Lateral force calibration of an atomic force microscope with a diamagnetic levitation spring system
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
A novel diamagnetic lateral force calibrator (D-LFC) has been developed to directly calibrate atomic force microscope (AFM) cantilever-tip or -bead assemblies. This enables an AFM to accurately measure the lateral forces encountered in friction or biomechanical-testing experiments at a small length scale. In the process of development, deformation characteristics of the AFM cantilever assemblies under frictional loading have been analyzed and four essential response variables, i.e., force constants, of the assembly have been identified. Calibration of the lateral force constant and the “crosstalk” lateral force constant, among the four, provides the capability of measuring absolute AFM lateral forces. The D-LFC is composed of four NdFeB magnets and a diamagnetic pyrolytic graphite sheet, which can calibrate the two constants with an accuracy on the order of 0.1%. Preparation of the D-LFC and the data processing required to get the force constants is significantly simpler than any other calibration methods. The most up-to-date calibration technique, known as the “wedge method,” calibrates mainly one of the two constants and, if the crosstalk effect is properly analyzed, is primarily applicable to a sharp tip. In contrast, the D-LFC can calibrate both constants simultaneously for AFM tips or beads with any radius of curvature. These capabilities can extend the applicability of AFM lateral force measurement to studies of anisotropic multiscale friction processes and biomechanical behavior of cells and molecules under combined loading. Details of the D-LFC method as well as a comparison with the wedge method are provided in this article.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Calibration of rectangular atomic force microscope cantilevers
Sader, J. E., Chon, J. W. M., & Mulvaney, P. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150021 · Cited by 2,145
Atomic-scale friction of a tungsten tip on a graphite surface
Mate, C. M., McClelland, G. M., Erlandsson, R., & Chiang, S. (1987) · Physical Review Letters · doi:10.1103/physrevlett.59.1942 · Cited by 1,763
Calibration of frictional forces in atomic force microscopy
Ogletree, D. F., Carpick, R. W., & Salmeron, M. (1996) · Review of Scientific Instruments · doi:10.1063/1.1147411 · Cited by 604
An improved wedge calibration method for lateral force in atomic force microscopy
Varenberg, M., Etsion, I., & Halperin, G. (2003) · Review of Scientific Instruments · doi:10.1063/1.1584082 · Cited by 427
Lateral, normal, and longitudinal spring constants of atomic force microscopy cantilevers
Neumeister, J. M., & Ducker, W. A. (1994) · Review of Scientific Instruments · doi:10.1063/1.1144646 · Cited by 334
Variation of the Interfacial Shear Strength and Adhesion of a Nanometer-Sized Contact
Carpick, R. W., Agraït, N., Ogletree, D. F., & Salmeron, M. (1996) · Langmuir · doi:10.1021/la9509007 · Cited by 301
Diamagnetic levitation: Flying frogs and floating magnets (invited)
Simon, M. D., & Geim, A. K. (2000) · Journal of Applied Physics · doi:10.1063/1.372654 · Cited by 281
A Technique for Measuring the Force between a Colloidal Particle in Water and a Bubble
Butt, H.-J. (1994) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1994.1277 · Cited by 260
The Colloidal Probe Technique and its Application to Adhesion Force Measurements
Kappl, M., & Butt, H.-J. (2002) · Particle & Particle Systems Characterization · doi:10.1002/1521-4117(200207)19:3<129::aid-ppsc129>3.0.co;2-g · Cited by 256
