The DOI matches its Crossref record; 73 of the 73 references it cites were found in a registry or an index.
Superconducting quantum interference device instruments and applications
Abstract
Superconducting quantum interference devices (SQUIDs) have been a key factor in the development and commercialization of ultrasensitive electric and magnetic measurement systems. In many cases, SQUID instrumentation offers the ability to make measurements where no other methodology is possible. We review the main aspects of designing, fabricating, and operating a number of SQUID measurement systems. While this article is not intended to be an exhaustive review on the principles of SQUID sensors and the underlying concepts behind the Josephson effect, a qualitative description of the operating principles of SQUID sensors and the properties of materials used to fabricate SQUID sensors is presented. The difference between low and high temperature SQUIDs and their suitability for specific applications is discussed. Although SQUID electronics have the capability to operate well above 1MHz, most applications tend to be at lower frequencies. Specific examples of input circuits and detection coil configuration for different applications and environments, along with expected performance, are described. In particular, anticipated signal strength, magnetic field environment (applied field and external noise), and cryogenic requirements are discussed. Finally, a variety of applications with specific examples in the areas of electromagnetic, material property, nondestructive test and evaluation, and geophysical and biomedical measurements are reviewed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Possible highT c superconductivity in the Ba?La?Cu?O system
Bednorz, J. G., & M�ller, K. A. (1986) · Zeitschrift f�r Physik B Condensed Matter · doi:10.1007/bf01303701 · Cited by 14,319
Bardeen, J., Cooper, L. N., & Schrieffer, J. R. (1957) · Physical Review · doi:10.1103/physrev.108.1175 · Cited by 13,213
Possible new effects in superconductive tunnelling
Josephson, B. D. (1962) · Physics Letters · doi:10.1016/0031-9163(62)91369-0 · Cited by 4,130
Van Veen, B. D., Van Drongelen, W., Yuchtman, M., & Suzuki, A. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.623056 · Cited by 2,561
Progress in low temperature physics
(1957) · Nuclear Physics · doi:10.1016/0029-5582(57)90008-1 · Cited by 1,919
Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem
Sarvas, J. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/1/004 · Cited by 1,843
Rock Magnetism: Fundamentals and Frontiers
Dunlop, D., Özdemir, Ö., & Fuller, M. D. (1998) · Physics Today · doi:10.1063/1.882466 · Cited by 1,611
High-Tc superconducting materials for electric power applications
Larbalestier, D., Gurevich, A., Feldmann, D. M., & Polyanskii, A. (2001) · Nature · doi:10.1038/35104654 · Cited by 1,315
Inductance Calculations Working Formulas and Tables
Snyder, J. N., & Grover, F. C. (1964) · Mathematics of Computation · doi:10.2307/2003443 · Cited by 1,309
Ein neuer Effekt bei Eintritt der Supraleitf�higkeit
Meissner, W., & Ochsenfeld, R. (1933) · Die Naturwissenschaften · doi:10.1007/bf01504252 · Cited by 1,219
High-Tc superconducting materials for electric power applications
Larbalestier, D., Gurevich, A., Feldmann, D. M., & Polyanskii, A. (2010) · Materials for Sustainable Energy · doi:10.1142/9789814317665_0046 · Cited by 924
Advances in Cryogenic Engineering: Part A
(1996) · A Cryogenic Engineering Conference Publication · doi:10.1007/978-1-4613-0373-2 · Cited by 885
Principles of Superconductive Devices and Circuits
Campbell, A. M. (1982) · Physics Bulletin · doi:10.1088/0031-9112/33/2/040 · Cited by 868
dc SQUID: Noise and optimization
Tesche, C. D., & Clarke, J. (1977) · Journal of Low Temperature Physics · doi:10.1007/bf00655097 · Cited by 691
Magnetic Sensors and Magnetometers
(ed), P. R. (2002) · Measurement Science and Technology · doi:10.1088/0957-0233/13/4/707 · Cited by 663
