zou, Y., Jiang, L., Bai, H., Liu, J., Fang, C., Zhu, J., Shao, Q., Xu, J., Zhou, X., & Quan, W. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115901 · Cited by 12
Chai, C., Yang, X. M., Zheng, Y., Heyat, M. B. B., Li, Y., Yang, D.-B., Chen, Y.-H., & Sawan, M. (2025) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2025.117321 · Cited by 15
Optimal Design of Planar Coils With Reverse Current Distribution for Atomic Devices
Wang, S., Lu, J., Lu, F., Lu, C., & Zhang, X. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3214619 · Cited by 15
“housing are typically used in atomic magnetometers [23], [26].”
Jofre, M., Romeu, J., & Jofre, L. (2023) · New Journal of Physics · doi:10.1088/1367-2630/acb37a · Cited by 16
Close-Loop Bell–Bloom Magnetometer with Amplitude Modulation
Huang, H., Dong, H., Hao, H.-J., & Hu, X. (2015) · Chinese Physics Letters · doi:10.1088/0256-307x/32/9/098503 · Cited by 13
All-Optical Vector Cesium Magnetometer
Sun, W., Huang, Q., Huang, Z., Wang, P.-W., & Zhang, J. (2017) · Chinese Physics Letters · doi:10.1088/0256-307x/34/5/058501 · Cited by 12
Microfabricated Optically-Pumped Magnetometers
Knappe, S. A. (2014) · Conference on Lasers and Electro-Optics · doi:10.1364/cleo_at.2014.am4l.4 · Cited by 12
A calibration method for coil constants using an atomic spin self-sustaining vector magnetometer
Zhao, Q., Fan, B. L., Wang, S. G., & Wang, L. J. (2020) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2020.166977 · Cited by 11
Quieting an environmental magnetic field without shielding
Xiao, K., Wang, L., Guo, J., Zhu, M., Zhao, X., Sun, X., Ye, C., & Zhou, X. H. (2020) · Review of Scientific Instruments · doi:10.1063/5.0007464 · Cited by 11
Wide-range and self-locking atomic magnetometer based on free spin precession
Miao, P.-X., Zheng, W., Yang, S., Wu, B., Cheng, B., Tu, J., Ke, H.-L., Yang, W., Wang, J., Jing-zhong, C., et al. (2019) · Journal of the Optical Society of America B · doi:10.1364/josab.36.000819 · Cited by 11
Ultra-Sensitive Optical Atomic Magnetometers and Their Applications
Savukov, I. (2010) · InTech eBooks · doi:10.5772/7153 · Cited by 13
“Actually, it was shown in a different paper (Seltzer & Romalis, 2004) that the SERF magnetometer can operate even in unshielded environment, if due field compensation is provided with a system of coils.”
BackgroundRomalis, M. V. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.209 · Cited by 11
Self-citationSingle-beam three-axis SERF atomic magnetometer based on coordinate system rotation
Zhang, J., Chen, T., Chen, W., Ou, Z., Yue, H., & Liu, Y. (2024) · Optics Express · doi:10.1364/oe.524308 · Cited by 11
Taue, S., Sugihara, Y., Kobayashi, T., Ishikawa, K., & Kamada, K. (2011) · Japanese Journal of Applied Physics · doi:10.1143/jjap.50.116604 · Cited by 12
Characterization of 87Rb MEMS vapor cells for miniature atomic magnetometers
Jiang, M., Zhai, H., Jiang, C., Wang, J., Chen, C., Zhang, Q., Wu, D., Zhang, B., Zeng, Z., Lin, J., et al. (2023) · Applied Physics Letters · doi:10.1063/5.0149388 · Cited by 15
Characterization of alkali-metal vapor cells fabricated with an alkali-metal source tablet
Ban, K., Hirai, Y., Tsujimoto, K., Terao, A., Mizutani, N., Kobayashi, T., & Tabata, O. (2016) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.4963108 · Cited by 11
Liu, X., Yang, Y., Ding, M., Quan, W., Hu, Y., Li, Y., Jin, W., & Fang, J. (2019) · Journal of Lightwave Technology · doi:10.1109/jlt.2019.2892479 · Cited by 11
“techniques [9].”
