Unshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometer
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
We describe a vector alkali–metal magnetometer that simultaneously and independently measures all three components of the magnetic field. Using a feedback system, the total field at the location of the magnetometer is kept near zero, suppressing the broadening due to spin-exchange collisions. The resonance linewidth and signal strength of the magnetometer compare favorably with two different scalar operation modes in which spin-exchange relaxation is only partially suppressed. Magnetic field sensitivity on the order of 1pT∕Hz is demonstrated in a laboratory environment without magnetic shields.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“At present, the main contenders are optical atomic magnetometers.Two different types of these have been proposed for MEG [47,48] and MCG [49].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [49]
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Self-citationHigh-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Self-citationTheory of spin-exchange optical pumping of3Heand129Xe
Appelt, S., Baranga, A. B.-A., Erickson, C. J., Romalis, M. V., Young, A. R., & Happer, W. (1998) · Physical Review A · doi:10.1103/physreva.58.1412 · Cited by 439
Self-citationOptically Driven Spin Precession
Bell, W. E., & Bloom, A. L. (1961) · Physical Review Letters · doi:10.1103/physrevlett.6.280 · Cited by 366
Sensitive magnetometry based on nonlinear magneto-optical rotation
Budker, D., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Zolotorev, M. (2000) · Physical Review A · doi:10.1103/physreva.62.043403 · Cited by 335
Spin-Exchange Shift and Narrowing of Magnetic Resonance Lines in Optically Pumped Alkali Vapors
Happer, W., & Tang, H. (1973) · Physical Review Letters · doi:10.1103/physrevlett.31.273 · Cited by 323
A laser-pumped magnetometer for the mapping of human cardiomagnetic fields
Bison, G., Wynands, R., & Weis, A. (2003) · Applied Physics B: Lasers and Optics · doi:10.1007/s00340-003-1120-z · Cited by 185
Light narrowing of rubidium magnetic-resonance lines in high-pressure optical-pumping cells
Appelt, S., Ben-Amar Baranga, A., Young, A. R., & Happer, W. (1999) · Physical Review A · doi:10.1103/physreva.59.2078 · Cited by 142
On the calibration of a vectorial 4He pumped magnetometer
Gravrand, O., Khokhlov, A., Mouël, J. L., & Léger, J. (2014) · Earth Planets and Space · doi:10.1186/bf03351692 · Cited by 67
Gilles, H., Hamel, J., & Cheron, B. (2001) · Review of Scientific Instruments · doi:10.1063/1.1364667 · Cited by 50
Research works printed but not linked: 1
- 1995, Opt. Spectrosc., 78, 292
Cited by
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
“[30, 42, 43]) for converting a scalar sensor into a vector one that relies on the fact that if a small bias field is applied to the sensor in a certain direction in addition to the field to be measured, then the change in the overall field magnitude is linear in the projection of the bias field on the main field, and…”
Self-citationMagnetoencephalography with an atomic magnetometer
Xia, H., Ben-Amar Baranga, A., Hoffman, D., & Romalis, M. V. (2006) · Applied Physics Letters · doi:10.1063/1.2392722 · Cited by 441
Self-citationOptically pumped magnetometers: from quantum origins to multi-channel magnetoencephalography
Tierney, T. M., Holmes, N., Mellor, S., López, J. D., Roberts, G., Hill, R. M., Boto, E., Leggett, J., Shah, V., Brookes, M. J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.05.063 · Cited by 400
“However, there are OPM devices which can operate within the Earth's field (dispensing with the need for costly shielding), but, have until recently, been subject to much higher noise levels (Seltzer and Romalis, 2004).”
