Invited Review Article: Error and uncertainty in Raman thermal conductivity measurements
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Error and uncertainty in Raman thermal conductivity measurements are investigated via finite element based numerical simulation of two geometries often employed—Joule-heating of a wire and laser-heating of a suspended wafer. Using this methodology, the accuracy and precision of the Raman-derived thermal conductivity are shown to depend on (1) assumptions within the analytical model used in the deduction of thermal conductivity, (2) uncertainty in the quantification of heat flux and temperature, and (3) the evolution of thermomechanical stress during testing. Apart from the influence of stress, errors of 5% coupled with uncertainties of ±15% are achievable for most materials under conditions typical of Raman thermometry experiments. Error can increase to >20%, however, for materials having highly temperature dependent thermal conductivities or, in some materials, when thermomechanical stress develops concurrent with the heating. A dimensionless parameter—termed the Raman stress factor—is derived to identify when stress effects will induce large levels of error. Taken together, the results compare the utility of Raman based conductivity measurements relative to more established techniques while at the same time identifying situations where its use is most efficacious.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This eliminates the need for the metal film transducer, meaning the sample material of interest is directly measured, mitigating some of the transducer-related issues (65).”
From Limitations and Advances in Optical Thermal Transport Measurements: Extremes in Properties, Length Scales, and Temperature (2025) · cites this paper as [65]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal conductivity measurement from 30 to 750 K: the 3ω method
Cahill, D. G. (1990) · Review of Scientific Instruments · doi:10.1063/1.1141498 · Cited by 1,928
Two-Dimensional Phonon Transport in Supported Graphene
Seol, J. H., Jo, I., Moore, A. L., Lindsay, L., Aitken, Z. H., Pettes, M. T., Li, X., Yao, Z., Huang, R., Broido, D., et al. (2010) · Science · doi:10.1126/science.1184014 · Cited by 1,926
Analysis of heat flow in layered structures for time-domain thermoreflectance
Cahill, D. G. (2004) · Review of Scientific Instruments · doi:10.1063/1.1819431 · Cited by 1,543
Thermal conductance of interfaces between highly dissimilar materials
Lyeo, H.-K., & Cahill, D. G. (2006) · Physical Review B · doi:10.1103/physrevb.73.144301 · Cited by 576
Beechem, T., Graham, S., Kearney, S. P., Phinney, L. M., & Serrano, J. R. (2007) · Review of Scientific Instruments · doi:10.1063/1.2738946 · Cited by 190
Self-citationEnglish, T. S., Phinney, L. M., Hopkins, P. E., & Serrano, J. R. (2013) · Journal of Heat Transfer · doi:10.1115/1.4024357 · Cited by 14
Research works printed but not linked: 37
- 2013, Nature, 499, 419, 10.1038/nature12385 · DOI · Paper page
- 2011, Spectroscopy, 26, 36
- 2002, Appl. Phys. Lett., 82, 124, 10.1063/1.1534935 · DOI · Paper page
- 2008, J. Appl. Phys., 103, 124501, 10.1063/1.2940131 · DOI
- 2013, Rev. Sci. Instrum., 84, 064903, 10.1063/1.4810850 · DOI
- 2008, Nano Lett., 8, 902, 10.1021/nl0731872 · DOI · Paper page
- 2010, Nano Lett., 10, 1645, 10.1021/nl9041966 · DOI · Paper page
- 2010, ACS Nano, 4, 1889, 10.1021/nn9016229 · DOI · Paper page
- 2011, Phys. Rev. B, 83, 081419, 10.1103/PhysRevB.83.081419 · DOI · Paper page
