The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Measurement of the thermal conductance of the graphene/SiO2 interface
Abstract
We have examined the interfacial thermal conductance GK of single and multilayer graphene samples prepared on fused SiO2 substrates by mechanical exfoliation of graphite. By using an ultrafast optical pump pulse and monitoring the transient reflectivity on the picosecond time scale, we obtained an average value of GK of GK=5000 W/cm2 K for the graphene/SiO2 interface at room temperature. We observed significant variation in GK between individual samples, but found no systematic dependence on the thickness of the graphene layers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Superior Thermal Conductivity of Single-Layer Graphene
Balandin, A. A., Ghosh, S., Bao, W., Calizo, I., Teweldebrhan, D., Miao, F., & Lau, C. N. (2008) · Nano Letters · doi:10.1021/nl0731872 · Cited by 13,823
Fine Structure Constant Defines Visual Transparency of Graphene
Nair, R. R., Blake, P., Grigorenko, A. N., Novoselov, K. S., Booth, T. J., Stauber, T., Peres, N. M. R., & Geim, A. K. (2008) · Science · doi:10.1126/science.1156965 · Cited by 9,084
Two-Dimensional Phonon Transport in Supported Graphene
Seol, J. H., Jo, I., Moore, A. L., Lindsay, L., Aitken, Z. H., Pettes, M. T., Li, X., Yao, Z., Huang, R., Broido, D., et al. (2010) · Science · doi:10.1126/science.1184014 · Cited by 1,926
Kapitza conductance and heat flow between solids at temperatures from 50 to 300 K
Stoner, R. J., & Maris, H. J. (1993) · Physical Review B · doi:10.1103/physrevb.48.16373 · Cited by 646
Thermometry and Thermal Transport in Micro/Nanoscale Solid-State Devices and Structures
Cahill, D. G., Goodson, K., & Majumdar, A. (2002) · Journal of Heat Transfer · doi:10.1115/1.1454111 · Cited by 611
Cited by
Thermal properties of graphene and nanostructured carbon materials
Balandin, A. A. (2011) · Nature Materials · doi:10.1038/nmat3064 · Cited by 6,244
Progress, Challenges, and Opportunities in Two-Dimensional Materials Beyond Graphene
Butler, S. Z., Hollen, S. M., Cao, L., Cui, Y., Gupta, J. A., Gutiérrez, H. R., Heinz, T. F., Hong, S. S., Huang, J., Ismach, A. F., et al. (2013) · ACS Nano · doi:10.1021/nn400280c · Cited by 4,878
Self-citationEmerging challenges and materials for thermal management of electronics
Moore, A. L., & Shi, L. (2014) · Materials Today · doi:10.1016/j.mattod.2014.04.003 · Cited by 2,106
Thermal Conductivity and Phonon Transport in Suspended Few-Layer Hexagonal Boron Nitride
Jo, I., Pettes, M. T., Kim, J., Watanabe, K., Taniguchi, T., Yao, Z., & Shi, L. (2013) · Nano Letters · doi:10.1021/nl304060g · Cited by 770
Thermal Conductance Imaging of Graphene Contacts
Yang, J., Ziade, E., Maragliano, C., Crowder, R., Wang, X., Stefancich, M., Chiesa, M., Swan, A. K., & Schmidt, A. J. (2014) · Journal of Applied Physics · doi:10.1063/1.4889928 · Cited by 85
Metadata
- Authors
- Mak, K. F., Lui, C. H., & Heinz, T. F.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2010-11-29
- Volume
- 97
- Issue
- 22
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W1996946432
- Cited by
- 192
- References
- 5
- FWCI
- 5.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement of the thermal conductance of the graphene/SiO2 interface. https://app.cochat.ai/papers/10.1063/1.3511537
- The paper
- Mak, K. F., Lui, C. H., & Heinz, T. F. (2010). Measurement of the thermal conductance of the graphene/SiO2 interface. Applied Physics Letters. https://doi.org/10.1063/1.3511537
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.