BackgroundSpin-exchange-relaxation-free magnetometry with Cs vapor
Ledbetter, M. P., Savukov, I. M., Acosta, V. M., Budker, D., & Romalis, M. V. (2008) · Physical Review A · doi:10.1103/physreva.77.033408 · Cited by 399
Self-citationMagnetic Sensitivity Beyond the Projection Noise Limit by Spin Squeezing
Sewell, R. J., Koschorreck, M., Napolitano, M., Dubost, B., Behbood, N., & Mitchell, M. W. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.253605 · Cited by 323
All-Optical Vector Atomic Magnetometer
Patton, B., Zhivun, E., Hovde, D. C., & Budker, D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.013001 · Cited by 185
Biomagnetism using SQUIDs: status and perspectives
Sternickel, K., & Braginski, A. I. (2006) · Superconductor Science and Technology · doi:10.1088/0953-2048/19/3/024 · Cited by 180
“Two different types of these have been proposed for MEG [47, 48] and MCG [49].”
BackgroundA microfabricated optically-pumped magnetic gradiometer
Sheng, D., Perry, A. R., Krzyzewski, S. P., Geller, S., Kitching, J., & Knappe, S. (2017) · Applied Physics Letters · doi:10.1063/1.4974349 · Cited by 179
Multi-channel atomic magnetometer for magnetoencephalography: A configuration study
Kim, K., Begus, S., Xia, H., Lee, S.-K., Jazbinsek, V., Trontelj, Z., & Romalis, M. V. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.10.040 · Cited by 170
“In the detection of the spontaneous brainwave or epileptic spikes, one can also usemagnetic fieldmodulation techniques to measure different components of the field (Li, 2006; Seltzer and Romalis, 2004).”
Self-citationNon-Invasive Functional-Brain-Imaging with an OPM-based Magnetoencephalography System
Borna, A., Carter, T. R., Colombo, A. P., Jau, Y.-Y., McKay, J., Weisend, M., Taulu, S., Stephen, J. M., & Schwindt, P. D. D. (2020) · PLOS ONE · doi:10.1371/journal.pone.0227684 · Cited by 158
“A magnetic field (either light induced or real) along the pump laser direction causes the sense axis to rotate in the plane perpendicular to the pump axis [23].”
BackgroundDetection of NMR signals with a radio-frequency atomic magnetometer
Savukov, I., Seltzer, S. J., & Romalis, M. V. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.12.012 · Cited by 153
Self-citationSERF Atomic Magnetometer–Recent Advances and Applications: A Review
Li, J., Quan, W., Zhou, B., Wang, Z., Lu, J., Hu, Z., Liu, G., & Fang, J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2863707 · Cited by 166
“In 2004, Seltzer and Romalis [63], at Princeton university, proposed”
BackgroundMethodInfluentialMagnetocardiography with a 16-channel fiber-coupled single-cell Rb optically pumped magnetometer
Kim, Y. J., Savukov, I., & Newman, S. (2019) · Applied Physics Letters · doi:10.1063/1.5094339 · Cited by 133
Parametric modulation of an atomic magnetometer
Li, Z., Wakai, R. T., & Walker, T. G. (2006) · Applied Physics Letters · doi:10.1063/1.2357553 · Cited by 135
Zero-field remote detection of NMR with a microfabricated atomic magnetometer
Ledbetter, M. P., Savukov, I., Budker, D., Shah, V., Knappe, S. A., Kitching, J. E., Michalak, D. J., Xu, S., & Pines, A. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0711505105 · Cited by 133
Multi-sensor magnetoencephalography with atomic magnetometers
Johnson, C. N., Schwindt, P. D. D., & Weisend, M. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/17/6065 · Cited by 131
“A well-documented zeroing procedure (Seltzer and Romalis 2004, Wyllie et al 2012a) is used to determine the required currents.”