Cited by
Items 101–200 of 208
Interfacial Mechanical Properties of $n$ -Alkylsilane Monolayers on Silicon Substrates
Bush, B. G., Rio, F. W. D., Jaye, C., Fischer, D. A., & Cook, R. F. (2012) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2012.2213798 · Cited by 12
“properties and a diamagnetic lateral force calibration technique [32] to determine the torsional spring constant of the AFM”
MethodAtomic-scale interfacial instability of hydrogenated amorphous carbon film at elevated temperature
Wang, K., Zhang, J., Chen, W., Miao, X., & Ma, T. (2023) · Applied Surface Science · doi:10.1016/j.apsusc.2023.158280 · Cited by 11
Static and dynamic calibration of torsional spring constants of cantilevers
Labuda, A., Cao, C., Walsh, T., Meinhold, J., Proksch, R. B., Sun, Y., & Filleter, T. (2018) · Review of Scientific Instruments · doi:10.1063/1.5045679 · Cited by 11
Traceable Lateral Force Calibration (TLFC) for Atomic Force Microscopy
Bhattacharjee, A., Garabedian, N., Evans, C. L., & Burris, D. L. (2020) · Tribology Letters · doi:10.1007/s11249-020-01349-y · Cited by 11
Optimization of a 3D micro-accelerometer based on diamagnetic levitation
Pigot, C., DELINCHANT, B., Poulin‐Vittrant, G., & Reyne, G. (2009) · International Journal of Applied Electromagnetics and Mechanics · doi:10.3233/jae-2009-1020 · Cited by 11
“In addition, at the millimeter scale, resonators using diamagnetic levitation have a cut off frequency around 5 Hertz [8,10].”
Prunici, P., & Hess, P. (2007) · Ultramicroscopy · doi:10.1016/j.ultramic.2007.10.001 · Cited by 11
Liu, Y., Leung, K. M., Nie, H., Lau, W., & Yang, J. (2010) · Tribology Letters · doi:10.1007/s11249-010-9699-9 · Cited by 11
“designed for measuring the lateral sensitivity [12–15].”
Fabrication of AFM-Compatible Hydrogel Probe to Achieve Hydration Superlubrication in Salt Solutions
Wu, Z., Zhang, R., & Li, J. (2025) · Small · doi:10.1002/smll.202411253 · Cited by 13
Optimal control of diamagnetically levitated milli robots using automated search patterns
Pelrine, R., Hsu, A. L., Wong-Foy, A., McCoy, B., & Cowan, C. K. (2016) · International Conference on Manipulation, Automation and Robotics at Small Scales (MARSS) · doi:10.1109/marss.2016.7561725 · Cited by 10
“Our system uses diamagnetic levitation [8, 9], and the application of this form of levitation to micro robotics is fairly recent and only partially understood.”
MethodFriction imprint effect in mechanically cleaved BaTiO3 (001)
Long, C. J., Ebeling, D., Solares, S. D. J., & Cannara, R. J. (2014) · Journal of Applied Physics · doi:10.1063/1.4896531 · Cited by 10
Calibrating lateral displacement sensitivity of AFM by stick-slip on stiff, amorphous surfaces
Chu, L., Bus, M., Korobko, A. V., & Besseling, N. A. M. (2019) · Ultramicroscopy · doi:10.1016/j.ultramic.2019.05.012 · Cited by 10
Tuning frictional properties of molecularly thin erucamide films through controlled self-assembling
Di, Y., Zhang, S., Feng, X., & Li, Q. (2021) · Acta Mechanica Sinica · doi:10.1007/s10409-021-01122-x · Cited by 11
Self-citationBarkley, S. S., Deng, Z., Gates, R. S., Reitsma, M. G., & Cannara, R. J. (2012) · Review of Scientific Instruments · doi:10.1063/1.3685243 · Cited by 10
McClimon, J. B., Li, Z., Baral, K., Goldsby, D. L., Szlufarska, I., & Carpick, R. W. (2024) · Tribology Letters · doi:10.1007/s11249-024-01904-x · Cited by 9
“The AFM probes were calibrated for normal forces using the Sader method [46], and for lateral forces using the diamagnetic lateral force calibration technique [47].”
