Unshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometer
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
We describe a vector alkali–metal magnetometer that simultaneously and independently measures all three components of the magnetic field. Using a feedback system, the total field at the location of the magnetometer is kept near zero, suppressing the broadening due to spin-exchange collisions. The resonance linewidth and signal strength of the magnetometer compare favorably with two different scalar operation modes in which spin-exchange relaxation is only partially suppressed. Magnetic field sensitivity on the order of 1pT∕Hz is demonstrated in a laboratory environment without magnetic shields.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“At present, the main contenders are optical atomic magnetometers.Two different types of these have been proposed for MEG [47,48] and MCG [49].”
From Biomagnetism using SQUIDs: status and perspectives (2006) · cites this paper as [49]
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Self-citationHigh-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Self-citationTheory of spin-exchange optical pumping of3Heand129Xe
Appelt, S., Baranga, A. B.-A., Erickson, C. J., Romalis, M. V., Young, A. R., & Happer, W. (1998) · Physical Review A · doi:10.1103/physreva.58.1412 · Cited by 439
Self-citationOptically Driven Spin Precession
Bell, W. E., & Bloom, A. L. (1961) · Physical Review Letters · doi:10.1103/physrevlett.6.280 · Cited by 366
Sensitive magnetometry based on nonlinear magneto-optical rotation
Budker, D., Kimball, D. F., Rochester, S. M., Yashchuk, V. V., & Zolotorev, M. (2000) · Physical Review A · doi:10.1103/physreva.62.043403 · Cited by 335
Spin-Exchange Shift and Narrowing of Magnetic Resonance Lines in Optically Pumped Alkali Vapors
Happer, W., & Tang, H. (1973) · Physical Review Letters · doi:10.1103/physrevlett.31.273 · Cited by 323
A laser-pumped magnetometer for the mapping of human cardiomagnetic fields
Bison, G., Wynands, R., & Weis, A. (2003) · Applied Physics B: Lasers and Optics · doi:10.1007/s00340-003-1120-z · Cited by 185
Light narrowing of rubidium magnetic-resonance lines in high-pressure optical-pumping cells
Appelt, S., Ben-Amar Baranga, A., Young, A. R., & Happer, W. (1999) · Physical Review A · doi:10.1103/physreva.59.2078 · Cited by 142
On the calibration of a vectorial 4He pumped magnetometer
Gravrand, O., Khokhlov, A., Mouël, J. L., & Léger, J. (2014) · Earth Planets and Space · doi:10.1186/bf03351692 · Cited by 67
Gilles, H., Hamel, J., & Cheron, B. (2001) · Review of Scientific Instruments · doi:10.1063/1.1364667 · Cited by 50
Research works printed but not linked: 1
- 1995, Opt. Spectrosc., 78, 292
Cited by
Items 201–300 of 320
Li, L., Tang, J., Zhao, B., & Zhai, Y. (2023) · Results in Physics · doi:10.1016/j.rinp.2023.106728 · Cited by 7
Li, X., Quan, W., Fan, W., Li, R., Jiang, L., & Fang, J. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aaaefc · Cited by 6
Zero Magnetic Field Calibration for Single-Beam Atomic Magnetometers Using Second Harmonics
Saenyot, K., Shoji, Y., Takahashi, S., & Daibo, M. (2019) · IEEE Magnetics Letters · doi:10.1109/lmag.2019.2944804 · Cited by 6
Wang, B., Peng, X., Xiao, W., & Guo, H. M. (2022) · Physical Review A · doi:10.1103/physreva.106.063102 · Cited by 6
Zero-field atomic magnetometer to extract longitudinal magnetic field
Wang, S., Lu, J., Zhang, K., Zhao, L., Qi, Y., & Fang, J. (2025) · Physical Review Research · doi:10.1103/yjc6-b26g · Cited by 8
Pati, G. S., Tripathi, R., & Pulido, M. (2023) · Journal of Applied Physics · doi:10.1063/5.0168122 · Cited by 5
Floquet description of optically pumped magnetometers
Florez, H. M., & Pyragius, T. (2021) · Physical Review A · doi:10.1103/physreva.103.033113 · Cited by 6
Ma, Y., Qiao, Z., Chen, Y., Luo, G., Yu, M., Wang, Y., Lu, D., Zhao, L., Yang, P., Lin, Q., et al. (2023) · Optics Express · doi:10.1364/oe.483108 · Cited by 6
Observation and Control of π-Pulse Resonance in SERF Magnetometer
Lin, S., Tang, J., Yuan, Z., Li, C., & Zhai, Y. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3341112 · Cited by 5
“Solving these issues, closed-loop control and multiaxis decoupling methods have been introduced into modulated multiaxis magnetometers to improve the system robustness [41], [42], [43].”