MethodMagnetocardiography with a modular spin-exchange relaxation-free atomic magnetometer array
Wyllie, R., Kauer, M., Smetana, G. S., Wakai, R. T., & Walker, T. G. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/9/2619 · Cited by 125
Nonlinear magneto-optical rotation with frequency-modulated light in the geophysical field range
Acosta, V. M., Ledbetter, M. P., Rochester, S., Budker, D., Kimball, D. F. J., Hovde, D. C., Gawlik, W., Pustelny, S., Zachorowski, J., & Yashchuk, V. V. (2006) · Physical Review A · doi:10.1103/physreva.73.053404 · Cited by 123
Magnetic field imaging with microfabricated optically-pumped magnetometers
Alem, O., Mhaskar, R., Jiménez-Martínez, R., Sheng, D., LeBlanc, J., Trahms, L., Sander, T., Kitching, J., & Knappe, S. (2017) · Optics Express · doi:10.1364/oe.25.007849 · Cited by 124
Tang, J., Zhai, Y., Li, C., Zhang, Y., Li, L., Zhao, B., Zhou, B., Han, B., & Liu, G. (2021) · Optics Express · doi:10.1364/oe.425851 · Cited by 128
Borna, A., Iivanainen, J., Carter, T. R., McKay, J., Taulu, S., Stephen, J., & Schwindt, P. D. D. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2021.118818 · Cited by 120
Pustelny, S., Jackson Kimball, D. F., Pankow, C., Ledbetter, M. P., Wlodarczyk, P., Wcislo, P., Pospelov, M., Smith, J. R., Read, J., Gawlik, W., et al. (2013) · Annalen der Physik · doi:10.1002/andp.201300061 · Cited by 99
Modern radio-optical methods in quantum magnetometry
Aleksandrov, E. B., & Vershovskii, A. K. (2009) · Physics-Uspekhi · doi:10.3367/ufne.0179.200906f.0605 · Cited by 108
How to build a magnetometer with thermal atomic vapor: a tutorial
Fabricant, A. M., Novikova, I. V., & Bison, G. (2023) · New Journal of Physics · doi:10.1088/1367-2630/acb840 · Cited by 162
“Of course, many atomic magnetometers operate unshielded within Earth’s field (typically at the cost of sensitivity performance, see table 2), or unshielded within field-canceling coil systems [98, 103, 159].”
BackgroundThree-axis closed-loop optically pumped magnetometer operated in the SERF regime
Yan, Y., Lu, J., Zhang, S., Lu, F., Yin, K., Wang, K., Zhou, B., & Liu, G. (2022) · Optics Express · doi:10.1364/oe.458367 · Cited by 89
Jiménez-Martínez, R., Griffith, W. C., Wang, Y.-J., Knappe, S. A., Kitching, J. E., Smith, K., & Prouty, M. D. (2009) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2009.2023829 · Cited by 90
Atomic magnetometers for materials characterization
Romalis, M. V., & Dang, H. B. (2011) · Materials Today · doi:10.1016/s1369-7021(11)70140-7 · Cited by 83
Self-citationNon-destructive Faraday imaging of dynamically controlled ultracold atoms
Gajdacz, M., Pedersen, P. L., Mørch, T., Hilliard, A. J., Arlt, J., & Sherson, J. F. (2013) · Review of Scientific Instruments · doi:10.1063/1.4818913 · Cited by 76
Wang, T., Kimball, D. F. J., Sushkov, A. O., Aybas, D., Blanchard, J. W., Centers, G., O’Kelley, S. R., Wickenbrock, A., Fang, J., & Budker, D. (2017) · Physics of the Dark Universe · doi:10.1016/j.dark.2017.11.003 · Cited by 80
“When the pump beam is blocked, the magnetometer is insensitive to the magnetic field, so the noise limit other than the Johnson magnetic noise and the pump beam noise is measured by blocking the pump beam [53].”