Experimental Principles and Methods Below 1 K
Lounasmaa, O. V., & Parks, R. D. (1975) · Physics Today · doi:10.1063/1.3069146 · Cited by 498
(1989) · Springer eBooks · doi:10.1007/978-1-4613-0581-1 · Cited by 452
First Results from a Superconductive Detector for Moving Magnetic Monopoles
Cabrera, B. (1982) · Physical Review Letters · doi:10.1103/physrevlett.48.1378 · Cited by 430
High-transition-temperature superconducting quantum interference devices
Koelle, D., Kleiner, R., Ludwig, F., Dantsker, E., & Clarke, J. (1999) · Reviews of Modern Physics · doi:10.1103/revmodphys.71.631 · Cited by 396
Foundations of Applied Superconductivity
Orlando, T. P., Delin, K. A., & Lobb, C. J. (1991) · Physics Today · doi:10.1063/1.2810145 · Cited by 394
Zimmerman, J. E., Thiene, P., & Harding, J. T. (1970) · Journal of Applied Physics · doi:10.1063/1.1659074 · Cited by 394
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Magnetocardiograms taken inside a shielded room with a superconducting point-contact magnetometer
Cohen, D., Edelsack, E. A., & Zimmerman, J. E. (1970) · Applied Physics Letters · doi:10.1063/1.1653195 · Cited by 361
Giffard, R. P., Webb, R. A., & Wheatley, J. C. (1972) · Journal of Low Temperature Physics · doi:10.1007/bf00644085 · Cited by 288
(2004) · Springer eBooks · doi:10.1007/978-3-642-18914-2 · Cited by 286
First Results from the Cryogenic Dark Matter Search in the Soudan Underground Laboratory
Akerib, D. S., Alvaro-Dean, J., Armel-Funkhouser, M. S., Attisha, M. J., Baudis, L., Bauer, D. A., Beaty, J., Brink, P. L., Bunker, R., Burke, S. P., et al. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.211301 · Cited by 266
Microwave cavity searches for dark-matter axions
Bradley, R., Clarke, J., Kinion, D., Rosenberg, L. J., van Bibber, K., Matsuki, S., Mück, M., & Sikivie, P. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.777 · Cited by 259
Ultra-low-noise tunnel junction dc SQUID with a tightly coupled planar input coil
Ketchen, M. B., & Jaycox, J. M. (1982) · Applied Physics Letters · doi:10.1063/1.93210 · Cited by 248
Romani, G. L., Williamson, S. J., & Kaufman, L. (1982) · Review of Scientific Instruments · doi:10.1063/1.1136907 · Cited by 235
Drung, D., Cantor, R., Peters, M., Scheer, H. J., & Koch, H. (1990) · Applied Physics Letters · doi:10.1063/1.103650 · Cited by 223
A Low Temperature Transfer of ALH84001 from Mars to Earth
Weiss, B. P., Kirschvink, J. L., Baudenbacher, F. J., Vali, H., Peters, N. T., Macdonald, F. A., & Wikswo, J. P. (2000) · Science · doi:10.1126/science.290.5492.791 · Cited by 218
The SQUID Handbook: Fundamentals and Technology of SQUIDs and SQUID Systems
Clarke, J. L., & Braginski, A. I. (2004) · Cited by 215
Advanced superconducting gradiometer/Magnetometer arrays and a novel signal processing technique
Wynn, W., Frahm, C., Carroll, P., Clark, R., Wellhoner, J., & Wynn, M. (1975) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1975.1058672 · Cited by 205
Smoking Impairs Long-Term Dust Clearance from the Lung
Cohen, D., Arai, S. F., & Brain, J. D. (1979) · Science · doi:10.1126/science.432655 · Cited by 203
Timmerhaus, K. D., & Flynn, T. M. (1989) · Springer eBooks · doi:10.1007/978-1-4684-8756-5 · Cited by 201
Mucociliary and long-term particle clearance in the airways of healthy nonsmoker subjects
Möller, W., Häußinger, K., Winkler-Heil, R., Stahlhofen, W., Meyer, T., Hofmann, W., & Heyder, J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00970.2003 · Cited by 189
Local linear estimators for the bioelectromagnetic inverse problem
Greenblatt, R. E., Ossadtchi, A., & Pflieger, M. E. (2005) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2005.853201 · Cited by 163
SQUIDs for nondestructive evaluation
Jenks, W. G., Sadeghi, S. H. H., & Wikswo, J. P. (1997) · Journal of Physics D Applied Physics · doi:10.1088/0022-3727/30/3/002 · Cited by 152
