The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Compressive ghost imaging
Open accessAbstract
We describe an advanced image reconstruction algorithm for pseudothermal ghost imaging, reducing the number of measurements required for image recovery by an order of magnitude. The algorithm is based on compressed sensing, a technique that enables the reconstruction of an N-pixel image from much less than N measurements. We demonstrate the algorithm using experimental data from a pseudothermal ghost-imaging setup. The algorithm can be applied to data taken from past pseudothermal ghost-imaging experiments, improving the reconstruction’s quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Single-pixel imaging via compressive sampling
Duarte, M. F., Davenport, M. A., Takhar, D., Laska, J. N., Sun, T., Kelly, K. F., & Baraniuk, R. G. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914730 · Cited by 3,575
Figueiredo, M. A. T., Nowak, R. D., & Wright, S. J. (2007) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2007.910281 · Cited by 3,524
Optical imaging by means of two-photon quantum entanglement
Pittman, T. B., Shih, Y. H., Strekalov, D. V., & Sergienko, A. V. (1995) · Physical Review A · doi:10.1103/physreva.52.r3429 · Cited by 2,142
Shapiro, J. H. (2008) · Physical Review A · doi:10.1103/physreva.78.061802 · Cited by 1,531
“Two-Photon” Coincidence Imaging with a Classical Source
Bennink, R. S., Bentley, S. J., & Boyd, R. W. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.113601 · Cited by 1,113
Imaging via Compressive Sampling
Romberg, J. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914729 · Cited by 1,014
Two-Photon Imaging with Thermal Light
Valencia, A., Scarcelli, G., D’Angelo, M., & Shih, Y. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.063601 · Cited by 838
A single-pixel terahertz imaging system based on compressed sensing
Chan, W. L., Charan, K., Takhar, D., Kelly, K. F., Baraniuk, R. G., & Mittleman, D. M. (2008) · Applied Physics Letters · doi:10.1063/1.2989126 · Cited by 803
Cited by
On the use of deep learning for computational imaging
Barbastathis, G., Ozcan, A., & Situ, G. (2019) · Optica · doi:10.1364/optica.6.000921 · Cited by 869
Single-pixel imaging by means of Fourier spectrum acquisition
Zhang, Z., Ma, X., & Zhong, J. (2015) · Nature Communications · doi:10.1038/ncomms7225 · Cited by 791
Single-pixel imaging 12 years on: a review
Gibson, G. M., Johnson, S. D., & Padgett, M. J. (2020) · Optics Express · doi:10.1364/oe.403195 · Cited by 645
Ghost imaging: from quantum to classical to computational
Erkmen, B. I., & Shapiro, J. H. (2010) · Advances in Optics and Photonics · doi:10.1364/aop.2.000405 · Cited by 483
Deep-learning-based ghost imaging
Lyu, M., Wang, W., Wang, H., Wang, H., Li, G., Chen, N., & Situ, G. (2017) · Scientific Reports · doi:10.1038/s41598-017-18171-7 · Cited by 449
Shapiro, J. H., & Boyd, R. W. (2012) · Quantum Information Processing · doi:10.1007/s11128-011-0356-5 · Cited by 429
Compressive fluorescence microscopy for biological and hyperspectral imaging
Studer, V., Bobin, J., Chahid, M., Mousavi, H. S., Candes, E., & Dahan, M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1119511109 · Cited by 411
Far-field super-resolution ghost imaging with a deep neural network constraint
Wang, F., Wang, C., Chen, M., Gong, W., Zhang, Y., Han, S., & Situ, G. (2022) · Light: Science & Applications · doi:10.1038/s41377-021-00680-w · Cited by 400
Ghost imaging lidar via sparsity constraints
Zhao, C., Gong, W., Chen, M., Li, E., Wang, H., Xu, W., & Han, S. (2012) · Applied Physics Letters · doi:10.1063/1.4757874 · Cited by 369
Experimental X-Ray Ghost Imaging
Pelliccia, D., Rack, A., Scheel, M., Cantelli, V., & Paganin, D. M. (2016) · Physical Review Letters · doi:10.1103/physrevlett.117.113902 · Cited by 367
Simultaneous real-time visible and infrared video with single-pixel detectors
Edgar, M. P., Gibson, G. M., Bowman, R. W., Sun, B., Radwell, N., Mitchell, K. J., Welsh, S. S., & Padgett, M. J. (2015) · Scientific Reports · doi:10.1038/srep10669 · Cited by 332
Learning from simulation: An end-to-end deep-learning approach for computational ghost imaging
Wang, F., Wang, H., Wang, H., Li, G., & Situ, G. (2019) · Optics Express · doi:10.1364/oe.27.025560 · Cited by 332
Ota, S., Horisaki, R., Kawamura, Y., Ugawa, M., Sato, I., Hashimoto, K., Kamesawa, R., Setoyama, K., Yamaguchi, S., Fujiu, K., et al. (2018) · Science · doi:10.1126/science.aan0096 · Cited by 257
Estimation of many-body quantum Hamiltonians via compressive sensing
Shabani, A., Mohseni, M., Lloyd, S., Kosut, R. L., & Rabitz, H. (2011) · Physical Review A · doi:10.1103/physreva.84.012107 · Cited by 78
Metadata
- Authors
- Katz, O., Bromberg, Y., & Silberberg, Y.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2009-09-28
- Volume
- 95
- Issue
- 13
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2076541487
- Cited by
- 1,018
- References
- 15
- FWCI
- 9.15
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.