BackgroundBelfi, J., Bevilacqua, G., Biancalana, V., Cartaleva, S., Dancheva, Y. V., & Moi, L. (2007) · Journal of the Optical Society of America B · doi:10.1364/josab.24.002357 · Cited by 79
Single-beam three-axis atomic magnetometer
Huang, H., Dong, H., Chen, L., & Gao, Y. (2016) · Applied Physics Letters · doi:10.1063/1.4960971 · Cited by 79
All-optical dual-axis zero-field atomic magnetometer using light-shift modulation
Li, X., Han, B., Zhang, K., Liu, Z., Wang, S., Yan, Y., & Lu, J. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.014023 · Cited by 75
Microwave-Free Vector Magnetometry with Nitrogen-Vacancy Centers along a Single Axis in Diamond
Zheng, H., Sun, Z., Chatzidrosos, G., Zhang, C., Nakamura, K., Sumiya, H., Ohshima, T., Isoya, J., Wrachtrup, J., Wickenbrock, A., et al. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.13.044023 · Cited by 85
Optically Pumped Magnetometers Recent Advances and Applications in Biomagnetism: A Review
Zhao, B., Li, L., Zhang, Y., Tang, J., Liu, Y., & Zhai, Y. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3297109 · Cited by 85
“[43] M. P. Ledbetter, I. M. Savukov, V. M. Acosta, D. Budker, and M. V. Romalis, “Spin-exchange-relaxation-free magnetometry with Cs vapor,” Phys.”
InfluentialFang, J., Wang, T., Quan, W., Yuan, H., Zhang, H., Li, Y., & Zou, S. (2014) · Review of Scientific Instruments · doi:10.1063/1.4881685 · Cited by 72
Fang, J., & Qin, J. (2012) · Review of Scientific Instruments · doi:10.1063/1.4756046 · Cited by 73
Microwave-Free Vector Magnetometry with Nitrogen-Vacancy Centers along a Single Axis in Diamond
Zheng, H., Sun, Z., Chatzidrosos, G., Zhang, C., Nakamura, K., Sumiya, H., Ohshima, T., Isoya, J., Wrachtrup, J., Wickenbrock, A., et al. (2020) · Institutional Repositories DataBase (IRDB) · Cited by 63
He, K., Wan, S., Sheng, J., Liu, D., Wang, C., Li, D., Qin, L., Luo, S., Qin, J., & Gao, J. (2019) · Review of Scientific Instruments · doi:10.1063/1.5066250 · Cited by 71
Long, T., Song, X., Han, B., Suo, Y., & Jia, L. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3331425 · Cited by 84
“Consequently, manual splicing errors within the coils are virtually unavoidable, culminating in nonorthogonality issues pertaining to the triaxial magnetic field [26], [27].”
BackgroundMethodSingle-Beam Atomic Magnetometer Based on the Transverse Magnetic-Modulation or DC-Offset
Liu, G., Tang, J., Yin, Y., Wang, Y., Zhou, B., & Han, B. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.2973201 · Cited by 64
“In this case, the density matrix assumes a spin-temperature distribution and the electron spin polarization can be well described by the Bloch equation [26], [27]”
MethodThree-axis atomic magnetometer based on spin precession modulation
Huang, H., Dong, H. F., Hu, X., Chen, L., & Gao, Y. (2015) · Applied Physics Letters · doi:10.1063/1.4935096 · Cited by 60
Zhang, C., Yuan, H., Tang, Z., Quan, W., & Fang, J. (2016) · Applied Physics Reviews · doi:10.1063/1.4972187 · Cited by 60
Nonlinear magneto-optical rotation with modulated light in tilted magnetic fields
Pustelny, S., Gawlik, W., Rochester, S., Kimball, D. F. J., Yashchuk, V. V., & Budker, D. (2006) · Physical Review A · doi:10.1103/physreva.74.063420 · Cited by 56
Blanchard, J. W., Sjolander, T. F., King, J. P., Ledbetter, M. P., Levine, E. H., Bajaj, V. S., Budker, D., & Pines, A. (2015) · Physical Review B · doi:10.1103/physrevb.92.220202 · Cited by 61
“As the field is increased, however, rotation of the nuclear spins mixes states with different mF , and rotation of the alkali electron spins elicits a change in the sensitive axis of the detector [46].”
