The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
A submillimeter resolution fluorescence molecular imaging system for small animal imaging
Abstract
Most current imaging systems developed for tomographic investigations of intact tissues using diffuse photons suffer from a limited number of sources and detectors. In this paper we describe the construction and evaluation of a large dataset, low noise tomographic system for fluorescence imaging in small animals. The system consists of a parallel plate-imaging chamber and a lens coupled CCD camera, which enables conventional planar imaging as well as fluorescence tomography. The planar imaging data are used to guide the acquisition of a Fluorescence Molecular Tomography (FMT) dataset containing more than 106 measurements, and to superimpose anatomical features with tomographic results for improved visual representation. Experimental measurements exhibited good agreement with the diffusion theory models used to predict light propagation within the chamber. Tests of the instrument's capacity to quantitatively reconstruct fluorochrome distributions in three dimensions showed less than 5% errors between actual fluorochrome concentrations and FMT findings, and suggested a detection threshold of approximately 100 femptomoles for small localized objects. Experiments to assess the instrument's spatial resolution demonstrated the ability of the system to resolve objects placed at clear distances of less than 1 mm. This is a significant resolution increase over previously developed systems for animal imaging, and is primarily due to the large dataset employed and the use of inversion methods. Finally, the in vivo imaging capacity is showcased. It is expected that the large dataset collected can enable superior imaging of molecular probes in vivo and improve quantification of fluorescence signatures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Computerized Tomographic Imaging
Kak, A. C., & Slaney, M. (2001) · doi:10.1137/1.9780898719277 · Cited by 5,809
Molecular Beacons: Probes that Fluoresce upon Hybridization
Tyagi, S., & Kramer, F. R. (1996) · Nature Biotechnology · doi:10.1038/nbt0396-303 · Cited by 4,155
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
In vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591
Self-citationFluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827
Self-citationConcurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793
Self-citationImaging the body with diffuse optical tomography
Boas, D. A., Brooks, D. H., Miller, E. L., DiMarzio, C. A., Kilmer, M., Gaudette, R. J., & Zhang, Q. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962278 · Cited by 718
Receptor-targeted optical imaging of tumors with near-infrared fluorescent ligands
Becker, A., Hessenius, C., Licha, K., Ebert, B., Sukowski, U., Semmler, W., Wiedenmann, B., & Grötzinger, C. (2001) · Nature Biotechnology · doi:10.1038/86707 · Cited by 518
Ntziachristos, V., & Weissleder, R. (2001) · Optics Letters · doi:10.1364/ol.26.000893 · Cited by 475
Self-citationImaging biochemistry inside cells
Wouters, F. S., Verveer, P. J., & Bastiaens, P. I. H. (2001) · Trends in Cell Biology · doi:10.1016/s0962-8924(01)01982-1 · Cited by 395
Cited by
Looking and listening to light: the evolution of whole-body photonic imaging
Ntziachristos, V., Ripoll, J., Wang, L. V., & Weissleder, R. (2005) · Nature Biotechnology · doi:10.1038/nbt1074 · Cited by 1,557
Self-citationSharma, P., Brown, S., Walter, G., Santra, S., & Moudgil, B. (2006) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2006.05.026 · Cited by 755
FLUORESCENCE MOLECULAR IMAGING
Ntziachristos, V. (2006) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.8.061505.095831 · Cited by 731
Self-citationPre-clinical whole-body fluorescence imaging: Review of instruments, methods and applications
Leblond, F., Davis, S. C., Valdés, P. A., & Pogue, B. W. (2010) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/j.jphotobiol.2009.11.007 · Cited by 593
Noninvasive Imaging of Nanomedicines and Nanotheranostics: Principles, Progress, and Prospects
Kunjachan, S., Ehling, J., Storm, G., Kiessling, F., & Lammers, T. (2015) · Chemical Reviews · doi:10.1021/cr500314d · Cited by 480
Metadata
- Authors
- Graves, E. E., Ripoll, J., Weissleder, R., & Ntziachristos, V.
- Venue
- Medical Physics
- Publisher
- Wiley
- Published
- 2003-04-22
- Volume
- 30
- Issue
- 5
- Pages
- 901-911
- ISSN
- 0094-2405 (ISSN-L)
- OpenAlex
- W2043649486
- Cited by
- 390
- References
- 23
- FWCI
- 25.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A submillimeter resolution fluorescence molecular imaging system for small animal imaging. https://app.cochat.ai/papers/10.1118/1.1568977
- The paper
- Graves, E. E., Ripoll, J., Weissleder, R., & Ntziachristos, V. (2003). A submillimeter resolution fluorescence molecular imaging system for small animal imaging. Medical Physics. https://doi.org/10.1118/1.1568977
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.