Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 390

The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.

A submillimeter resolution fluorescence molecular imaging system for small animal imaging

Graves, Edward E., Ripoll, Jorge, Weissleder, Ralph, Ntziachristos, Vasilis·2003·Medical Physics

Abstract

Most current imaging systems developed for tomographic investigations of intact tissues using diffuse photons suffer from a limited number of sources and detectors. In this paper we describe the construction and evaluation of a large dataset, low noise tomographic system for fluorescence imaging in small animals. The system consists of a parallel plate-imaging chamber and a lens coupled CCD camera, which enables conventional planar imaging as well as fluorescence tomography. The planar imaging data are used to guide the acquisition of a Fluorescence Molecular Tomography (FMT) dataset containing more than 106 measurements, and to superimpose anatomical features with tomographic results for improved visual representation. Experimental measurements exhibited good agreement with the diffusion theory models used to predict light propagation within the chamber. Tests of the instrument's capacity to quantitatively reconstruct fluorochrome distributions in three dimensions showed less than 5% errors between actual fluorochrome concentrations and FMT findings, and suggested a detection threshold of approximately 100 femptomoles for small localized objects. Experiments to assess the instrument's spatial resolution demonstrated the ability of the system to resolve objects placed at clear distances of less than 1 mm. This is a significant resolution increase over previously developed systems for animal imaging, and is primarily due to the large dataset employed and the use of inversion methods. Finally, the in vivo imaging capacity is showcased. It is expected that the large dataset collected can enable superior imaging of molecular probes in vivo and improve quantification of fluorescence signatures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1118/1.1568977

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 23 references

Cited by

See all 390

Metadata

Authors
Graves, E. E., Ripoll, J., Weissleder, R., & Ntziachristos, V.
Venue
Medical Physics
Publisher
Wiley
Published
2003-04-22
Volume
30
Issue
5
Pages
901-911
ISSN
0094-2405 (ISSN-L)
OpenAlex
W2043649486
Cited by
390
References
23
FWCI
25.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A submillimeter resolution fluorescence molecular imaging system for small animal imaging. https://app.cochat.ai/papers/10.1118/1.1568977
The paper
Graves, E. E., Ripoll, J., Weissleder, R., & Ntziachristos, V. (2003). A submillimeter resolution fluorescence molecular imaging system for small animal imaging. Medical Physics. https://doi.org/10.1118/1.1568977

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.