The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Frequency modulation detection using high-Q cantilevers for enhanced force microscope sensitivity
Abstract
A new frequency modulation (FM) technique has been demonstrated which enhances the sensitivity of attractive mode force microscopy by an order of magnitude or more. Increased sensitivity is made possible by operating in a moderate vacuum (<10−3 Torr), which increases the Q of the vibrating cantilever. In the FM technique, the cantilever serves as the frequency determining element of an oscillator. Force gradients acting on the cantilever cause instantaneous frequency modulation of the oscillator output, which is demodulated with a FM detector. Unlike conventional ‘‘slope detection,’’ the FM technique offers increased sensitivity through increased Q without restricting system bandwidth. Experimental comparisons of FM detection in vacuum (Q∼50 000) versus slope detection in air (Q∼100) demonstrated an improvement of more than 10 times in sensitivity for a fixed bandwidth. This improvement is evident in images of magnetic transitions on a thin-film CoPtCr magnetic disk. In the future, the increased sensitivity offered by this technique should extend the range of problems accessible by force microscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Atomic force microscope–force mapping and profiling on a sub 100-Å scale
Martin, Y., Williams, C. C., & Wickramasinghe, H. K. (1987) · Journal of Applied Physics · doi:10.1063/1.338807 · Cited by 1,428
Magnetic imaging by ‘‘force microscopy’’ with 1000 Å resolution
Martin, Y., & Wickramasinghe, H. K. (1987) · Applied Physics Letters · doi:10.1063/1.97800 · Cited by 1,151
Improved fiber-optic interferometer for atomic force microscopy
Rugar, D., Mamin, H. J., & Guethner, P. (1989) · Applied Physics Letters · doi:10.1063/1.101987 · Cited by 629
Self-citationMagnetic force microscopy: General principles and application to longitudinal recording media
Rugar, D., Mamin, H. J., Guethner, P., Lambert, S. E., Stern, J. E., McFadyen, I., & Yogi, T. (1990) · Journal of Applied Physics · doi:10.1063/1.346713 · Cited by 624
Self-citationContact electrification using force microscopy
Terris, B. D., Stern, J. E., Rugar, D., & Mamin, H. J. (1989) · Physical Review Letters · doi:10.1103/physrevlett.63.2669 · Cited by 531
Self-citationRobins, W. P. (1984) · Institution of Engineering and Technology eBooks · doi:10.1049/pbte009e · Cited by 370
Atomic Force Microscopy: General Principles and a New Implementation
McClelland, G. M., Erlandsson, R., & Chiang, S. (1987) · Review of Progress in Quantitative Nondestructive Evaluation · doi:10.1007/978-1-4613-1893-4_148 · Cited by 100
Cited by
The surface science of titanium dioxide
Diebold, U. (2003) · Surface Science Reports · doi:10.1016/s0167-5729(02)00100-0 · Cited by 7,944
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 3,709
Advances in atomic force microscopy
Giessibl, F. J. (2003) · Reviews of Modern Physics · doi:10.1103/revmodphys.75.949 · Cited by 2,278
Dynamic atomic force microscopy methods
García, R. (2002) · Surface Science Reports · doi:10.1016/s0167-5729(02)00077-8 · Cited by 2,076
The Chemical Structure of a Molecule Resolved by Atomic Force Microscopy
Gross, L., Mohn, F., Moll, N., Liljeroth, P., & Meyer, G. (2009) · Science · doi:10.1126/science.1176210 · Cited by 1,842
Metadata
- Authors
- Albrecht, T. R., Grütter, P., Horne, D., & Rugar, D.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 1991-01-15
- Volume
- 69
- Issue
- 2
- Pages
- 668-673
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2051001465
- Cited by
- 2,434
- References
- 8
- FWCI
- 8.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.