Unshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometer
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
We describe a vector alkali–metal magnetometer that simultaneously and independently measures all three components of the magnetic field. Using a feedback system, the total field at the location of the magnetometer is kept near zero, suppressing the broadening due to spin-exchange collisions. The resonance linewidth and signal strength of the magnetometer compare favorably with two different scalar operation modes in which spin-exchange relaxation is only partially suppressed. Magnetic field sensitivity on the order of 1pT∕Hz is demonstrated in a laboratory environment without magnetic shields.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“At present, the main contenders are optical atomic magnetometers.Two different types of these have been proposed for MEG [47,48] and MCG [49].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [49]
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Self-citationHigh-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Self-citationTheory of spin-exchange optical pumping of3Heand129Xe
Appelt, S., Baranga, A. B.-A., Erickson, C. J., Romalis, M. V., Young, A. R., & Happer, W. (1998) · Physical Review A · doi:10.1103/physreva.58.1412 · Cited by 439
Self-citationOptically Driven Spin Precession
Bell, W. E., & Bloom, A. L. (1961) · Physical Review Letters · doi:10.1103/physrevlett.6.280 · Cited by 366
Sensitive magnetometry based on nonlinear magneto-optical rotation
Budker, D., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Zolotorev, M. (2000) · Physical Review A · doi:10.1103/physreva.62.043403 · Cited by 335
Spin-Exchange Shift and Narrowing of Magnetic Resonance Lines in Optically Pumped Alkali Vapors
Happer, W., & Tang, H. (1973) · Physical Review Letters · doi:10.1103/physrevlett.31.273 · Cited by 323
A laser-pumped magnetometer for the mapping of human cardiomagnetic fields
Bison, G., Wynands, R., & Weis, A. (2003) · Applied Physics B: Lasers and Optics · doi:10.1007/s00340-003-1120-z · Cited by 185
Light narrowing of rubidium magnetic-resonance lines in high-pressure optical-pumping cells
Appelt, S., Ben-Amar Baranga, A., Young, A. R., & Happer, W. (1999) · Physical Review A · doi:10.1103/physreva.59.2078 · Cited by 142
On the calibration of a vectorial 4He pumped magnetometer
Gravrand, O., Khokhlov, A., Mouël, J. L., & Léger, J. (2014) · Earth Planets and Space · doi:10.1186/bf03351692 · Cited by 67
Gilles, H., Hamel, J., & Cheron, B. (2001) · Review of Scientific Instruments · doi:10.1063/1.1364667 · Cited by 50
Research works printed but not linked: 1
- 1995, Opt. Spectrosc., 78, 292
Cited by
Items 301–320 of 320
Three-Axis Magnetic Field Compensation for Array OPMs Base on Cross-Coupling Suppression Model
Niu, Y., Chen, S., Cheng, L., & Ye, C. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3564153 · Cited by 2
“It has been shown that the frequency spectrum of the signal, particularly the magnitude of the first and second harmonic components of the signal, can be observed to evaluate the effectiveness of magnetic field compensation [14].”
Mengyuan, 崔. C., Xuefeng, 王. W., Yicheng, 邓. D., & Huanxue, 和. H. (2025) · Laser & Optoelectronics Progress · doi:10.3788/lop250477
Three-Axis Closed-Loop Operation of SERF Optically Pumped Magnetometer Toward Unshielded Application
Qin, J., Xu, J., Mengyao, L., Jiang, Z., & Qu, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3625334
“In 2004, Seltzer et al. [11] built an unshielded SERF OPM by applying cross-directional magnetic field modulation.”
Recent advances in magnetocardiography
Kong, X., Yang, K., Zhang, Z., Pan, D., & Guo, C. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-41624-8.00001-2 · Cited by 2
Compact Optical Rotation Detection for Atomic Magnetometers Enabled by Beam-Splitting Metalens
Xu, R., Hu, J., Li, N., Yu, L., Wang, Z., & Ye, M. (2025) · IEEE Optoelectronics Global Conference (OGC) · doi:10.1109/ogc66041.2025.11262067
“This study proposes an integrated optical rotation detection scheme based on a polarization-multiplexing-encoding metalens, achieving polarization splitting, focusing, and signal extraction within a single planar element [13].”
Response-Enhanced Over-Polarization Measurement for SERF Magnetometer Based on Pump Beam Modulation
Wang, Y., Zhan, D., Fang, X., Zhang, Y., Wang, F., Lu, J., & Ma, D. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3650231
“…evolution of the electron spin polarization response of an atomic magnetometer operated in the SERF regime can be described by the Bloch equations [33] where P = ( P x , P y , P z ) is the electron spin polarization vector, q ( P ) is the slowing-down factor which depends on the spin polarization…”
Li, J., Wang, H., Wu, T., Liu, Y., & Guo, H. M. (2026) · Review of Scientific Instruments · doi:10.1063/5.0302200
Cai, Y., Pan, D., Yang, K., & Kong, X. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3666014 · Cited by 1
“However, these schemes, primarily based on cross-field modulation and electron paramagnetic resonance, are typically applied to dual-beam atomic magnetometers [29], [30] with only one sensitive axis.”