Performances improvement of MEMS sensors and energy scavengers by diamagnetic levitation
Pasquale, G. D., Siyambalapitiya, C., Somà, A., & Wang, J. (2009) · International Conference on Electromagnetics in Advanced Applications (ICEAA) · doi:10.1109/iceaa.2009.5297394 · Cited by 9
Lateral force microscopy of multiwalled carbon nanotubes
Lievonen, J., & Ahlskog, M. (2009) · Ultramicroscopy · doi:10.1016/j.ultramic.2009.03.028 · Cited by 9
Shape-Independent Lateral Force Calibration
Anderson, E., Chakraborty, S., Esformes, T., Eggiman, D. J., DeGraf, C., Stevens, K. M., Liu, D., & Burnham, N. A. (2011) · ACS Applied Materials & Interfaces · doi:10.1021/am200770r · Cited by 9
Calibration of T-shaped atomic force microscope cantilevers using the thermal noise method
Kim, Y., Mandriota, N., Goodnight, D., & Şahin, Ö. (2020) · Review of Scientific Instruments · doi:10.1063/5.0013091 · Cited by 8
New laser power sensor using weighing method
Pinot, P., & Silvestri, Z. (2017) · Measurement Science and Technology · doi:10.1088/1361-6501/aa902d · Cited by 8
Flexible Tuning of Friction on Atomically Thin Graphene
Zhao, X., Zhang, X., Chen, R., Lang, H., & Peng, Y. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c00098 · Cited by 8
Filtering Robust Graphite without Incommensurate Interfaces by Electrical Technique
Chen, W., Wu, T., Wang, Y., Wang, Y., Ma, M. D., Zheng, Q., & Wu, Z. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c12234 · Cited by 8
Shape Effect of Magnetic Source on Stabilizing Range of Vertical Diamagnetic Levitation
Chow, T.-Y., Wong, P. L., & Liu, K. P. (2011) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2011.2168824 · Cited by 8
Traceable characterization of a bending millimetre scale cantilever for nanoforce sensing
Stenlund, L., Riski, K., Seppä, J., Pudas, M., Vähäsöyrinki, M., Tuhkanen, V., & Röning, J. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/7/075102 · Cited by 8
Interlayer motion and ultra-low sliding friction in microscale graphite flakes
Wang, W., & Li, X. (2019) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/125/26003 · Cited by 8
Design and optimization of the diamagnetic lateral force calibration method
Qu, C., Liu, B., Ma, M. D., & Zheng, Q. (2018) · Review of Scientific Instruments · doi:10.1063/1.5041854 · Cited by 8
Zhao, X., Peng, Y., Cao, X., Yu, K., & Lang, H. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c20008 · Cited by 7
Zhang, Y., Li, J., Wang, Y., Nie, J., Wang, C., Tian, K., & Ma, M. D. (2024) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c16962 · Cited by 7
In Situ Hydrodynamic Lateral Force Calibration of AFM Colloidal Probes
Ryu, S., & Franck, C. (2011) · Langmuir · doi:10.1021/la201033e · Cited by 7
Tuning Electronic Friction in Structural Superlubric Schottky Junctions
Huang, X., Yu, Z., Tan, Z., Xiang, X., Chen, Y., Nie, J., Xu, Z., & Zheng, Q. (2024) · ACS Nano · doi:10.1021/acsnano.4c11163 · Cited by 6
McClimon, J. B., Hilbert, J., Koshigan, K. D., Fontaine, J., Lukes, J. R., & Carpick, R. W. (2023) · Tribology Letters · doi:10.1007/s11249-023-01712-9 · Cited by 6
“Lateral forces were calibrated using the diamagnetic lateral force calibration method [37].”
MethodModeling and Validation of Diamagnetic Rotor Levitated by Permanent Magnetics
Xu, Y., Zhang, Y., Zhou, J. H., & Jin, C. (2024) · Chinese Journal of Mechanical Engineering · doi:10.1186/s10033-024-01053-1 · Cited by 6
“Additionally, the inherent characterization of low stiffness in diamagnetic levitation system permits its potential application in high-sensitivity sensor [21-24] and ultra-low frequency energy harvesters [2526].”
