Characterizing atomic magnetic gradiometers for fetal magnetocardiography
Open accessThe DOI matches its Crossref record; 31 of the 32 references it cites were found in a registry or an index.
Abstract
Atomic magnetometers (AMs) offer many advantages over superconducting quantum interference devices due to, among other things, having comparable sensitivity while not requiring cryogenics. One of the major limitations of AMs is the challenge of configuring them as gradiometers. We report the development of a spin-exchange relaxation free vector atomic magnetic gradiometer with a sensitivity of 3 fT cm−1 Hz−1/2 and common mode rejection ratio >150 in the band from DC to 100 Hz. We introduce a background suppression figure of merit for characterizing the performance of gradiometers. It allows for optimally setting the measurement baseline and for quickly assessing the advantage, if any, of performing a measurement in a gradiometric mode. As an application, we consider the problem of fetal magnetocardiography (fMCG) detection in the presence of a large background maternal MCG signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
High-Sensitivity Atomic Magnetometer Unaffected by Spin-Exchange Relaxation
Allred, J. C., Lyman, R. N., Kornack, T. W., & Romalis, M. V. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.130801 · Cited by 1,049
Ultrahigh sensitivity magnetic field and magnetization measurements with an atomic magnetometer
Dang, H. B., Maloof, A. C., & Romalis, M. V. (2010) · Applied Physics Letters · doi:10.1063/1.3491215 · Cited by 891
SQUID Sensors: Fundamentals, Fabrication and Applications
(1996) · doi:10.1007/978-94-011-5674-5 · Cited by 367
Subfemtotesla Scalar Atomic Magnetometry Using Multipass Cells
Sheng, D., Li, S., Dural, N., & Romalis, M. V. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.160802 · Cited by 364
Magnetoencephalography with a chip-scale atomic magnetometer
Sander, T. H., Preusser, J., Mhaskar, R., Kitching, J., Trahms, L., & Knappe, S. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.000981 · Cited by 293
Magnetoencephalography with a two-color pump-probe, fiber-coupled atomic magnetometer
Johnson, C., Schwindt, P. D. D., & Weisend, M. (2010) · Applied Physics Letters · doi:10.1063/1.3522648 · Cited by 210
A room temperature 19-channel magnetic field mapping device for cardiac signals
Bison, G., Castagna, N., Hofer, A., Knowles, P., Schenker, J.-L., Kasprzak, M., Saudan, H., & Weis, A. (2009) · Applied Physics Letters · doi:10.1063/1.3255041 · Cited by 186
A microfabricated optically-pumped magnetic gradiometer
Sheng, D., Perry, A. R., Krzyzewski, S. P., Geller, S., Kitching, J., & Knappe, S. (2017) · Applied Physics Letters · doi:10.1063/1.4974349 · Cited by 179
Research works printed but not linked: 11
- 2006, Oceans 2006, 1
- 9 J. Clarke and A. I. Braginski, The SQUID Handbook (John Wiley and Sons, Inc, 2009).
- 11 H. B. Dang, A. C. Maloof, and M. V. Romalis, Applied Physics Letters 97 , 151110 (2010).
- 16 D. Sheng, A. R. Perry, S. P. Krzyzewski, S. Geller, J. Kitching, and S. Knappe, Applied Physics Letters 110 , 031106 (2017).
- 17 C. Johnson, P. D. D. Schwindt, and M. Weisend, Applied Physics Letters 97 , 243703 (2010).
- 18 S. Xu, S. M. Rochester, V. V. Yashchuk, M. H. Donaldson, and D. Budker, Review of Scientific Instruments 77 , 083106 (2006).
- 23 Z. Li, R. T. Wakai, and T. G. Walker, Applied Physics Letters 89 , 134105 (2006).
- 24 P. C. D. Hobbs, Building Electro-Optical Systems: Making it all Work , Vol. I (Wiley-VCH, 2004).
