Magnetic resonance–coupled fluorescence tomography scanner for molecular imaging of tissue
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
A multichannel spectrally resolved optical tomography system to image molecular targets in small animals from within a clinical MRI is described. Long source/detector fibers operate in contact mode and couple light from the tissue surface in the magnet bore to 16 spectrometers, each containing two optical gratings optimized for the near infrared wavelength range. High sensitivity, cooled charge coupled devices connected to each spectrograph provide detection of the spectrally resolved signal, with exposure times that are automated for acquisition at each fiber. The design allows spectral fitting of the remission light, thereby separating the fluorescence signal from the nonspecific background, which improves the accuracy and sensitivity when imaging low fluorophore concentrations. Images of fluorescence yield are recovered using a nonlinear reconstruction approach based on the diffusion approximation of photon propagation in tissue. The tissue morphology derived from the MR images serves as an imaging template to guide the optical reconstruction algorithm. Sensitivity studies show that recovered values of indocyanine green fluorescence yield are linear to concentrations of 1nM in a 70mm diameter homogeneous phantom, and detection is feasible to near 10pM. Phantom data also demonstrate imaging capabilities of imperfect fluorophore uptake in tissue volumes of clinically relevant sizes. A unique rodent MR coil provides optical fiber access for simultaneous optical and MR data acquisition of small animals. A pilot murine study using an orthotopic glioma tumor model demonstrates optical-MRI imaging of an epidermal growth factor receptor targeted fluorescent probe in vivo.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827
A submillimeter resolution fluorescence molecular imaging system for small animal imaging
Graves, E. E., Ripoll, J., Weissleder, R., & Ntziachristos, V. (2003) · Medical Physics · doi:10.1118/1.1568977 · Cited by 390
Ntziachristos, V., Schellenberger, E. A., Ripoll, J., Yessayan, D., Graves, E., Bogdanov, A., Josephson, L., & Weissleder, R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0401137101 · Cited by 348
Choe, R., Corlu, A., Lee, K., Durduran, T., Konecky, S. D., Grosicka‐Koptyra, M., Arridge, S. R., Czerniecki, B. J., Fraker, D. L., DeMichele, A., et al. (2005) · Medical Physics · doi:10.1118/1.1869612 · Cited by 295
Diffuse optical tomography with spectral constraints and wavelength optimization
Corlu, A., Choe, R., Durduran, T., Lee, K., Schweiger, M. J., Arridge, S., Hillman, E. M. C., & Yodh, A. G. (2005) · Applied Optics · doi:10.1364/ao.44.002082 · Cited by 234
Fluorescence Molecular Imaging of Small Animal Tumor Models
Graves, E., Weissleder, R., & Ntziachristos, V. (2004) · Current Molecular Medicine · doi:10.2174/1566524043360555 · Cited by 213
Uniqueness and wavelength optimization in continuous-wave multispectral diffuse optical tomography
Corlu, A., Durduran, T., Choe, R., Schweiger, M. J., Hillman, E. M. C., Arridge, S., & Yodh, A. G. (2003) · Optics Letters · doi:10.1364/ol.28.002339 · Cited by 189
Experimental Fluorescence Tomography of Tissues With Noncontact Measurements
Schulz, R. B., Ripoll, J., & Ntziachristos, V. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825633 · Cited by 174
Time-dependent whole-body fluorescence tomography of probe bio-distributions in mice
Patwardhan, S. V., Bloch, S. R., Achilefu, S., & Culver, J. P. (2005) · Optics Express · doi:10.1364/opex.13.002564 · Cited by 168
Diffuse optical tomography with a priori anatomical information
Murat Guven, A., Yazıcı, B., Intes, X., & Chance, B. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/12/008 · Cited by 166
Near-Infrared Characterization of Breast Tumors In Vivo using Spectrally-Constrained Reconstruction
Srinivasan, S., Pogue, B. W., Brooksby, B. A., et al. (2005) · Technology in Cancer Research & Treatment · doi:10.1177/153303460500400505 · Cited by 117
Self-citationLi, A., Zhang, Q., Culver, J. P., Miller, E. L., & Boas, D. A. (2004) · Optics Letters · doi:10.1364/ol.29.000256 · Cited by 117
Fluorescent protein tomography scanner for small animal imaging
Zacharakis, G., Ripoll, J., Weissleder, R., & Ntziachristos, V. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.843254 · Cited by 104
Diagnostic imaging of breast cancer using fluorescence-enhanced optical tomography: phantom studies
Godavarty, A., Thompson, A. B., Roy, R., Gurfinkel, M., Eppstein, M. J., Zhang, C., & Sevick-Muraca, E. M. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1691027 · Cited by 93
Noncontact optical imaging in mice with full angular coverage and automatic surface extraction
Meyer, H., Garofalakis, A., Zacharakis, G., Psycharakis, S. E., Mamalaki, C., Kioussis, D., Economou, E. N., Ntziachristos, V., & Ripoll, J. (2007) · Applied Optics · doi:10.1364/ao.46.003617 · Cited by 80
Srinivasan, S., Pogue, B. W., Jiang, S., Dehghani, H., Kogel, C. A., Soho, S. K., Gibson, J. J., Tosteson, T. D., Poplack, S. P., & Paulsen, K. D. (2006) · Academic Radiology · doi:10.1016/j.acra.2005.10.002 · Cited by 76
Self-citationValidation of in vivo fluorochrome concentrations measured using fluorescence molecular tomography
Graves, E. E., Yessayan, D., Turner, G. M., et al. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1993427 · Cited by 49
Cited by
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Molecular Imaging by Means of Multispectral Optoacoustic Tomography (MSOT)
Ntziachristos, V., & Razansky, D. (2010) · Chemical Reviews · doi:10.1021/cr9002566 · Cited by 776
Pre-clinical whole-body fluorescence imaging: Review of instruments, methods and applications
Leblond, F., Davis, S. C., Valdés, P. A., & Pogue, B. W. (2010) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/j.jphotobiol.2009.11.007 · Cited by 593
Self-citationAle, A., Ermolayev, V., Herzog, E., Cohrs, C., de Angelis, M. H., & Ntziachristos, V. (2012) · Nature Methods · doi:10.1038/nmeth.2014 · Cited by 276
Darne, C., Lu, Y., & Sevick-Muraca, E. M. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/1/r1 · Cited by 199
Metadata
- Authors
- Davis, S. C., Pogue, B. W., Springett, R., Leussler, C., Mazurkewitz, P., Tuttle, S. B., Gibbs-Strauss, S. L., Jiang, S. S., Dehghani, H., & Paulsen, K. D.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2008-06-01
- Volume
- 79
- Issue
- 6
- Pages
- 064302-064302
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2086018477
- Cited by
- 171
- References
- 17
- FWCI
- 15.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.