Lateral force calibration in atomic force microscopy: A new lateral force calibration method and general guidelines for optimization
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Proper force calibration is a critical step in atomic and lateral force microscopies (AFM/LFM). The recently published torsional Sader method [C. P. Green et al., Rev. Sci. Instrum. 75, 1988 (2004)] facilitates the calculation of torsional spring constants of rectangular AFM cantilevers by eliminating the need to obtain information or make assumptions regarding the cantilever’s material properties and thickness, both of which are difficult to measure. Complete force calibration of the lateral signal in LFM requires measurement of the lateral signal deflection sensitivity as well. In this article, we introduce a complete lateral force calibration procedure that employs the torsional Sader method and does not require making contact between the tip and any sample. In this method, a colloidal sphere is attached to a “test” cantilever of the same width, but different length and material as the “target” cantilever of interest. The lateral signal sensitivity is calibrated by loading the colloidal sphere laterally against a vertical sidewall. The signal sensitivity for the target cantilever is then corrected for the tip length, total signal strength, and in-plane bending of the cantilevers. We discuss the advantages and disadvantages of this approach in comparison with the other established lateral force calibration techniques, and make a direct comparison with the “wedge” calibration method. The methods agree to within 5%. The propagation of errors is explicitly considered for both methods and the sources of disagreement discussed. Finally, we show that the lateral signal sensitivity is substantially reduced when the laser spot is not centered on the detector.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foam Structures with a Negative Poisson's Ratio
Lakes, R. (1987) · Science · doi:10.1126/science.235.4792.1038 · Cited by 3,866
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Cleveland, J. P., Manne, S., Bocek, D., & Hansma, P. K. (1993) · Review of Scientific Instruments · doi:10.1063/1.1144209 · Cited by 1,642
Novel optical approach to atomic force microscopy
Meyer, G., & Amer, N. M. (1988) · Applied Physics Letters · doi:10.1063/1.100061 · Cited by 1,290
Scratching the Surface: Fundamental Investigations of Tribology with Atomic Force Microscopy
Carpick, R. W., & Salmeron, M. (1997) · Chemical Reviews · doi:10.1021/cr960068q · Cited by 1,126
Self-citationCalibration of frictional forces in atomic force microscopy
Ogletree, D. F., Carpick, R. W., & Salmeron, M. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147411 · Cited by 604
Self-citationMeyer, G., & Amer, N. M. (1990) · Applied Physics Letters · doi:10.1063/1.103950 · Cited by 587
Normal and torsional spring constants of atomic force microscope cantilevers
Green, C. P., Lioe, H., Cleveland, J. P., Proksch, R., Mulvaney, P., & Sader, J. E. (2004) · Review of Scientific Instruments · doi:10.1063/1.1753100 · Cited by 551
Advances in negative Poisson's ratio materials
Lakes, R. (1993) · Advanced Materials · doi:10.1002/adma.19930050416 · Cited by 500
Carpick, R. W., Ogletree, D. F., & Salmeron, M. (1997) · Applied Physics Letters · doi:10.1063/1.118639 · Cited by 432
Self-citationAn improved wedge calibration method for lateral force in atomic force microscopy
Varenberg, M., Etsion, I., & Halperin, G. (2003) · Review of Scientific Instruments · doi:10.1063/1.1584082 · Cited by 427
Erratum: Novel optical approach to atomic force microscopy [Appl. Phys. Lett. 5 3, 1045 (1988)]
Meyer, G., & Amer, N. M. (1988) · Applied Physics Letters · doi:10.1063/1.100425 · Cited by 255
Clifford, C. A., & Seah, M. P. (2005) · Nanotechnology · doi:10.1088/0957-4484/16/9/044 · Cited by 181
Calibration procedures for frictional measurements with a lateral force microscope
Liu, E., Blanpain, B., & Célis, J. (1996) · Wear · doi:10.1016/0043-1648(95)06784-1 · Cited by 142
Calibration of silicon atomic force microscope cantilevers
Gibson, C. T., Smith, D. A., & Roberts, C. J. (2005) · Nanotechnology · doi:10.1088/0957-4484/16/2/009 · Cited by 114
Force Calibration in Lateral Force Microscopy
Cain, R. G., Biggs, S., & Page, N. W. (2000) · Journal of Colloid and Interface Science · doi:10.1006/jcis.2000.6840 · Cited by 109
Sader, J. E., Pacifico, J., Green, C. P., & Mulvaney, P. A. (2005) · Journal of Applied Physics · doi:10.1063/1.1935133 · Cited by 86
Hues, S. M., Draper, C. F., Lee, K. P., & Colton, R. J. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144892 · Cited by 80
In-plane deformation of cantilever plates with applications to lateral force microscopy
Sader, J. E., & Green, C. P. (2004) · Review of Scientific Instruments · doi:10.1063/1.1667252 · Cited by 70
Cantilever tilt compensation for variable-load atomic force microscopy
Cannara, R. J., Brukman, M. J., & Carpick, R. W. (2005) · Review of Scientific Instruments · doi:10.1063/1.1896624 · Cited by 70
Self-citationQuantitative comparison of three calibration techniques for the lateral force microscope
Cain, R. G., Reitsma, M. G., Biggs, S., & Page, N. W. (2001) · Review of Scientific Instruments · doi:10.1063/1.1386631 · Cited by 62
Stiernstedt, J., Rutland, M. W., & Attard, P. (2005) · Review of Scientific Instruments · doi:10.1063/1.2006407 · Cited by 60
Friction and wear on the atomic scale
Gnecco, E., Bennewitz, R., Socoliuc, A., & Meyer, E. (2003) · Wear · doi:10.1016/s0043-1648(03)00236-9 · Cited by 59
Cantilever calibration for nanofriction experiments with atomic force microscope
Morel, N., Ramonda, M., & Tordjeman, P. (2005) · Applied Physics Letters · doi:10.1063/1.1905803 · Cited by 22
Cited by
Recent advances in single-asperity nanotribology
Szlufarska, I., Chandross, M., & Carpick, R. W. (2008) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/41/12/123001 · Cited by 470
Self-citationAspects of scanning force microscope probes and their effects on dimensional measurement
Yacoot, A., & Koenders, L. (2008) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/41/10/103001 · Cited by 158
“Subsequently, Cannara et al (2006) described a method for the calibration of lateral force constants for AFM cantilevers.”
Mullin, N., & Hobbs, J. K. (2014) · Review of Scientific Instruments · doi:10.1063/1.4901221 · Cited by 58
Metadata
- Authors
- Cannara, R. J., Eglin, M., & Carpick, R. W.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2006-05-01
- Volume
- 77
- Issue
- 5
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W1987636437
- Cited by
- 214
- References
- 24
- FWCI
- 7.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.