- 26 L. K. Hornberger and K. Collins, Journal of the American College of Cardiology 51 , 85 (2008).
- 29 D. Cohen and H. Hosaka, Journal of Electrocardiology 9 , 409 (1976).
- G. Bison, N. Castagna, A. Hofer, P. Knowles, J.-L. Schenker, M. Kasprzak, H. Saudan, and A. Weis, Applied Physics Letters 95 , 173701 (2009).
Cited by
Ultrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
Quantum‐Based Magnetic Field Sensors for Biosensing
Bao, B., Hua, Y., Wang, R., & Li, D. (2023) · Advanced Quantum Technologies · doi:10.1002/qute.202200146 · Cited by 108
How to build a magnetometer with thermal atomic vapor: a tutorial
Fabricant, A. M., Novikova, I. V., & Bison, G. (2023) · New Journal of Physics · doi:10.1088/1367-2630/acb840 · Cited by 162
Tang, J., Zhai, Y., Zhou, B., Han, B., & Liu, G. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3112797 · Cited by 102
Three-axis closed-loop optically pumped magnetometer operated in the SERF regime
Yan, Y., Lu, J., Zhang, S., Lu, F., Yin, K., Wang, K., Zhou, B., & Liu, G. (2022) · Optics Express · doi:10.1364/oe.458367 · Cited by 89
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Webb, J. L., Troise, L., Hansen, N. W., Olsson, C., Wojciechowski, A. M., Achard, J., Brinza, O., Staacke, R., Kieschnick, M., Meijer, J., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-81828-x · Cited by 84
Fourcault, W., Romain, R., Le Gal, G., Bertrand, F., Josselin, V., Le Prado, M., Labyt, E., & Palacios-Laloy, A. (2021) · Optics Express · doi:10.1364/oe.420031 · Cited by 65
Wacker‐Gussmann, A., Strasburger, J. F., & Wakai, R. T. (2022) · Journal of the American Heart Association · doi:10.1161/jaha.121.025224 · Cited by 58
Self-citationZhao, F., Zhou, X., Xie, X., & Wang, K. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2021.3106677 · Cited by 58
Compact multi-channel optically pumped magnetometer for bio-magnetic field imaging
Yuan, Z., Liu, Y., Xiang, M., Gao, Y., Suo, Y., Ye, M., & Zhai, Y. (2023) · Optics & Laser Technology · doi:10.1016/j.optlastec.2023.109534 · Cited by 45
Single beam Cs-Ne SERF atomic magnetometer with the laser power differential method
Chen, Y., Zhao, L., Zhang, N., Yu, M., Ma, Y., Han, X., Zhao, M., Lin, Q., Yang, P., & Jiang, Z. (2022) · Optics Express · doi:10.1364/oe.450571 · Cited by 42
Sun, B., Zhai, Y., Bandaru, S., Cheng, T., Huang, Y., Chen, K., Zheng, S., Han, B., Li, J., Ma, D., et al. (2026) · Nano Research · doi:10.26599/nr.2026.94908875 · Cited by 46
Active Magnetic-Field Stabilization with Atomic Magnetometer
Zhang, R., Ding, Y., Yang, Y., Zheng, Z., Chen, J., Peng, X., Wu, T., & Guo, H. (2020) · Sensors · doi:10.3390/s20154241 · Cited by 32
“, using several identical magnetometers inside the magnetic shield and subtracting the measurement results of these magnetometers [28] The noise rejection ratio in the low-frequency region can be improved by actively stabilizing the magnetic field [29–31].”
