Theory of Fourier transform ion cyclotron resonance mass spectroscopy. I. Fundamental equations and low-pressure line shape
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The fundamental relationships for linewidth and resolution for all forms of ion cyclotron resonance spectroscopy are derived. Mass resolution and frequency resolution are shown to be numerically identical in all forms of ion cyclotron resonance spectroscopy. Theoretical Fourier transform ion cyclotron resonance (FT–ICR) spectral line shape has been calculated for the low-pressure limit in which there are essentially no ion–molecule collisions during the observation period. Absorption, dispersion, and magnitude (absolute-value) line shapes are illustrated and discussed. FT–ICR linewidth and resolution are calculated as a function of ionic mass and charge, applied magnetic field strength, and data acquisition time, for various linewidth criteria, and the results are tabulated. FT–ICR linewidth and resolution are then expressed in terms of ionic mass, computer data storage size, and minimum specified ionic mass in the FT–ICR mass range, for various linewidth criteria, and the results are tabulated. Next, FT–ICR upper mass limit is calculated as a function either of ionic charge, applied magnetic field strength, and data acquisition time, or computer data storage size and minimum specified ionic mass in the FT–ICR mass range, and the results are tabulated for several linewidth criteria. For the same observation time and linewidth criterion, FT–ICR zero-pressure resolution is 47% better than with conventional ’’drift’’ cell or ’’trapped-ion’’ cell ICR detection. Finally, the theoretical basis for the FT–ICR spectral segment extraction technique is described, for use in enhancing FT–ICR resolution by several orders of magnitude.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An algorithm for the machine calculation of complex Fourier series
Cooley, J. W., & Tukey, J. W. (1965) · Mathematics of Computation · doi:10.1090/s0025-5718-1965-0178586-1 · Cited by 13,154
Cited by
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Fourier transform ion cyclotron resonance mass spectrometry
Marshall, A. G. (1985) · Accounts of Chemical Research · doi:10.1021/ar00118a006 · Cited by 322
Self-citationMilestones in fourier transform ion cyclotron resonance mass spectrometry technique development
Marshall, A. G. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00324-9 · Cited by 295
Self-citationHigh Resolution Mass Spectrometry
Xian, F., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac203191t · Cited by 281
Self-citationFourier transform ion cyclotron resonance detection: principles and experimental configurations
Marshall, A. G., & Hendrickson, C. L. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00588-7 · Cited by 196
Self-citationSignal modeling for ion cyclotron resonance
Comisarow, M. B. (1978) · The Journal of Chemical Physics · doi:10.1063/1.437143 · Cited by 194
Self-citationFourier Transform Mass Spectrometry
Gross, M. L., & Rempel, D. L. (1984) · Science · doi:10.1126/science.6385250 · Cited by 173
Marshall, A. G., & Roe, D. C. (1980) · The Journal of Chemical Physics · doi:10.1063/1.440338 · Cited by 166
Self-citationRelaxation and spectral line shape in Fourier transform ion resonance spectroscopy
Marshall, A. G., Comisarow, M. B., & Parisod, G. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438196 · Cited by 165
Self-citationLarson, E. J., Zhu, Y., Wu, Z., Chen, B., Zhang, Z., Zhou, S., Han, L., Zhang, Q., & Ge, Y. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.0c03152 · Cited by 21
Metadata
- Authors
- Comisarow, M. B., & Marshall, A. G.
- Venue
- The Journal of Chemical Physics
- Publisher
- AIP Publishing
- Published
- 1976-01-01
- Volume
- 64
- Issue
- 1
- Pages
- 110-119
- ISSN
- 0021-9606 (ISSN-L)
- 1089-7690
- OpenAlex
- W1975700528
- Cited by
- 155
- References
- 1
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.