Versatile apparatus for attosecond metrology and spectroscopy

Open access
Fieß, M., Schultze, M., Goulielmakis, E., Dennhardt, B., Gagnon, J., Hofstetter, M., Kienberger, R., Krausz, F. · 2010 · Review of Scientific Instruments
Cited by 52

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

We present the AS-2 Attosecond Beamline at the Joint Laboratory for Attosecond Physics of the Max-Planck-Institut für Quantenoptik and Ludwig-Maximilians-Universität for time resolved pump/probe experiments with attosecond resolution. High harmonic generation and subsequent filtering of the generated extreme ultraviolet (XUV) continuum by means of metal filters and XUV multilayer mirrors serve for the generation of isolated attosecond laser pulses. After high harmonic generation, the remaining fundamental laser pulse is spatially separated from the attosecond XUV pulse, to what is to our knowledge for the first time, by means of a perforated mirror in a Mach–Zehnder interferometer. Active stabilization of this interferometer guarantees the necessary temporal resolution for tracking attosecond dynamics in real time. As a proof-of-principle, photoelectron streaking experiments are performed and experimental techniques for their realization are summarized. Finally we highlight the potential of the presented beamline system for future experiments in comparison with previously demonstrated attosecond beamlines.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.3475689

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 52

Metadata

Authors
Fieß, M., Schultze, M., Goulielmakis, E., Dennhardt, B., Gagnon, J., Hofstetter, M., Kienberger, R., & Krausz, F.
Venue
Review of Scientific Instruments
Published
2010-09-01
Volume
81
Issue
9
Pages
093103-093103
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2051014653
Cited by
52
References
4
FWCI
2.41
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.