The DOI matches its Crossref record.
Influence of Dy3+ and Tb3+ doping on 13C dynamic nuclear polarization
Abstract
Dynamic nuclear polarization (DNP) is a technique that uses a microwave-driven transfer of high spin alignment from electrons to nuclear spins. This is most effective at low temperature and high magnetic field, and with the invention of the dissolution method, the amplified nuclear magnetic resonance (NMR) signals in the frozen state in DNP can be harnessed in the liquid-state at physiologically acceptable temperature for in vitro and in vivo metabolic studies. A current optimization practice in dissolution DNP is to dope the sample with trace amounts of lanthanides such as Gd3+ or Ho3+, which further improves the polarization. While Gd3+ and Ho3+ have been optimized for use in dissolution DNP, other lanthanides have not been exhaustively studied for use in C13 DNP applications. In this work, two additional lanthanides with relatively high magnetic moments, Dy3+ and Tb3+, were extensively optimized and tested as doping additives for C13 DNP at 3.35 T and 1.2 K. We have found that both of these lanthanides are also beneficial additives, to a varying degree, for C13 DNP. The optimal concentrations of Dy3+ (1.5 mM) and Tb3+ (0.25 mM) for C13 DNP were found to be less than that of Gd3+ (2 mM). W-band electron paramagnetic resonance shows that these enhancements due to Dy3+ and Tb3+ doping are accompanied by shortening of electron T1 of trityl OX063 free radical. Furthermore, when dissolution was employed, Tb3+-doped samples were found to have similar liquid-state C13 NMR signal enhancements compared to samples doped with Gd3+, and both Tb3+ and Dy3+ had a negligible liquid-state nuclear T1 shortening effect which contrasts with the significant reduction in T1 when using Gd3+. Our results show that Dy3+ doping and Tb3+ doping have a beneficial impact on C13 DNP both in the solid and liquid states, and that Tb3+ in particular could be used as a potential alternative to Gd3+ in C13 dissolution DNP experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Solid-state 13C DNP signals were enhanced by 100–250% with the use of trace amounts of paramagnetic additives, with lanthanide complexes with Gd3+, Ho3+, Dy3+ and Tb3+ being the most studied[175,178,180–183].”
From Use of paramagnetic systems to speed-up NMR data acquisition and for structural and dynamic studies (2019) · cites this paper as [180]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 73
- 1961, The Principles of Nuclear Magnetism
- Jue, 2010, Biomedical Applications of Biophysics, 59, 10.1007/978-1-60327-233-9 · DOI
- 1978, Rep. Prog. Phys., 41, 395, 10.1088/0034-4885/41/3/002 · DOI · Paper page
- 1953, Phys. Rev., 89, 689, 10.1103/PhysRev.89.689 · DOI · Paper page
- 1955, Phys. Rev., 98, 1729, 10.1103/PhysRev.98.1729 · doi:10.1103/physrev.98.1729
- 1957, Phys. Rev., 106, 164, 10.1103/PhysRev.106.164 · doi:10.1103/physrev.106.164
- 1963, Dynamic Nuclear Orientation
- 1997, Annu. Rev. Nucl. Part. Sci., 47, 67, 10.1146/annurev.nucl.47.1.67 · doi:10.1146/annurev.nucl.47.1.67
- 2003, Proc. Natl. Acad. Sci. U. S. A., 100, 10158, 10.1073/pnas.1733835100 · DOI · Paper page
- 2016, J. Magn. Reson., 264, 3, 10.1016/j.jmr.2016.01.015 · doi:10.1016/j.jmr.2016.01.015
