The DOI matches its Crossref record; 73 of the 73 references it cites were found in a registry or an index.
Superconducting quantum interference device instruments and applications
Abstract
Superconducting quantum interference devices (SQUIDs) have been a key factor in the development and commercialization of ultrasensitive electric and magnetic measurement systems. In many cases, SQUID instrumentation offers the ability to make measurements where no other methodology is possible. We review the main aspects of designing, fabricating, and operating a number of SQUID measurement systems. While this article is not intended to be an exhaustive review on the principles of SQUID sensors and the underlying concepts behind the Josephson effect, a qualitative description of the operating principles of SQUID sensors and the properties of materials used to fabricate SQUID sensors is presented. The difference between low and high temperature SQUIDs and their suitability for specific applications is discussed. Although SQUID electronics have the capability to operate well above 1MHz, most applications tend to be at lower frequencies. Specific examples of input circuits and detection coil configuration for different applications and environments, along with expected performance, are described. In particular, anticipated signal strength, magnetic field environment (applied field and external noise), and cryogenic requirements are discussed. Finally, a variety of applications with specific examples in the areas of electromagnetic, material property, nondestructive test and evaluation, and geophysical and biomedical measurements are reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Possible highT c superconductivity in the Ba?La?Cu?O system
Bednorz, J. G., & M�ller, K. A. (1986) · Zeitschrift f�r Physik B Condensed Matter · doi:10.1007/bf01303701 · Cited by 14,319
Bardeen, J., Cooper, L. N., & Schrieffer, J. R. (1957) · Physical Review · doi:10.1103/physrev.108.1175 · Cited by 13,213
Possible new effects in superconductive tunnelling
Josephson, B. D. (1962) · Physics Letters · doi:10.1016/0031-9163(62)91369-0 · Cited by 4,130
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561
Progress in low temperature physics
(1957) · Nuclear Physics · doi:10.1016/0029-5582(57)90008-1 · Cited by 1,919
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
Rock Magnetism: Fundamentals and Frontiers
Dunlop, D., Özdemir, Ö., & Fuller, M. D. (1998) · Physics Today · doi:10.1063/1.882466 · Cited by 1,611
High-Tc superconducting materials for electric power applications
Larbalestier, D., Gurevich, A., Feldmann, D. M., & Polyanskii, A. (2001) · Nature · doi:10.1038/35104654 · Cited by 1,315
Inductance Calculations Working Formulas and Tables
Snyder, J. N., & Grover, F. C. (1964) · Mathematics of Computation · doi:10.2307/2003443 · Cited by 1,309
Ein neuer Effekt bei Eintritt der Supraleitf�higkeit
Meissner, W., & Ochsenfeld, R. (1933) · Die Naturwissenschaften · doi:10.1007/bf01504252 · Cited by 1,219
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Materials challenges and opportunities for quantum computing hardware
de Leon, N. P., Itoh, K. M., Kim, D., Mehta, K. K., Northup, T. E., Paik, H., Palmer, B. S., Samarth, N., Sangtawesin, S., & Steuerman, D. W. (2021) · Science · doi:10.1126/science.abb2823 · Cited by 710
Tutorial: a beginner’s guide to interpreting magnetic susceptibility data with the Curie-Weiss law
Mugiraneza, S., & Hallas, A. M. (2022) · Communications Physics · doi:10.1038/s42005-022-00853-y · Cited by 555
Subpicotesla atomic magnetometry with a microfabricated vapour cell
Shah, V., Knappe, S., Schwindt, P. D. D., & Kitching, J. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.201 · Cited by 415
McGrath, T., Bagci, I. E., Wang, Z. M., Roedig, U., & Young, R. J. (2019) · Applied Physics Reviews · doi:10.1063/1.5079407 · Cited by 353
Broadband magnetometry and temperature sensing with a light-trapping diamond waveguide
Clevenson, H., Trusheim, M. E., Teale, C., Schröder, T., Braje, D., & Englund, D. (2015) · Nature Physics · doi:10.1038/nphys3291 · Cited by 296
Spin-exchange relaxation-free magnetometry using elliptically polarized light
Shah, V., & Romalis, M. V. (2009) · Physical Review A · doi:10.1103/physreva.80.013416 · Cited by 273
Magnetoresistive Sensor Development Roadmap (Non-Recording Applications)
Zheng, C., Zhu, K., Cardoso de Freitas, S., Chang, J.-Y., Davies, J. E., Eames, P., Freitas, P. P., Kazakova, O., Kim, C., Leung, C.-W., et al. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2896036 · Cited by 268
Calibration of Room Temperature Magnetic Sensor Array for Biomagnetic Measurement
Adachi, Y., Oyama, D., Terazono, Y., Hayashi, T., Shibuya, T., & Kawabata, S. (2019) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2019.2895355 · Cited by 39
Swain, P. P., Sengottuvel, S., Patel, R., Mani, A., & Gireesan, K. (2020) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101664 · Cited by 21
Metadata
- Authors
- Fagaly, R. L.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2006-10-01
- Volume
- 77
- Issue
- 10
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2087491525
- Cited by
- 594
- References
- 73
- FWCI
- 11.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.