MethodDetection of auditory evoked responses with atomic magnetometer
Xia, H., Baranga, A. B.-A., Hoffman, D., & Romalis, M. V. (2007) · International Congress Series · doi:10.1016/j.ics.2007.02.028 · Cited by 5
Self-citationMeasuring the enhancement factor of the hyperpolarized Xe in nuclear magnetic resonance gyroscopes
Xu, Z., Zhou, Y., Peng, X., Li, L., Qiu, X., Zhou, M., & Xu, X. (2021) · Physical Review A · doi:10.1103/physreva.103.023114 · Cited by 5
RetractedZou, S., Quan, W., Chen, X., Fang, J., & Zhang, H. L. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3150837 · Cited by 6
“[16] proposed a simultaneous and independent measurement of all three components of magnetic field.”
BackgroundOptically Pumped Magnetometers for MEG
Knappe, S. A., Sander, T. H., & Trahms, L. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5_49 · Cited by 7
Microfabricated optically pumped magnetometer arrays for biomedical imaging
Perry, A. R., Sheng, D., Krzyzewski, S., Geller, S., & Knappe, S. A. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2261167 · Cited by 5
Cai, Z. Y., Duan, L., Fan, S., Lei, X., & Quan, W. (2025) · Optics Express · doi:10.1364/oe.557259 · Cited by 4
Theoretical study of the close-loop atomic magnetometer with a transverse pumping feedback
Shi, M., & Dong, H. (2021) · Measurement Science and Technology · doi:10.1088/1361-6501/ac284d · Cited by 4
“The first one (method 1 in figure 2) directly feedbacks the magnetic field to keep the magnetometer working at near zero point, which needs a three-dimensional coil to compensate the magnetic field in real time [11].”
Zhao, B., Tang, J., Li, L., Liu, Y., & Zhai, Y. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3304705 · Cited by 7
“approaches, such as cross modulation [26], [27], Z -modulation”
BackgroundDuan, Z., Long, T., Wu, Z., Jia, L., Qi, S., Song, X., & Han, B. (2024) · Measurement · doi:10.1016/j.measurement.2024.116376 · Cited by 5
Fu, Y., Hao, X., Jia, R., Yin, W., Yu, X., Feng, X., & Zhang, D. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3561746 · Cited by 5
“Seltzer and Romalis [25] applied magnetic modulation along cross-axes after decomposing noise field directions to extract three-axis magnetic field vectors using frequency division demodulation of the output signals and then employed a feedback mechanism to cancel the components of the three-axis…”
Dual-Axis Optical Modulation Atomic Magnetometer With Tunable Sensitive Axes
Li, X., Han, B., Liu, Z., Wang, Z., Sheng, J., Gao, S., & Lu, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3595633 · Cited by 4
“This approximate treatment is widely applied in solving the Bloch equation of AMs [5], [9], [10], [20], [39], [40].”
Dynamic analysis of atomic magnetometer and co-magnetometer
Wang, S., Yu, L., & Wang, W. (2015) · Physica B Condensed Matter · doi:10.1016/j.physb.2015.12.040 · Cited by 4
Research on Non-magnetic Temperature Control System Applied to Alkali Vapor Cells
Fu, M., Huang, J., Ruan, J., & Quan, W. (2020) · Youth Academic Annual Conference of Chinese Association of Automation (YAC) · doi:10.1109/yac51587.2020.9337572 · Cited by 4
“The airflow heating method does not introduce magnetic field interference, but the temperature stability is not high enough, the airflow disturbance is large, and the heating uniformity is poor [5].”