In-situ magnetic field compensation for zero-field NMOR atomic magnetometer
Zhang, C., Liu, J., Zhao, X. H., Chen, J., Yang, J., Li, J., & Jiang, L. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116385 · Cited by 9
Multipass cell SERF atomic magnetometer based on parallel plate configuration
Qi, Y., Wang, S., Ye, Z., Xu, N., Li, B., & Lu, J. (2025) · Optics Letters · doi:10.1364/ol.565523 · Cited by 11
Niu, Y., & Ye, C. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3299690 · Cited by 9
“[21] J. C. Allred, R. N. Lyman, T. W. Kornack, and M. V. Romalis, “High-sensitivity atomic magnetometer unaffected by spin-exchange relaxation,” Phys.”
MethodInfluentialLiu, Z., Lu, J., Hu, Z., Li, X., Yan, Y., Zhan, D., & Li, J. (2024) · Chinese Optics Letters · doi:10.3788/col202422.051201 · Cited by 9
“Atomic magnetometers utilize atomic Larmor precession to provide magnetic field information with ultrahigh sensitivity, making them valuable for a wide range of applications, including biological magnetic field measurements, zero-field magnetic resonance, and magnetic anomaly detection [1 – 4] .”
BackgroundGusarov, A., Baranga, A. B.-A., Levron, D., & Shuker, R. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aaa702 · Cited by 9
“The preferred method is cross-modulation, suggested by Seltzer and Romalis [18].”
MethodYao, H., Ma, D., Zhao, J., Lu, J., & Ding, M. (2019) · Photonic Sensors · doi:10.1007/s13320-019-0530-4 · Cited by 12
Qi, P.-L., Geng, X., Yang, G., Huang, G., & Li, G. (2020) · Journal of the Optical Society of America B · doi:10.1364/josab.404651 · Cited by 10
Intracavity mode locked laser magnetometer
Schmitt-Sody, A., Masuda, K., Velten, A. U., & Diels, J. (2010) · Optics Communications · doi:10.1016/j.optcom.2010.04.065 · Cited by 9
Optical pump magnetometers parametric correction method based on three-axis coil arrays
Liang, S., Zhu, Y., He, J., Qi, J., Jia, Y., Wang, A., Zhao, T., Wei, C., Jiao, H., Feng, L., et al. (2024) · Measurement · doi:10.1016/j.measurement.2024.115909 · Cited by 10
Experimental optimization of atomic magnetometer in nuclear magnetic resonance gyroscope
Zhang, K., Luo, Z., Tang, F., Zhao, N., & Wang, Y. (2020) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ab6caf · Cited by 9
Lei, G., Wu, W., Zhao, X., Chai, Z., Liu, Z., & Yuan, H. (2021) · AIP Advances · doi:10.1063/5.0062025 · Cited by 8
Magnetic Jones Vector Detection with rf Atomic Magnetometers
Motamedi, C. Z., & Sauer, K. L. (2023) · Physical Review Applied · doi:10.1103/physrevapplied.20.014006 · Cited by 8
Fu, Y.-Y., & Yuan, J. (2019) · Chinese Physics B · doi:10.1088/1674-1056/ab3442 · Cited by 8
Nonlinear magneto-optical rotation with parametric resonance
Put, P., Wcisło, P., Gawlik, W., & Pustelny, S. (2019) · Physical Review A · doi:10.1103/physreva.100.043838 · Cited by 8
Static weak magnetic field measurements based on low-field nuclear magnetic resonance
Wang, X., Zhu, M., Xiao, K., Guo, J., & Wang, L. (2019) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2019.106580 · Cited by 8
Bai, M., Huang, Y., Zhang, G., Zheng, W., Lin, Q., & Hu, Z. (2019) · Optics Express · doi:10.1364/oe.27.029534 · Cited by 9
Magnetically Induced Depolarization of Microwave Scattering from a Laser-Generated Plasma
Galea, C. A., Shneider, M. N., Dogariu, A., & Miles, R. B. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.12.034055 · Cited by 8
Dual axis atomic magnetometer and gyroscope enabled by nuclear spin perturbation
Hedges, M. P., Papneja, A., Paul, K., & Buchler, B. C. (2025) · New Journal of Physics · doi:10.1088/1367-2630/adc6b3 · Cited by 8
“It has also been shown that full 3-axis readout is possible with SERF magnetometers via the application of magnetic field modulations [25, 37].”