BackgroundShear localization in ultralow wear of PEEK/UPE composites
Sun, W., Chen, T., Chen, T., Liu, X., & Ye, J. (2024) · Composites Part A Applied Science and Manufacturing · doi:10.1016/j.compositesa.2024.108484 · Cited by 8
Novel method for measuring nanofriction by atomic force microscope
Salvadori, M. C., Lisboa, F. S., Fernandes, F. M., & Brown, I. G. (2008) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.2890694 · Cited by 6
Stand-alone differential capacitance force sensors with sub-nano-newton sensitivity
Ye, J., Sun, T., Dong, H., Li, Z., & Li, L. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa81bc · Cited by 7
Superlubricity Between Alkane Molecules and Graphite: Effect of Alkane Chain Length
Wu, Z., Xiong, Y., Yang, Y., Zeng, Q., & Li, J. (2025) · Small · doi:10.1002/smll.202506692 · Cited by 5
Atomic stick-slip friction as a two-dimensional thermally activated process
Yao, Q., Sun, J., Zhuang, X., Wriggers, P., Feng, X., & Li, Q. (2022) · Physical review. B./Physical review. B · doi:10.1103/physrevb.105.165429 · Cited by 5
Self-citationZhou, Y., Chen, L., Wang, Y., Zhu, J., Guo, Z., Liu, C., Guo, Z., Wang, C., Zhang, H., Wang, Y., et al. (2023) · Inorganic Chemistry · doi:10.1021/acs.inorgchem.2c03870 · Cited by 5
Investigation of Programmable Friction with Ionic Liquid Mixtures at the Nano- and Macroscales
Gatti, F. J., Cai, W., Herzog, R., Gharavian, A., Kailer, A., Baltes, N. T. M., Rabenecker, P. M., Mörchel, P., Balzer, B. N., Amann, T., et al. (2023) · Lubricants · doi:10.3390/lubricants11090376 · Cited by 5
Analytical and experimental study of micromachined graphite rotor based on diamagnetic levitation
Su, Y., Ye, Z., Xiao, Z., & Takahata, K. (2015) · IEEE International Conference on Nano/Micro Engineered and Molecular Systems · doi:10.1109/nems.2015.7147387 · Cited by 5
McClimon, J. B., Hilbert, J., Lukes, J. R., & Carpick, R. W. (2020) · Tribology Letters · doi:10.1007/s11249-020-01319-4 · Cited by 5
Lateral force calibration for atomic force microscope cantilevers using a suspended nanowire
Zhang, G., Li, P., Wei, D., Hu, K., & Qiu, X. (2020) · Nanotechnology · doi:10.1088/1361-6528/abae32 · Cited by 5
Yao, Q., & Li, Q. (2016) · Tribology Letters · doi:10.1007/s11249-016-0761-0 · Cited by 4
“The normal force and lateral force constants were calibrated with the Sader method [43] and a diamagnetic lateral force calibrator [44], respectively.”
MethodSelf-citationA Hybrid Two-Axis Force Sensor for the Mesoscopic Structural Superlubricity Studies
Sun, T., Wu, Z., Li, Z., Zheng, Q.-S., & Lin, L. W. (2019) · Sensors · doi:10.3390/s19153431 · Cited by 4
“It has been reported that the magnetic levitation system has a very small friction coefficient [35,36], which is a promising choice.”
BackgroundDiamagnetic Levitation Thermometer
Inomata, N., Inomata, E., & Ono, T. (2020) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.23115 · Cited by 4
Tunable friction of monolayer MoS2 by control of interfacial chemistry
Chen, W., Tang, C., Li, T., Zou, X., Zhang, J., Jia, S., Yuan, J., George, A., Voronine, D. V., Ajayan, P. M., et al. (2020) · Extreme Mechanics Letters · doi:10.1016/j.eml.2020.100996 · Cited by 4
Self-citationSong, Q., Liu, K., Sun, W., & Ye, J. (2022) · Tribology Letters · doi:10.1007/s11249-022-01592-5 · Cited by 4
“AFM lateral force calibration methods like the DLFC [31] and TLFC [32] can be directly used in microtribometers.”