BackgroundNamita, K., Ito, Y., & Kobayashi, T. (2021) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/ac0ba6 · Cited by 4
Petrenko, M. V., & Vershovskii, A. K. (2025) · Physical Review A · doi:10.1103/rmyw-8zny · Cited by 3
Feedback Methods for Vector Measurements Using an All-Optical Atomic Magnetometer
Bulatowicz, M., Tost, J., & Walker, T. G. (2023) · Sensors · doi:10.3390/s23094263 · Cited by 3
Enhanced all-optical vector atomic magnetometer enabled by artificial neural network
Qin, J., Xu, J., Jiang, Z., & Qu, J. (2024) · Applied Physics Letters · doi:10.1063/5.0218065 · Cited by 3
Zhu, J., Jiang, L., Zhao, X. H., Liu, J., Fang, C., Shao, Q., Zou, Y., Xu, J., & Wang, Z. (2024) · Measurement · doi:10.1016/j.measurement.2024.116022 · Cited by 3
Niu, Y., Cheng, L., Hou, X., & Ye, C. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3543684 · Cited by 4
“To achieve extremely high magnetic field measurement sensitivity, the ambient magnetic field must be close to zero to avoid spin decoherence [20], [21], [22].”
Development of spin-exchange relaxation free magnetometer with a compact heating system
Lee, H. J., Kim, K., Lee, S.-J., Kang, C. S., Yu, K. K., Lee, Y., & Moon, H. S. (2013) · ACTA IMEKO · doi:10.21014/acta_imeko.v2i1.46 · Cited by 3
An Atomic Magnetometer with Spin-Projection Noise Proportional to $\sqrt{{T}_{2}}$
Dong, H., Wang, X., Li, J., Chen, J.-L., & Ren, Y. (2019) · Chinese Physics Letters · doi:10.1088/0256-307x/36/2/020701 · Cited by 4
Single-channel vector magnetic information detection method based on diamond NV color center*
Wang, Q., Wang, R., Liu, J., Lin, S.-Z., Wu, L., Guo, H., Li, Z., Wen, H., Tang, J., Ma, Z., et al. (2021) · Chinese Physics B · doi:10.1088/1674-1056/abea84 · Cited by 3
Luo, W., Zhang, H., Liu, Y., Wei, X., Zhang, X., Wang, Y., & Yang, R. (2022) · Journal of Applied Physics · doi:10.1063/5.0096583 · Cited by 3
MEMS techniques for the parallel fabrication of Chip Scale Atomic Devices
Perez, M. A., Knappe, S. A., & Kitching, J. E. (2010) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2010.5690546 · Cited by 3
“Generally, current loops or coils with diameters larger than the vapor cells are required to create uniform fields at the cell [16, 17].”
BackgroundSensitivity optimization of Bell-Bloom magnetometers by manipulation of atomic spin synchronization
Ranjbaran, M., Tehranchi, M. M., Hamidi, S. M., & Khalkhali, S. M. H. (2018) · Physica C Superconductivity · doi:10.1016/j.physc.2018.02.011 · Cited by 3
Compact atomic magnetometer for global navigation (NAV-CAM)
Bevan, D., Bulatowicz, M., Clark, P., Griffith, R., Larsen, M., Luengo-Kovac, M., & Pavell, J. (2018) · IEEE International Symposium on Inertial Sensors and Systems (INERTIAL) · doi:10.1109/isiss.2018.8358161 · Cited by 4
“The high sensitivity and low noise performance demonstrated in the laboratory using shielded devices [1] is difficult to maintain when operating in an unshielded real world environment [2].”