MethodDesign and Analysis of a High-Sensitivity Atomic Magnetic Gradiometer With Adjustable Baseline
Zhang, Y., Tang, J., Xu, X., Wang, Z., & Zhai, Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3544375 · Cited by 27
Zhang, G., Zeng, H., Tan, G., & Lin, Q. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3156814 · Cited by 26
A 4He vector zero-field optically pumped magnetometer operated in the Earth-field
Bertrand, F., Jäger, T., Boness, A., Fourcault, W., Gal, G. L., Palacios-Laloy, A., Paulet, J., & Léger, J. (2021) · Review of Scientific Instruments · doi:10.1063/5.0062791 · Cited by 26
Gradient phase and amplitude errors in atomic magnetic gradiometers for biomagnetic imaging systems
Yuan, Z., Lin, S., Liu, Y., Tang, J., Long, T., & Zhai, Y. (2024) · iScience · doi:10.1016/j.isci.2024.109250 · Cited by 24
Han, X., Xue, X., Yang, Y., Liang, X., Gao, Y., Xiang, M., Sun, J., & Ning, X. (2023) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ace497 · Cited by 25
Roth, B. J. (2024) · Biophysics Reviews · doi:10.1063/5.0201950 · Cited by 24
Gal, G. L., Rouve, L.-L., & Palacios-Laloy, A. (2021) · Applied Physics Letters · doi:10.1063/5.0047124 · Cited by 24
Indium Tin Oxide Non-Magnetic Heating Film for Miniaturized SERF Gradient Magnetometer
Liu, Z., Zhang, C., Yuan, H., Yin, K., Yang, Y., Yan, Y., Wang, Y., Zhou, B., Ning, X., & Han, B. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3076133 · Cited by 22
Progress and applications of quantum precision measurement based on SERF effect
Zhai, Y., Yue, Z., Li, L., & Liu, Y. (2022) · Frontiers in Physics · doi:10.3389/fphy.2022.969129 · Cited by 23
Zhao, W., Tao, X., Ye, C., & Tao, Y. (2022) · Sensors · doi:10.3390/s22031021 · Cited by 21
Femtotesla Spin-Exchange Relaxation-Free Atomic Magnetometer With a Multipass Cell
Qi, Y., Li, B., Wang, S., Xu, N., Qian, Y., & Lu, J. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3460884 · Cited by 19
Han, X., Pang, J., Xu, D., Xie, F., Li, Y., Xiang, M., Sun, J., Chen, Y., & Ning, X. (2025) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2025.108764 · Cited by 21
Xie, X., Zhou, X., Zhao, F., Wang, W., & Sun, J. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3323996 · Cited by 18
Second-order effects in parametric-resonance magnetometers based on atomic alignment
Beato, F., & Palacios-Laloy, A. (2020) · EPJ Quantum Technology · doi:10.1140/epjqt/s40507-020-00083-7 · Cited by 17
Yu, Q.-Q., Liu, S.-Q., Wang, X.-K., & Sheng, D. (2023) · Physical Review A · doi:10.1103/physreva.107.043110 · Cited by 15
Ultra-high consistency multichannel SERF atomic magnetometer based on diffractive optics
Li, J., Liu, Y., Chai, Z., Cao, Q., Li, R., & Zhai, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114868 · Cited by 16
Single‐Beam Vector Atomic Magnetometer with High Dynamic Range Based on Magnetic Field Modulation
Chen, J., Jiang, L., Zhao, X. H., Liu, J., Chai, Y., Tian, M., & Lu, Z. (2024) · Advanced Quantum Technologies · doi:10.1002/qute.202400289 · Cited by 15
Ultra-low noise, bi-polar, programmable current sources
Mrozowski, M. S., Chalmers, I. C., Ingleby, S. J., Griffin, P. F., & Riis, E. (2023) · Review of Scientific Instruments · doi:10.1063/5.0114760 · Cited by 20