MethodInfluentialGraphene used as a lateral force microscopy calibration material in the low-load non-linear regime
Boland, M. J., Hempel, J. L., Ansary, A., Nasseri, M., & Strachan, D. R. (2018) · Review of Scientific Instruments · doi:10.1063/1.5044727 · Cited by 4
System modelling of a lateral force microscope
Michal, G., Lü, C., & Tieu, A. K. (2008) · Nanotechnology · doi:10.1088/0957-4484/19/45/455707 · Cited by 4
Nanoscale friction force on thin films of polymer blends and silane layers matrix
Wubetu, G. A. (2022) · Tribology International · doi:10.1016/j.triboint.2022.107984 · Cited by 3
Edge-enhanced super microgenerator based on a two-dimensional Schottky junction
Yu, Z., Xiao, Y., Huang, X., Liu, C., He, Y., & Ma, M. D. (2024) · Journal of Physics Condensed Matter · doi:10.1088/1361-648x/ad5507 · Cited by 4
“The C-AFM probe was calibrated in-situ by the Sader method [44, 45] for the normal direction force and the diamagnetic levitation spring system [46] for the lateral direction force.”
Conductive edge-warping graphite mesas for robust structural superlubricity
Feng, W., Liu, Y., Ma, M. D., Peng, D., & Nie, J. (2024) · Science China Technological Sciences · doi:10.1007/s11431-024-2707-4 · Cited by 2
“The Sader method [25] is utilized for normal force calibration, whereas the diamagnetic lateral force calibration method [26] is employed for lateral force calibration.”
Scaling Up AFM Friction Studies: Tailored Probes for Cross-Scale Measurements on Single-Crystal MoS2
Chen, T., Song, Q., Huang, Z., Liu, K., & Ye, J. (2025) · Tribology Letters · doi:10.1007/s11249-025-02058-0 · Cited by 2
“[35], which is considered the gold standard for direct AFM lateral force calibration.”
InfluentialRole of Stiffness in Friction with Graphite
He, Y., Yu, Z., Wang, J., Xing, T., & Ma, M. D. (2025) · Physical Review Letters · doi:10.1103/bpg9-zyq8 · Cited by 2
Quantitative estimation of nanoparticle/substrate adhesion by atomic force microscopy
Çiçek, A., Kratzer, M., Teichert, C., & Mitterer, C. (2026) · Beilstein Journal of Nanotechnology · doi:10.3762/bjnano.17.1 · Cited by 2
Integration of contact size dependence and thermal activation in atomic friction
Zhang, J., Lee, J. H., Lou, J., & Gao, Y. (2015) · Extreme Mechanics Letters · doi:10.1016/j.eml.2015.01.005 · Cited by 2
Pyrolytic carbon: applications of its diamagnetism in metrology
Pinot, P., & Silvestri, Z. (2019) · International Journal of Metrology and Quality Engineering · doi:10.1051/ijmqe/2019008 · Cited by 2
Rotor Designs in Pyrolytic Graphite Bearingless Motor for Increased Passive Radial Stiffness
Sugimoto, H., & Meki, S. (2023) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce53617.2023.10362839 · Cited by 2
“In [18 /mm ~ 30 µ N/mm, the highest natural frequency is 9.55 Hz because the mass of the PG sheet is approximately 0.003 g.”
