Characterizing atomic magnetic gradiometers for fetal magnetocardiography
Open accessThe DOI matches its Crossref record; 31 of the 32 references it cites were found in a registry or an index.
Abstract
Atomic magnetometers (AMs) offer many advantages over superconducting quantum interference devices due to, among other things, having comparable sensitivity while not requiring cryogenics. One of the major limitations of AMs is the challenge of configuring them as gradiometers. We report the development of a spin-exchange relaxation free vector atomic magnetic gradiometer with a sensitivity of 3 fT cm−1 Hz−1/2 and common mode rejection ratio >150 in the band from DC to 100 Hz. We introduce a background suppression figure of merit for characterizing the performance of gradiometers. It allows for optimally setting the measurement baseline and for quickly assessing the advantage, if any, of performing a measurement in a gradiometric mode. As an application, we consider the problem of fetal magnetocardiography (fMCG) detection in the presence of a large background maternal MCG signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010) · Applied Physics Letters · doi:10.1063/1.3491215 · Cited by 891
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Subfemtotesla Scalar Atomic Magnetometry Using Multipass Cells
Sheng, D., Li, S., Dural, N., & Romalis, M. V. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.160802 · Cited by 364
Magnetoencephalography with a chip-scale atomic magnetometer
Sander, T. H., Preusser, J., Mhaskar, R., Kitching, J., Trahms, L., & Knappe, S. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000981 · Cited by 293
Magnetoencephalography with a two-color pump-probe, fiber-coupled atomic magnetometer
Johnson, C., Schwindt, P. D. D., & Weisend, M. (2010) · Applied Physics Letters · doi:10.1063/1.3522648 · Cited by 210
A room temperature 19-channel magnetic field mapping device for cardiac signals
Bison, G., Castagna, N., Hofer, A., Knowles, P., Schenker, J.-L., Kasprzak, M., Saudan, H., & Weis, A. (2009) · Applied Physics Letters · doi:10.1063/1.3255041 · Cited by 186
A microfabricated optically-pumped magnetic gradiometer
Sheng, D., Perry, A. R., Krzyzewski, S. P., Geller, S., Kitching, J., & Knappe, S. (2017) · Applied Physics Letters · doi:10.1063/1.4974349 · Cited by 179
Research works printed but not linked: 11
- 2006, Oceans 2006, 1
- 9 J. Clarke and A. I. Braginski, The SQUID Handbook (John Wiley and Sons, Inc, 2009).
- 11 H. B. Dang, A. C. Maloof, and M. V. Romalis, Applied Physics Letters 97 , 151110 (2010).
- 16 D. Sheng, A. R. Perry, S. P. Krzyzewski, S. Geller, J. Kitching, and S. Knappe, Applied Physics Letters 110 , 031106 (2017).
- 17 C. Johnson, P. D. D. Schwindt, and M. Weisend, Applied Physics Letters 97 , 243703 (2010).
- 18 S. Xu, S. M. Rochester, V. V. Yashchuk, M. H. Donaldson, and D. Budker, Review of Scientific Instruments 77 , 083106 (2006).
- 23 Z. Li, R. T. Wakai, and T. G. Walker, Applied Physics Letters 89 , 134105 (2006).
- 24 P. C. D. Hobbs, Building Electro-Optical Systems: Making it all Work , Vol. I (Wiley-VCH, 2004).
- 26 L. K. Hornberger and K. Collins, Journal of the American College of Cardiology 51 , 85 (2008).
- 29 D. Cohen and H. Hosaka, Journal of Electrocardiology 9 , 409 (1976).
- G. Bison, N. Castagna, A. Hofer, P. Knowles, J.-L. Schenker, M. Kasprzak, H. Saudan, and A. Weis, Applied Physics Letters 95 , 173701 (2009).
Cited by
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
Quantum‐Based Magnetic Field Sensors for Biosensing
Bao, B., Hua, Y., Wang, R., & Li, D. (2023) · Advanced Quantum Technologies · doi:10.1002/qute.202200146 · Cited by 108
How to build a magnetometer with thermal atomic vapor: a tutorial
Fabricant, A. M., Novikova, I. V., & Bison, G. (2023) · New Journal of Physics · doi:10.1088/1367-2630/acb840 · Cited by 162
Tang, J., Zhai, Y., Zhou, B., Han, B., & Liu, G. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3112797 · Cited by 102
Three-axis closed-loop optically pumped magnetometer operated in the SERF regime
Yan, Y., Lu, J., Zhang, S., Lu, F., Yin, K., Wang, K., Zhou, B., & Liu, G. (2022) · Optics Express · doi:10.1364/oe.458367 · Cited by 89
Metadata
- Authors
- Sulai, I. A., DeLand, Z. J., Bulatowicz, M. D., Wahl, C. P., Wakai, R. T., & Walker, T. G.
- Affiliations
- Bucknell University (US)
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2019-08-01
- Volume
- 90
- Issue
- 8
- Pages
- 085003-085003
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- PMC
- PMC6690843
- OpenAlex
- W2969110641
- Cited by
- 79
- References
- 32
- Citations by year
- 2026: 6 · 2025: 16 · 2024: 11 · 2023: 19 · 2022: 12 · 2021: 11 · 2020: 4
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Review of Scientific Instruments (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Funders
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R01HD057965)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Keywords
- atomic magnetometer, spin-exchange relaxation-free, vector magnetometer, fetal magnetocardiography, common-mode rejection, background suppression
- MeSH terms
- Calibration, Equipment Design, Female, Fetus, Humans, Mothers, Signal Processing, Computer-Assisted, Magnetocardiography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.