Dong, H., Ye, H., Hu, M., & Ma, Z. (2023) · Micromachines · doi:10.3390/mi15010059 · Cited by 15
Suo, Y., Song, X., Jia, L., Long, T., Ye, M., & Zhou, B. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3198502 · Cited by 14
Wu, Z., Zhang, J., He, M., Ren, B., Wang, Z., Chen, W., Ou, Z., Yue, H., Zhou, X., & Liu, Y. (2023) · Optics Express · doi:10.1364/oe.484984 · Cited by 13
Electromagnetic induction imaging with a SERF atomic magnetometer
Fang, F., & Wang, Z. (2024) · Optics & Laser Technology · doi:10.1016/j.optlastec.2024.112144 · Cited by 12
A non-magnetic packaged Vertical-Cavity Surface-Emitting Laser for SERF magnetometers
Zhou, P., Zhang, G., Liang, Z., Hu, J., Liu, L., Hu, G., Wang, A., Du, P., & Ye, M. (2024) · Measurement · doi:10.1016/j.measurement.2024.116381 · Cited by 13
Jofre, M., Romeu, J., & Jofre, L. (2023) · New Journal of Physics · doi:10.1088/1367-2630/acb37a · Cited by 16
Li, J., Liu, Y., Li, R., Cao, Q., Zhou, T., & Zhai, Y. (2023) · Results in Physics · doi:10.1016/j.rinp.2023.107231 · Cited by 11
Femtotesla atomic magnetometer with counter-propagating optical sideband pumping
Peng, J., Xu, A., & Liu, B. (2024) · Optics Letters · doi:10.1364/ol.540032 · Cited by 10
Wang, Y., Xiao, R., Xiao, N., Wen, Y., Chen, L., Li, P., Ji, X., Song, J., & Han, T. (2020) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2020.167659 · Cited by 10
Silva, M., Franco, F., Leitão, D. C., Cardoso, S., & Freitas, P. P. (2021) · Scientific Reports · doi:10.1038/s41598-020-79856-0 · Cited by 10
Zhang, J., Liu, J., Zhang, Q., Филиппов, Д. А., Li, K., Wu, J., Tao, J., Jiang, L., Cao, L., & Srinivasan, G. (2021) · Review of Scientific Instruments · doi:10.1063/5.0035059 · Cited by 10
Niu, Y., & Ye, C. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3299690 · Cited by 9
Effects of system parameters on a single-beam synthetic gradiometer with a dual-cell structure
Wu, Z., Zhang, J., Chen, W., Ou, Z., Yue, H., Cheng, C., & Liu, Y. (2024) · Optics Letters · doi:10.1364/ol.518697 · Cited by 8
Femtotesla 87Rb magnetometer based on a coaxial pump-probe beam delivery system
Zhao, B., Tang, J., Li, L., Zhang, Y., Liu, Y., & Zhai, Y. (2023) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2023.114856 · Cited by 8
Xu, X., Zhai, Y., Zhao, B., Zhang, Y., Yue, Z., & Tang, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3612562 · Cited by 7
Modulation crosstalk effect analysis on single-beam SERF atomic magnetic gradiometer
Chen, T., Zheng, Z., Zhang, J., Chen, Z., Chen, W., Ou, Z., Yue, H., & Liu, Y. (2025) · Measurement · doi:10.1016/j.measurement.2025.117782 · Cited by 8
Light-noise suppression method for the single-beam optically-pumped magnetometer arrays
Suo, Y., Song, X., Wu, Z., Yuan, Z., Jia, L., & Long, T. (2023) · Optics Express · doi:10.1364/oe.489172 · Cited by 5
Ranjbaran, M., sedeyan, R., Zamani, A., Tehranchi, M. M., Khalkhali, S. M. H., & Hamidi, S. M. (2024) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2024.172335 · Cited by 5
Peng, J., Xu, A., Tang, Y., Li, R., Zhan, M., Liu, Y., Liu, B., & Deng, L. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3443284 · Cited by 6
Karabinaoğlu, M. S., Caklı, B. M., & Sevim, M. H. (2025) · IEEE Sensors Letters · doi:10.1109/lsens.2025.3544963 · Cited by 5
The suppression of magnetic noise in a magnetic shielding unit for atomic sensor applications