BackgroundFaculty of Physics and Astronomy
Mayle, M. (2006) · Cited by 3
Static bias magnetic field assisted optical modulation triaxial SERF atomic magnetometer
Li, X., Han, B., Gao, S., Liu, Z., Wang, Z., Sheng, J., & Lu, J. (2025) · Measurement Science and Technology · doi:10.1088/1361-6501/ae1cda · Cited by 2
“However, the atomic spin ensemble cannot directly measure the magnetic field along the spin polarization direction, as the z -axis magnetic field does not affect the direction of spin polarization [20].”
Theory of atomic vector magnetometer using linearly polarized resonant light
Zhang, J., Ping-Wen, W., Yu, H., Chong, K., & Weimin, S. (2018) · Acta Physica Sinica · doi:10.7498/aps.67.20172108 · Cited by 2
Optically Pumped Magnetometers for MEG
Knappe, S. A., Sander, T. H., & Trahms, L. (2019) · Springer eBooks · doi:10.1007/978-3-319-62657-4_49-1 · Cited by 3
Two-dimensional biaxial magnetic field imaging with millisecond resolution
Lu, F., Li, B., Wang, S., Hu, Z., Ye, M., Lu, J., & Han, B. (2023) · Measurement · doi:10.1016/j.measurement.2023.113423 · Cited by 2
Kim, M. M., & Lee, S. (2024) · AIP Advances · doi:10.1063/5.0190271 · Cited by 2
Dawson, R., O’Dwyer, C., Mrozowski, M. S., Ingleby, S. J., Griffin, P. F., & Riis, E. (2024) · Optical and Quantum Sensing and Precision Metrology II · doi:10.1117/12.3002678 · Cited by 5
“Three-axis magnetic field extraction schemes for zero-field OPM have been proposed for dual 25,26 and single beam 22,23,27 OPM configurations to promising effect.”
BackgroundWu, H., Zhang, H., Tian, P., Zhao, X., & Zheng, S. (2024) · Physica Scripta · doi:10.1088/1402-4896/ad74a7 · Cited by 2
Tian, X., Bao, B., Wang, R., & Li, D. (2025) · Sensors · doi:10.3390/s25123690 · Cited by 3
Influence of Pump Light’s Duty Cycle on Cesium Atomic Magnetometer
Zeng, X. J., Zhang, J. H., Liu, Q., Huang, Z., & Sun, W. M. (2012) · Advanced materials research · doi:10.4028/www.scientific.net/amr.571.209 · Cited by 2
Three dimensional compensation spherical coils for compact atomic magnetometers
Zhuo, C., Dong, H., & Xuan, L. (2013) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2013.6559815 · Cited by 2
“Compared to SQUIDs which only measure the field component along one particular direction, vector atomic magnetometers can provide all three axes information [4].”
BackgroundOptically pumped magnetometry in arbitrarily oriented magnetic fields
Ingleby, S. J., Chalmers, I. C., O’Dwyer, C., Griffin, P. F., Arnold, A. S., & Riis, E. (2017) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2017.8233895 · Cited by 2
Qiang, S., Ji, F., Zhu, M., Wang, B., Deng, D., & Fei, Y. (2020) · Review of Scientific Instruments · doi:10.1063/5.0018011 · Cited by 2
Virtual Gradiometer-Based Noise Reduction Method for Wearable Magnetoencephalography
Xu, J.-Y., Chen, C.-Q., Zhang, X., Fu, F.-Y., Yang, X., Hu, T., & Chang, Y. (2022) · International Conference on Computer Science, Electronic Information Engineering and Intelligent Control Technology (CEI) · doi:10.1109/cei57409.2022.9950167 · Cited by 2
“1 pT/Hz1/2 to 1 pT/Hz1/2, which is comparable to the noise level in the unshielded environment[22].”
BackgroundNonlinear magneto-optical rotation - A possible tool for sensitive magnetometry
Srinivasan, R. (2007) · Cited by 5
Micro-Fabricated SERF Atomic Magnetometer for Weak Gradient Magnetic Field Detection
Yue, X., Shang, J., & Ye, C. (2019) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc.2019.00085 · Cited by 2
“Compared to SQUIDs that require expensive and large cryogenic cooling equipment, the Spin-Exchange-Relaxation-Free (SERF) [9] atomic magnetometer has significant advantages due to its small size and low power consumption.”
