The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Wireless power transfer to a cardiac implant
Abstract
We analyze wireless power transfer between a source and a weakly coupled implant on the heart. Numerical studies show that mid-field wireless powering achieves much higher power transfer efficiency than traditional inductively coupled systems. With proper system design, power sufficient to operate typical cardiac implants can be received by millimeter-sized coils.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, inductive power transfer introduces numerous bioengineering challenges due to Specific Absorption Rate (SAR) limits and minimal size capacity for device implantation.”
From Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system (2017) · cites this paper as [19]
In the citing paper
“Continuous midfield powering has been utilized to power a cardiac implant at a 5 cm range by coupling 500 mW into tissue and achieving nearly 200 µW while remaining below SAR safety thresholds19, 20.”
From Inductively powered wireless pacing via a miniature pacemaker and remote stimulation control system (2017) · cites this paper as [19]
In the citing paper
“Provided that the fields can be refocused, computational studies show that the performance is insensitive to the fine structure and composition of the intermediate tissue (30).”
From Wireless power transfer to deep-tissue microimplants (2014) · cites this paper as [30]
Citations
Cites
Wireless Power Transfer via Strongly Coupled Magnetic Resonances
Kurs, A., Karalis, A., Moffatt, R., Joannopoulos, J. D., Fisher, P., & Soljačić, M. (2007) · Science · doi:10.1126/science.1143254 · Cited by 5,576
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175
The Design of CMOS Radio-Frequency Integrated Circuits
Lee, T. H. (2003) · Cambridge University Press eBooks · doi:10.1017/cbo9780511817281 · Cited by 3,497
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Optimal Frequency for Wireless Power Transmission Into Dispersive Tissue
Poon, A. S. Y., O'Driscoll, S., & Meng, T. H. (2010) · IEEE Transactions on Antennas and Propagation · doi:10.1109/tap.2010.2044310 · Cited by 469
Self-citationA very low-power CMOS mixed-signal IC for implantable pacemaker applications
Wong, L. S. Y., Hossain, S., Ta, A., Edvinsson, J., Rivas, D. H., & Naas, H. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.837027 · Cited by 395
Design of radio-frequency powered coils for implant instruments
Ko, W. H., Liang, S. P., & Fung, C. D. F. (1977) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457921 · Cited by 374
RF powering of millimeter- and submillimeter-sized neural prosthetic implants
Heetderks, W. J. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1388 · Cited by 197
A fully integrated low-power BPSK demodulator for implantable medical devices
Hu, Y., & Sawan, M. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.858163 · Cited by 184
Suaning, G. J., & Lovell, N. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.909646 · Cited by 164
Research works printed but not linked: 1
- S. Kim and A. S. Y. Poon, in IEEE Antennas and Propagation Society International Symposium (APSURSI), Spokane, WA, 2010.
Cited by
Wireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541
Self-citationModeling of Mutual Coupling Between Planar Inductors in Wireless Power Applications
Raju, S., Wu, R., Chan, M., & Yue, C. P. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2253334 · Cited by 343
Self-rechargeable cardiac pacemaker system with triboelectric nanogenerators
Ryu, H., Park, H.-M., Kim, M.-K., Kim, B., Myoung, H. S., Kim, T. Y., Yoon, H.-J., Kwak, S. S., Kim, J., Hwang, T. H., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-24417-w · Cited by 329
Self-citationOpportunities and Challenges for Near-Field Wireless Power Transfer: A Review
Jawad, A. M., Nordin, R., Gharghan, S. K., Jawad, H. M., & Ismail, M. (2017) · Energies · doi:10.3390/en10071022 · Cited by 268
Midfield Wireless Powering for Implantable Systems
Ho, J. S., Kim, S., & Poon, A. S. Y. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2251851 · Cited by 227
Self-citation
Metadata
- Authors
- Kim, S., Ho, J. S., Chen, L. Y., & Poon, A. S. Y.
- Affiliations
- Stanford University (US)
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 2012-08-13
- Volume
- 101
- Issue
- 7
- Pages
- 073701
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2063926442
- Semantic Scholar
- ab3b2d3793146cdf15834c4624c78eeaa4cb3218
- Cited by
- 148
- References
- 16
- Citations by year
- 2025: 5 · 2024: 4 · 2023: 9 · 2022: 7 · 2021: 10 · 2020: 10 · 2019: 10 · 2018: 12 · 2017: 25 · 2016: 12 · 2015: 17 · 2014: 13 · 2013: 13 · 2012: 1
- FWCI
- 9.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Applied Physics Letters (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
- Keywords
- wireless power transfer, cardiac implantable electronic devices, inductive coupling, power transfer efficiency, biomedical implants, weakly coupled systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Wireless power transfer to a cardiac implant. https://app.cochat.ai/papers/10.1063/1.4745600
- The paper
- Kim, S., Ho, J. S., Chen, L. Y., & Poon, A. S. Y. (2012). Wireless power transfer to a cardiac implant. Applied Physics Letters. https://doi.org/10.1063/1.4745600
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.