Karabinaoğlu, M. S., Günay, E., Çakır, B., Caklı, B. M., & Sevim, M. H. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116833 · Cited by 4
Xie, X., Zhou, X., Zhao, F., Wang, W., Yin, C., & Sun, J. (2024) · Physica Scripta · doi:10.1088/1402-4896/ad7234 · Cited by 4
Gradient Field Detection Using Interference of Stimulated Microwave Optical Sidebands
Campbell, K., Wang, Y.-J., Savukov, I., Schwindt, P. D. D., Jau, Y., & Shah, V. (2022) · Physical Review Letters · doi:10.1103/physrevlett.128.163602 · Cited by 4
A miniaturized spin-exchange relaxation-free atomic magnetometer based on uniform light field
Li, J., Fang, X., Li, R., Chen, B., Zhai, Y., & Liu, Y. (2022) · Chinese Physics B · doi:10.1088/1674-1056/aca7f2 · Cited by 4
Bandwidth Enhancement for Magnetic-Field-Modulation-Free SERF Magnetometers
Ma, X., Qin, B., Yang, Y., He, K., Li, C., Sheng, J., Yu, L., Huang, Y., Pang, W., Lyu, B., et al. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3542464 · Cited by 3
Feedback Methods for Vector Measurements Using an All-Optical Atomic Magnetometer
Bulatowicz, M., Tost, J., & Walker, T. G. (2023) · Sensors · doi:10.3390/s23094263 · Cited by 3
Self-citationMicrofabricated Optically Pumped Gradiometer with Uniform Buffer Gases
Parrish, A. R., Noor, R. M., & Shkel, A. M. (2021) · IEEE International Symposium on Inertial Sensors and Systems (INERTIAL) · doi:10.1109/inertial51137.2021.9430474 · Cited by 3
Chivers, S. C., Pini, N., Chowdhury, S., Cicci, L., Vigneswaran, T. V., Zidere, V., Maxwell, S., Moriarty, G., Regan, W. L., Rosenthal, É., et al. (2025) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.124.013556 · Cited by 4
Frequency-dependent gradient error suppression method for optically pumped magnetic gradiometers
Lin, S., Yuan, Z., Ma, Y., Zhai, Y., & Tang, J. (2025) · Measurement · doi:10.1016/j.measurement.2025.118138 · Cited by 3
A CNN-GS Hybrid Algorithm for Generating Pump Light Fields in Atomic Magnetometers
Song, M. K., Liu, Y., Lu, F., Cao, Q., & Zhai, Y. (2025) · Photonics · doi:10.3390/photonics12080796 · Cited by 3
Tian, X., Bao, B., Wang, R., & Li, D. (2025) · Sensors · doi:10.3390/s25123690 · Cited by 3
Dynamic range and linearity improvement for zero-field single-beam atomic magnetometer
Yin, K., Lu, J., Lu, F., Li, B., Zhou, B., & Ye, M. (2022) · Chinese Physics B · doi:10.1088/1674-1056/ac6010 · Cited by 2
Fiber-Coupled OPM in Purely Coil-Shielded Environment
Wu, T., Peng, X., Chen, J., & Guo, H. M. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_9 · Cited by 2
Vector Magnetic Field Detection of Microparticles Using Differential Dual-Pump Magnetometer
Liu, Y., Huang, B., Song, M. K., An, Y., & Zhai, Y. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3648001 · Cited by 1
Three-dimensional visualization of MCG signals using CW_FastICA and transfer function mapping
Zhang, J., Song, X., Jia, L., Long, T., Sun, H., Zheng, C., Chen, K., Qi, S., Zhou, B., & Liu, G. (2026) · Measurement · doi:10.1016/j.measurement.2026.121175 · Cited by 4
Spin-Feedback-Enhanced Atomic Magnetic Gradiometer
Ma, Y., Lin, S., Yuan, Z., Zhai, Y., & Tang, J. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3704257 · Cited by 1
Design of an Integrated MEMS Magnetic Gradiometer Rejecting Vibrations and Stray Fields