BackgroundSpin-exchange relaxation-free magnetometer with nearly parallel pump and probe beams
Karaulanov, T. S., Savukov, I., & Kim, Y. J. (2016) · Measurement Science and Technology · doi:10.1088/0957-0233/27/5/055002 · Cited by 62
Magnetic Gradiometer for the Detection of Zero- to Ultralow-Field Nuclear Magnetic Resonance
Jiang, M., Picazo‐Frutos, R., Wu, T., Blanchard, J. W., Peng, X., & Budker, D. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.024005 · Cited by 53
Prospects for magnetic field communications and location using quantum sensors
Gerginov, V. P., da Silva, F. C. S., & Howe, D. A. (2017) · Review of Scientific Instruments · doi:10.1063/1.5003821 · Cited by 54
Zou, S., Zhang, H., Chen, X.-Y., & Fang, J. (2021) · Measurement · doi:10.1016/j.measurement.2021.110338 · Cited by 52
A fast determination method for transverse relaxation of spin-exchange-relaxation-free magnetometer
Lu, J., Qian, Z., & Fang, J. (2015) · Review of Scientific Instruments · doi:10.1063/1.4916681 · Cited by 52
An unshielded radio-frequency atomic magnetometer with sub-femtoTesla sensitivity
Keder, D. A., Prescott, D. W., Conovaloff, A., & Sauer, K. L. (2014) · AIP Advances · doi:10.1063/1.4905449 · Cited by 52
A single-beam dual-axis atomic spin comagnetometer for rotation sensing
Jiang, L., Liu, J., Liang, Y., Tian, M., & Quan, W. (2022) · Applied Physics Letters · doi:10.1063/5.0079429 · Cited by 45
Machine learning assisted vector atomic magnetometry
Meng, X., Zhang, Y., Zhang, X., Jin, S., Wang, T., Jiang, L., Xiao, L., Jia, S., & Xiao, Y. (2023) · Nature Communications · doi:10.1038/s41467-023-41676-x · Cited by 58
“Higher bandwidth can be obtained in vapor cells working in the higher temperature spin-exchange-relaxation-free regime [28].”
Modern radio-optical methods in quantum magnetometry
Aleksandrov, E. B., & Vershovskii, A. K. (2009) · Uspekhi Fizicheskih Nauk · doi:10.3367/ufnr.0179.200906f.0605 · Cited by 44
Vector Magnetometry Exploiting Phase-Geometry Effects in a Double-Resonance Alignment Magnetometer
Ingleby, S. J., O’Dwyer, C., Griffin, P. F., Arnold, A. S., & Riis, E. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.10.034035 · Cited by 45
Suppression of Light Shift for High-Density Alkali-Metal Atomic Magnetometer
Lu, J., Quan, W., Ding, M., Qi, L., & Fang, J. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2877771 · Cited by 42
“Based on (6), the three components of the magnetic field (Bx , By , Bz) could be compensated and measured using the magnetic field zeroing technique described in [22] and [23].”
MethodLiu, J., Jiang, L., Liang, Y., Liu, F., & Quan, W. (2020) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.2983595 · Cited by 41
Fang, J., Wang, T., Zhang, H., Li, Y., & Zou, S. (2014) · Review of Scientific Instruments · doi:10.1063/1.4902567 · Cited by 41
In-Situ Measurement of Electrical-Heating-Induced Magnetic Field for an Atomic Magnetometer
Lu, J., Wang, J., Yang, K., Zhao, J., Quan, W., Han, B., & Ding, M. (2020) · Sensors · doi:10.3390/s20071826 · Cited by 43
“Based on Equation (2), the three components of the quasi-static magnetic field can be orderly compensated to zero using the magnetic field zeroing technique described in [27,35] as: (1) Apply a small and low-frequency oscillating field Bo cos (ωt) along the z direction and compensate Bx, until the response of Sx to Bo…”
Multilayer Cylindrical Magnetic Shield for SERF Atomic Co-Magnetometer Application
Li, J., Quan, W., Han, B., Liu, F., Li, X., & Liu, G. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2890083 · Cited by 37
“However, an exception applies for unshielded atomic magnetometers, which only adopt active magnetic compensation coils to counteract the external magnetic field [13].”
