Abstract
Magnetic particle imaging (MPI) uses safe iron oxide nanoparticle tracers to offer fundamentally new capabilities for medical imaging, in applications as vascular imaging and ultra-sensitive cancer therapeutics. MPI is perhaps the first medical imaging platform to intrinsically exploit nanoscale material properties. MPI tracers contain magnetic nanoparticles whose tunable, size-dependent magnetic properties can be optimized by selecting a particular particle size and narrow size-distribution. In this paper we present experimental MPI measurements acquired using a homemade MPI magnetometer: a zero-dimensional MPI imaging system designed to characterize tracer performance by measuring the derivative of the time-varying tracer magnetization, M’(H(t)), at a driving frequency of 25 kHz. We show that MPI performance is optimized by selecting phase-pure magnetite tracers of a particular size and narrow size distribution; in this work, tracers with 20 nm median diameter, log-normal distribution shape parameter, σv, equal to 0.26, and hydrodynamic diameter equal to 30 nm showed the best performance. Furthermore, these optimized MPI tracers show 4 × greater signal intensity (measured at the third harmonic) and 20% better spatial resolution compared with commercial nanoparticles developed for MRI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanomaterials for In Vivo Imaging
Smith, B. R., & Gambhir, S. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00073 · Cited by 1,075
In vivo delivery, pharmacokinetics, biodistribution and toxicity of iron oxide nanoparticles
Arami, H., Khandhar, A., Liggitt, D., & Krishnan, K. M. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00541h · Cited by 830
Self-citationRecent advances in magnetic nanoparticle-based multi-modal imaging
Shin, T.-H., Choi, Y., Kim, S., & Cheon, J. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00345d · Cited by 602
Magnetic nanoparticles in nanomedicine: a review of recent advances
Wu, K., Su, D., Liu, J., Saha, R., & Wang, J.-P. (2019) · Nanotechnology · doi:10.1088/1361-6528/ab4241 · Cited by 509
Nanotechnology-based approaches in anticancer research
Kamal, M. A., Jabir NR, N., Tabrez, Ashraf, Shakil, & Damanhouri (2012) · International Journal of Nanomedicine · doi:10.2147/ijn.s33838 · Cited by 363
Synthesis of phase-pure and monodisperse iron oxide nanoparticles by thermal decomposition
Hufschmid, R., Arami, H., Ferguson, R. M., Gonzales, M., Teeman, E., Brush, L. N., Browning, N. D., & Krishnan, K. M. (2015) · Nanoscale · doi:10.1039/c5nr01651g · Cited by 341
“MPS plots were normalized to compare the full width at half maximum (FWHM), which is an indicator of the potential spatial resolution in MPI scanners.(8,54) The median magnetic core size and distribution were determined from VSM magnetization curves using the Chantrell method.”
Self-citationTowards clinically translatable in vivo nanodiagnostics
Park, S.-M., Aalipour, A., Vermesh, O., Yu, J. H., & Gambhir, S. S. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.14 · Cited by 327
Recent Developments in Magnetic Diagnostic Systems
Lee, H., Shin, T.-H., Cheon, J., & Weissleder, R. (2015) · Chemical Reviews · doi:10.1021/cr500698d · Cited by 292
Surface design of magnetic nanoparticles for stimuli-responsive cancer imaging and therapy
Kang, T., Li, F., Baik, S., Shao, W., Ling, D., & Hyeon, T. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.05.013 · Cited by 280
Magnetic particle imaging with tailored iron oxide nanoparticle tracers
Ferguson, R. M., Khandhar, A. P., Kemp, S. J., Arami, H., Saritas, E. U., Croft, L. R., Konkle, J., Goodwill, P. W., Halkola, A., Rahmer, J., et al. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2375065 · Cited by 222
Self-citationHigh-performance iron oxide nanoparticles for magnetic particle imaging – guided hyperthermia (hMPI)
Bauer, L. M., Situ, S. F., Griswold, M. A., & Samia, A. C. S. (2016) · Nanoscale · doi:10.1039/c6nr01877g · Cited by 222
A Review of Magnetic Particle Imaging and Perspectives on Neuroimaging
Wu, L. C., Zhang, Y., Steinberg, G., Qu, H., Huang, S., Cheng, M., Bliss, T., Du, F., Rao, J., Song, G., et al. (2019) · American Journal of Neuroradiology · doi:10.3174/ajnr.a5896 · Cited by 205
Self-citationPablico-Lansigan, M. H., Situ, S. F., & Samia, A. C. S. (2013) · Nanoscale · doi:10.1039/c3nr00544e · Cited by 172
Monodisperse magnetite nanoparticle tracers for in vivo magnetic particle imaging
Khandhar, A. P., Ferguson, R. M., Arami, H., & Krishnan, K. M. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.01.087 · Cited by 152
“The larger size is a result of aggregated nanoparticles that are frequently observed in TEM images of Resovist [8].”
BackgroundMethodInfluentialSelf-citationDesign of superparamagnetic nanoparticles for magnetic particle imaging (MPI)
Du, Y., Lai, P., Leung, C., & Pong, P. (2013) · International Journal of Molecular Sciences · doi:10.3390/ijms140918682 · Cited by 81
“They were proven to be optimal and performed with 20% better spatial resolution and four-times higher sensitivity than Resovist [29].”
Background
Metadata
- Authors
- Ferguson, R. M., Khandhar, A. P., & Krishnan, K. M.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2012-03-02
- Volume
- 111
- Issue
- 7
- Pages
- 7B318-7B3185
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2087137200
- Cited by
- 131
- References
- 0
- FWCI
- 9.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.