BackgroundInfluentialOptical frequency dependence of the light shift effect for vector magnetometry with cesium
Lou, J. W., & Cranch, G. A. (2020) · Applied Optics · doi:10.1364/ao.379800 · Cited by 2
Improved temperature stability of a fiber Sagnac-like detection system for atomic magnetometers
Zhang, J., Liu, X., Niu, Y., Lian-jun, M., Wang, K., & Ding, M. (2020) · Optics Express · doi:10.1364/oe.385489 · Cited by 2
Hao, J., Ke, H.-L., Yang, Z.-Y., & Han, B. (2021) · Sensors · doi:10.3390/s21092982 · Cited by 3
“In terms of the study of the pump method and power stability for the pump laser, compared with the pump method of non-modulation [12,13] and sinusoidal modulation [14,15], the pump method of square wave modulation [16–18] is more suitable for mobile platforms with the characteristics of less influence from the externa…”
MethodMultiparameter quantum metrology using strongly interacting spin systemsPreprint
Jiang, M., Ji, Y., Li, Q., Liu, R., Suter, D., & Peng, X. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2104.00211 · Cited by 5
Toward liquid cell quantum sensing: Ytterbium complexes with ultra-narrow absorptionPreprint
Shin, A. J., Zhao, C., Shen, Y., Dickerson, C. E., Li, B. Y., Bím, D., Atallah, T. L., Oyala, P. H., Alson, L. K., Alexandrova, A. N., et al. (2022) · ChemRxiv · doi:10.26434/chemrxiv-2022-vg4jr · Cited by 2
High sensitivity detuned single-light-source orthogonal pump-probe SERF atomic magnetometer
Wang, Y., Liu, Y., Yue, Z., Lin, S., Yuan, Z., Zhai, Y., & Tang, J. (2025) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2025.108866 · Cited by 2
Li, Y., Zhou, X., & Wang, W. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3559930 · Cited by 1
“Seltzer and Romalis [20] proposed a cross-modulation method for compensating remnant magnetic fields, which can simultaneously achieve compensation in all three directions.”
Quantum sensing based on strongly interacting nuclear spin systems
Li, Q., Ji, Y., Ran, L. I. U., Suter, D., Jiang, M., & Peng, X. (2025) · Acta Physica Sinica · doi:10.7498/aps.74.20250271 · Cited by 2
Rotating Polarization Magnetometry
Pustelny, S., & Włodarczyk, P. (2025) · Sensors · doi:10.3390/s25092682 · Cited by 2
“Unfortunately, due to the limited stability of current sources and inhomogeneities induced by compensation of the magnetic fields, these methods still suffers from a sensitivity loss.”
Han, X., Zhou, X., Cao, Z., Li, X., & Zhao, W. (2025) · Applied Optics · doi:10.1364/ao.575463 · Cited by 1
Robust Vector Decoupling of SERF Magnetometers Using Artificial Neural Network
Yu, B., Qin, J., Li, J., Wang, B., Zhang, X., Jiang, Z., & Qu, J. (2026) · IEEE Sensors Journal · doi:10.1109/jsen.2026.3651429 · Cited by 2
“In another approach, Seltzer and Romalis [18] employed two low-frequency modulation fields, but this technique’s reliance on approximations from steady-state Bloch equations restricts its operational bandwidth to only a few tens of Hertz.”