BackgroundDynamics of a Spin-Exchange Relaxation-Free Comagnetometer for Rotation Sensing
Liu, J., Jiang, L., Liang, Y., Li, G., Cai, Z. Y., Wu, Z., & Quan, W. (2022) · Physical Review Applied · doi:10.1103/physrevapplied.17.014030 · Cited by 38
“The residual magnetic fields are canceled by the cross-modulation method and the compensation point B c is found to be 122 nT [31].”
BackgroundOptically-Pumped Magnetometers for MEG
Knappe, S. A., Sander, T. H., & Trahms, L. (2014) · Springer eBooks · doi:10.1007/978-3-642-33045-2_49 · Cited by 47
Self-Calibrating Vector Atomic Magnetometry through Microwave Polarization Reconstruction
Thiele, T., Lin, Y., Brown, M. O., & Regal, C. A. (2018) · Physical Review Letters · doi:10.1103/physrevlett.121.153202 · Cited by 38
Single-beam three-axis optically pumped magnetometers with sub-100 femtotesla sensitivity
Xiao, W., Wu, Y., Zhang, X., Feng, Y., Sun, C., Wu, T., Chen, J., Peng, X., & Guo, H. M. (2021) · Applied Physics Express · doi:10.35848/1882-0786/ac00d9 · Cited by 36
Li, S., Ma, D., Lu, J., Xing, B., Wang, K., Gao, Y., & Han, B. (2022) · Measurement · doi:10.1016/j.measurement.2022.111878 · Cited by 37
Three-dimensional atomic magnetometry
Dong, H., Fang, J., Zhou, B., Tang, X., & Qin, J. (2011) · The European Physical Journal Applied Physics · doi:10.1051/epjap/2011110392 · Cited by 38
Three-axis atomic magnetometer for nuclear magnetic resonance gyroscopes
Qiu, X., Xu, Z., Peng, X., Li, L., Zhou, Y., Wei, M., Zhou, M., & Xu, X. (2020) · Applied Physics Letters · doi:10.1063/1.5139040 · Cited by 35
Electromagnetic induction imaging with a scanning radio frequency atomic magnetometer
Deans, C., Cohen, Y., Yao, H., Maddox, B., Vigilante, A., & Renzoni, F. (2021) · Applied Physics Letters · doi:10.1063/5.0056876 · Cited by 35
Dual-Axis π -Pulse Magnetometer with Suppressed Spin-Exchange Relaxation
Zhivun, E., Bulatowicz, M., Hryciuk, A., & Walker, T. G. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.034040 · Cited by 37
Fan, W., Liu, G., Li, R., Quan, W., Jiang, L., & Duan, L. (2017) · Measurement Science and Technology · doi:10.1088/1361-6501/aa7888 · Cited by 33
Vector magnetometer based on the effect of coherent population trapping
Andryushkov, V., Radnatarov, D. A., & Kobtsev, S. M. (2022) · Applied Optics · doi:10.1364/ao.457087 · Cited by 34
Suppression of vapor cell temperature error for spin-exchange-relaxation-free magnetometer
Lu, J., Qian, Z., Fang, J., & Quan, W. (2015) · Review of Scientific Instruments · doi:10.1063/1.4927720 · Cited by 34
Ma, Y., Qiao, Z., Yu, M., Wang, Y., Chen, Y., Luo, G., Yang, P., Lin, Q., Zhao, L., Zhang, Y., et al. (2022) · Applied Physics Letters · doi:10.1063/5.0105945 · Cited by 35
Interference in Atomic Magnetometry
Jiang, M., Xu, W., Li, Q., Wu, Z., Suter, D., & Peng, X. (2020) · Advanced Quantum Technologies · doi:10.1002/qute.202000078 · Cited by 31
Atomic-Signal-Based Zero-Field Finding Technique for Unshielded Atomic Vector Magnetometer
Dong, H., Lin, H., & Tang, X. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2216951 · Cited by 34
“that atomic vapor cell works under zero fields, which for the first time demonstrated the feasibility of atomic vector magnetometer in the measurement of the unshielded field [11].”