BackgroundInfluentialBennewitz, R. (2024) · Nanoscience and technology · doi:10.1007/978-3-031-63065-1_1 · Cited by 2
Calibration of the lateral spring constant for a custom T-shaped atomic force microscopy probe
Yang, Z., Xu, R., Zhao, D., Li, Y., Yu, W. D., & Wang, J. (2025) · Review of Scientific Instruments · doi:10.1063/5.0249211 · Cited by 2
Influence of force-based crosstalk on the ‘wedge method’ in lateral force microscopy
Michal, G., Lü, C., & Tieu, A. K. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/5/055103 · Cited by 2
Theoretic and numerical analysis of diamagnetic levitation and its experimental verification
Ye, Z., Duan, Z., & Su, Y. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2075246 · Cited by 2
“0 m v z z y y x x 0 m z ⋅ ∂ ∂ μ χ = ⋅ ∂ ∂ + ∂ ∂ + ∂ ∂ μ χ = ∫∫∫ ∫∫∫ ) ( ) ( (11)”
BackgroundAtomic Force Microscopy: Lateral-Force Calibration and Force-Curve Analysis
Anderson, E. (2012) · Digital WPI · Cited by 2
Calibration of Normal and Lateral Forces in Cantilevers Used in Atomic Force Microscopy
Palacio, M. L. B., & Bhushan, B. (2011) · Springer eBooks · doi:10.1007/978-3-642-15283-2_4 · Cited by 2
“17 Schematics of (a) the tip-surface contact showing horizontal sliding of the tip in the compliance hysteresis method (Adapted from [61]), (b) lateral electrical nanobalance and movement of the platform (Dy) during the tip sliding [65], (c) Lorentz force induction technique [66], and (d) diamagnetic levitation spring…”
MethodNanoscale Friction: Measurement and Analysis
Chung, Y.-W. (2011) · CRC Press eBooks · doi:10.1201/b11211-8 · Cited by 2
High Speed Atomic Force Microscopy Techniques for the Efficient Study of Nanotribology
Bosse, J. L. (2012) · OpenCommons - UConn (University of Connecticut) · Cited by 2
Interfacial polarization-induced tribological behavior in MoS 2 /β-Te and G/β-Te heterostructures
Ru, G., Qi, W., Xue, K., Wang, M., & Liu, X. (2025) · Nanoscale · doi:10.1039/d4nr04930f · Cited by 1
Wang, Y., Huang, Z., Li, T., Zheng, C., Shao, Y., Yang, D., Lei, Y., Xu, Z., Zheng, Q. S., & Peng, D. (2026) · Fundamental Research · doi:10.1016/j.fmre.2025.12.026 · Cited by 1
On-Device Control of Electronic Friction
Yu, Z., Bian, J. H., Wang, J., Jiang, Z., Huang, X., Zhai, L., Lu, X., Liu, X., Zheng, Q., & Xu, Z. (2026) · Physical Review X · doi:10.1103/jlc2-qmr1 · Cited by 1
Kamide, T., Tatsubo, A., Twamley, J., & Takeda, K. (2026) · Analysis & Sensing · doi:10.1002/anse.70099 · Cited by 1
ANALYTICAL AND NUMERICAL ANALYSIS OF FORCE AND STIFFNESS IN A DIAMAGNETIC BEARING
Cansız, A., & Hasar, U. C. (2009) · Modern Physics Letters B · doi:10.1142/s0217984909020850 · Cited by 1
Instrumentation Issues of an AFM Based Nanorobotic System
Xie, H., Onal, C. D., Régnier, S., & Sitti, M. (2011) · Springer tracts in advanced robotics · doi:10.1007/978-3-642-20329-9_3 · Cited by 1
Calibration of Normal and Lateral Forces in Cantilevers Used in Atomic Force Microscopy
Palacio, M. L. B., & Bhushan, B. (2017) · Springer eBooks · doi:10.1007/978-3-319-51433-8_3 · Cited by 1
The Transition of Friction Coefficient on Graphene by the Microsphere Probe
Zhan, L., Peng, Y., Huang, Y. T., & Zou, K. (2023) · Tribology Letters · doi:10.1007/s11249-023-01716-5 · Cited by 1
“The lateral sensitivity coefficient of the microsphere probe was measured by the inverse magnetic levitation method [26], and the non-contact method was for the Multi 75 probe.”