Qin, J., Zhou, Y., & Wang, Y. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3137161 · Cited by 8
Analysis and Suppression of the Cross-Axis Coupling Effect for Dual-Beam SERF Atomic Magnetometer
Lu, F., Wang, S., Xu, N., Li, B., Lu, J., & Han, B. (2022) · Photonics · doi:10.3390/photonics9110792 · Cited by 8
Zhang, G., Zeng, H., Guo, R., Zhang, Q., Yu, W., & Lin, Q. (2023) · Optics Letters · doi:10.1364/ol.496076 · Cited by 9
Analysis and suppression of cross-axis modulation coupling errors in optically pumped magnetometers
Long, T., Song, X., Duan, Z., Dai, Y., Suo, Y., Jia, L., & Han, B. (2024) · Measurement · doi:10.1016/j.measurement.2024.115824 · Cited by 8
An atomic magnetometer with autonomous frequency stabilization and large dynamic range
Pradhan, S., Mishra, S., Behera, R., Poornima, & Dasgupta, K. (2015) · Review of Scientific Instruments · doi:10.1063/1.4921901 · Cited by 10
Chen, C., Jiang, Q., Wang, Z., Zhang, Y., Luo, H., & Yang, K. (2020) · AIP Advances · doi:10.1063/5.0007009 · Cited by 7
Response optimization of a three-axis sensitive SERF magnetometer for closed-loop operation
Zhou, Y., Sun, Y., 汪, X. 茜. W., Qin, J., Zhang, X., & Wang, Y. (2023) · Chinese Physics B · doi:10.1088/1674-1056/ad0b00 · Cited by 7
Simultaneous stabilization of frequency and magnetic field with the tilted 0-0 state
Jau, Y., & Happer, W. (2005) · Applied Physics Letters · doi:10.1063/1.2131180 · Cited by 7
Liu, X.-J., Ding, M., Li, Y., Hu, Y., Jin, W., & Fang, J. (2018) · Chinese Physics B · doi:10.1088/1674-1056/27/7/073201 · Cited by 9
Ingleby, S. J., Griffin, P. F., Arnold, A. S., Choulaira, M., & Riis, E. (2017) · Strathprints: The University of Strathclyde institutional repository (University of Strathclyde) · Cited by 7
Dual-axis pi-pulse spin-exchange relaxation-free magnetometerPreprint
Zhivun, E., Bulatowicz, M., Hryciuk, A., & Walker, T. G. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1805.12286 · Cited by 7
Magnetic field compensation method of dual-beam SERF atomic magnetometer under probing-axis bias
Song, X., Wu, D., Long, T., Wu, Z., & Jia, L. (2025) · Measurement · doi:10.1016/j.measurement.2025.118102 · Cited by 8
Long, T., Song, X., Wu, Z., Suo, Y., Jia, L., Qi, S., Duan, Z., & Han, B. (2024) · Measurement · doi:10.1016/j.measurement.2024.114711 · Cited by 9
Modulation crosstalk effect analysis on single-beam SERF atomic magnetic gradiometer
Chen, T., Zheng, Z., Zhang, J., Chen, Z., Chen, W., Ou, Z., Yue, H., & Liu, Y. (2025) · Measurement · doi:10.1016/j.measurement.2025.117782 · Cited by 8
Measurement of129Xe frequency shift due to Cs—129Xe collisions
Fang, J., Wan, S., & Chen, Y. (2014) · Chinese Physics B · doi:10.1088/1674-1056/23/6/063401 · Cited by 8
Chip-Scale SERF Atomic Magnetometer without Magnetic Shield
Lu, L., Shang, J., Pan, Z., & Ji, Y. (2017) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc.2017.265 · Cited by 6
Zhang, W., Duan, L., Fan, W., & Quan, W. (2022) · Optics Express · doi:10.1364/oe.477452 · Cited by 6
Metadata
- Authors
- Seltzer, S. J., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- ORCID
- Seltzer, S. J.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2004-11-15
- Volume
- 85
- Issue
- 20
- Pages
- 4804-4806
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1978487837
- Cited by
- 320
- References
- 11
- Citations by year
- 2026: 19 · 2025: 29 · 2024: 22 · 2023: 33 · 2022: 32 · 2021: 21 · 2020: 24 · 2019: 30 · 2018: 16 · 2017: 16 · 2016: 11 · 2015: 9 · 2014: 8 · 2013: 10 · 2012: 12
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
- Keywords
- spin-exchange relaxation-free magnetometer, vector magnetometry, feedback control, resonance width, magnetic field sensitivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.