High- T c and low- T c dc SQUID electronics
Drung, D. (2003) · Superconductor Science and Technology · doi:10.1088/0953-2048/16/12/002 · Cited by 146
Advances in Cryogenic Engineering
Collective (1988) · Advances in cryogenic engineering · doi:10.1007/978-1-4613-9874-5 · Cited by 134
Superconducting quantum interference device as a near-quantum-limited amplifier at 0.5 GHz
Mück, M., Kycia, J. B., & Clarke, J. L. (2001) · Applied Physics Letters · doi:10.1063/1.1347384 · Cited by 118
Large-area low-noise seven-channel dc SQUID magnetometer for brain research
Knuutila, J., Ahlfors, S. P., Ahonen, A. I., Hallstrom, J. K., Kajola, M., Lounasmaa, O. V., Vilkman, V., & Tesche, C. D. (1987) · Review of Scientific Instruments · doi:10.1063/1.1139478 · Cited by 116
Squid Gradiometers in Real Environments
Vrba, J. (1996) · Springer eBooks · doi:10.1007/978-94-011-5674-5_3 · Cited by 110
Principles of quasistatic magnetic shielding with cylindrical and spherical shields
Hoburg, J. F. (1995) · IEEE Transactions on Electromagnetic Compatibility · doi:10.1109/15.477342 · Cited by 109
Fong, L. E., Holzer, J. R., McBride, K. K., Lima, E. A., Baudenbacher, F. J., & Radparvar, M. (2005) · Review of Scientific Instruments · doi:10.1063/1.1884025 · Cited by 81
Large-volume conventional magnetic shields
Cohen, D. (1970) · Revue de Physique Appliquée · doi:10.1051/rphysap:019700050105300 · Cited by 78
Hilbert, C., Clarke, J. L., Sleator, T., & Hahn, E. L. (1985) · Applied Physics Letters · doi:10.1063/1.96042 · Cited by 60
Möller, W. (2001) · Experimental Lung Research · doi:10.1080/019021401753181827 · Cited by 59
Spatiotemporal properties of the fetal magnetocardiogram
Wakai, R. T., Wang, M., & Martin, C. B. (1994) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(94)70280-2 · Cited by 55
SQUID Applications to Geophysics
Weinstock, H., & Overton, W. C. (1981) · Society of Exploration Geophysicists eBooks · doi:10.1190/1.9781560802518 · Cited by 54
Okada, Y., Pratt, K., Atwood, C., Mascarenas, A., Reineman, R., Nurminen, J., & Paulson, D. (2006) · Review of Scientific Instruments · doi:10.1063/1.2168672 · Cited by 53
Biomagnetic susceptometer with SQUID instrumentation
Paulson, D. N., Fagaly, R. L., Toussaint, R. M., & Fischer, R. (1991) · IEEE Transactions on Magnetics · doi:10.1109/20.133904 · Cited by 48
Self-citationVisualization of a moving quadrupole with magnetic measurements of peripheral nerve action fields
Hashimoto, I., MASHIKO, T., Mizuta, T., Imada, T., Iwase, K., & Okazaki, H. (1994) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(94)90154-6 · Cited by 44
A New Generation of the HTS Multilayer DC-SQUID Magnetometers and Gradiometers
Faley, M. I., Poppe, U., Urban, K. W., Paulson, D. N., & Fagaly, R. L. (2006) · Journal of Physics Conference Series · doi:10.1088/1742-6596/43/1/292 · Cited by 43
Self-citationSuperconducting magnetic shields for SQUID applications
Claycomb, J. R., & Miller, J. H. (1999) · Review of Scientific Instruments · doi:10.1063/1.1150113 · Cited by 42
Wikswo, J. P., & Roth, B. J. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90135-6 · Cited by 40
Technique for measuring the ac susceptibility of portions of the human body or other large objects
Bastuscheck, C. M., & Williamson, S. J. (1985) · Journal of Applied Physics · doi:10.1063/1.335609 · Cited by 39
Performance of a resonant input SQUID amplifier system
Simmonds, M., Fertig, W. A., & Giffard, R. P. (1979) · IEEE Transactions on Magnetics · doi:10.1109/tmag.1979.1060155 · Cited by 37
Optimization of SQUID differential magnetometers
Wikswo, J. P. (1978) · AIP conference proceedings · doi:10.1063/1.31331 · Cited by 35
Behaviour of magnetic micro-particles in the human lung
STAHLHOFEN, W., & M√∂ller, W. (1993) · Radiation and Environmental Biophysics · doi:10.1007/bf01209772 · Cited by 35
Sarwinski, R. E. (1977) · Cryogenics · doi:10.1016/0011-2275(77)90223-5 · Cited by 34
[Neurology and clinical neurophysiology].