MethodKashyap, V., Novo, N. G. D., & Pugno, N. M. (2025) · Tribology International · doi:10.1016/j.triboint.2025.110513 · Cited by 1
Diamagnetically Levitated and Trapped Graphite Mechanical Resonators
Wang, Y., Gage, A., Lee, J., & Feng, P. X. ‐. (2025) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems61431.2025.10918076 · Cited by 1
“Additionally, passive diamagnetic levitation has also been utilized in developing applications such as accelerometers [11], energy harvesters [12], and force sensors [13].”
Massive Transfer and Assembly of Microscale Superlubric Materials
Yang, D., Xue, M., Han, M., Wang, Y., Jiang, Z.-Q., Zheng, Q., & Peng, D. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c02336 · Cited by 1
Tribologische Mess- und Prüftechnik
Czichos, H., & Stürm, H. (2015) · Springer eBooks · doi:10.1007/978-3-8348-2236-9_8 · Cited by 2
Friction of MoO3 Nanoflakes on Graphite Surface with an Ace-like Intercalation Layer
Wei, D., Zhang, G., Lu, X., & Qiu, X. (2022) · Chemical Research in Chinese Universities · doi:10.1007/s40242-022-2050-9 · Cited by 1
Chow, T.-Y., Wong, P. L., & Liu, K. P. (2010) · Journal of Physics Conference Series · doi:10.1088/1742-6596/200/3/032013 · Cited by 1
Peng, Y., Yu, K., Xu, P., Huang, Y. T., Lang, H., & Ding, S. (2023) · Research Square · doi:10.21203/rs.3.rs-2477249/v1 · Cited by 1
Khare, H. S. (2024) · Library, Museums and Press - UDSpace (University of Delaware) · doi:10.58088/e9w8-xy78
Experimental Methods for the Calibration of Lateral Forces in Atomic Force Microscopy
Munz, M. (2009) · Nanoscience and technology · doi:10.1007/978-3-642-03535-7_9
Quantitative Measurement of Nano-scale Force using Atomic Force Microscopy
Chung, K. (2012) · 윤활학회지 · doi:10.9725/kstle.2012.28.2.062
“diamagnetic levitation 스프링을 이용한 방법[34] 등이 활용될 수 있다.”
Contact-free Two Dimensional Micro-displacement Actuation by Using Diamagnetic Graphite
Saito, R., Itatsu, K., Kanke, M., Ito, A., & Suzuki, H. (2010) · IEEJ Transactions on Industry Applications · doi:10.1541/ieejias.130.1221
Effect of Contact Stiffness on Lateral Force Calibration of Atomic Force Microscopy Cantilever
Tran, D. K., Jeon, K., & Chung, K. (2012) · 윤활학회지 · doi:10.9725/kstle-2012.28.6.289
“따라서, 수평방향 힘을 교정하기 위해서는 직접적인 힘 교정 방법이 유리한데, 대표적 으로 wedge 방법[17,18], magnetic levitation을 이용 하는 방법[19], pivot loading을 이용하는 방법[20] 등 이 있다.”
Lateral Force Calibration in Liquid Environment using Multiple Pivot Loading
Kim, L.-W., & Chung, K. (2013) · 윤활학회지 · doi:10.9725/kstle.2013.29.2.091
“이 와 같은 문제를 해결하기 위하여 직접적인 힘 교정 방 법이 많이 제시되고 있으며, 대표적으로 wedge 방법 [11,12], magnetic levitation을 이용하는 방법[13], pivot loading을 이용하는 방법[14] 등이 있다.”
Quantitative Lateral Force Calibration of V-shaped AFM Cantilever
Lee, H., Kim, K., Kim, H., Kang, B., & Chung, K. (2012) · 윤활학회지 · doi:10.9725/kstle-2012.28.5.203
“마찰력 측 정을 위한 교정방법으로 위에 제시된 방법들이 함께 활용될 수 있으며, 직접적인 교정 방법으로 wedge calibration 방법[11-13], magnetic levitation을 이용하 는 방법[14], pivot loading을 이용하는 방법 등도 제 시되고 있다[15,16].”