- 2008, Appl. Magn. Reson., 34, 213, 10.1007/s00723-008-0137-1 · DOI
- 2009, Prog. Nucl. Magn. Reson. Spectrosc., 55, 285, 10.1016/j.pnmrs.2009.06.001 · DOI
- 2011, Magn. Reson. Med., 66, 505, 10.1002/mrm.22999 · DOI · Paper page
- 2006, Acad. Radiol., 13, 932, 10.1016/j.acra.2006.06.001 · DOI · Paper page
- 2006, Proc. Natl. Acad. Sci. U. S. A., 103, 11270, 10.1073/pnas.0601319103 · DOI · Paper page
- 2008, Appl. Magn. Reson., 34, 509, 10.1007/s00723-008-0134-4 · doi:10.1007/s00723-008-0134-4
- Heise, 2011, Modern NMR Methodology, 23
- 2011, Chem. - Eur. J., 17, 10825, 10.1002/chem.201102037 · DOI
- 2012, RSC Adv., 2, 12812, 10.1039/c2ra21853d · DOI
- 2013, J. Magn. Reson., 227, 14, 10.1016/j.jmr.2012.11.006 · DOI
- 2015, J. Phys. Chem. C, 119, 22632, 10.1021/acs.jpcc.5b07315 · doi:10.1021/acs.jpcc.5b07315
- 2014, J. Phys. Chem. Lett., 5, 597, 10.1021/jz402659t · DOI
- 2013, Nat. Nanotechnol., 8, 363, 10.1038/nnano.2013.65 · DOI · Paper page
- 2006, Phys. Rev. B, 74, 134418, 10.1103/PhysRevB.74.134418 · doi:10.1103/physrevb.74.134418
- 2012, Chem. Phys. Lett., 549, 99, 10.1016/j.cplett.2012.08.017 · doi:10.1016/j.cplett.2012.08.017
- 2008, J. Chem. Phys., 128, 241102, 10.1063/1.2951994 · DOI
- 2013, J. Phys. Chem. Lett., 4, 111, 10.1021/jz301781t · doi:10.1021/jz301781t
- 2012, Chem. Phys. Lett., 554, 72, 10.1016/j.cplett.2012.10.018 · doi:10.1016/j.cplett.2012.10.018
- 2012, J. Magn. Reson., 214, 166, 10.1016/j.jmr.2011.11.002 · doi:10.1016/j.jmr.2011.11.002
- 2014, J. Phys. Chem. B, 118, 1411, 10.1021/jp4118776 · doi:10.1021/jp4118776
- 2016, Magn. Reson. Chem., 54, 962, 10.1002/mrc.4480 · DOI
- 2013, Phys. Chem. Chem. Phys., 15, 7032, 10.1039/c3cp50750e · DOI
- 2008, J. Phys. D: Appl. Phys., 41, 155506, 10.1088/0022-3727/41/15/155506 · doi:10.1088/0022-3727/41/15/155506
- 2013, Phys. Chem. Chem. Phys., 15, 9800, 10.1039/c3cp50186h · DOI
- 2012, J. Magn. Reson., 223, 85, 10.1016/j.jmr.2012.07.010 · doi:10.1016/j.jmr.2012.07.010
- 2016, RSC Adv., 6, 38855, 10.1039/C6RA02864K · DOI
- 2012, Magn. Reson. Med., 68, 1949, 10.1002/mrm.24207 · DOI · Paper page
- 2016, Phys. Chem. Chem. Phys., 18, 21351, 10.1039/C6CP03954E · DOI
- 2013, Saf. Health Work, 4, 12, 10.5491/SHAW.2013.4.1.12 · DOI · Paper page
- 1992, Inorg. Chem., 31, 1095, 10.1021/ic00032a034 · doi:10.1021/ic00032a034
- 2008, Bioconjugate Chem., 19, 391, 10.1021/bc700328s · DOI · Paper page
- 2006, Invest. Radiol., 41, 272, 10.1097/01.rli.0000186569.32408.95 · DOI · Paper page
- 1988, Invest. Radiol., 23, S232, 10.1097/00004424-198809001-00048 · doi:10.1097/00004424-198809001-00048
- 1998, Chem. Soc. Rev., 27, 19, 10.1039/A827019Z · DOI
- 2007, Acc. Chem. Res., 40, 206, 10.1021/ar050087z · DOI · Paper page
- 1992, Inorg. Chem., 31, 4291, 10.1021/ic00047a016 · DOI
- 2006, Contrast Media Mol. Imaging, 1, 184, 10.1002/cmmi.110 · DOI · Paper page
- 2013, Phys. Rev. B, 87, 161306, 10.1103/physrevb.87.161306 · doi:10.1103/physrevb.87.161306
- 2011, J. Am. Chem. Soc., 133, 8673, 10.1021/ja201880y · DOI
- 2012, Appl. Magn. Reson., 43, 69, 10.1007/s00723-012-0335-8 · doi:10.1007/s00723-012-0335-8
- 2004, Nucl. Instrum. Methods Phys. Res., Sect. A, 526, 173, 10.1016/j.nima.2004.03.171 · DOI
- 2008, Appl. Magn. Reson., 34, 495, 10.1007/s00723-008-0117-5 · doi:10.1007/s00723-008-0117-5