Jj, Z., & Madoz, P. (1986) · PubMed · Cited by 32
Aluminum shielded room for biomagnetic measurements
Stroink, G., Blackford, B. L., Brown, B., & Horáček, M. (1981) · Review of Scientific Instruments · doi:10.1063/1.1136612 · Cited by 31
Baudenbacher, F. J., Peters, N., Baudenbacher, P., & Wikswo, J. P. (2002) · Physica C Superconductivity · doi:10.1016/s0921-4534(01)01134-0 · Cited by 28
High-Resolution Measurements of Biomagnetic Fields
Wikswo, J. P. (1988) · Advances in cryogenic engineering · doi:10.1007/978-1-4613-9874-5_13 · Cited by 25
Instrumentation for Clinical Applications of Neuromagnetism
Buchanan, D. S., Paulson, D. N., & Williamson, S. J. (1988) · Advances in cryogenic engineering · doi:10.1007/978-1-4613-9874-5_12 · Cited by 24
Magnetic background noise cancellation in real-world environments
Wöltgens, P., & Koch, R. H. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150490 · Cited by 23
Improved instrumentation for measuring the magnetic field of cellular action currents
Wikswo, J. P. (1982) · Review of Scientific Instruments · doi:10.1063/1.1136908 · Cited by 23
High-Resolution Magnetic Imaging: Cellular Action Currents and Other Applications
Wikswo, J. P. (1996) · Springer eBooks · doi:10.1007/978-94-011-5674-5_7 · Cited by 23
Macrophage functions measured by magnetic microparticles in vivo and in vitro
Möller, W., Kreyling, W. G., Kohlhäufl, M. J., Häussinger, K., & Heyder, J. (2001) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(00)01261-0 · Cited by 19
Mück, M., & Clarke, J. L. (2001) · Review of Scientific Instruments · doi:10.1063/1.1389498 · Cited by 9
Biological Imaging and Sensing
Furukawa, T. (2004) · Biological and medical physics series · doi:10.1007/978-3-662-06081-0 · Cited by 9
Lewis, P. S., & George, J. S. (1990) · IEEE Potentials · doi:10.1109/45.65860 · Cited by 8
Cited by
Degen, C. L., Reinhard, F., & Cappellaro, P. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.035002 · Cited by 4,045
Materials challenges and opportunities for quantum computing hardware
de Leon, N. P., Itoh, K. M., Kim, D., Mehta, K. K., Northup, T. E., Paik, H., Palmer, B. S., Samarth, N., Sangtawesin, S., & Steuerman, D. W. (2021) · Science · doi:10.1126/science.abb2823 · Cited by 710
Tutorial: a beginner’s guide to interpreting magnetic susceptibility data with the Curie-Weiss law
Mugiraneza, S., & Hallas, A. M. (2022) · Communications Physics · doi:10.1038/s42005-022-00853-y · Cited by 555
Subpicotesla atomic magnetometry with a microfabricated vapour cell
Shah, V., Knappe, S., Schwindt, P. D. D., & Kitching, J. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.201 · Cited by 415
McGrath, T., Bagci, I. E., Wang, Z. M., Roedig, U., & Young, R. J. (2019) · Applied Physics Reviews · doi:10.1063/1.5079407 · Cited by 353
Metadata
- Authors
- Fagaly, R. L.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2006-10-01
- Volume
- 77
- Issue
- 10
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2087491525
- Cited by
- 594
- References
- 73
- FWCI
- 11.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.