Gasparin, E., Hoogerwerf, A. C., Bayat, D. Z., Durante, G. S., Pétremand, Y., Tormen, M., Despont, M., & Close, G. F. (2025) · IEEE Journal of the Electron Devices Society · doi:10.1109/jeds.2025.3543662 · Cited by 1
A single beam Cs-Ne SERF magnetometer with differential laser power noise suppression methodPreprint
Chen, Y., Ma, Y., Yu, M., Zhang, N., Zhao, L., Han, X., & Jiang, Z. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2101.01811 · Cited by 2
Optically Pumped Magnetometers Compatible with Large Transient Magnetic Fields
Nardelli, N. V., Krzyzewski, S., & Knappe, S. A. (2022) · Springer eBooks · doi:10.1007/978-3-031-05363-4_2
Detuned square-wave optical modulation zero-field atomic magnetometer
Li, X., Han, B., Lu, J., Liu, Z., & Yan, Y. (2023) · Optics Young Scientist Summit (OYSS) · doi:10.1117/12.3015902
Atomic Gradiometers for Accuracy Enhancement of Heart Magnetic Fields Measurement
Ranjbaran, M., sedeyan, R., Zamani, A., Tehranchi, M. M., Khalkhali, S. M. H., & Hamidi, S. M. (2023) · Dunyā. · doi:10.61186/ijop.17.2.155
Miniature Quantum Gradiometer Using 3D Interconnected Atomic Vapor Cells
Zhang, J., & Shang, J. (2025) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/mems61431.2025.10917793
Response of comagnetometers to exotic spin-dependent couplings
Zhao, Y., Peng, X., Wu, T., & Guo, H. (2025) · Physical review. D/Physical review. D. · doi:10.1103/824f-v3w5
Spatial symmetry-broken atomic magnetometry
Park, S. S., Lee, M.-H., Kim, H., Ju, J., Lee, S. A., Baek, J., Noh, H., & Moon, G. (2025) · Optics Express · doi:10.1364/oe.568742
Han, G., Song, K., Qiu, Y., & Liu, X. (2026) · Review of Scientific Instruments · doi:10.1063/5.0315645
Xu, C., Wu, L., Jiang, J., Dai, Y., Ye, H., Dong, H., & Chen, J. C. (2026) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2026.3714614
Jiang, L., Yang, J., Chen, J., Zhang, C., Peng, Z., Bei, S., & Liu, J. (2026) · Measurement · doi:10.1016/j.measurement.2026.122636
Metadata
- Authors
- Sulai, I. A., DeLand, Z. J., Bulatowicz, M. D., Wahl, C. P., Wakai, R. T., & Walker, T. G.
- Affiliations
- Bucknell University (US)
- Venue
- Review of Scientific Instruments
- Publisher
- AIP Publishing
- Published
- 2019-08-01
- Volume
- 90
- Issue
- 8
- Pages
- 085003-085003
- ISSN
- 0034-6748 (ISSN-L)
- 1089-7623
- PMC
- PMC6690843
- OpenAlex
- W2969110641
- Cited by
- 79
- References
- 32
- Citations by year
- 2026: 6 · 2025: 16 · 2024: 11 · 2023: 19 · 2022: 12 · 2021: 11 · 2020: 4
- FWCI
- 2.97
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Review of Scientific Instruments (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- arXiv (Cornell University) (submittedVersion)
- arXiv (Cornell University)
- Funders
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R01HD057965)
- Topics
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Cold Atom Physics and Bose-Einstein Condensates
- Keywords
- atomic magnetometer, spin-exchange relaxation-free, vector magnetometer, fetal magnetocardiography, common-mode rejection, background suppression
- MeSH terms
- Calibration, Equipment Design, Female, Fetus, Humans, Mothers, Signal Processing, Computer-Assisted, Magnetocardiography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.