BackgroundMethodMagnetic-field-compensation optical vector magnetometer
Papoyan, A., Shmavonyan, S., Khanbekyan, A., Khanbekyan, K., Marinelli, C., & Mariotti, E. (2016) · Applied Optics · doi:10.1364/ao.55.000892 · Cited by 35
Three-Axis Atomic Magnetometer Employing Longitudinal Field Modulation
Ding, Z., Yuan, J., Lu, G., Li, Y., & Long, X. (2017) · IEEE photonics journal · doi:10.1109/jphot.2017.2743013 · Cited by 32
“designed an unshielded three-axis atomic magnetometer exhibiting a sensitivity on the order of 1 pT/Hz [14].”
BackgroundUltrastable Optical Magnetometry
Wilson, N., Light, P. S., Luiten, A. N., & Perrella, C. (2019) · Physical Review Applied · doi:10.1103/physrevapplied.11.044034 · Cited by 33
Isotropic Scalar Quantum Sensing of Magnetic Fields for Industrial Application
Staacke, R., John, R., Wunderlich, R., Horsthemke, L., Knolle, W., Laube, C., Glösekötter, P., Burchard, B., Abel, B., & Meijer, J. (2020) · Advanced Quantum Technologies · doi:10.1002/qute.202000037 · Cited by 35
Huang, J., Fan, W., Wang, Z., Yuan, L., Zhang, K., Pei, H., Pang, H., & Quan, W. (2022) · Optics Express · doi:10.1364/oe.451042 · Cited by 30
Vectorial atomic magnetometer based on coherent transients of laser absorption in Rb vapor
Lenci, L., Auyuanet, A., Barreiro, S., Valente, P., Lezama, A., & Failache, H. (2014) · Physical Review A · doi:10.1103/physreva.89.043836 · Cited by 30
Pulsed vector atomic magnetometer using an alternating fast-rotating field
Wang, T., Lee, W., Limes, M. E., Kornack, T. W., Foley, E., & Romalis, M. V. (2025) · Nature Communications · doi:10.1038/s41467-025-56668-2 · Cited by 39
Self-citationMetasurface enabled on-chip double-beam scheme for SERF atomic magnetometer
Liang, Z., Zhou, B., Lu, J., Liu, Y., Hu, J., Zhou, P., Wang, W., Liu, L., Hu, G., & Ye, M. (2022) · Optics Communications · doi:10.1016/j.optcom.2022.128850 · Cited by 28
Miniature quad-channel spin-exchange relaxation-free magnetometer for magnetoencephalography
Li, J., Du, P., Fu, J., Wang, X.-T., Zhou, Q., & Wang, R. (2019) · Chinese Physics B · doi:10.1088/1674-1056/28/4/040703 · Cited by 27
A magnetometer suitable for measurement of the Earth's field based on transient atomic response
Lenci, L., Barreiro, S., Valente, P., Failache, H., & Lezama, A. (2012) · Journal of Physics B Atomic Molecular and Optical Physics · doi:10.1088/0953-4075/45/21/215401 · Cited by 27
Zhang, H., Zou, S., Quan, W., Chen, X., & Fang, J. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2019.2929283 · Cited by 28
“To avoid the influence of the residual magnetic field, existing in the magnetic shielding, on the measurement results, it was zeroed by employing a cross modulation method [31], [32] before the experiments.”
MethodLong, T., Han, B., Song, X., Suo, Y., Jia, L., & Ren, W. (2022) · Photonic Sensors · doi:10.1007/s13320-023-0684-y · Cited by 29
“[38] first demonstrated the feasibility of a cross-modulation-based method for in-situ field measurement under unshielded conditions in 2004.”