Response Model of Naturally Abundant Rubidium SERF Magnetomete
Sheng, J., Li, X., Liu, Z., Wang, Z., Gao, S., & Lu, J. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3654698 · Cited by 1
“…the probe beam relaxation rate R pr (the absorption rate of photons from the probe beam) into the Bloch equations, given by Seltzer and Romalis [18] and Ledbetter et al. [19] where the vector P represents the electron spin polarization of the alkali metal atom, q ( P ) is the slowing-down…”
Long, T., Wu, Z., Wu, D., Qi, S., Jia, L., Song, X., & Zheng, S. (2026) · Optics & Laser Technology · doi:10.1016/j.optlastec.2026.115248 · Cited by 1
Microwave-optical double-resonance vector magnetometry with warm Rb atoms
Babaei, B., Smith, B. D., Tretiakov, A., Narayanan, A., & LeBlanc, L. J. (2026) · Applied Physics Letters · doi:10.1063/5.0323832 · Cited by 1
A high stability magnetic field applied in atomic magnetometer system
Qiang, H., Zongjun, H., Liu, Q., Junhai, Z., & Weimin, S. (2012) · International Conference on Measurement, Information and Control · doi:10.1109/mic.2012.6273303 · Cited by 1
Tsuchida, M., Oida, T., & Kobayashi, T. (2013) · Electronics and Communications in Japan · doi:10.1002/ecj.11455 · Cited by 1
Low Noise VCSEL Driver for SERF Atomic Magnetometer
Wang, F., Hu, Z., & Liu, X. (2020) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/711/1/012093 · Cited by 1
Microwave-free vector magnetometry based on nitrogen vacancy ensembles in diamond
Zheng, H., Sun, Z., Chatzidrosos, G., Wickenbrock, A., & Budker, D. (2019) · Symposium Latsis on Diamond Photonics - Physics, Technologies and Applications · doi:10.1364/dp.2019.40 · Cited by 1
Time response of spin-polarized rubidium thermal gas with radio-frequency pulse driving
Wang, Y., Kang, Z., Li, Y., Ma, Q., Wang, Y., Dong, Y., & Wang, J. (2022) · Journal of Applied Physics · doi:10.1063/5.0082535 · Cited by 1
Lu, J., Wang, H., Wang, S., & Zhao, J. (2023) · IEEE International Conference on Electronic Measurement & Instruments · doi:10.1109/icemi59194.2023.10269828 · Cited by 1
“Common heating methods include flowing hot air heating, laser heating, and electric heating [7-10].”
BackgroundSimulation of Scalar-Mode Optically Pumped Magnetometers to Search Optimal Operating Conditions
Ito, Y., Tatsuya, G. O. T. O., & Takuma, H. O. R. I. (2023) · IEICE Transactions on Electronics · doi:10.1587/transele.2023sei0002 · Cited by 1
“In the procedure described above, the spin polarization of the alkali-metal atoms follows the Bloch equation [7]. where D is the diffusion constant of the alkali-metal atom, S is the spin polarization of the electron, B is the magnetic field vector, R 2 is the spin relaxation rate, R OP is the…”
BackgroundResearch on Response of Vector SERF Magnetometer: Towards Unshielded Operation
Qin, J., Xu, J., Mengyao, L., Jiang, Z., & Qu, J. (2024) · Conference on Precision Electromagnetic Measurements · doi:10.1109/cpem61406.2024.10646100 · Cited by 1
“The suppression ratio of the AC fields shows a strong potential of the system to operate under an unshielded environment without aluminium shields comparing to the setup in [1].”
BackgroundYan, Y., Lu, J., Wang, K., Lu, F., Zhang, S., Liu, Z., Li, X., & Zhou, B. (2024) · Chinese Optics Letters · doi:10.3788/col202422.101201 · Cited by 1
Zhang, J., Shang, J., Li, G., Lu, L., Pan, Z., Ji, Y., & Wong, C. (2018) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc.2018.00301 · Cited by 1
“where n is the density of Rubidium atoms, γ is their gyromagnetic ratio (7 Hz/nT for Rb87), T2 is the transverse spin relaxation time, V is the volume of the alkali vapor cell, and t is the measurement time [15].”
