Room-temperature operation of a radiofrequency diamond magnetometer near the shot-noise limit
Open accessThe DOI matches its Crossref record.
Abstract
We operate a nitrogen-vacancy (NV−) diamond magnetometer at ambient temperatures and study the dependence of its bandwidth on experimental parameters including optical and microwave excitation powers. A model based on the Bloch equations is used to analyze the NV center's response time, τ, during continuous optical and microwave irradiation, and τ−1 is shown to be a weighted average of T1−1 and T2−1, where T1 and T2 are the longitudinal and transverse relaxation times of the electron spin during optical irradiation. We measured a maximum detection bandwidth of ∼1.6 MHz with optical excitation intensity of ∼2.3 MW/cm2, limited by the available optical power. The sensitivity of the NV ensemble for continuous-wave magnetometry in the presence of photon shot noise is analyzed. Two detection schemes are compared, one involving modulation of the fluorescence by an oscillating magnetic field while the microwave frequency is held constant, and the other involving double modulation of the fluorescence when the microwave frequency is modulated during the detection. For the first of these methods, we measure a sensitivity of 4.6 ± 0.3 nT/√Hz, unprecedented in a detector with this active volume of ∼10 μm3 and close to the photon-shot-noise limit of our experiment. The measured bandwidth and sensitivity of our device should allow detection of micro-scale NMR signals with microfluidic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sensitivity optimization for NV-diamond magnetometry
Barry, J. F., Schloss, J. M., Bauch, E., Turner, M. J., Hart, C. A., Pham, L. M., & Walsworth, R. L. (2020) · Reviews of Modern Physics · doi:10.1103/revmodphys.92.015004 · Cited by 1,247
Optical magnetic detection of single-neuron action potentials using quantum defects in diamond
Barry, J. F., Turner, M. J., Schloss, J. M., Glenn, D. R., Song, Y., Lukin, M. D., Park, H., & Walsworth, R. L. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1601513113 · Cited by 637
Principles and techniques of the quantum diamond microscope
Levine, E. V., Turner, M. J., Kehayias, P., Hart, C. A., Langellier, N., Trubko, R., Glenn, D. R., Fu, R. R., & Walsworth, R. L. (2019) · Nanophotonics · doi:10.1515/nanoph-2019-0209 · Cited by 275
Simultaneous Broadband Vector Magnetometry Using Solid-State Spins
Schloss, J. M., Barry, J. F., Turner, M. J., & Walsworth, R. L. (2018) · Physical Review Applied · doi:10.1103/physrevapplied.10.034044 · Cited by 270
Millimetre-scale magnetocardiography of living rats with thoracotomy
Arai, K., Kuwahata, A., Nishitani, D., Fujisaki, I., Matsuki, R., Nishio, Y., Xin, Z., Cao, X., Hatano, Y., Onoda, S., et al. (2022) · Communications Physics · doi:10.1038/s42005-022-00978-0 · Cited by 85
Petrini, G., Moreva, E., Bernardi, E., Traina, P., Tomagra, G., Carabelli, V., Degiovanni, I. P., & Genovese, M. (2020) · Advanced Quantum Technologies · doi:10.1002/qute.202000066 · Cited by 63
Magnetometry with nitrogen-vacancy centers in diamond
Jensen, K., Kehayias, P., & Budker, D. (2017) · Smart Sensors, Measurement and Instrumentation · doi:10.1007/978-3-319-34070-8_18 · Cited by 38
Self-citationOptimizing NV magnetometry for magnetoneurography and magnetomyography applications
Zhang, C., Zhang, J., Widmann, M., Benke, M., Kübler, M., Dasari, D., Klotz, T., Gizzi, L., Röhrle, O., Brenner, P., et al. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.1034391 · Cited by 34
Metadata
- Authors
- Shin, C. S., Avalos, C. E., Butler, M. C., Trease, D. R., Seltzer, S. J., Peter Mustonen, J., Kennedy, D. J., Acosta, V. M., Budker, D., Pines, A., & Bajaj, V. S.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2012-12-15
- Volume
- 112
- Issue
- 12
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W1999239371
- Cited by
- 59
- References
- 0
- FWCI
- 1.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.