BackgroundVoigt-effect-based three-dimensional vector magnetometer
Pyragius, T., Florez, H. M., & Fernholz, T. (2019) · Physical Review A · doi:10.1103/physreva.100.023416 · Cited by 30
Zhang, S., Zhang, K., Zhou, Y., Ye, M., & Lu, J. (2022) · Optics Express · doi:10.1364/oe.464361 · Cited by 29
Search for exotic spin-dependent interactions with a spin-exchange relaxation-free magnetometer
Chu, P.-H., Kim, Y. J., & Savukov, I. (2016) · Physical review. D/Physical review. D. · doi:10.1103/physrevd.94.036002 · Cited by 25
High-sensitivity pump–probe atomic magnetometer based on single fiber-coupled
Zhao, B., Tang, J., Yang, H., Li, L., Zhang, Y., Liu, Y., & Zhai, Y. (2022) · Optics & Laser Technology · doi:10.1016/j.optlastec.2022.109025 · Cited by 25
Pang, H., Liu, F., Fan, W., Wu, Z., Yuan, Q., & Quan, W. (2023) · Optics Express · doi:10.1364/oe.478875 · Cited by 26
Ingleby, S. J., O’Dwyer, C., Griffin, P. F., Arnold, A. S., & Riis, E. (2017) · Physical Review A · doi:10.1103/physreva.96.013429 · Cited by 24
Feasibility of magnetomyography with optically pumped magnetometers in a mobile magnetic shield
Nordenström, S., Lebedev, V., Hartwig, S., Kruse, M., Marquetand, J. C., Broser, P. J., & Middelmann, T. (2024) · Scientific Reports · doi:10.1038/s41598-024-69829-y · Cited by 34
Kamada, K., Taue, S., & Kobayashi, T. (2011) · Japanese Journal of Applied Physics · doi:10.1143/jjap.50.056602 · Cited by 25
The development of a multichannel atomic magnetometer array for fetal magnetocardiography
Wylie, R. B. (2012) · Cited by 33
A 4He vector zero-field optically pumped magnetometer operated in the Earth-field
Bertrand, F., Jäger, T., Boness, A., Fourcault, W., Gal, G. L., Palacios-Laloy, A., Paulet, J., & Léger, J. (2021) · Review of Scientific Instruments · doi:10.1063/5.0062791 · Cited by 26
“The successful operation of a magnetometer based on the SERF effect in Earth field has been reported [27], but the breakdown of the SERF regime due to high-amplitude noises led to a degraded”
BackgroundTriaxial Vector Operation in Near-Zero Field of Atomic Magnetometer With Femtotesla Sensitivity
Lu, F., Lu, J., Li, B., Yan, Y., Zhang, S., Yin, K., Ye, M., & Han, B. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3162282 · Cited by 27
Wang, K., Ma, D., Li, S., Gao, Y., & Sun, J. (2022) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2022.114055 · Cited by 23
Stray magnetic field compensation with a scalar atomic magnetometer
Belfi, J., Bevilacqua, G., Biancalana, V., Cecchi, R., Dancheva, Y. V., & Moi, L. (2010) · Review of Scientific Instruments · doi:10.1063/1.3441980 · Cited by 23
Yang, H., Zhang, K., Wang, Y., & Zhao, N. (2019) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/ab541a · Cited by 23
Metadata
- Authors
- Seltzer, S. J., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- ORCID
- Seltzer, S. J.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2004-11-15
- Volume
- 85
- Issue
- 20
- Pages
- 4804-4806
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1978487837
- Cited by
- 320
- References
- 11
- Citations by year
- 2026: 19 · 2025: 29 · 2024: 22 · 2023: 33 · 2022: 32 · 2021: 21 · 2020: 24 · 2019: 30 · 2018: 16 · 2017: 16 · 2016: 11 · 2015: 9 · 2014: 8 · 2013: 10 · 2012: 12
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
- Keywords
- spin-exchange relaxation-free magnetometer, vector magnetometry, feedback control, resonance width, magnetic field sensitivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.