Self-citationMicromechanics of pseudo-single-asperity friction: effects of nanometer-scale roughness
Li, Q. (2008) · doi:10.7301/z0kw5dbn
Self-citationAFM with Higher Mode Oscillations and Higher Sensitivity
Tseytlin, Y. M. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-801999-3.00003-6
Pyrolytic Carbon: Applications of Diamagnetic Levitation in Metrology
Pinot, P., & Silvestri, Z. (2018) · Conference on Precision Electromagnetic Measurements · doi:10.1109/cpem.2018.8501041
“[10] have developed a diamagnetic lateral force calibrator composed of four NdFeB magnets and a diamagnetic pyrolytic graphite sheet to directly calibrate”
MethodSuperlubric Schottky Generator in Microscale with High Current Density and Ultralong LifePreprint
Huang, X., Xiang, X., Peng, D., Yang, F., Jiang, H., Wu, Z., Xu, Z., & Zheng, Q. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2009.04231
Modeling and Validation of Diamagnetic Rotor Levitated by Permanent MagneticsPreprint
Xu, Y., Zhang, Y., Zhou, J. H., & Jin, C. (2020) · Research Square · doi:10.21203/rs.3.rs-102581/v1
Шафорост, А. С., Воропаев, Е. В., Ачинович, С. Л., & Silin, R. A. (2021) · Health and Ecology Issues · doi:10.51523/2708-6011.2021-18-1-20
“Если же поверхность не гладкая, то, чтобы различить участки с различными коэффициентами трения и неоднородности рельефа, необходимо использовать второй проход в противоположном направлении [7].”
Butt, P. H.-J., & Kappl, D. M. (2018) · Wiley eBooks · doi:10.1002/9783527804351.ch2
(2018) · Wiley eBooks · doi:10.1002/9783527804351.refs
Volk, J., Radó, J., Baji, Z., & Erdélyi, R. (2022) · Nanomaterials · doi:10.3390/nano12234120
Pressure-Tuned Ideal P-Type Schottky ContactsPreprint
Xu, Z., Yu, Z., Huang, X., Bian, J., He, Y., Lu, X., & Zheng, Q. (2024) · Research Square · doi:10.21203/rs.3.rs-3999016/v1
“Stick–slip” fluctuations in local electrical conductivity maps on graphite surfaces: A revisit
Wang, H., Zhang, S., & Li, Q. (2024) · Applied Surface Science · doi:10.1016/j.apsusc.2024.160888
Self-citation
Metadata
- Authors
- Li, Q., Kim, K.-S., & Rydberg, A.
- Affiliations
- Brown University (US)
- ORCID
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2006-06-01
- Volume
- 77
- Issue
- 6
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2029314957
- Cited by
- 208
- References
- 18
- Citations by year
- 2026: 10 · 2025: 11 · 2024: 15 · 2023: 12 · 2022: 10 · 2021: 10 · 2020: 20 · 2019: 10 · 2018: 17 · 2017: 10 · 2016: 9 · 2015: 9 · 2014: 4 · 2013: 4 · 2012: 13
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- cc-by
- creativecommons.org/licenses/by/3.0/ (vor, 13 d)
- creativecommons.org/licenses/by/3.0/ (tdm, 13 d)
- Locations
- Review of Scientific Instruments (publishedVersion, cc-by)
- Funders
- Rice University
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Force Microscopy Techniques and Applications
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Physical Sciences › Engineering › Mechanical Engineering › Advanced Measurement and Metrology Techniques
- Keywords
- atomic force microscopy, diamagnetic levitation, wedge method, friction measurement, Nd-Fe-B permanent magnets, pyrolytic graphite
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.