- 2010, ACS Nano, 5, 321, 10.1021/nn102915x · DOI · Paper page
- 2009, Nano Lett., 9, 590, 10.1021/nl802737q · DOI
- 2009, Nanotechnology, 20, 145702, 10.1088/0957-4484/20/14/145702 · DOI · Paper page
- 2009, Appl. Phys. A: Mater. Sci. Process., 97, 19, 10.1007/s00339-009-5352-6 · DOI
- 2010, Appl. Phys. Lett., 97, 263107, 10.1063/1.3532848 · DOI
- 1999, J. Appl. Phys., 86, 4700, 10.1063/1.371424 · DOI · Paper page
- 2000, Sens. Actuators, A, 85, 335, 10.1016/S0924-4247(00)00327-7 · doi:10.1016/s0924-4247(00)00327-7
- 2010, Nano Lett., 10, 3909, 10.1021/nl101613u · DOI · Paper page
- 2007, Fundamentals of Heat and Mass Transfer
- 1999, J. Appl. Phys., 85, 8502, 10.1063/1.370635 · doi:10.1063/1.370635
- 2008, Science, 321, 385, 10.1126/science.1157996 · DOI · Paper page
- 2007, J. Appl. Phys., 102, 023505, 10.1063/1.2749484 · doi:10.1063/1.2749484
- 1996, Structural defects and their relationship to nucleation of gan thin films, MRS Proc., 423, 475, 10.1557/PROC-423-475 · doi:10.1557/proc-423-475
- 2009, Nat. Nanotechnol., 4, 562, 10.1038/nnano.2009.191 · DOI · Paper page
- 2007, IEEE Trans. Electron Devices, 54, 1838, 10.1109/TED.2007.901349 · DOI
- 1997, J. Appl. Phys., 82, 4493, 10.1063/1.366182 · doi:10.1063/1.366182
- 1996, Semicond. Sci. Technol., 11, 139, 10.1088/0268-1242/11/2/001 · DOI · Paper page
- 2009, J. Appl. Phys., 106, 114509, 10.1063/1.3267157 · DOI
- 2009, Phys. Rev. B, 79, 205433, 10.1103/PhysRevB.79.205433 · DOI · Paper page
- 2013, J. Phys. Chem. C, 117, 9042, 10.1021/jp402509w · DOI · Paper page
- 2014, ACS Nano, 8, 986, 10.1021/nn405826k · DOI · Paper page
- 2014, Rev. Sci. Instrum., 85, 034901, 10.1063/1.4867166 · DOI
- 2014, Nanoscale Microscale Thermophys. Eng., 18, 183, 10.1080/15567265.2014.892553 · DOI
- 2009, Int. J. Heat Mass Transfer, 52, 2255, 10.1016/j.ijheatmasstransfer.2008.12.003 · DOI
- ISRN Mech. Eng., 2013, 10.1155/2013/682586 · DOI · Paper page
- 2009, J. Appl. Phys., 105, 054303, 10.1063/1.3078808 · DOI · Paper page
- 2009, Nano Lett., 9, 257, 10.1021/nl802840w · DOI
- 2015, Phys. Rev. B, 91, 075426, 10.1103/PhysRevB.91.075426 · doi:10.1103/physrevb.91.075426
Cited by
Raman spectroscopy of carbon materials and their composites: Graphene, nanotubes and fibres
Li, Z., Deng, L., Kinloch, I. A., & Young, R. J. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2023.101089 · Cited by 1,117
Anisotropic in-plane thermal conductivity observed in few-layer black phosphorus
Luo, Z., Maassen, J., Deng, Y., Du, Y., Garrelts, R. P., Lundstrom, M. S., Ye, P. D., & Xu, X. (2015) · Nature Communications · doi:10.1038/ncomms9572 · Cited by 662
Pfeifer, T. W., Schonfeld, H. B., Scott, E. A., Aller, H. T., Gaskins, J. T., Olson, D. H., Braun, J. L., Graham, S., & Hopkins, P. E. (2025) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-080423-010435 · Cited by 16
“This eliminates the need for the metal film transducer, meaning the sample material of interest is directly measured, mitigating some of the transducer-related issues (65).”
Self-citation
Metadata
- Authors
- Beechem, T., Yates, L., & Graham, S.
- Affiliations
- Sandia National Laboratories 1 , Albuquerque, New Mexico 87123, USA
- G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology 2 , Atlanta, Georgia 30332, USA
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2015-04-01
- Volume
- 86
- Issue
- 4
- ISSN
- 0034-6748
- 1089-7623
- Cited by
- 75
- References
- 6
- Language
- en
- Funders
- U.S. Department of Energy (DE-AC04-94AL85000)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.