- 2013, J. Magn. Reson., 230, 212, 10.1016/j.jmr.2013.02.010 · DOI
- 2015, Phys. Chem. Chem. Phys., 17, 26969, 10.1039/C5CP04138D · doi:10.1039/c5cp04138d
- 2012, Phys. Chem. Chem. Phys., 14, 5729, 10.1039/c2cp23915a · DOI
- 2008, Appl. Magn. Reson., 34, 227, 10.1007/s00723-008-0121-9 · doi:10.1007/s00723-008-0121-9
- 2012, J. Magn. Reson., 214, 29, 10.1016/j.jmr.2011.09.047 · DOI
- 2004, Nucl. Instrum. Methods Phys. Res., Sect. A, 526, 28, 10.1016/j.nima.2004.03.147 · doi:10.1016/j.nima.2004.03.147
- 2012, J. Phys. Chem. A, 116, 5129, 10.1021/jp302399f · DOI
- 2001, J. Chem. Phys., 114, 4922, 10.1063/1.1346640 · DOI
- 2014, Phys. Chem. Chem. Phys., 16, 18694, 10.1039/C4CP02013H · doi:10.1039/c4cp02013h
- 2012, Electron Paramagnetic Resonance of Transition Ions
- 1968, Phys. Rev. Lett., 20, 419, 10.1103/PhysRevLett.20.419 · doi:10.1103/physrevlett.20.419
- 1996, Prog. Nucl. Magn. Reson. Spectrosc., 28, 283, 10.1016/0079-6565(95)01026-2 · DOI · Paper page
- 2010, Bioorg. Med. Chem., 18, 5925, 10.1016/j.bmc.2010.06.086 · doi:10.1016/j.bmc.2010.06.086
- Dalton Trans., 2005, 1129, 10.1039/b416150e · doi:10.1039/b416150e
- 2013, Phys. Chem. Chem. Phys., 16, 753, 10.1039/c3cp52534a · DOI
- 2001, J. Phys. Chem. A, 105, 9323, 10.1021/jp0111158 · doi:10.1021/jp0111158
- J. Chem. Soc., Dalton Trans., 1980, 2151, 10.1039/dt9800002151 · doi:10.1039/dt9800002151
- 2005, Magnetism
- 2005, An Introduction to the Optical Spectroscopy of Inorganic Solids
- 1997, J. Magn. Reson., 126, 58, 10.1006/jmre.1997.1159 · doi:10.1006/jmre.1997.1159
- 1984, Am. J. Roentgenol., 142, 619, 10.2214/ajr.142.3.619 · DOI · Paper page
Cited by
Use of paramagnetic systems to speed-up NMR data acquisition and for structural and dynamic studies
Kocman, V., Di Mauro, G. M., Veglia, G., & Ramamoorthy, A. (2019) · Solid State Nuclear Magnetic Resonance · doi:10.1016/j.ssnmr.2019.07.002 · Cited by 45
Metadata
- Authors
- Niedbalski, P., Parish, C., Kiswandhi, A., Fidelino, L., Khemtong, C., Hayati, Z., Song, L., Martins, A., Sherry, A. D., & Lumata, L.
- Affiliations
- University of Texas at Dallas, 800 West Campbell Road 1 Department of Physics, , Richardson, Texas 75080, USA
- University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard 2 Advanced Imaging Research Center, , Dallas, Texas 75390, USA
- Florida State University 3 National High Magnetic Field Laboratory, , Tallahassee, Florida 32310, USA
- ORCID
- Parish, Christopher
- Venue
- The Journal of Chemical Physics
- Publisher
- AIP Publishing
- Published
- 2017-01-03
- Volume
- 146
- Issue
- 1
- ISSN
- 0021-9606
- 1089-7690
- Cited by
- 16
- References
- 0
- Language
- en
- Funders
- National Science Foundation (DMR 1157490)
- National Institutes of Health (8P41-FB015908)
- U.S. Department of Defense (W81XWH-14-1-0048)
- Welch Foundation (AT-1877, AT-584)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of Dy3+ and Tb3+ doping on 13C dynamic nuclear polarization. https://app.cochat.ai/papers/10.1063/1.4973317
- The paper
- Niedbalski, P., Parish, C., Kiswandhi, A., Fidelino, L., Khemtong, C., Hayati, Z., Song, L., Martins, A., Sherry, A. D., & Lumata, L. (2017). Influence of Dy3+ and Tb3+ doping on 13C dynamic nuclear polarization. The Journal of Chemical Physics. https://doi.org/10.1063/1.4973317
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.