Optimization of Beam Characteristics for Quantum Magnetometers Based on 3D Mems Alkali Vapor Cells
Li, W., & Shang, J. (2026) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems64181.2026.11419071
“…the Larmor precession frequency, the spin polarization vector P of rubidium atoms inside the vapor cell can be described by the Bloch equation [11,12]: Where s is the photon polarization of the pump beam, R op is the optical pumping rate of resonant beam to rubidium atoms, and R int is the…”
Zero-field atomic magnetometer unaffected by longitudinal magnetic field interference
Zhan, D., Wang, Y., Liu, Z., Yan, Y., Hu, Z., & Lu, J. (2026) · Measurement · doi:10.1016/j.measurement.2026.121188
Dynamic manipulation of atom spins via AC Stark effect in ultra-sensitive quantum magnetic sensing
Zhou, C., Yan, Y. H., Zhou, Y., Wu, Y., Ding, X., Zhang, K., Wang, Z., & Lu, J. (2026) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2026.103209
Optimized Design of Dual-Layer Biplanar Coils for Compact Atomic Sensor Systems
Meng, J., Liu, F. M., Wu, Z., Dou, X., Lv, S., Pei, Y., Zhong, W., & Zhai, Y. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3687300
“The geometry of these coils determines the spatial magnetic field distribution [12] and modulates the spin dynamics of alkali-metal atoms for signal generation and detection [13].”
Chip-scale reflective optically pumped SERF magnetometer with distributed Bragg reflector
Liu, L., Liang, Z., Sun, Y., Hu, G., Zhou, P., Hu, J., Hou, G., Zhang, Y., & Ye, M. (2026) · Optics & Laser Technology · doi:10.1016/j.optlastec.2026.115885
Optimal and efficient inference tools for field tracking with precessing spins
Anonymous, Bania, P., Méndez-Avalos, D., Sierant, A., Mitchell, M. W., & Kołodyński, J. (2026) · Physical Review Applied · doi:10.1103/jfhj-kr1j
“…ones involving atoms of higher spin or different pump-probe geometry and polarisations, e.g., alignment-based mag-netometers [77–80]—as well as multiparameter sensing scenarios [67, 81], e.g., vector magnetometers [82–84], by simply enlarging the parameter space in the extended state x (s) t in Eq.”
Li, W., Li, W., Zhang, S., & Chen, X. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3711329
“According to (5), under a time-varying transverse magnetic field, the contribution of P z is much smaller than that of P x and therefore can be safely neglected [28], [29].”
Liu, Z., Silu, D., Wang, Z., Pang, H., Yan, Y., Lei, X., Wang, J., & Quan, W. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3720805
“The present experimental validation is performed on a SERF ASG platform, while the general concept may be extended to other atomic-spin gyroscope configura-tions with similar optical readout and auxiliary environmental sensing structures [6], [7].”
Scalable Silicon Nitride OPA‐Based Free‐Space Photonic Interface for Chip‐Scale Atomic Magnetometry
Sun, J., Chai, Z., Gu, J., Yu, S., Xu, Y., Meng, X., & Su, X. (2026) · Laser & Photonics Review · doi:10.1002/lpor.71737
Accurate vector measurement of residual magnetic fields with a Rb–Xe nuclear-spin magnetometer
Xu, J., Wang, H., Li, K., Sun, Z., He, X., & Zheng, W. (2026) · Review of Scientific Instruments · doi:10.1063/5.0334069
Atomic Vapor Based Quantum Sensors for Electromagnetic Fields Spanning DC to THz Frequencies
Mondal, N., Mishra, S. R., Alam, M. T., Sahoo, S. N., & Mohapatra, A. K. (2026) · Springer proceedings in physics · doi:10.1007/978-981-92-2948-2_6
Yang, Y., Li, Y., Su, Z., He, J., Jia, X., Wang, Y., & Wang, J. (2026) · Physical Review A · doi:10.1103/sbb6-t133
Metadata
- Authors
- Seltzer, S. J., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- ORCID
- Seltzer, S. J.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2004-11-15
- Volume
- 85
- Issue
- 20
- Pages
- 4804-4806
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1978487837
- Cited by
- 320
- References
- 11
- Citations by year
- 2026: 19 · 2025: 29 · 2024: 22 · 2023: 33 · 2022: 32 · 2021: 21 · 2020: 24 · 2019: 30 · 2018: 16 · 2017: 16 · 2016: 11 · 2015: 9 · 2014: 8 · 2013: 10 · 2012: 12
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
- Keywords
- spin-exchange relaxation-free magnetometer, vector magnetometry, feedback control, resonance width, magnetic field sensitivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.