Highly sensitive superconducting circuits at ∼700 kHz with tunable quality factors for image-current detection of single trapped antiprotons
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
We developed highly sensitive image-current detection systems based on superconducting toroidal coils and ultra-low noise amplifiers for non-destructive measurements of the axial frequencies (550–800 kHz) of single antiprotons stored in a cryogenic multi-Penning-trap system. The unloaded superconducting tuned circuits show quality factors of up to 500 000, which corresponds to a factor of 10 improvement compared to our previously used solenoidal designs. Connected to ultra-low noise amplifiers and the trap system, signal-to-noise-ratios of 30 dB at quality factors of >20 000 are achieved. In addition, we have developed a superconducting switch which allows continuous tuning of the detector’s quality factor and to sensitively tune the particle-detector interaction. This allowed us to improve frequency resolution at constant averaging time, which is crucial for single antiproton spin-transition spectroscopy experiments, as well as improved measurements of the proton-to-antiproton charge-to-mass ratio.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-accuracy mass spectrometry with stored ions
Blaum, K. (2006) · Physics Reports · doi:10.1016/j.physrep.2005.10.011 · Cited by 685
Self-citationPrinciples of the stored ion calorimeter
Wineland, D. J., & Dehmelt, H. G. (1975) · Journal of Applied Physics · doi:10.1063/1.321602 · Cited by 328
High-precision measurement of the atomic mass of the electron
Sturm, S., Köhler, F., Zatorski, J., Wagner, A., Harman, Z., Werth, G., Quint, W., Keitel, C. H., & Blaum, K. (2014) · Nature · doi:10.1038/nature13026 · Cited by 326
Self-citationHigh-precision comparison of the antiproton-to-proton charge-to-mass ratio
Ulmer, S., Smorra, C., Mooser, A., Franke, K., Nagahama, H., Schneider, G., Higuchi, T., Van Gorp, S., Blaum, K., Matsuda, Y., et al. (2015) · Nature · doi:10.1038/nature14861 · Cited by 147
Self-citationDirect high-precision measurement of the magnetic moment of the proton
Mooser, A., Ulmer, S., Blaum, K., Franke, K., Kracke, H., Leiteritz, C., Quint, W., Rodegheri, C. C., Smorra, C., & Walz, J. (2014) · Nature · doi:10.1038/nature13388 · Cited by 96
Self-citationDirect Measurement of the Proton Magnetic Moment
DiSciacca, J., & Gabrielse, G. (2012) · Physical Review Letters · doi:10.1103/physrevlett.108.153001 · Cited by 56
Ulmer, S., Blaum, K., Kracke, H., Mooser, A., Quint, W., Rodegheri, C. C., & Walz, J. (2013) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2012.12.071 · Cited by 48
Self-citation
Cited by
A parts-per-billion measurement of the antiproton magnetic moment
Smorra, C., Sellner, S., Borchert, M. J., Harrington, J. A., Higuchi, T., Nagahama, H., Tanaka, T., Mooser, A., Schneider, G., Bohman, M., et al. (2017) · Nature · doi:10.1038/nature24048 · Cited by 149
Self-citationWang, J.-R., Wu, J.-F., Zhang, T.-H., Liu, J.-L., Peng, J.-T., Wang, J.-W., Shen, Y., Wei, B.-R., Zou, Y.-M., & Tu, B.-S. (2025) · Nuclear Science and Techniques · doi:10.1007/s41365-025-01797-y · Cited by 4
Off-resonance electronic detection and cooling of ions in a Penning trap
Ringleb, S., Kiffer, M., Vogel, M., & Stöhlker, T. (2024) · The European Physical Journal Plus · doi:10.1140/epjp/s13360-024-05183-2 · Cited by 3
Metadata
- Authors
- Nagahama, H., Schneider, G., Mooser, A., Smorra, C., Sellner, S., Harrington, J., Higuchi, T., Borchert, M., Tanaka, T., Besirli, M., Blaum, K., Matsuda, Y., Ospelkaus, C., Quint, W., Walz, J., Yamazaki, Y., & Ulmer, S.
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2016-11-01
- Volume
- 87
- Issue
- 11
- Pages
- 113305-113305
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- OpenAlex
- W2554925799
- Cited by
- 50
- References
- 7
- FWCI
- 6.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Highly sensitive superconducting circuits at ∼700 kHz with tunable quality factors for image-current detection of single trapped antiprotons. https://app.cochat.ai/papers/10.1063/1.4967493
- The paper
- Nagahama, H., Schneider, G., Mooser, A., Smorra, C., Sellner, S., Harrington, J., Higuchi, T., Borchert, M., Tanaka, T., Besirli, M., Blaum, K., Matsuda, Y., Ospelkaus, C., Quint, W., Walz, J., Yamazaki, Y., & Ulmer, S. (2016). Highly sensitive superconducting circuits at ∼700 kHz with tunable quality factors for image-current detection of single trapped antiprotons. Review of Scientific Instruments. https://doi.org/10.1063/1.4967493
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.