BackgroundLu, Y. W., Zhai, Y., Zhang, Y., & Quan, W. (2020) · AOPC 2020: Optical Sensing and Imaging Technology · doi:10.1117/12.2579793 · Cited by 1
Novel Magnetic-Sensing Modalities with Nitrogen-Vacancy Centers in Diamond
Zheng, H., Wickenbrock, A., Chatzidrosos, G., Bougas, L., Leefer, N., Afach, S., Jarmola, A., Acosta, V. M., Xu, J., Iwata, G. Z., et al. (2021) · IntechOpen eBooks · doi:10.5772/intechopen.95267 · Cited by 1
“magnetometry platforms have emerged over the past decades, such as Hall probes, flux-gate, tunneling-magnetoresistance [35], SQUID based magnetometry [36] and vapor-cell-based magnetometry [37, 38].”
BackgroundGradiometry-free noise suppression in RF atomic magnetometersPreprint
Gerginov, V. P. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1809.08978 · Cited by 2
Calibration and Thermal Analysis of a Conformal SERF Magnetometer Array for MEG Applications
Alexander, E. V. (2013) · PhDT
Two pulse per cavity lasers and their applications
Schmitt-Sody, A. (2011) · UNM’s Digital Repository (University of New Mexico)
Fast and non-destructive vector field magnetometry with cold atomic ensembles
Behbood, N., Ciurana, F. M., Colangelo, G., Napolitano, M., Sewell, R. J., & Mitchell, M. W. (2013) · Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC) · doi:10.1109/cleoe-iqec.2013.6801671
“In contrast to other vector magnetometer techniques that modulate an applied magnetic field [1, 2, 3] we modulate the initial atomic polarization and extract the magnetic field components from the resulting freeinduction decay (FID) signal, monitored via paramagnetic Faraday rotation.”
Anti-relaxation coating of the vapor cell
Xin, X., Yunhui, L., Yuanyuan, B., & Yun-Fei, X. (2013) · International Conference on Optoelectronics and Microelectronics · doi:10.1109/icoom.2013.6626535
“The demonstrations of high-density magnetometers, including the RF magnetometers and the SERF magnetometer, used cells filled with buffer gas because there was no available coating for operation at a high temperature [8] [9].”
MethodThe Effects of Pump Beam on Cesium Magnetometer Sensitivity
Li, Q. M., Zhang, J. H., Liu, Q., Huang, Z., & Sun, W. M. (2012) · Advanced materials research · doi:10.4028/www.scientific.net/amr.571.205
Influence of Spin Projection Noise on the Sensitivity of Cs Atom Magnetometer
Feng, W., Li, H., Bingsheng, L., changyu, R., & Hongxin, S. (2015) · The Open Automation and Control Systems Journal · doi:10.2174/1874444301507011968
“Under the working mechanism of this kind of magnetometer, the spin interaction rate is greatly more than Larmor precession rate [6, 7].”
Tsuchida, M., Oida, T., & Kobayashi, T. (2012) · IEEJ Transactions on Fundamentals and Materials · doi:10.1541/ieejfms.132.220
Wang, G., Miao, Y., Shan, X., & Gao, X. (2019) · Optik · doi:10.1016/j.ijleo.2019.02.045
The impact of radio-frequency magnetic field on atomic magnetometer
Fu, Y.-Y., & Yuan, J. (2019) · Tenth International Conference on Information Optics and Photonics · doi:10.1117/12.2542400
Qin, J., Zhang, X.-F., Chen, C., & Wang, Y. Z. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2001.08994
“Assuming that the probing signal is determined by atomic spin along x̂ axis Px, then we get the response of equation (1) to the superimposition,”
BackgroundInfluentialZamani, A., Ranjbaran, M., Tehranchi, M. M., Khalkhali, S. M. H., & Hamidi, S. M. (2020) · International Journal of Optics and Photonics · doi:10.29252/ijop.14.1.25
Automatic magnetic compensation system for SERF atomic comagnetometer
Wang, Z., Zhai, L., & Huang, J. (2020) · Youth Academic Annual Conference of Chinese Association of Automation (YAC) · doi:10.1109/yac51587.2020.9337652
Pulsed 87Rb vector magnetometer using a fast-rotating field
Wang, T., Lee, W., Romalis, M. V., Limes, M. E., Kornack, T., & Foley, E. L. (2022) · doi:10.26226/m.6275705766d5dcf63a311351
Self-citationA High-Sensitivity Single-Beam Triaxial Atomic Magnetometer Based on Optical Fiber Transmission
Wu, Z., Zhang, J., He, M., Ren, B., Wang, Z., Ou, Z., Yue, H., Zhou, X., & Liu, Y. (2022) · IEEE Conference on Telecommunications, Optics and Computer Science (TOCS) · doi:10.1109/tocs56154.2022.10015935
“Seltzer reported a triaxial vector atomic magnetometer in 2004 that realized a system sensitivity of 1pT/Hz1/2 in a gradiometer configuration with a modulation magnetic field applied on two orthogonal axes [2].”
Wang, S., Li, B., Qian, Y., Wang, H., Tang, S., & Lu, J. (2023) · IEEE International Conference on Electronic Measurement & Instruments · doi:10.1109/icemi59194.2023.10270702
“(cid:55)(cid:75)(cid:72) (cid:85)(cid:72)(cid:86)(cid:82)(cid:79)(cid:88)(cid:87)(cid:76)(cid:82)(cid:81) (cid:82)(cid:73) (cid:48)(cid:41)(cid:61)(cid:48) (cid:76)(cid:86) (cid:68)(cid:69)(cid:82)(cid:88)(cid:87) (cid:20)(cid:19) (cid:83)(cid:55)(cid:17) The resolution of MFZM is about 10 pT. (cid:55)(cid:82) (cid:86…”
BackgroundMethodInfluentialZinan, 吴. W., Jialong, 张. Z., Mengyang, 何. H., Bokang, 任. R., Zilong, 王. W., Zhonghua, 欧. O., Huimin, 岳. Y., Xiaojun, 周. Z., & Yong, 刘. L. (2024) · Laser & Optoelectronics Progress · doi:10.3788/lop230592
Enhanced optical pumping using mutually orthogonal magnetic fields for quantum sensing
Mandal, S., Grewal, R. S., & Pradhan, S. (2024) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/ad5e1c
Studies on Noise Reduction of Optically Pumped Magnetometers by Digital Signal Processing
Nambu, K., & Ito, Y. (2024) · IEEJ Transactions on Fundamentals and Materials · doi:10.1541/ieejfms.144.331 · Cited by 1
Zhan, D., Wang, Y., & Lu, J. (2024) · Advanced Sensor Systems and Applications · doi:10.1117/12.3037606
“Seltzer et al. presented a cross-field modulation method to compensate triaxial magnetic fields under unshielded condition[18].”
Studies on Noise Reduction of Optically Pumped Magnetometers by Digital Signal Processing
Nambu, K., & Ito, Y. (2025) · Electronics and Communications in Japan · doi:10.1002/ecj.12470
Impact of Thermal Induced Magnetic Noise on the Sensitivity of Atomic MagnetometersPreprint
Zhang, N., Wang, Z., & Guo, Q. (2025) · SSRN Electronic Journal · doi:10.2139/ssrn.5090523
Xinran, 宗. Z., & Haijun, 陈. C. (2025) · Laser & Optoelectronics Progress · doi:10.3788/lop242262 · Cited by 1
Metadata
- Authors
- Seltzer, S. J., & Romalis, M. V.
- Affiliations
- Princeton University (US)
- ORCID
- Seltzer, S. J.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2004-11-15
- Volume
- 85
- Issue
- 20
- Pages
- 4804-4806
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1978487837
- Cited by
- 320
- References
- 11
- Citations by year
- 2026: 19 · 2025: 29 · 2024: 22 · 2023: 33 · 2022: 32 · 2021: 21 · 2020: 24 · 2019: 30 · 2018: 16 · 2017: 16 · 2016: 11 · 2015: 9 · 2014: 8 · 2013: 10 · 2012: 12
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
- Keywords
- spin-exchange relaxation-free magnetometer, vector magnetometry, feedback control, resonance width, magnetic field sensitivity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.